Configure File System Client Configuration page
This page connects the SAN client as a media le system client to the K2 Media Server taking the
role of media le system server. If there are redundant K2 Media Servers, both are listed on this
page as le system servers.
1. Verify that the K2 client is connecting to the correct K2 Media Server or Servers, as follows:
• For a basic (non-redundant) K2 SAN, the client connects to the only server.
• For a redundant K2 SAN, the client connects to server A as le system server 1 and server
B as le system server 2.
2. Click Check.
3. When the wizard reports that the conguration check is successful, click Next.
Repeat these tasks to add remaining SAN clients to the K2 SAN.
Adding a generic client device
Prerequisites for adding a generic client to an existing K2 SAN are as follows:
• You must be logged in to the K2Cong application with permissions equivalent to K2
administrator or higher.
• The devices of the K2 SAN do not need to be ofine, and there is no restart of devices required.
1. In SiteCong, add the client device to the appropriate group and verify that it is communicating
correctly on networks.
2. In the K2Cong application tree view, select the name of the K2 SAN, which is the top node of
the storage system tree.
2013 07 20 K2 Installation and Service Manual 233
Conguring clients on the K2 SAN