Service manual
Network and SNMP settings are set and stored on the RAID controller. Therefore, if the RAID
chassis has two controllers, each controller must be congured separately, as in the following
procedure.
1. In the K2Cong application tree view, open the node for a K2 Media Server and select the File
System Server node to open its property page. On the property page click Launch Storage Utility.
Storage Utility opens. You can now congure the network settings on the controller connected
to the selected K2 Media Server.
2. In the Storage Utility, right-click the icon for a RAID controller and select Configuration | Network
Properties. The Network Settings dialog box opens.
3. In the Controller Slot Number eld enter 0 and then press Enter. The settings from controller 0
are loaded into the Controller Network Settings dialog box and are available for you to modify.
4. Enter the control network IP address and other network settings.
5. You want SNMP trap messages go to a SNMP manager, so for SNMP Conguration enter the
IP address of the SNMP manager PC. You can also enter IP addresses for other SNMP managers
to which you want to send SNMP trap messages.
6. If the RAID chassis has two controllers, in the Controller Slot Number eld enter 1 and then
press Enter. The settings from controller 1 are loaded into the Controller Network Settings dialog
box and are available for you to modify. Repeat the previous steps to congure controller 1.
7. Click OK to save settings and close.
8. Restart the RAID chassis to put SNMP conguration changes into effect.
2013 07 20 K2 Installation and Service Manual 327