Release Notes

Release NotesFluid Cache for SAN for VMware Systems
kernel OOM due to fldc_cache at 95pct
Initial resilvering doesn't complete for CS on restarted node
Software and Hardware Compatibility
Table 2 Hardware and Software Requirements
Element
Servers
Dell PowerEdge systems that support Dell Express Flash PCIe SSDs and SR-
IOV:
M620, M820, R620, R720, R820, R920, or T620
R730, R730XD, R630, or T630
Operating systems
ESXi 5.5 Update 2 (64-bit) Enterprise Plus
ESXi 6.0 (64-bit) Enterprise Plus
RAM and hard disk
space
Minimum of 64 GB RAM (the VSA uses 20 GB)
A datastore with 30 GB of available disk space
Cache Devices
Dell Express Flash PCIe SSD of either 175GB, 350GB, 400GB, 800GB, or
1.6TB capacity
Micron HHHL PCIe SSDs (700 GB or 1.4 TB)
Network adapters
Mellanox ConnectX-3 Dual Port 10 GbE SFP+ Adapter
Mellanox ConnectX-3 Dual Port 40 GbE QSFP+ Adapter
Mellanox ConnectX-3 Dual Port 10 GbE KR Mezzanine Adapter
FC Host Bus
Adapters
Emulex:
LPE12002
LPE12000
LPE16000B
LPE16002B
Qlogic:
QLE2562
QLE2662
QLE2560
QLE2660
Cache network
switches
The following switches have been validated for use with Fluid Cache.
Dell Networking S4810
Dell Networking S6000
Dell Networking Z9000
Dell Networking Z9500
Dell Networking MXL 10/40 GbE
Cisco Nexus 5584UP
Storage Center
software
Dell Compellent Storage Center 6.5.2 or higher
Dell Compellent Enterprise Manager 2014 R2 or higher
Storage Center
hardware
Dell Compellent SC8000 controller
Dell - Internal Use - Confidential
Page 6 3/9/2015