Service Manual
* Management Unit
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6
Sensor7 Sensor8 Sensor9
-------------------------------------------------------
0 50 52 53 53 54 48 57
57 53 56
Dell#
Example (stack-unit)
Dell#show environment stack-unit 0
-- Unit Environment Status --
Unit Status Temp Voltage
------------------------------------
0* online 49C ok
* Management Unit
Example (thermal-
sensor)
Dell#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6
Sensor7 Sensor8 Sensor9
---------------------------------------------------------
0 50 52 53 53 54 48 57
57 53 56
* Management Unit
Dell#
show inventory
Display the switch type, components (including media), and Dell Networking OS version including hardware identification numbers and
configured protocols.
Syntax
show inventory [media slot]
Parameters
media slot (OPTIONAL) Enter the keyword media then the stack ID of the stack member you want
to display pluggable media inventory.
Defaults none
Command Modes EXEC
Command History
Version Description
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information If there are no fiber ports in the unit, just the header under show inventory media displays. If there are fiber
ports but no optics inserted, the output displays "Media not present or accessible".
Example
Dell#show inventory
System Type : MXL-10/40GbE
System Mode : 1.0
Software Version : NAVASOTA-DEV-9-1-0-917
Unit Type Serial Number Part Number Revision
--------------------------------------------------------------
* 1 MXL-10/40GbE TW282921F00048 0NVH81 2.0
Control and Monitoring 101