Service Manual
Command History
Version Description
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information When the number of messages reach the limit you set with the logging history size command, older
messages are deleted as newer ones are added to the table.
Related Commands
show logging — displays information logged to the history buffer.
logging monitor
Specify which messages are logged to Telnet applications.
Syntax
logging monitor [level]
To disable logging to terminal connections, use the no logging monitor command.
Parameters
level Indicate a value from 0 to 7 or enter one of the following parameters: emergencies,
alerts, critical, errors, warnings, notifications, informational, or
debugging. The default is 7 or debugging.
Defaults 7 or debugging
Command Modes CONFIGURATION
Command History
Version Description
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Related Commands
default logging monitor — returns the logging monitor parameters to the default setting.
logging on
Specify that debug or error messages are asynchronously logged to multiple destinations, such as the logging buffer, Syslog server, or
terminal lines.
Syntax
logging on
To disable logging to logging buffer, Syslog server and terminal lines, use the no logging on command.
Defaults Enabled.
Command Modes CONFIGURATION
Command History
Version Description
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information When you use the no logging on command, messages are logged only to the console.
Related Commands
logging — enables logging to the Syslog server.
Simple Network Management Protocol (SNMP) and Syslog 1161