Service Manual

Stacking
For more information about using the Switch stacking feature, see the Stacking MXL 10/40GbE Switches chapter in the Dell Networking
OS Configuration Guide.
NOTE: The terms stack-unit-id, unit-id, stack-unit-number, stack-number, and unit-number mentioned
in this chapter refers to the stack-unit-number.
Topics:
redundancy disable-auto-reboot
redundancy force-failover stack-unit
reset stack-unit
show redundancy
show system stack-ports
show system stack-unit stack-group
stack-unit stack-group
stack-unit priority
stack-unit provision
stack-unit renumber
redundancy disable-auto-reboot
Prevent the switch stack management unit from rebooting if it fail.
Syntax
redundancy disable-auto-reboot stack-unit [0–5 | members]
To return to the default, use the no redundancy disable-auto-reboot stack-unit [0–5 |
members] command.
Defaults Disabled (the failed switch is automatically rebooted).
Command Modes CONFIGURATION
Command History
Version Description
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information
When the command is given as redundancy disable-auto-reboot stack-unit, it prevents the switch
stack management unit and standby unit from rebooting if they fail.
When a particular unit number in the range from 0 to 5 is issued as part of the CLI, it prevents that particular unit
from rebooting after failure.
When members are issued as part of the CLI, all the units part of the stack are prevented from rebooting after
failure.
53
1168 Stacking