Service Manual
The unit does not reboot until it is manually rebooted.
Related Commands show redundancy — displays the current redundancy status.
redundancy force-failover stack-unit
Force the standby unit in the stack to become the management unit.
Syntax
redundancy force-failover stack-unit
Defaults Not enabled.
Command Modes EXEC Privilege
Command History
Version Description
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
reset stack-unit
Reset any designated stack member except the management unit (master unit).
Syntax
reset stack-unit 0–5 hard
Parameters
0–5 Enter the stack member unit identifier of the stack member to reset.
hard Reset the stack unit if the unit is in a problem state.
Defaults none
Command Modes EXEC
Command History
Version Description
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information
Resetting the management unit is not allowed, and an error message displays if you try to do so. Resetting is a soft
reboot, including flushing the forwarding tables.
Starting with the Dell Networking OS version 7.8.1.0, you can run this command directly on the stack standby unit
(standby master) to reset the standby. You cannot reset any other unit from the standby unit.
The first two bold lines in the following example show the output of a not allowed reset action. The third bold line
shows the output of a successful reset action.
Example
Dell# show system brief
Stack MAC : 00:1e:c9:f1:00:7b
Reload Type : jump-start [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
------------------------------------------------------------------
0 Management online MXL-10/40GbE MXL-10/40GbE 9-1-0-853 56
1 Standby online MXL-10/40GbE MXL-10/40GbE 9-1-0-853 56
Stacking 1169