You must first create a VLAN and then specify the configured VLAN ID in the fabric-id vlan command.
Otherwise, the following error message is displayed.
FTOS(conf-fcoe-f)#fabric-id 10 vlan 10 % Error: Vlan 10 does not exist
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers
and a SAN fabric.
show fcoe-map— displays the Fibre Channel and FCoE configuration parameters in FCoE maps.
fcf-priority
In an FCoE map, configure the priority used by a server CNA to select an upstream FCoE forwarder (FCF).
M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO module
Syntax
fcf—priority priority
Parameters
priority Enter the priority assigned to the M I/O Aggregator and MXL 10/40GbE Switch with the
FC Flex IO module NPIV proxy gateway, which appears to a downstream server CNA as
an FCF. The range of FCF priority values is from 1 to 255.
Defaults 128
Command Modes FCOE MAP
Command History
Version 9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO
module.
Usage Information
The FCF priority you assign to an M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO module is
used by server CNAs to select an upstream FCF to use for a fabric login (FLOGI).
To remove a configured FCF priority from an FCoE map, enter the no fcf-priority command.
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers
and a SAN fabric.
show fcoe-map— displays the Fibre Channel and FCoE configuration parameters in FCoE maps.
fc-map
In an FCoE map, configure the FCoE mapped address prefix (FC-MAP) value which is used to identify FCoE traffic transmitted on the
FCoE VLAN for the specified fabric.
Syntax
fc—map fc-map-value
Parameters
fc-map-value Enter the unique MAC address prefix used by a SAN fabric.