Service Manual
monitor (OPTIONAL) Enter the keyword monitor to monitor traffic on the monitoring interface
specified in the flow-based monitoring session along with the filter operation.
Defaults
By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which
ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled.
Command Modes ACCESS-LIST
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Added the support for flow-based monitoring on the MXL 10/40GbE Switch IO Module
platform
9.3(0.0) Added the support for logging of ACLs on the MXL 10/40GbE Switch IO Module
platform
9.2(0.0) Introduced on the MXL 10/40GbE Switch IO Module platform.
Usage Information
When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which
ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet
count for that new interval commences from zero. If ACL logging was stopped previously because the configured
threshold is exceeded, it is re-enabled for this new interval.
If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval
period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You
can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs
that are associated with egress interfaces.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable
command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are
traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both
the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic
instead all traffic on the interface. This feature is particularly useful when looking for malicious traffic. It is available
for Layer 2 and Layer 3 ingress and egress traffic. You may specify traffic using standard or extended access-lists.
This mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port.
The source port is the monitored port (MD) and the destination port is the monitoring port (MG).
permit
To configure a filter that matches the filter criteria, select an IPv6 protocol number, ICMP, IPv6, TCP, or UDP.
Syntax
permit {ipv6-protocol-number | icmp | ipv6 | tcp | udp} [count [byte]] [dscp
value] [order] [fragments] [log [interval minutes] [threshold-in-msgs [count]]
[monitor]
To remove this filter, you have two choices:
• Use the no seq sequence-number command syntax if you know the filter’s sequence number
•
Use the no permit {ipv6-protocol-number | icmp | ipv6 | tcp | udp} command
Parameters
ip-protocol-number Enter an IPv6 protocol number. The range is from 0 to 255.
246 Access Control Lists (ACL)