Service Manual

stack unit 0
syncing disks... 1 1 done
unmounting file systems...
unmounting /f10/flash (/dev/ld0e)...
unmounting /usr/pkg (/dev/ld0h)...
unmounting /usr (mfs:35)...
unmounting /lib (mfs:24)...
unmounting /f10 (mfs:21)...
unmounting /tmp (mfs:15)...
unmounting /kern (kernfs)...
unmounting / (/dev/md0a)... done
rebooting...
offline stack-unit
Place a stack unit in the offline state.
Syntax
offline stack-unit number
Parameters
number Enter the stack-unit number. The range is from 0 to 5.
Defaults none
Command Modes EXEC Privilege
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information
The system reboots when the off-line diagnostics complete. This reboot is an automatic process. A warning
message appears when the offline stack-unit command is implemented.
Warning - Diagnostic execution will cause stack-unit to reboot after completion
of diags.
Proceed with Offline-Diags [confirm yes/no]:y
online stack-unit
Place a stack unit in the online state.
Syntax
online stack-unit number
Parameters
number Enter the stack-unit number. The range is from 0 to 5.
Defaults none
Command Modes EXEC Privilege
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
Debugging and Diagnostics 401