Service Manual

Defaults none
Command Modes EXEC
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information If the TDR test has not been run, an error message is generated:
%Error: Please run the TDR test first
The following describes the TDR test status.
Status Definition
OK Status:
Terminated
TDR test is complete, no fault is detected on the cable, and the test is terminated.
Length: 92 (+/- 1)
meters, Status:
Shorted
A short is detected on the cable. The location, in this Example is 92 meters. The short is
accurate to plus or minus one meter.
Length: 93 (+/- 1)
meters, Status:
Open
An opening is detected on the cable. The location, in this Example is 93 meters. The open
is accurate to plus or minus one meter.
Status: Impedance
Mismatch
There is an impedance mismatch in the cables.
Example
Dell#show tdr tengigabitethernet 1/7
Time since last test: 00:00:02
Pair A, Length: OK Status: Terminated
Pair B, Length: 92 (+/- 1) meters, Status: Short
Pair C, Length: 93 (+/- 1) meters, Status: Open
Pair D, Length: 0 (+/- 1) meters, Status: Impedance Mismatch
Related Commands tdr-cable-test — runs the TDR test.
UDP Broadcast
The user datagram protocol (UDP) broadcast feature is a software-based method to forward low throughput (not to exceed 200 pps)
IP/UDP broadcast traffic arriving on a physical or VLAN interface.
Important Points to Remember
Routing information protocol (RIP) is not supported with the UDP Broadcast feature.
If you configure this feature on an interface using the ip udp-helper udp-port command, the ip directed-broadcast
command becomes ineffective on that interface.
The existing show interface command has been modified to display the configured broadcast address.
Interfaces
557