Service Manual
To restore the default value, use the no ipv6 control-plane icmp error-rate-limit command.
Parameters
pps Enter the maximum number of error packets generated per second. The range is from 1
to 200, where 0 disables the rate-limiting.
Default 100 pps
Command Modes CONFIGURATION
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.2(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
ipv6 flowlabel-zero
Configure system to set the flow label field in the packets to zero.
Syntax
ipv6 flowlabel-zero
To disable the 0 from being set in the field and allow the rotocol operations to fill the field, use the no ipv6
flowlabel-zero command.
Default Disabled
Command Modes CONFIGURATION
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.2(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information If the flowlabel value is already set for BGP or SSH, the system defaults to the already configured value. All
packets on the same connection are considered part of the same flow by the system. For new connections, set
the new flowlabel to zero.
ipv6 host
Assign a name and IPv6 address the host-to-IPv6 address mapping table uses.
Syntax
ipv6 host name ipv6-address
To remove an IP host, use the no ipv6 host name {ipv6–address}.
Parameters
name Enter a text string to associate with one IP address.
ipv6-address Enter the IPv6 address (X:X:X:X::X) to be mapped to the name.
Defaults Not configured.
Command Modes CONFIGURATION
618 IPv6 Basics