Service Manual

B: Enter this keyword to upgrade the bootflash partition B.
Defaults none
Command Modes EXEC Privilege
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information Reset the card using the power-cycle option after restoring the FPGA command.
Example
Dell#upgrade system ?
flash: Copy from flash file system (flash://filepath)
ftp: Copy from remote file system, IPv4 or IPv6, (ftp:/
/userid:password@hostip/filepath)
scp: Copy from remote file system, IPv4 or IPv6, (scp:/
/userid:password@hostip/filepath)
stack-unit Sync image to the stack-unit
tftp: Copy from remote file system, IPv4 or IPv6, (tftp:/
/hostip/filepath)
usbflash: Copy from usbflash file system (usbflash://
filepath)
Dell#
verify
Validate the software image on the flash drive after the image has been transferred to the system, but before the image has been
installed.
Syntax
verify { md5 | sha256 }[ flash:// ] img-file [hash-value]
Parameters
md5 Enter the md5 keyword to use the MD5 message-digest algorithm.
sha256
Enter the sha256 keyword to use the SHA256 Secure Hash Algorithm
flash:// (Optional). Enter the flash:// keyword. The default is to use the flash drive. You can
just enter the image file name.
img-file Enter the name the Dell Networking software image file to validate.
hash-value (Optional). Enter the relevant hash published on i-Support.
Defaults flash drive
Command Modes EXEC mode
Command History Version 9.5.(0.0)
Version Description
9.8(1.0) Introduced on the Z9100–ON.
9.5(0.0) Introduced on the Z9000, S6000, S4820T, S4810, and MXL.
File Management 73