Service Manual
graceful-restart t3
Configure the overall wait time before graceful restart completes.
Syntax
graceful-restart t3 {adjacency | manual} seconds
To return to the default, use the no graceful-restart t3 command.
Parameters
adjacency Enter the keyword adjacency so that the restarting router receives the remaining time
value from its peer and adjusts its T3 value so if you have configured this option.
manual Enter the keyword manual to specify a time value that the restarting router uses. The
range is from 50 to 120 seconds. The default is 30 seconds.
Defaults manual, 30 seconds
Command Modes ROUTER ISIS
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.2(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information
The running router sets the remaining time value to the current adjacency hold time. You can override this setting
by implementing this command.
Override the default restart-wait time by entering the no graceful-restart restart-wait command.
When you disable restart-wait, the current adjacency hold time is used.
Set the t3 timer to adjacency on the restarting router when implementing this command. The restarting router
gets the remaining time value from its peer and adjusts its T3 value so only when you have configured
graceful-restart t3 adjacency.
Related Commands graceful-restart restart-wait — enables the graceful restart maximum wait time before a restarting peer comes
up.
graceful-restart restart-wait
Enable the graceful restart maximum wait time before a restarting peer comes up.
Syntax
NOTE: Set the t3 timer to adjacency on the restarting router when implementing this command.
graceful-restart restart-wait seconds
To return to the default, use the no graceful-restart restart-wait command.
Parameters
seconds Enter the graceful restart time in seconds. The range is from 5 to 300 seconds. The
default is 30 seconds.
Defaults 30 seconds
736 Intermediate System to Intermediate System (IS-IS)