Administrator Guide

Dell(conf)# show interface tengigabitethernet 0/49 dcbx detail
Dell#show interface te 0/49 dcbx detail
E-ETS Configuration TLV enabled e-ETS Configuration TLV disabled
R-ETS Recommendation TLV enabled r-ETS Recommendation TLV disabled
P-PFC Configuration TLV enabled p-PFC Configuration TLV disabled
F-Application priority for FCOE enabled f-Application Priority for FCOE disabled
I-Application priority for iSCSI enabled i-Application Priority for iSCSI disabled
----------------------------------------------------------------------------------
Interface TenGigabitEthernet 0/49
Remote Mac Address 00:00:00:00:00:11
Port Role is Auto-Upstream
DCBX Operational Status is Enabled
Is Configuration Source? TRUE
Local DCBX Compatibility mode is CEE
Local DCBX Configured mode is CEE
Peer Operating version is CEE
Local DCBX TLVs Transmitted: ErPfi
Local DCBX Status
-----------------
DCBX Operational Version is 0
DCBX Max Version Supported is 0
Sequence Number: 2
Acknowledgment Number: 2
Protocol State: In-Sync
Peer DCBX Status:
----------------
DCBX Operational Version is 0
DCBX Max Version Supported is 255
Sequence Number: 2
Acknowledgment Number: 2
Total DCBX Frames transmitted 27
Total DCBX Frames received 6
Total DCBX Frame errors 0
Total DCBX Frames unrecognized 0
The following table describes the show interface DCBx detail command elds.
Table 13. show interface DCBx detail Command Description
Field Description
Interface Interface type with chassis slot and port number.
Port-Role Congured DCBx port role: auto-upstream, auto-downstream,
cong-source, or manual.
DCBx Operational Status Operational status (enabled or disabled) used to elect a
conguration source and internally propagate a DCB
conguration. The DCBx operational status is the combination of
PFC and ETS operational status.
Conguration Source Species whether the port serves as the DCBx conguration
source on the switch: true (yes) or false (no).
Local DCBx Compatibility mode DCBx version accepted in a DCB conguration as compatible. In
auto-upstream mode, a port can only received a DCBx version
supported on the remote peer.
240
Data Center Bridging (DCB)