Administrator Guide
Figure 39. FIP Snooping on an MXL 10/40GbE Switch Conguration Example
• A server-facing port is congured for DCBx in an auto-downstream role.
• An FCF-facing port is congured for DCBx in an auto-upstream or conguration-source role.
The DCBx conguration on the FCF-facing port is detected by the server-facing port and the DCB PFC conguration on both ports
is synchronized. For more information about how to congure DCBx and PFC on a port, refer to the Data Center Bridging (DCB)
chapter.
The following example shows how to congure FIP snooping on FCoE VLAN 10, on an FCF-facing port (0/50), on an ENode server-
facing port (0/1), and to congure the FIP snooping ports as tagged members of the FCoE VLAN enabled for FIP snooping.
Example of Enabling the FIP Snooping Feature on the Switch (FIP Snooping Bridge)
Example of Enabling FIP Snooping on the FCoE VLAN
Example of Enabling an FC-MAP Value on a VLAN
Example of Conguring the ENode Server-Facing Port
Example of Conguring the FCF-Facing Port
Example of Conguring FIP Snooping Ports as Tagged Members of the FCoE VLAN
Dell(conf)# feature fip-snooping
314
FCoE Transit