Administrator Guide
• Target’s IP Address
• Initiator dened session identier (ISID)
• Initiator’s iSCSI qualied name (IQN)
• Target’s IQN
• Initiator’s TCP Port
• Target’s TCP Port
If no iSCSI trac is detected for a session during a user-congurable aging period, the session data is cleared.
Detection and Auto-Conguration for Dell EqualLogic Arrays
The iSCSI optimization feature includes auto-provisioning support with the ability to detect directly connected Dell EqualLogic
storage arrays and automatically recongure the switch to enhance storage trac ows.
The MXL uses the link layer discovery protocol (LLDP) to discover Dell EqualLogic devices on the network. LLDP is enabled by
default. For more information about LLDP, refer to Link Layer Discovery Protocol (LLDP).
The following message displays the rst time a Dell EqualLogic array is detected and describes the conguration changes that are
automatically performed:
%STKUNIT0-M:CP %IFMGR-5-IFM_ISCSI_AUTO_CONFIG: This switch is being configured for optimal
conditions to support iSCSI traffic which will cause some automatic configuration to occur
including jumbo frames and flow-control on all ports; no storm control and spanning-tree
port
fast to be enabled on the port of detection.
The following syslog message is generated the rst time an EqualLogic array is detected:
%STKUNIT0-M:CP %LLDP-5-LLDP_EQL_DETECTED: EqualLogic Storage Array detected on interface Te
1/43
• At the rst detection of an EqualLogic array, an MTU of 12000 is enabled on all ports and port-channels (if it has not already
been enabled).
• Spanning-tree portfast is enabled on the interface LLDP identies.
• Unicast storm control is disabled on the interface LLDP identies.
Conguring Detection and Ports for Dell Compellent Arrays
For the best iSCSI trac conditions, the MXL switch auto-congures a port connected to a Dell Compellent storage array, when
congured as compellent connected port through CLI.
The following message displays the rst time a Dell Compellent storage array is detected and describes the conguration changes
that are automatically performed:
%STKUNIT0-M:CP %IFMGR-5-IFM_ISCSI_AUTO_CONFIG: This switch is being configured for optimal
conditions to support iSCSI traffic which will cause some automatic configuration to occur
including jumbo frames and flow-control on all ports; no storm control and spanning-tree
port
fast to be enabled on the port of detection.
The MXL switch auto-congures as follows:
• At the rst detection, an MTU of 12000 is enabled on all ports and port-channels (if it is not already enabled).
• Spanning-tree portfast is enabled on the interface identied by CLI, if the port is in L2 mode.
• Unicast storm control is disabled on the interface identied by CLI.
iSCSI Optimization: Operation
iSCSI optimization requires LLDP to be enabled. LLDP is enabled by default on MXL switch.
When the MXL auto-congures with iSCSI enabled, the following actions occurs:
• Link-level ow control is enabled on PFC disabled interfaces.
• iSCSI session snooping is enabled.
416