Administrator Guide

Command Description
NOTE: Although the show interface status command displays the
Fiber Channel (FC) interfaces with the abbreviated label of 'Fc' in the
output, if you attempt to specify a FC interface by using the
interface fc command in the CLI interface, an error message is
displayed. You must congure FC interfaces by using the interface
fi command in CONFIGURATION mode.
show fcoe-map [brief | map-name]
Displays the Fibre Channel and FCoE conguration parameters in FCoE maps.
Enter the brief keyword to display an overview of currently congured FCoE
maps.
Enter the name of an FCoE map to display the FC and FCoE parameters
congured in the map to be applied on MXL 10/40GbE Switch or M I/O
Aggregator with the FC Flex IO module Ethernet (FCoE) and FC ports.
show qos dcb-map
map-name
Displays conguration parameters in a specied DCB map.
show npiv devices [brief]
Displays information on FCoE and FC devices currently logged in to the NPG.
show fc switch
Displays the FC mode of operation and worldwide node (WWN) name of an
MXL 10/40GbE Switch or M I/O Aggregator with the FC Flex IO module.
show interfaces status Command Example
Dell# show interfaces status
Port Description Status Speed Duplex Vlan
Fc 0/0 Up 8000 Mbit Auto --
Fc 0/1 Down Auto Auto --
Fc 0/2 Down Auto Auto --
Fc 0/3 Down Auto Auto --
Fc 0/4 Down Auto Auto --
Fc 0/5 Down Auto Auto --
Fc 0/6 Down Auto Auto --
Fc 0/7 Down Auto Auto --
Fc 0/8 Down Auto Auto --
Fc 0/9 Down Auto Auto --
Fc 0/10 Down Auto Auto --
Fc 0/11 Down Auto Auto --
Te 1/12 Down Auto Auto --
Te 1/13 Down Auto Auto --
Te 1/14 Down Auto Auto --
Te 1/15 Down Auto Auto --
Te 1/16 Down Auto Auto --
Te 1/17 Down Auto Auto --
Te 1/18 Down Auto Auto --
Te 1/19 Up 10000 Mbit Full --
Te 1/20 Down Auto Auto --
Te 1/21 Down Auto Auto --
Table 84. show interfaces status Field Descriptions
Field Description
Port Server-facing 10GbE Ethernet (Te), 40GbE Ethernet (Fo), or fabric-facing Fibre Channel
(Fc) port with slot/port information.
Description Text description of port.
Status Operational status of port:
FC Flex IO Modules
937