Command Line Reference Guide
1142 | Power over Ethernet (PoE)
www.dell.com | support.dell.com
Table 44-4 describes the nine possible power supply conditions.
S-Series
Example
Figure 44-2. show power supply (S-Series) Command Example
Table 44-4 describes the nine possible power supply conditions.
Table 44-3. Power Supply Conditions
AC Fail The PSU is unplugged.
Active The PSU is supplying power to the chassis.
Fail The PSU has failed.
Not Present The PSU is not installed in the chassis.
Over Current Shutdown The PSU has turned off due to an high input current condition.
Over Temperature Shutdown The PSU has turned off due to an high temperature condition.
Over Temperature Warning The temperature of the PSU is greater than the recommended maximum
operating temperature.
Over Current Warning The current being supplied to the PSU is greater than the recommended
maximum input current.
Power Off The PSU is present but not on.
Table 44-4. Power Supply Conditions
AC Fail The PSU is unplugged.
Active The PSU is supplying power to the chassis.
Fail The PSU has failed.
Not Present The PSU is not installed in the chassis.
Over Current Shutdown The PSU has turned off due to an high input current condition.
Over Temperature Shutdown The PSU has turned off due to an high temperature condition.
Over Temperature Warning The temperature of the PSU is greater than the recommended maximum
operating temperature.
Over Current Warning The current being supplied to the PSU is greater than the recommended
maximum input current.
Power Off The PSU is present but not on.
Force10#show power supply
Unit Power Model Type Status
Supply Number
----------------------------------------------------------------------
0 PS0 S50-PWR-AC AC Active
0 PS1 S50-PWR-DC DC Active
1 PS0 S50-PWR-AC AC Active
1 PS1 Not present
2 PS0 S50-PWR-AC AC Active
2 PS1 Not present
Force10