Command Line Reference Guide

142 | Control and Monitoring
www.dell.com | support.dell.com
Command
History
Usage
Figure 5-55
shows the output from the show system brief command.
Figure 5-56 shows the output from the show system stack-unit command.
Example
Figure 5-55. Command Example: show system brief
Version 7.8.1.0 Modified output: Boot Flash field will display code level for boot code 2.8.1.1 and newer,
while older boot codes are displayed as "Present".
Version 7.7.1.0 Modified output: Added Master Priority field.
Version 7.6.1.0 Introduced for S-Series switches
Force10#show system brief
Stack MAC : 0:1:e8:d6:4:70
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------
0 Member not present
1 Standby online S50V S50V 7.7.1.0 52
2 Mgmt online S50V S50V 7.7.1.0 52
3 Member not present
4 Member not present
5 Member not present
6 Member not present
7 Member not present
-- Module Info --
Unit Module No Status Module Type Ports
---------------------------------------------------------------------------
1 0 online S50-01-10GE-2P 2
1 1 online S50-01-24G-2S 1
2 0 online S50-01-10GE-2P 2
2 1 online S50-01-24G-2S 1
-- Power Supplies --
Unit Bay Status Type
---------------------------------------------------------------------------
1 0 up AC
1 1 absent
2 0 up AC
2 1 absent
-- Fan Status --
Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
--------------------------------------------------------------------------------
1 up up up up up up up
2 up up up up up up up
Force10#