Command Line Reference Guide
Control and Monitoring | 143
Example
Figure 5-56. Command Example: show system stack-unit
Related
Commands
Force10#show system stack-unit 0
-- Unit 0 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S50V - 48-port E/FE/GE with POE (SB)
Current Type : S50V - 48-port E/FE/GE with POE (SB)
Master Priority : 4
Hardware Rev : 2.0
Num Ports : 52
Up Time : 3 hr, 17 min
FTOS Version : 7.6.1.0a
Jumbo Capable : yes
POE Capable : no
Boot Flash : Present
Memory Size : 254701568 bytes
Temperature : 43C
Voltage : ok
Serial Number : DZ267160000
Part Number : 7590003600 Rev B
Vendor Id : 07
Date Code : 12172007
Country Code : 01
Burned In MAC : 00:01:e8:cc:cc:cc
No Of MACs : 3
--Module 0--
Status : online
Module Type : S50-01-10GE-2P - 2-port 10GE XFP (SB)
Num Ports : 2
Hot Pluggable : no
-- Module 1 -
Status : online
Module Type : S50-01-10GE-2C - 2-port 10GE CX4 (SB)
Num Ports : 2
Hot Pluggable : no
- Power Supplies --
Unit Bay Status Type
---------------------------------------------------------------------------
0 0 up AC
0 1 absent
-- Fan Status --
--------------------------------------------------------------------------------
Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
0 up up up up up up up
Force10#
show version Display the FTOS version.
show processes memory
(S-Series)
Display memory usage based on running processes.
show system stack-ports Display information about the stack ports on all switches in the S-Series
stack.
show hardware stack-unit Display the data plane and management plane input and output statistics of a
particular stack member.
stack-unit priority Configure the ability of an S-Series switch to become the management unit
of a stack.