Command Line Reference Guide
E-Series ExaScale Debugging and Diagnostics | 1555
Offline Diagnostic Commands
Offline diagnostics are not supported in FTOS version
8.1.1.0.
The offline diagnostics test suite is useful for isolating faults and debugging hardware. The tests results
are written to a file in flash memory and can be displayed on screen. Detailed statistics for all tests are
collected.
These statistics include:
• last execution time
• first test pass time and last test pass time
• first test failure time and last test failure time
• total run count
• total failure count
• consecutive failure count
• error code
The offline diagnostics commands are:
• diag linecard
• offline
• online
• show diag
diag linecard
Not supported in FTOS version 8.1.1.0
e
x
Run offline diagnostics on a line card(s).
Syntax
diag linecard number {alllevels | level0 | level1 | level2} | {terminate}
To terminate the offline diagnostics, use the diag linecard number terminate command.
Parameters
show environment (C-Series
and E-Series)
Display
system component status.
show processes memory
(C-Series and E-Series)
Display memory usage based on running processes.
number
Enter the line card slot number.
Range: 0 to 13 on a E1200, 0 to 6 on a E600, and 0 to 5 on a E300.
alllevels
Enter the keyword
alllevels to run the complete offline diagnostic test.
level0
Enter the keyword
level0 to check the device inventory and verify the
existence of the devices.