Command Line Reference Guide
1556 | E-Series ExaScale Debugging and Diagnostics
www.dell.com | support.dell.com
Defaults
All Levels (alllevels)
Command Modes
EXEC
EXEC Privilege
Command
History
offline
Not supported in FTOS version 8.1.1.0
e
x
Place a line card in an offline state.
Syntax
offline {linecard number}
Parameters
Defaults
No default behavior or values
Command Mode
EXEC
EXEC Privilege
Command
History
online
Not supported in FTOS version 8.1.1.0
e
x
Place a line card in an online state.
Syntax
online {linecard number | rpm number}
Parameters
level1
Enter the keyword
Level1 to verify that the devices are accessible via the
designated paths (line integrity tests) and test the internal registers of the
devices.
level2
Enter the keyword
level2 to perform on-board loopback tests on various
data paths (data Port-Pipe and Ethernet).
terminate
Enter the keyword terminate to stop the offline diagnostics tests.
Version 8.1.1.2 Introduced on E-Series ExaScale E600i
Version 8.1.1.0 Introduced on E-Series ExaScale E1200i
linecard number Enter the keyword linecard followed by the line card slot number.
Range: 0 to 13 on a E1200, 0 to 6 on a E600, and 0 to 5 on a E300.
Version 8.1.1.2 Introduced on E-Series ExaScale E600i
Version 8.1.1.0 Introduced on E-Series ExaScale E1200i
linecard number Enter the keyword linecard followed by the line card slot number.
Range: 0 to 13 on a E1200, 0 to 6 on a E600, and 0 to 5 on a E300.