Command Line Reference Guide

Control and Monitoring | 97
Figure 5-8. Command Example: ping (IPv6)
power-off
c e
Turn off power to a selected line card or the standby (extra) Switch Fabric Module (SFM).
Syntax
power-off {linecard number | sfm sfm-slot-id}
Parameters
Defaults
Disabled
Command Modes
EXEC Privilege
Command
History
Related
Commands
power-on
c e
Turn on power to a line card or the standby (extra) Switch Fabric Module (SFM).
Syntax
power-on {linecard number | sfm sfm-slot-id}
Parameters
Force10#ping 100::1
Type Ctrl-C to abort.
Sending 5, 100-byte ICMP Echos to 100::1, timeout is 2 seconds:
!!!!!
Success rate is 100.0 percent (5/5), round-trip min/avg/max = 0/0/0 (ms)
Force10#
linecard number Enter the keyword linecard and a number for the line card slot number.
C-Series Range: 0 to 7
E-Series Range: 0 to 13 on a E1200/E1200i, 0 to 6 on a E600/E600i, and 0 to 5 on a
E300.
sfm sfm-slot-id Enter the keyword sfm by the slot number of the SFM to which you want to turn
off power.
Note: This option is supported on E-Series only.
Version 8.1.1.2 Introduced on E-Series ExaScale E600i
Version 8.1.1.0 Introduced on E-Series ExaScale E1200i
Version 7.5.1.0 Introduced on C-Series
E-Series original Command
power-on Power on a line card or standby SFM.
linecard number Enter the keyword linecard and a number for the line card slot number.
C-Series Range: 0-7
E-Series Range: 0 to 13 on a E1200/E1200i, 0 to 6 on a E600/E600i, and 0 to 5 on a
E300.
sfm standby Enter the keyword sfm followed by the slot number of the SFM to power on.
Note: This option is supported on E-Series only.