Reference Guide

Storm Control | 1125
Example
Figure 41-2. show storm-control broadcast Command Example (C-Series)
show storm-control multicast
c s z
Display the storm control multicast configuration.
Syntax
show storm-control multicast [interface]
Parameters
Defaults
No default behavior or values
Command Modes
EXEC
EXEC Privilege
Command
History
Example
Figure 41-3. show storm-control multicast Command Example
FTOS#show storm-control broadcast gigabitethernet 3/24
Broadcast storm control configuration
Interface Direction Packets/Second
-----------------------------------------------
Gi 3/24 Ingress 1000
FTOS#
interface
(OPTIONAL) Enter one of the following interfaces to display the interface specific storm
control configuration.
For Fast Ethernet, enter the keyword
Fastethernet followed by the slot/port
information.
For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed by
the slot/port information.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet followed
by the slot/port information.
Version 8.3.11.1 Introduced on Z9000
Version 7.6.1.0 Introduced on C-Series and S-Series
FTOS#show storm-control multicast gigabitethernet 1/0
Multicast storm control configuration
Interface Direction Packets/Second
-----------------------------------------------
Gi 1/0 Ingress 5
FTOS#