Reference Guide

Control and Monitoring | 137
Usage
Figure 4-52 shows the output from the show system brief command.
Figure 4-53 shows the output from the show system stack-unit command on a Z9000
system.
Figure 4-52shows the output from the show system stack-unit command on an S4810.
Example
Figure 4-52. Command Example: show system brief
FTOS#show system brief
Stack MAC : 0:1:e8:d6:4:70
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
-------------------------------------------------------------------------
--
0 Member not present
1 Standby online S50V S50V 7.7.1.0 52
2 Mgmt online S50V S50V 7.7.1.0 52
3 Member not present
4 Member not present
5 Member not present
6 Member not present
7 Member not present
-- Module Info --
Unit Module No Status Module Type Ports
-------------------------------------------------------------------------
--
1 0 online S50-01-10GE-2P 2
1 1 online S50-01-24G-2S 1
2 0 online S50-01-10GE-2P 2
2 1 online S50-01-24G-2S 1
-- Power Supplies --
Unit Bay Status Type
-------------------------------------------------------------------------
--
1 0 up AC
1 1 absent