Reference Guide

Interfaces | 569
The only configuration applicable to half duplex ports is rx off tx off. The following error is
returned:
Can’t configure flowcontrol when half duplex is configure,
config ignored
Half duplex cannot be configured when the flow control configuration is on (default is rx on tx
on
). The following error is returned:
Can’t configure half duplex when flowcontrol is on, config
ignored
Speeds less than 1 Gig cannot be configured when the asymmetric flow control configuration is
on. The following error is returned:
Can’t configure speed <1G when Asymmetric flowcontrol is on,
config ignored
FTOS only supports rx on tx on and rx off tx off for speeds less than 1 Gig (Symmetric).
On the C-Series and S-Series systems, the flow-control sender and receiver must be on the same
port-pipe. Flow control is not supported across different port-pipes on the C-Series or S-Series
system.
Example
Figure 18-4. show running config (partial)
Note: The flow control must be off (rx off tx off) before configuring the half duplex.
FTOS(conf-if-gi-0/1)#show config
!
interface GigabitEthernet 0/1
no ip address
switchport
no negotiation auto
flowcontrol rx off tx on
no shutdown
...