Reference Guide

Control and Monitoring | 73
Command Modes
CONFIGURATION
Command
History
Usage
Information
The chassis MIB contain the entry chSysXfpRecvPower in the chSysPortTable table.
Periodically, IFA polls the XFP power for each of the ports, and sends the values to IFM
where it is cached. The default interval for the polling is 300 seconds (5 minutes). Use this
command to enable the polling and to configure the polling frequency.
end
c e s z
Return to the EXEC Privilege mode from other command modes (for example, the
CONFIGURATION or ROUTER OSPF modes).
Syntax
end
Command Modes
CONFIGURATION, SPANNING TREE, MULTIPLE SPANNING TREE, LINE,
INTERFACE, TRACE-LIST, VRRP, ACCESS-LIST, PREFIX-LIST, AS-PATH ACL,
COMMUNITY-LIST, ROUTER OSPF, ROUTER RIP, ROUTER ISIS, ROUTER BGP
Command
History
Related
Commands
epoch
e
Set the epoch scheduling time for the chassis.
Syntax
epoch {2.4 |3.2 | 10.4}
To return to the default setting, enter no epoch.
Version 8.3.11.4 Deprecated command for Z9000 only. Replaced by the enable
optic-info-update interval
command to update information on
temperature and power monitoring in the SNMP MIB.
Version 8.3.11.1 Introduced on the Z9000
Version 8.3.10.0 Deprecated command for S4810. Replaced by the enable optic-info-update
interval command to update information on temperature and power
monitoring in the SNMP MIB.
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series and E-Series
Version 8.3.11.1 Introduced on the Z9000
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
E-Series original Command
exit Return to the lower command mode.