Reference Guide

Control and Monitoring | 87
module power-off
c e
Turn off power to a line card at next reboot.
Syntax
module power-off linecard number
To remove the command from the running configuration, use the no module power-off
linecard
number command.
Parameters
Defaults
Not configured.
Command Modes
CONFIGURATION
Command
History
motd-banner
c e s z
Enable a Message of the Day (MOTD) banner to appear when you log in to the system.
Syntax
motd-banner
To disable the MOTD banner, enter no motd-banner.
Defaults
Enabled on all lines.
Command Modes
LINE
Command
History
ping
c e s z
Test connectivity between the system and another device by sending echo requests and
waiting for replies.
linecard number Enter the keyword line card followed by the line card slot number
C-Series Range: 0-7
E-Series Range: 0 to 13 on a E1200/1200i, 0 to 6 on a E600/E600i, and 0
to 5 on a E300.
Version 8.1.1.2 Introduced on E-Series ExaScale E600i
Version 8.1.1.0 Introduced on E-Series ExaScale E1200i
Version 7.5.1.0 Introduced on C-Series
E-Series original Command
Version 8.3.11.1 Introduced on the Z9000
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
E-Series original Command