Reference Guide

Control and Monitoring | 93
Defaults
Disabled.
Command Modes
EXEC Privilege
Command
History
Usage
Information
The command reset without any options is a soft reset, which means FTOS boots the line
card from its runtime image. The hard option reloads the FTOS image on the line card. Use
the power-cycle after upgrading an FPGA.
When a soft reset is issued on a line card (reset linecard
number), FTOS boots the line card
from its runtime image. Only when you enter reset linecard
number hard is the software
image reloaded on the line card.
Related
Commands
rpm <slot> location-led
e
x
Toggle the location LED on/off on the E-Series ExaScale RPM (LC-EH-RPM).
Syntax
rpm slot number location-led [on | off]
Parameters
Defaults
OFF
Command Modes
EXEC
Command
History
Usage
Information
The LED setting is not saved through power cycles.
sfm standby Enter the keyword sfm standby to reset the standby SFM.
Note: This option is supported on E-Series EtherScale only.
sfm slot number Enter the keyword sfm followed by the failed or powered-off SFM slot
number.
Note: Supported on E-Series only
Version 7.5.1.0 Introduced on C-Series
E-Series original Command
reload Reboots the system.
Upgrading the
C-Series FPGA
Copy the backup C-Series FPGA image to the primary FPGA image.
rpm slot number Enter the slot number
E1200i: 0-13
E600i: 0-6
on |off Toggles the LED on the RPM on or off.
Version 8.2.1.0 Introduced on the E-Series ExaScale