Administrator Guide

Table Of Contents
Use the no seq sequence-number command if you know the filter’s
sequence number.
Use the no permit udp {source mask | any | host ip-address}
{destination mask | any | host ip-address command.
Parameters
source Enter the IP address of the network or host from which the
packets were sent.
mask Enter a network mask in /prefix format (/x) or A.B.C.D. The
mask, when specified in A.B.C.D format, may be either
contiguous or non-contiguous.
any Enter the keyword any to specify that all routes are subject
to the filter.
host ip-address Enter the keyword host and then enter the IP address to
specify a host IP address.
dscp Enter the keyword dscp to deny a packet based on the
DSCP value. The range is from 0 to 63.
operator (OPTIONAL) Enter one of the following logical operand:
eq = equal to
neq = not equal to
gt = greater than
lt = less than
range = inclusive range of ports (you must specify two
ports for the port parameter)
port port Enter the application layer port number. Enter two port
numbers if you are using the range logical operand. The
range is 0 to 65535.
destination Enter the IP address of the network or host to which the
packets are sent.
count (OPTIONAL) Enter the keyword count to count packets
processed by the filter.
byte (OPTIONAL) Enter the keyword byte to count bytes
processed by the filter.
log (OPTIONAL, E-Series only) Enter the keyword log to have
the information kept in an ACL log file.
order (OPTIONAL) Enter the keyword order to specify the QoS
priority for the ACL entry. The range is from 0 to 254 (where
0 is the highest priority and 254 is the lowest; lower-order
numbers have a higher priority). If you do not use the
keyword order, the ACLs have the lowest order by default
(255).
monitor (OPTIONAL) Enter the keyword monitor when the rule is
describing the traffic that you want to monitor and the ACL
206
Access Control Lists (ACL)