Reference Guide

Defaults
update = 30 seconds
invalid = 180 seconds
holddown = 180 seconds
flush = 240 seconds
Command Modes ROUTER RIP
Command History
This guide is platform-specific. For command information about other platforms, refer to the
relevant
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.8.1.0 Introduced on the S-Series.
Version 7.6.1.0 Introduced on the C-Series.
pre-Version
6.2.1.1
Introduced on the E-Series.
Usage
Information
If you change the timers on one router, also synchronize the timers on all routers in the RIP
domain.
version
Specify either RIP version 1 or RIP version 2.
Z9000
Syntax
version {1 | 2}
To return to the default version setting, use the no version command.
Parameters
1 Enter the keyword 1 to specify RIP version 1.
2 Enter the keyword 2 to specify RIP version 2.
Defaults The FTOS sends RIPv1 and receives RIPv1 and RIPv2.
Command Modes ROUTER RIP
Command History
This guide is platform-specific. For command information about other platforms, refer to the
relevant
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
Version 8.3.19.0 Introduced on the S4820T.
1188