Reference Guide

sflow collector
Configure a collector device to which sFlow datagrams are forwarded.
Z-Series
Syntax
sflow collector {ip-address | ipv6-address} agent-addr {ip-
address | ipv6-address} [number [max-datagram-size number]] |
[max-datagram-size number]
To delete a configured collector, use the no sflow collector {ip-address |
ipv6-address} agent-addr {ipv4-address | ipv6-address} [number
[max-datagram-size number]] | [max-datagram-size number] command.
Parameters
sflow collector
ip-address
|
ipv6-
address
Enter the IP address of the collector in dotted decimal format for IPv4
or x:x:x:x::x format for IPv6.
NOTE: The :: notation specifies successive hexadecimal fields of
zeros.
agent-addr
ip-
address
|
ipv6-
address
Enter the keyword agent-addr followed by the sFlow agent IP
address in dotted decimal format for IPv4 or x:x:x:x::x format for IPv6.
NOTE: The :: notation specifies successive hexadecimal fields of
zeros.
number
(OPTIONAL) Enter the user datagram protocol (UDP) port number. The
range is from 0 to 65535. The default is 6343.
max-datagram-
size
number
(OPTIONAL) Enter the keyword max-datagram-size then the size
number in bytes. The range is from 400 to 1500. The default is 1400.
Defaults Not configured.
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, refer to the
relevant
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.4.2.3 Added support for IPv6 sFlow collectors and agents on the E-series
TeraScale, C-Series, and S-Series.
Version 8.4.1.1 Added support for IPv6 sFlow collectors and agents on the E-series
ExaScale.
Version 8.3.7.0 Introduced on the S4810.
Version 8.2.1.0 Introduced S-Series Stacking.
Version 8.1.1.0 Introduced on the E-Series ExaScale.