Usage
Information
When you have exhausted all the sequence numbers, this feature permits re-assigning a new
sequence number to entries of an existing access-list.
Related
Commands
resequence prefix-list ipv4 — resequences a prefix list.
resequence prefix-list ipv4
Re-assign sequence numbers to entries of an existing prefix list.
Z9000
Syntax
resequence prefix-list ipv4 {prefix-list-name StartingSeqNum
Step-to-increment}
Parameters
prefix-list-name
Enter the name of the configured prefix list, up to 140 characters long.
StartingSeqNum
Enter the starting sequence number to resequence. The range is from
0 to 65535.
Step-to-
Increment
Enter the step to increment the sequence number. The range is from 1
to 65535.
Defaults none
Command Modes
EXEC
EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, refer to the
relevant
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.1.1.0 Introduced on the E-Series ExaScale