Reference Guide

leave-all Enter the keywords leave-all then the number of milliseconds to
configure the leave-all time. The range is from 100 to 2147483647
milliseconds. The default is 1000 milliseconds.
NOTE: Designate the milliseconds in multiples of 100.
Defaults As above.
Command Modes CONFIGURATION-GVRP
Command History
This guide is platform-specific. For command information about other platforms, refer to the
relevant
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.6.1.0 Introduced on C-Series, E-Series, and S-Series
Usage
Information
Join Timer — Join messages announce the willingness to register some attributes
with other participants. For reliability, each GARP application entity sends a Join
message twice and uses a join timer to set the sending interval.
Leave Timer — Leave announces the willingness to de-register with other
participants. Together with Join, Leave messages help GARP participants complete
attribute reregistration and de-registration. The leave timer starts after receipt of a
leave message sent for de-registering some attribute information. If a
Join message
is
not
received before the Leave time expires, the GARP application entity removes
the attribute information as requested.
Leave All Timer — The Leave All timer starts when a GARP application entity
starts. When this timer expires, the entity sends a
Leave-all message so that other
entities can reregister their attribute information. Then the Leave-all time begins
again.
Related
Commands
show garp timers — displays the current GARP times.
gvrp enable
Enable GVRP on physical interfaces and LAGs.
Z9000
Syntax
gvrp enable
To disable GVRP on the interface, use the no gvrp enable command.
Defaults Disabled.
457