Reference Guide

- advisable to shut
directly connected ports
Proceed with Diags [confirm yes/no]: yes
00:03:35: %S50N:1 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on stack unit 1
00:03:35 : Approximate time to complete these Diags ... 6 Min
S50N#00:09:32 : Diagnostic test results are stored on file: flash:/TestReport-
SU-0.txt
00:09:37: %S50N:0 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack unit 0
Diags completed... Rebooting the system now!!!
[reboot output omitted]
S50N#00:01:35: %STKUNIT0-M:CP %SYS-5-CONFIG_I: Configured from console by
console
dir
Directory of flash:
1 drw- 16384 Jan 01 1980 00:00:00 +00:00 .
2 drwx 1536 Feb 29 1996 00:05:22 +00:00 ..
3 drw- 512 Aug 15 1996 23:09:48 +00:00 TRACE_LOG_DIR
4 d--- 512 Aug 15 1996 23:09:52 +00:00 ADMIN_DIR
5 -rw- 3854 Sep 24 1996 03:43:46 +00:00 startup-config
6 -rw- 12632 Nov 05 2008 17:15:16 +00:00 TestReport-SU-1.txt
flash: 3104256 bytes total (3086336 bytes free)
flash: 3001958400 bytes total (2716000256 bytes free)
Dell#show file flash://TestReport-SU-0.txt
CPU Version : Intel I386
Stack Unit Board temperatur : 49 Degree C
Stack Unit Number : 0
Serial Number : Z8FX122P00109
Part Number : 7520057401
Product Revision : H
Version : E9-0-0-23
**************************** Z9000 LEVEL 0 DIAGNOSTICS**************************
+ TEST - 1
PSU [0] STATUS ---> POWER ON
PSU [0] STATUS ---> POWER OK
PSU [0] STATUS ---> PSU OK
Test 1.000 - Psu status monitor test ................................ PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuStatusMonitorTest[96]: ERROR: Getting PSU -1 power status failed..
Test 1.001 - Psu status monitor test ................................ FAIL
Test 1 - Psu status monitor test .................................... FAIL
+ TEST - 2
PSU [0] Voltage Val ---> 12
Test 2.000 - Psu voltage read test .................................. PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuVoltageReadTest[188]: ERROR: Getting PSU -1 power status failed..
Test 2.001 - Psu voltage read test .................................. FAIL
Test 2 - Psu Voltage Read Test ..................................... FAIL
+ TEST - 3
PSU [0] Temperature ---> 45 Degree Celcius
Test 3.000 - Psu temperature read test .............................. PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuTemperatureTest[258]: ERROR: Getting PSU -1 power status failed..
Test 3.001 - Psu temperature read test .............................. FAIL
Test 3 - Psu Temperature Test ...................................... FAIL
+ TEST - 4
PSU [0] Fan Speed ---> 17441 RPM
900
Z-Series Debugging and Diagnostics