Reference Guide

Parameters
normal (OPTIONAL) Enter the keyword normal to change the link
state to “unknown” when a far-end failure the software
detects on that interface. When the interface is placed in
“unknown” state, the software brings down the line protocol.
aggressive (OPTIONAL) Enter the keyword aggressive to change the
link state to “error-disabled” when a far-end failure the
software detects on that interface. When an interface is
placed in “error-disabled” state, enter the
fefd reset
command to reset the interface state.
Defaults normal
Command
Modes
INTERFACE
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version
8.3.19.0
Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Legacy E-
Series
command.
Related
Commands
fefd — enables far-end failure detection.
fefd reset
Reset all interfaces or a single interface that was in “error-disabled” mode.
Z9000
Syntax
fefd reset [interface]
Parameters
interface (OPTIONAL) Enter the following keywords and slot/port or
number information:
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE then the slot/ port information.
Layer 2
949