Addendum

Related
Commands
clear logging — clears the logging buffer.
default logging console — returns the logging console parameters to the default
setting.
show logging — displays the logging setting and system messages in the internal
buffer.
logging monitor
Specify which messages are logged to Telnet applications.
Z-Series S4810 S4820T
Syntax
logging monitor [level]
To disable logging to terminal connections, use the no logging monitor
command.
Parameters
level Indicate a value from 0 to 7 or enter one of the following
parameters: emergencies, alerts, critical, errors,
warnings, notifications, informational, or
debugging. The default is 7 or debugging.
Defaults 7 or debugging
Command
Modes
CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant FTOS Command Line Reference Guide.
The following is a list of the FTOS version history for this command.
Version 9.2(0.0) Introduced on the M I/O Aggregator. This command is
supported in Programmable-Mux (PMUX) mode only.
Version
8.3.19.0
Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
E-Series legacy
command
Related
Commands
default logging monitor — returns the logging monitor parameters to the default
setting.
420
Simple Network Management Protocol (SNMP) and Syslog