Configuration manual

PSU [0] STATUS ---> POWER ON
PSU [0] STATUS ---> POWER OK
PSU [0] STATUS ---> PSU OK
Test 1.000 - Psu status monitor test ................................ PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuStatusMonitorTest[96]: ERROR: Getting PSU -1 power status failed..
Test 1.001 - Psu status monitor test ................................ FAIL
Test 1 - Psu status monitor test .................................... FAIL
+ TEST - 2
PSU [0] Voltage Val ---> 12
Test 2.000 - Psu voltage read test .................................. PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuVoltageReadTest[188]: ERROR: Getting PSU -1 power status failed..
Test 2.001 - Psu voltage read test .................................. FAIL
Test 2 - Psu Voltage Read Test ..................................... FAIL
+ TEST - 3
PSU [0] Temperature ---> 45 Degree Celcius
Test 3.000 - Psu temperature read test .............................. PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuTemperatureTest[258]: ERROR: Getting PSU -1 power status failed..
Test 3.001 - Psu temperature read test .............................. FAIL
Test 3 - Psu Temperature Test ...................................... FAIL
+ TEST - 4
PSU [0] Fan Speed ---> 17441 RPM
Test 4.000 - Psu Fan Speed Monitor Test ............................. PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuFanSpeedMonitorTest[378]: ERROR: Getting PSU -1 power status
failed..
Test 4.001 - Psu Fan Speed Monitor Test ............................. FAIL
Test 4 - Psu Fan Speed Monitor Test ................................ FAIL
+ TEST - 5
PSU [0] Source Type --> AC
Test 5.000 - Psu Source type test ................................... PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuSourceTypeTest[517]: ERROR: Getting PSU -1 power status failed..
Test 5.001 - Psu Source type test ................................... FAIL
Test 5 - Psu Source Type Test ...................................... FAIL
+ TEST - 6
PSU [0] Fan FLOW Type Normal (IO --> Rear)
Test 6.000 - Psu Fan module type detect test ........................ PASS
diagS3240GetPsuOnStatus[580]: ERROR: PSU-1 is not present...
diagS3240PsuFanModuleTypeDetectTest[448]: ERROR: Getting PSU -1 power status
failed.
The following example shows how to run offline diagnostics in Debug mode.
NOTE: Dell Networking highly recommends reloading the system after running the offline
diagnostics in Debug mode.
Dell#diag stack-unit 0 level0 verbose no-reboot
Warning - diagnostic execution will cause multiple link flaps on the peer side
- advisable to shut
directly connected ports
Warning - It is highly recommended to reboot the system after Offline
Diagnostics
Proceed with Diags [confirm yes/no]: y
00:37:32: %Z9000:0 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on stack unit 0
Dell#00:37:32 : Approximate time to complete the Diags ... 1 Min 30 Sec
Dell#
WARNING: Reboot is highly recommended after running Offline Diagnostics in
Debug Mode. Debug Mode can be
used only for troubleshooting specific test issue.
Z-Series Debugging and Diagnostics
907