Command Line Reference Guide

event owner: 1
event status: OK
Dell#
Example (Brief)
Dell#show rmon event br
index description
------------------------------
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
Dell#
show rmon hc-alarm
Display the contents of RMON High-Capacity alarm table.
Syntax
show rmon hc-alarm [index] [brief]
Parameters
index (OPTIONAL) Enter the table index number to display just that
entry.
brief (OPTIONAL) Enter the keyword brief to display the RMON
High-Capacity alarm table in an easy-to-read format.
Defaults none
Command
Modes
EXEC
Command
History
Version 8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Example
(Index)
Dell#show rmon hc-alarm 1
RMON high-capacity alarm entry 1
object: 1.3.6.1.2.1.1.3
sample interval: 5
sample type: absolute value.