Command Line Reference Guide

Field Description
FDISC - ENode logged in using a fabric discovery (FDISC).
Status Operational status of the link between a server CNA port
and a SAN fabric: Logged In - Server has logged in to the
fabric and is able to transmit FCoE traffic.
Example
Dell# show npiv devices brief
Total NPIV Devices = 2
---------------------------------------------------------------
----------------------------
ENode-Intf ENode-WWPN FCoE-Vlan Fabric-Intf
Fabric-Map LoginMethod Status
---------------------------------------------------------------
---------------------------
Te 0/12 20:01:00:10:18:f1:94:20 1003 Fc 0/5
fid_1003 FLOGI LOGGED_IN
Te 0/13 10:00:00:00:c9:d9:9c:cb 1003 Fc 0/0
fid_1003 FDISC LOGGED_IN
Usage
Information
The following table describes the show npiv devices output shown in the
example below.
Field Description
ENode [number] A server CNA that has successfully logged in to a fabric over
an M I/O Aggregator and MXL 10/40GbE Switch with the FC
Flex IO module Ethernet port in ENode mode.
Enode MAC MAC address of a server CNA port.
Enode Intf Port number of a server-facing Ethernet port operating in
ENode mode.
FCF MAC Fibre Channel forwarder MAC: MAC address of M I/O
Aggregator and MXL 10/40GbE Switch with the FC Flex IO
module FCF interface.
Fabric Intf Fabric-facing Fibre Channel port (slot/port) on which FCoE
traffic is transmitted to the specified fabric.
FCoE VLAN ID of the dedicated VLAN used to transmit FCoE traffic from
a server CNA to a fabric and configured on both the server-
facing M I/O Aggregator and MXL 10/40GbE Switch with the
FC Flex IO module port and server CNA port.
Fabric Map Name of the FCoE map containing the FCoE/FC
configuration parameters for the server CNA-fabric
connection.
Enode WWPN Worldwide port name of the server CNA port.
Enode WWNN Worldwide node name of the server CNA.
FC Flex IO Modules
1419