Configuration manual

Step Task Command Command Mode
1
Configure a fabric-facing FC port.
interface
fibrechannel slot/
port
CONFIGURATION
2
Apply the FCoE and FC fabric configurations in
an FCoE map to the port. Repeat this step to
apply an FCoE map to more than one FC port,
for example:
Dell# interface fi 0/0Dell(config-
if-fc-0/0)# fabric SAN_FABRIC_A
fabric
map-name
INTERFACE
FIBRE_CHANNEL
3
Enable the port for FC transmission.
no shutdown
INTERFACE
FIBRE_CHANNEL
Tip: You can apply a DCB or FCoE map to a range of Ethernet or Fibre Channel interfaces by using
theinterface range command; for example:
Dell(config)# interface range tengigabitEthernet 1/12 - 23 , tengigabitEthernet
2/24 - 35
Dell(config)# interface range fibrechannel 0/0 - 3 , fibrechannel 0/8 - 11
Enter the keywords interface range followed by an interface type and port range. A port range must
contain spaces before and after the dash. Separate each interface type and port range with a space,
comma, and space as shown in the preceding examples.
Sample Configuration
1. Configure a DCB map with PFC and ETS settings:
Dell(config)# dcb-map SAN_DCB_MAP
Dell(config-dcbx-name)# priority-group 0 bandwidth 60 pfc off
Dell(config-dcbx-name)# priority-group 1 bandwidth 20 pfc on
Dell(config-dcbx-name)# priority-group 2 bandwidth 20 pfc on
Dell(config-dcbx-name)# priority-group 4 strict-priority pfc off
Dell(conf-dcbx-name)# priority-pgid 0 0 0 1 2 4 4 4
2. Apply the DCB map on a downstream (server-facing) Ethernet port:
Dell(config)# interface tengigabitethernet 1/0
Dell(config-if-te-0/0)#dcb-map SAN_DCB_MAP
3. Create the dedicated VLAN to be used for FCoE traffic:
Dell(conf)#interface vlan 1002
4. Configure an FCoE map to be applied on downstream (server-facing) Ethernet and upstream (core-
facing) FC ports:
Dell(config)# fcoe-map SAN_FABRIC_A
1038