Users Guide

148
Dell™ Printer Configuration Web Tool
MIFARE Customized Card
NOTE:
MIFARE Customized Card feature is available on the Dell Cloud Multifunction Printer | H815dw only.
Purpose:
To register SSFC formatted NFC ID cards.
Va lu e s:
Printer Maintenance
The Printer Maintenance tab includes the Paper Density, Adjust Transfer Unit, Adjust Fusing Unit, Adjust
Density, Chart, Clean Developer, Clean Transfer Unit, Reset Defaults, Initialize PrintMeter, Storage, Non-Dell
Tone r, Adjust Altitude, Decrease Electrostatic Memory, Decrease Ghosting, Clock Settings, and Web Link
Customization pages.
Paper Density
Purpose:
To specify the paper density.
Va lu e s:
Adjust Transfer Unit
Purpose:
To specify the optimum voltage settings for printing for the transfer unit. To lower the voltage, set negative values.
To increase, set positive values.
The default settings may not give the best output quality on all paper types. If you see mottles on the printed paper,
try to increase the voltage. If you see white spots on the printed paper, try to decrease the voltage.
CAUTION:
The print quality changes depending on the setting values you select for this item.
Va lu e s:
User ID Block 1 Allows you to register the MIFARE Customized Card.
User ID Block 2 Allows you to register the MIFARE Customized Card.
User ID Block 3 Allows you to register the MIFARE Customized Card.
Plain Sets the density of plain paper to Light (<81g/m
2
) or Normal.
Plain(60-80g/m
2
) Sets the reference voltage setting for the transfer unit for plain paper within the range of -5 to 10.
Plain Thick(81-
105g/m
2
)
Sets the reference voltage setting for the transfer unit for thick plain paper within the range of -5 to
10.
Covers(106-163 g/m
2
) Sets the reference voltage setting for the transfer unit for cover paper within the range of -5 to 10.
Covers Thick
(164-216 g/m
2
)
Sets the reference voltage setting for the transfer unit for thick cover paper within the range of -5 to
10.
Rough Surface Sets the reference voltage setting for the transfer unit for rough surface paper within the range of -5 to
10.
Label Sets the reference voltage setting for the transfer unit for labels within the range of -5 to 10.
Envelope Sets the reference voltage setting for the transfer unit for envelopes within the range of -5 to 10.
Japanese Postcard Sets the reference voltage setting for the transfer unit for Japanese postcards within the range of -5 to
10.