White Papers

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities
40
A.1.1. NSS-HA cluster specification
The section gives a detailed specification for constructing an NSS-HA solution, including:
IP addresses and hostnames for the two R710 servers
10GbE / IPoIB IP addresses for the two R710 servers
iDRAC IP addresses, login names, and passwords
APC PDU IP addresses, login names, passwords, and ports used by the two R710 servers
Logical volume names, volume group names, and XFS file system mount points
NFS IP addresses used to mount NFS
Scripts for cluster
The configuration specified in this section will be used later in the recipe to construct the HA-cluster.
Any deviation from this configuration should be noted carefully since it require corresponding changes
in the cluster configuration script file later in the recipe. This section is provided as a reference of all
the configuration details.
Gigabit Ethernet IP addresses for the private network between the servers and the PDUs.
R710 (hostname: active)
NIC port 1 IP: 15.15.10.1/24
R710 (hostname: passive)
NIC port 1 IP: 15.15.10.2/24
iDRAC (installed on active)
15.15.10.201/24
iDRAC (installed on passive)
15.15.10.202/24
PDU 1
15.15.10.101/24
PDU 2
15.15.10.102/24
Note: All IPs should be on the same subnet.
iDRAC and APC PDU settings.
iDRAC (installed on active)
Login name: root password: calvin
iDRAC (installed on passive)
Login name: root password: calvin
PDU 1
Login name: apc password: apc
port 2 for active, port 3 for passive