Deployment Guide
24 Dell Hybrid Cloud System for Microsoft Cloud Platform System Standard
2. Verify that the SMA MPs are updated in the SCOM Operations Console
a. In the Management Pack list (Administration | Management Packs) verify the version of these
files has been updated to 7.2.102.0
b. The updated MPs should show with the names of “Microsoft System Center Service
Management Automation Library”, “Microsoft System Center Service Management
Automation Dashboards”, and “Microsoft System Center 2012 R2 Service Management
Automation”. The version should be 7.2.102.0 is they have been imported correctly.
Post-update clean up
After you have verified that patching has completed successfully, do the following to clean up the
environment.
1. If you disabled DPM agents on the DPM servers earlier, do the following to restart any canceled
jobs and enable the DPM agents:
• On the Console VM, make sure that you are logged on as the account that you created for
patching, such as CPS-Update-Admin.
• Open an elevated Windows PowerShell session, and then run the following command:
$cred = Get-Credential (whoami)
• When prompted, enter the account password.
• Run the following commands. Press Enter after each command.
cd “\\VM Name\PUShare\<CPSPU Folder
Name>\>\Framework\PatchingUpgrade"
Import-Module .\PatchingUpgrade\DPM.psm1
Set-DPMBackupMode -BackupMode Enable -Credential $cred
2. If disk space is a concern, you can delete the VMM trace logs on each VMM server.
These files are located at the root of C: on each VMM server, and will have names like:
C:\VMMLog_<Prefix>-VMM-01_03301505.etl.