User's Manual

82 Configuring the iDRAC Using the Web Interface
b
In the
Network Configuration
page under
IPMI LAN Settings
, select
Enable IPMI Over LAN
.
c
Update the IPMI LAN channel privileges, if required:
NOTE: This setting determines the IPMI commands that can be executed
from the IPMI over LAN interface. For more information, see the IPMI 2.0
specifications.
Under
IPMI LAN Settings
, click the
Channel Privilege Level Limit
drop-down menu, select
Administrator
,
Operator
, or
User
and click
Apply
.
d
Set the IPMI LAN channel encryption key, if required.
NOTE: The iDRAC IPMI supports the RMCP+ protocol.
NOTE: The encryption key must consist of an even number of hexadecimal
characters with a maximum length of 20 characters.
Under
IPMI LAN Settings
in the
Encryption Key field
, type the
encryption key.
e
Click
Apply
.
3
Configure IPMI Serial over LAN (SOL).
a
Click
System
Remote Access
iDRAC
.
b
Click the
Network Security
tab, then click
Serial Over LAN
.
c
On the
Serial Over LAN Configuration
page, click the
Enable Serial
Over LAN
checkbox to enable Serial over LAN.
d
Update the IPMI SOL baud rate.
NOTE: To redirect the serial console over the LAN, ensure that the SOL baud
rate is identical to your managed server’s baud rate.
Click the
Baud Rate
drop-down menu to select a data speed of
19.2 kbps, 57.6 kbps or 115.2 kbps.
e
Click
Apply
.