iDRAC 8/7 v2.60.60.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2018 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Introduction..................................................................................................................................................34 New in this release...........................................................................................................................................................34 Supported RACADM Interfaces.....................................................................................................................................
getsel................................................................................................................................................................................. 65 getsensorinfo....................................................................................................................................................................66 getssninfo.......................................................................................................................................
testalert............................................................................................................................................................................ 131 traceroute.........................................................................................................................................................................131 traceroute6....................................................................................................................................
cfgUserAdminUserName - Read or Write............................................................................................................. 152 cfgUserAdminPassword - Write Only.................................................................................................................... 152 cfgUserAdminEnable - Read or Write.................................................................................................................... 152 cfgUserAdminSolEnable (Read or Write)................
cfgRacTuneDaylightOffset (Read Only)................................................................................................................ 164 cfgRacTuneTimezoneOffset (Read Only)............................................................................................................. 165 cfgRacTuneLocalServerVideo (Read or Write).....................................................................................................165 cfgRacTuneLocalConfigDisable (Read or Write)..................
cfgLDAPBaseDN (Read or Write)...........................................................................................................................177 cfgLDAPUserAttribute (Read or Write)................................................................................................................. 177 cfgLDAPGroupAttribute (Read or Write)...............................................................................................................178 cfgLDAPGroupAttributeIsDN (Read or Write).........
cfgIpmiPetAlertEnable (Read or Write)................................................................................................................. 189 cfgUserDomain............................................................................................................................................................... 189 cfgUserDomainIndex (Read Only)..........................................................................................................................
cfgServerPowerSupplyOnlineStatus (Read Only)............................................................................................... 202 cfgServerPowerSupplyFwVer (Read Only)..........................................................................................................202 cfgServerPowerSupplyCurrentDraw (Read Only)...............................................................................................203 cfgServerPowerSupplyType.......................................................
cfgIpmiSerialFlowControl (Read or Write).............................................................................................................214 cfgIpmiSerialHandshakeControl (Read or Write)..................................................................................................214 cfgIpmiSerialNewLineSequence (Read or Write)................................................................................................. 215 cfgIpmiSerialLineEdit (Read or Write).............................
4 Database Objects With Get and Set Commands........................................................................................ 227 System.Backplane.......................................................................................................................................................... 231 System.Backplane.BackplaneBusMode (Read Only)...........................................................................................231 System.ChassisControl.......................................
System.Power.ServerAllocation (Read Only)....................................................................................................... 244 System.Power.Avg.LastDay (Read Only)..............................................................................................................244 System.Power.Avg.LastHour (Read Only)............................................................................................................245 System.Power.Avg.LastWeek (Read Only)...........................
System.Power.Supply.[i].MaxOutputPower (Read Only)................................................................................... 260 System.Power.Supply.[i].Status (Read Only)....................................................................................................... 260 System.Power.Supply.[i].Type (Read Only)............................................................................................................261 System.Power.Supply.[i].LineStatus (Read Only)..........................
iDRAC.ActiveDirectory.DCLookupByUserDomain (Read or Write)....................................................................275 iDRAC.ActiveDirectory.DCLookupDomainName (Read or Write)...................................................................... 275 iDRAC.ActiveDirectory.DCLookupEnable (Read or Write)..................................................................................276 iDRAC.ActiveDirectory.DomainController1 (Read or Write)..........................................................
iDRAC.IPBlocking.RangeAddr (Read or Write).................................................................................................... 290 iDRAC.IPBlocking.RangeEnable (Read or Write).................................................................................................290 iDRAC.IPBlocking.RangeMask (Read or Write)................................................................................................... 290 iDRAC.IPMILan.............................................................
iDRAC.IPv6.Address 3 (Read or Write).................................................................................................................304 iDRAC.IPv6.Address 4 (Read or Write).................................................................................................................305 iDRAC.IPv6.Address 5 (Read or Write).................................................................................................................305 iDRAC.IPv6.Address 6 (Read or Write).................
iDRAC.LocalSecurity...................................................................................................................................................... 319 iDRAC.LocalSecurity.LocalConfigDisabled (Read or Write)................................................................................ 319 iDRAC.LocalSecurity.PrebootConfig (Read or Write).......................................................................................... 319 iDRAC.Logging.........................................
iDRAC.Racadm.Timeout (Read or Write)..............................................................................................................334 iDRAC.Redfish................................................................................................................................................................335 iDRAC.Redfish.Enable (Read or Write)................................................................................................................. 335 iDRAC.Redfisheventing..........
iDRAC.ServiceModule.OMSAPresence (Read Only)...........................................................................................348 iDRAC.ServiceModule.OSInfo (Read or Write).................................................................................................... 348 iDRAC.ServiceModule.ServiceModuleEnable (Read or Write)...........................................................................349 iDRAC.ServiceModule.ServiceModuleState (Read or Write)......................................
iDRAC.Time.DayLightOffset (Read or Write)........................................................................................................ 361 iDRAC.Time.Timezone (Read or Write)................................................................................................................. 362 iDRAC.Time.TimeZoneOffset (Read or Write)...................................................................................................... 362 iDRAC.Tuning.................................................
iDRAC.VirtualConsole.................................................................................................................................................... 375 iDRAC.VirtualConsole.AccessPrivilege (Read or Write)...................................................................................... 375 iDRAC.VirtualConsole.AttachState (Read or Write)............................................................................................ 375 iDRAC.VirtualConsole.Enable (Read or Write)........
BIOS.EmbServerMgmt.FrontLcd (Read or Write).............................................................................................. 390 BIOS.EmbServerMgmt.UserLcdStr (Read or Write).......................................................................................... 390 BIOS.IntegratedDevices................................................................................................................................................390 BIOS.IntegratedDevices.EmbNic1 (Read or Write)..............
BIOS.MiscSettings.AssetTag (Read or Write)......................................................................................................406 BIOS.MiscSettings.ErrPrompt (Read or Write)................................................................................................... 406 BIOS.MiscSettings.InSystemCharacterization (Read or Write).........................................................................406 BIOS.MiscSettings.NumLock (Read or Write).........................................
BIOS.ProcSettings.Proc3L3Cache (Read or Write).............................................................................................421 BIOS.ProcSettings.Proc3NumCores (Read or Write)..........................................................................................421 BIOS.ProcSettings.Proc4Brand (Read or Write)................................................................................................. 422 BIOS.ProcSettings.Proc4ControlledTurbo (Read or Write)............................
BIOS.SataSettings.SataPortB (Read or Write).................................................................................................... 437 BIOS.SataSettings.SataPortBCapacity (Read or Write)..................................................................................... 437 BIOS.SataSettings.SataPortBDriveType (Read or Write)................................................................................... 437 BIOS.SataSettings.SataPortBModel (Read or Write)...................................
BIOS.SlotDisablement.Slot1 (Read or Write)........................................................................................................ 452 BIOS.SlotDisablement.Slot2 (Read or Write)....................................................................................................... 452 BIOS.SlotDisablement.Slot3 (Read or Write)....................................................................................................... 452 BIOS.SlotDisablement.Slot4 (Read or Write)...................
BIOS.SysSecurity.NmiButton (Read or Write)..................................................................................................... 468 BIOS.SysSecurity.PasswordStatus (Read or Write)............................................................................................469 BIOS.SysSecurity.PwrButton (Read or Write)..................................................................................................... 469 BIOS.SysSecurity.SecureBoot (Read or Write)..............................
FC.HBAConfig.PortDownRetryCount (Read or Write).......................................................................................483 FC.HBAConfig.PortDownTimeout (Read or Write).............................................................................................483 FC.HBAConfig.PortLoginRetryCount (Read or Write)........................................................................................484 FC.HBAConfig.PortLoginTimeout (Read or Write)................................................
NIC.FCOECapabilities.MaxIOsPerSession (Read Only)...................................................................................... 497 NIC.FCOECapabilities.MaxNPIVPerPort (Read Only).........................................................................................497 NIC.FCOECapabilities.MaxNumberExchanges (Read Only).............................................................................. 498 NIC.FCOECapabilities.MaxNumberLogins (Read Only)..................................................
NIC.IscsiGenParams.FirstHddTarget (Read or Write).......................................................................................... 512 NIC.IscsiGenParams.IpAutoConfig (Read or Write)............................................................................................. 512 NIC.IscsiGenParams.IpVer (Read or Write)...........................................................................................................512 NIC.IscsiGenParams.IscsiTgtBoot (Read or Write).........................
NIC.NICConfig.VLanMode (Read or Write).......................................................................................................... 527 NIC.NICConfig.WakeOnLan (Read or Write)........................................................................................................528 NIC.NICConfig.WakeOnLanLnkSpeed (Read or Write)...................................................................................... 528 NIC.NICPartitioningConfig.....................................................
NIC.VndrConfigGroup.VirtWWN (Read or Write)................................................................................................ 542 NIC.VndrConfigGroup.VirtWWPN (Read or Write)............................................................................................. 543 NIC.VndrConfigGroup.WWN (Read Only)............................................................................................................ 543 NIC.VndrConfigGroup.WWPN (Read Only)..........................................
1 Introduction This document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object definitions for the following: • iDRAC for Blade Servers • iDRAC on Rack and Tower Servers Most of the commands mentioned in this document are applicable for multi-generation servers. That is, the commands are applicable for iDRAC6, iDRAC7, and iDRAC8.
The RACADM utility supports the following interfaces: • Local — Supports running RACADM commands from the managed server’s operating system. To run local RACADM commands, install the OpenManage software on the managed server. Only one instance of Local RACADM can be executed on a system at a time. If you try to open another instance, an error message is displayed and the second instance of Local RACADM closes immediately. To download the local RACADM tool from www.dell.
• To display the supported indexes for a specified group, run: racadm get device. Example racadm get nic.nicconfig NIC.nicconfig.1 [Key=NIC.Integrated.1-1-1#nicconfig] NIC.nicconfig.2 [Key=NIC.Integrated.1-2-1#nicconfig] NIC.nicconfig.3 [Key=NIC.Integrated.1-3-1#nicconfig] NIC.nicconfig.4 [Key=NIC.Integrated.1-4-1#nicconfig] • To display the object list for the specified group, run: racadm get device.. Example racadm get nic.nicconfig.2 [Key=NIC.Integrated.
• Display all the available RACADM commands in the alphabetical order on pressing the Tab key at the prompt. • View the complete list, enter the starting letter of the command at the prompt and press Tab key. • Navigate the cursor within a command, press: Home key: Directs to the starting of the command. End key: Directs to the end of the command. • View the history of the commands that were run in the current session, press up and down arrow key.
Lifecycle Controller Log Lifecycle Controller logs provide the history of changes related to components installed on a managed system. You can also add work notes to each log entry. The following events and activities are logged: • System events • Storage devices • Network devices • Configuration • Audit • Updates You can view and filter logs based on the category and severity level. You can also export and add a work note to a log event.
Subcommand iDRAC on Blade Servers Telnet/SSH/Serial Local RACADM Remote RACADM getconfig Yes Yes Yes gethostnetworkinterfaces Yes Yes Yes getled Yes Yes Yes getniccfg Yes Yes Yes getraclog Yes Yes Yes getractime Yes Yes Yes getsel Yes Yes Yes getsensorinfo Yes Yes Yes getssninfo Yes Yes Yes getsvctag Yes Yes Yes getsysinfo Yes Yes Yes gettracelog Yes Yes Yes getversion Yes Yes Yes Help and help subcommand Yes Yes Yes hwinventory Yes Yes Yes ifc
Subcommand iDRAC on Blade Servers Telnet/SSH/Serial Local RACADM Remote RACADM sslcertupload No Yes Yes sslcertview Yes Yes Yes sslcertdelete Yes Yes Yes sslcsrgen Yes Yes Yes sslkeyupload No Yes Yes sslresetcfg Yes Yes Yes storage Yes Yes Yes swinventory Yes Yes Yes systemconfig Yes Yes Yes systemerase Yes Yes Yes systemperfstatistics Yes Yes Yes techsupreport Yes Yes Yes testemail Yes Yes Yes testtrap Yes Yes Yes testalert Yes Yes Yes tracero
The following system documents are also available to provide more information about the system in which iDRAC is installed: • The Hardware Owner’s Manual provides information about system features and describes how to troubleshoot the system and install or replace system components. • Documentation for any components you purchased separately provides information to configure and install the options.
2 RACADM Subcommand Details This section provides detailed description of the RACADM subcommands including the syntax and valid entries. Topics: • Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands • Help and help subcommand • arp • autoupdatescheduler • cd • cd..
• krbkeytabupload • lclog • license • netstat • nicstatistics • ping • ping6 • RACADM Proxy • racdump • racreset • racresetcfg • remoteimage • rollback • sensorsettings • serveraction • set • setled • setniccfg • sshpkauth • sslcertdownload • sslcertupload • sslcertview • sslcertdelete • sslcsrgen • sslkeyupload • sslresetcfg • storage • swinventory • systemconfig • systemerase • systemperfstatistics • techsupreport • testemail • testtrap •
Strings containing the following special characters must be quoted using double quotation marks: • $ (dollar sign) • " (double quotation mark) • ` (backward quotation mark) • \ (backward slash) • ~ (tilde) • | (vertical bar) • ( (left parentheses) • ) (right parentheses) • & (ampersand) • > (greater than) • < (less than) • # (pound) • ASCII code 32 (space) There are different escaping rules for double quotation marks.
arp Table 4. arp table Description Displays the contents of the Address Resolution Protocol (ARP) table. ARP table entries cannot be added or deleted. To use this subcommand, you must have Debug privilege. Synopsis racadm arp Input N/A Example racadm arp Table 5. Output Address HW Type HW Address Mask Device 192.168.1.1 Ether 00:0d:65:f3:7c:bf C eth0 autoupdatescheduler Table 6.
• • • NOTE: For CIFS, enter the domain name as domain or username. -p — Specifies the password of the remote share that stores the catalog file. -l — Specifies the network share (NFS, CIFS, FTP, TFTP, or HTTP) location of the catalog file. IPv4 and IPv6 addresses are supported. -f — Specifies the catalog location and the filename. If the filename is not specified, then the default file used is catalog.xml.
– For TFTP, run the command: racadm autoupdatescheduler create -l tftp://1.2.3.4 -f cat.xml.gz -time 14:30 -dom 1 -rp 5 -a 1 – To view AutoUpdateScheduler parameter: racadm autoupdatescheduler view hostname = 192.168.0 sharename = nfs sharetype = nfs catalogname = Catlog.
• Example 2: To traverse back from system object to the prompt: – Input: racadm/system> cd.. – Output: racadm>> clearasrscreen Table 9. Details of clearasrscreen Description Clears the last crash (ASR) screen that is in memory. For more information, see "Enabling Last Crash Screen" section in the iDRAC User’s Guide. NOTE: To run this subcommand, you must have the Clear Logs permission. Synopsis racadm clearasrscreen Input None Output Clears the last crash screen buffer.
To run this subcommand, you must have the Administrator permission. NOTE: This subcommand ends all the sessions other than the current session. Synopsis Input • racadm closessn –i • racadm closessn -a • racadm closessn -u • • —i — The session ID of the session to close, which can be retrieved using RACADM getssninfo subcommand. Session running this command cannot be closed. —a — Closes all sessions.
NOTE: This subcommand will be deprecated in the later versions. For information about configurations, see the set subcommand. Synopsis • racadm config -g -o
coredump Table 14. Details of coredump Description Displays detailed information related to any recent critical issues that have occurred with iDRAC. The coredump information can be used to diagnose these critical issues. If available, the coredump information is persistent across iDRAC power cycles and remains available until either of the following conditions occur: The coredump information is deleted using the coredumpdelete subcommand.
The results of the latest successfully run remote diagnostics are available and retrievable remotely through an NFS or a CIFS share. Synopsis To run a remote diagnostic report: racadm diagnostics run -m -r -s -e To export a remote diagnostic report: racadm diagnostics export -f -l -u -p Input • —m — Specifies the type of diagnostic mode.
To use this subcommand with the set and test option, you must have the Administrator privilege. Synopsis racadm eventfilters racadm eventfilters get -c racadm eventfilters set -c -a -n racadm eventfilters set -c -a -r racadm eventfilters test -i NOTE: The general format of an alert category: idrac.alert.category.[subcategory].
Example • Display all available event filter configurations: racadm eventfilters get -c idrac.alert.all • Display eventfilter configurations for a specific category. For example, audit: racadm eventfilters get -c idrac.alert.audit • Display eventfilter configurations for a specific subcategory. For example, licensing under the audit category: racadm eventfilters get -c idrac.alert.audit.lic • Display eventfilter configurations for a specific severity.
Input Example • show — to view the errors currently being displayed on the LCD screen. • hide — to hide the errors currently being displayed on the LCD screen. • racadm frontpanelerror show Front Panel Error—Show Enabled. • racadm frontpanelerror hide Front Panel Error—Hide Enabled. fwupdate Table 20. Details of fwupdate Description Allows you to update the firmware on the server iDRACs device. You can: • • • • Check the firmware update process status.
• — Specifies the FTP server IP address or FQDN, username, and password used for firmware image. Applies FTP download process for firmware update. Output Displays a message indicating the operation that is being performed. Example • Uploads a firmware image from the client and start firmware update: racadm fwupdate -p -u -d /tmp/images • Upload firmware image from FTP server and start firmware update: racadm fwupdate -f 192.168.0.10 test test -d firmimg.
• • INI format — The INI format files can be exported to a local file only NOTE: INI file format is deprecated. It is recommended to use XML or JSON formats. Server Configuration Profile XML/JSON format — XML/JSON format files can be exported to a local file, to an NFS network share or to a CIFS network share. NOTE: To run theGet sub-command for Server Configuration Profile XML files, use the Lifecycle Controller version 1.1 or later.
The valid values are: – JSON—It exports the SCP JSON file to a network share file. – xml—It exports the SCP xml format file, either to a local or network share file. – ini—It exports the legacy configuration file. If -t is not specified, then the ini format file is exported. It can only be exported to a local file. • • • • NOTE: To import or export Server Configuration Profile xml/JSON files, Lifecycle Controller version 1.1 or later is required. --clone—Gets the configuration .
NOTE: This subcommand is deprecated. For viewing the configuration objects and its values, use get subcommand. For more information, see the Integrated Dell Remote Access Controller (iDRAC8) and iDRAC7 RACADM Command Line Interface Reference Guide available at www.dell.com/support/manuals.
• iDRAC to myrac.cfg. racadm getconfig -f myrac.cfg If you do not configure the following key attributes in their respective groups for a particular index, the groups are not saved in to the file. This is applicable for all the index groups. Saves all group configuration objects from iDRAC to myrac.cfg. racadm getconfig -f myrac.cfg Saves all group configuration objects from iDRAC to myrac.cfg. racadm getconfig -f myrac.cfg Table 24. Details gethostnetworkinterfaces Table 25.
NOTE: To run this subcommand, you must have iDRAC service module installed on the server operating system. Synopsis racadm gethostnetworkinterfaces racadm gethostnetworkinterfaces Examples • To display the details of all the network interfaces on the server.
racadm getled LED State : Not-Blinking getniccfg Table 27. Details of getniccfg attribute Description Displays the current and static NIC settings for iDRAC.
Output NOTE: Table 28. Output IPv4 settings: NIC Enabled =1 IPv4 Enabled =1 DHCP Enabled =1 IP Address =10.94.225.165 Subnet Mask =255.255.255.128 Gateway =10.94.225.
NOTE: IPv6 Address 1 field indicates static IP and IPv6 Address 2 field indicates dynamic IP. NOTE: LOM Status is displayed only for iDRAC on Rack and Tower servers and is not displayed for iDRAC Enterprise on Blade servers. Example • Display iDRAC network settings in server slot 1 racadm getniccfg -m server-1 getraclog Table 29. Details of getraclog attribute Description Synopsis The getraclog command displays RAC log entries.
Message ID = USR0032 Category = Audit AgentID = RACLOG Severity = Information Timestamp = 2014-06-11 19:54:00 Message = The session for root from 192.168.0 using RACADM is logged off. Message Arg 1 = root Message Arg 2 = 10.94.98.92 Message Arg 3 = RACADM FQDD = iDRAC.Embedded.1 ------------------------------------------------------------------------------------ getractime Table 30. Details of getractime attribute Description Displays the current iDRAC time.
• Display number of records in log. racadm getsel -i getsensorinfo Table 32. Details of getsensorinfo Description Displays the status for system sensors. NOTE: For Dell PowerEdge FX2 chassis with FM120x4 server, the power related information is not displayed. NOTE: General purpose graphical processing unit (GPGPU) status is displayed only on PowerEdge C4130 servers. Synopsis Input • racadm getsensorinfo • racadm getsensorinfo -c -c — Compact output format.
Table 36. Temperature sensor System Board Fan1 RPM Ok 5880 RPM 600 RPM NA 21% System Board Fan2 RPM Ok 6000 RPM 600 RPM NA 0% System Board Fan3 RPM Ok 5880 RPM 600 RPM NA 0% System Board Fan4 RPM Ok 5880 RPM 600 RPM NA 0% System Board Fan5 RPM Ok 5640 RPM 600 RPM NA 144% System Board Fan6 RPM Ok 5880 RPM 600 RPM NA 152% Table 37.
System Board PS1 PG Fail Ok Good NA NA System Board 1.5V AUX PG Ok Good NA NA CPU1 M01 VTT PG Ok Good NA NA PS1 Voltage 1 Ok 240 V NA NA System Board DIMM PG Ok Good NA NA Table 38. Current sensor [R/W] [R/W] PS1 Current 1 Ok 0.4 Amps NA NA 0 Amps [N] 0 Amps [N] System Board Pwr Consumption Ok 56 Watts NA 1386 Watts 0 Watts [N] 1260 Watts [N] Table 39.
DIMM B3 N/A Absent NA NA DIMM B4 N/A Absent NA NA DIMM B5 N/A Absent NA NA DIMM B6 N/A Absent NA NA DIMM B7 N/A Absent NA NA DIMM B8 N/A Absent NA NA DIMM B9 N/A Absent NA NA DIMM B10 N/A Absent NA NA DIMM B11 N/A Absent NA NA DIMM B12 N/A Absent NA NA Table 41.
Table 44. INTRUSION sensor System Board Intrusion Closed Power ON System Board Fan Redundancy Full Redundant Fan System Board PS Redundancy Disabled PSU Table 45. REDUNDANCY sensor Table 46.
Table 48. Example SSNID Type User IP Address Login Date/Time 58999 SSH root 192.168.0.10 04/07/2016 12:00:34 Display the details of sessions without header racadm getssninfo -A "43584" "SSH" "root" "192.168.0.10" "04/07/2016 12:00:34" getsvctag Table 49. Details of attribute Description Displays the service tag of the host system.
Output RAC Information: RAC Date/Time = Thu Sep Firmware Version Firmware Build Last Firmware Update Hardware Version MAC Address = = = = = 2.20.20.20 41 09/02/2015 22:18:35 0.01 B8:2A:72:FC:4F:B0 Common settings: Register DNS RAC Name DNS RAC Name Current DNS Domain Domain Name from DHCP = = = = 1 ipmierrata sha512.
• Display iDRAC information racadm getsysinfo -d • Display IPv4 details without header racadm getsysinfo -A "RAC IPv4 Information:" "1" "10.94.195.33" "10.94.195.1" "255.255.255.0" "1" "10.94.192.67" "0.0.0.0" "1" gettracelog Table 51. Details of attribute Description Synopsis Input Lists all the trace login entries of iDRAC. • racadm gettracelog [-i] • racadm gettracelog [-s ] [-c ] [--more] • —i — Displays the number of entries in iDRAC trace log.
• -i — Displays the server's current IDSDM version. • -f — Filters the components and must be one of the following values: – bios: BIOS – idrac: iDRAC – lc: Lifecycle Controller – idsdm: SD card Table 53. Details server-1 1.40.40 (Build 08) PowerEdge M520 iDRAC Y server-2 3.50 (Build 2) PowerEdgeM610x iDRAC6 Y server-4 3.50 (Build 4) PowerEdgeM710HD iDRAC6 Table 54.
server-9 1.7.1 PowerEdgeM520 Table 56. Details switch-1 MXL 10/40GbE X01 9-2(0-296) switch-2 M8024-k 10GbE SW A00 switch-3 Dell PowerConnect M8024 X00 switch-4 Dell PowerConnect M8024 X00 switch-5 Dell PowerConnect M6348 X02 switch-6 Dell PowerConnect M6220 A01 5.0.1.3 hwinventory Table 57. Details of hwinventory Description Allows you to display or export current internal hardware inventory or shipped hardware inventory by device.
NIC.Slot.
Receive Flow Control: Media Type: NIC Mode: FCoE Offload Mode: iSCSI Offload Mode: Max Number of IOs per session supported: Number of Max LOGINs per port: Max Number of exchanges: Max NPIV WWN per port: Number of Targets Supported: Max Number of outstanding commands supported across all sessions: Flex Addressing: UEFI: iSCSI Offload: iSCSI Boot: TCP OffloadEngine: FCoE: FCoE Boot: PXE Boot: SRIOV: Wake on LAN: Network Management Pass Through: OS2BMC PassThrough: Energy Efficient Ethernet: On Chip Thermal Se
Vendor Name: Device Name: 21000024FF089D8A WWN: VirtWWN: WWPN: VirtWWPN: Chip Type: Family Version: EFI Version: OS Driver Version: First FC Target WWPN: First FC Target LUN: Second FC Target WWPN: Second FC Target LUN: Hard Zone Address: Hard Zone Enable: FC Tape Enable: Loop reset Delay: Frame Payload Size : Fabric Login Retry Count: Fabric Login Timeout: Port Login Retry Count: Port Login Timeout: Port Down Retry Count: Port Down Timeout: Link Down Timeout: Port Number: Port Speed: No capabilities found
Max Number of IOs per connection supported: Maximum number of Logins per port: Maximum number of exchanges: Maximum NPIV per port: Maximum number of FC Targets supported: Maximum number of outstanding commands across Flex Addressing: UEFI: FC Start: On Chip Thermal Sensor: Feature Licensing: 9 8 9 1 8 all connections: 9 Capable Capable Capable Capable Not Capable ifconfig Table 58. Details of ifconfig attribute Description Displays the contents of the network interface table.
• NOTE: Export to an IPv6 NFS share is not supported. -t — Specifies the exported file type. Valid values are xml and csv. These values are case-insensitive. NOTE: From firmware RACADM, only export to a remote share is supported. The behavior of remote share is not defined when the path specified (-l) contains special characters. Example • Export the log to a remote CIFS share. racadm inlettemphistory export -f Mylog.xml -u admin -p xxx -l //1.2.3.
Input • -i—Specifies a job ID that is displayed or deleted. • --all—The job IDs that are not applicable are deleted. • -fqdd—Specifies an FQDD for which a job should be created. • —r —Specifies a reboot type. NOTE: The value JID_CLEARALL forces delete all the possible jobs in the queue. – none—No Reboot Job. This option is the default value. – pwrcycle—Power cycle. – graceful—Graceful Reboot without forced shutdown. – forced —Graceful Reboot with forced shutdown.
To run this subcommand, you must have the Server Control privilege. Synopsis racadm krbkeytabupload [-f ] is the name of the file including the path. Input -f — Specifies the filename of the keytab uploaded. If the file is not specified, the keytab file in the current directory is selected. Output When successful Kerberos Keytab successfully uploaded to the RAC message is displayed. If unsuccessful, appropriate error message is displayed. Example racadm krbkeytabupload -f c:\keyt
– SEL – RACLOG – DE – WSMAN – RACADM – iDRAC_GUI • -k—Filters the records based on the filter string provided in racadm lclog view command. • -c—The category used to filter the records. Provides multiple categories using a "," as the delimiter. The value is case-insensitive. Valid category values: – System – Storage – Worknotes – Config – Updates – Audit • -b —The subcategory used to filter the records. Provides multiple subcategories using a "," as the delimiter.
Example • -j—Specifies the Job ID. • Display the number of records present in the Lifecycle log. racadm lclog view -i • Display the records containing the string session racadm lclog view -k session • Display the iDRAC agent idrac records, under the storage category and storage physical disk drive subcategory, with severity set to warning.
Input • racadm license import [-f ] -l -u -p -c [-o] • racadm license export -f [-l ] [-u ] [-p ] -e -c • racadm license delete -t [-o] • racadm license delete -e [-o] • racadm license delete -c [-o] • racadm license replace -u -p -f -l -t [-o] • view — Vi
• Import a license by overriding the EULA warning. racadm license import -u admin -p passwd -f License.xml -l //192.168.0/licshare -c idrac.embedded.1 -o • Import a license from the local file system using Local RACADM. racadm license import -f License.xml -c idrac.embedded.1 • Import a license from the local file system using Remote RACADM. racadm -r 192.168.0.1 -u admin -p xxx license import -f C:\Mylicdir\License.xml -c idrac.embedded.1 • Export a license file. racadm license export -f license.
nicstatistics Table 66. Details of nicstatistics Description Displays the statistics for the NIC FQDD. Synopsis • racadm nicstatistics • racadm nicstatistics • racadm hwinventory NIC.Integrated.
ping Table 67. Details of ping attribute Description Verifies if the destination IP address is reachable from iDRAC with the current routing-table contents. A destination IP address is required. Based on the current routing-table contents, an ICMP echo packet is sent to the destination IP address. To run this subcommand, you must have the Debug privilege. Synopsis racadm ping Input — The IP address of the remote endpoint to ping. Output PING 192.168.0 (192.168.
The CMC configuration commands are supported through local proxy when local configuration is enabled on iDRAC. NOTE: Local racadm and local racadm proxy runs with root user privilege.
NOTE: • • • The attribute racadm getconfig -g cfgractuning -o cfgRacTuneChassisMgmtAtServer must be set as non-zero in CMC. The attribute racadm get system.ChassisControl.ChassisManagementMonitorin attribute must be enabled in iDRAC. --proxy must be entered at the end of the command. • Table 70. The root privilege is the default privilege for Local RACADM proxy.
Remote RACADM racadm getractime -u root -p xxx -r 192.168.0 getractime --proxy racdump Table 71. Details of racdump attribute Description Provides a single command to get dump, status, and general iDRAC board information. To run this subcommand, you must have the Debug permission.
Current IP Address 2 Current IP Address 3 Current IP Address 4 Current IP Address 5 Current IP Address 6 Current IP Address 7 Current IP Address 8 Current IP Address 9 Current IP Address 10 Current IP Address 11 Current IP Address 12 Current IP Address 13 Current IP Address 14 Current IP Address 15 DNS Servers from DHCPv6 Current DNS Server 1 Current DNS Server 2 = = = = = = = = = = = = = = = = = :: :: :: :: :: :: :: :: :: :: :: :: :: :: Disabled :: :: System Information: System Model System Revision Sys
Active Internet connections (w/o servers) Proto Recv-Q Send-Q Local Address tcp 0 0 192.168.0.1:53986 tcp 0 0 192.168.0.1:53985 tcp 0 0 192.168.0.1:199 tcp 0 0 192.168.0.1:199 Foreign Address 192.168.0.1:199 192.168.0.1:199 192.168.0.1:53986 192.168.0.
Input • Output racadm racreset RAC reset operation initiated successfully. It may take up to a minute for the RAC to come online again. Example • -f — This option is used to force the reset. iDRAC reset racadm racreset racresetcfg Table 73. Details of racresetcfg attribute Description Deletes your current iDRAC configuration and resets iDRAC to the factory default settings. After reset, the default name and password are root and calvin, respectively, and the IP address is 192.168.0.120.
To run this subcommand, you must log in with virtual media privilege for iDRAC. Synopsis Input • racadm remoteimage -d • racadm remoteimage -s • racadm remoteimage –c –u -p -l • -c—Connect the image. • -d—Disconnect image. • -p—Password to access shared folder. • -u—username to access shared folder. • -l—Image location on the network share; use single quotation marks around the location. • -s—Display status.
rollback Table 75. Details of rollback Description Allows you to roll back the firmware to an earlier version. Synopsis racadm rollback [--reboot] NOTE: To get the list of available rollback versions and FQDDs, run the racadm swinventory command. Input Example • : Specify the FQDD of the device for which the rollback is required. • --reboot: Performs a graceful system reboot after the BIOS firmware rollback. • To perform BIOS firmware rollback: racadm rollback iDRAC.Embedded.
serveraction Table 77. Details of serveraction attribute Description Enables you to perform power management operations on the blade system. To run this subcommand, you must have the Execute Server Control Commands permission. Synopsis racadm serveraction -f Input — Specifies the power management operation to perform. The options are: • hardreset — Performs a force reset (reboot) operation on the managed system.
NOTE: To run theSet sub-command for Server Configuration Profile XML files, use the Lifecycle Controller version 1.1 or later. Depending on the type of configuration object being modified, the new values could be applied immediately (in “real-time”) or require staging and a reboot of the system to apply the new values.
• • -f — Enables set to configure the device from a specified file. This option is not supported in the Firmware RACADM interface. --continue — This option is used with –f only and is applicable for only for INI file operation.. If a multi-object Set is unsuccessful for a , then Set continues with the next in the file. If this option is not used, then Set stops when it is unsuccessful for a particular .
Example Single-object Set of real-time objects • Configure LCD String. $ racadm set system.lcd.LCDUserString test • – Configure iDRAC name. racadm set iDRAC.Info.Name idrac-server100 Single-object Set of staged objects • Configure several BIOS settings, create a job to initiate application of new values, reboot the system, then wait for the job to complete. racadm racadm racadm racadm set BIOS.SysProfileSettings.ProcTurboMode Disabled set BIOS.ProcSettings.ProcVirtualization Enabled set BIOS.
setled Table 79. Details of setled attribute Description Sets the state (blinking or not blinking) of the LED on the specified module. To run this subcommand, you must have the Configure iDRAC permission. Synopsis Input racadm setled -l • -l — Specifies the LED state. The values are: – 0 — No Blinking – 1 — Blinking Example NOTE: The setled command generates an error when run on the extension slot of a multi-slot server. • From iDRAC stop LED from blinking.
• Configure DHCP mode for iDRAC IPv4 racadm setniccfg -d DHCP is now ENABLED • Configure DHCP mode for iDRAC IPv6 racadm setniccfg -d6 DHCP6 is now ENABLED sshpkauth Table 81. Details of sshpkauth attribute Description Enables you to upload and manage up to 4 different SSH public keys for each user. You can upload a key file or key text, view keys, or delete keys. This command has three mutually exclusive modes determined by the options — upload, view, and delete.
wilU2VLw/iRH1ZymUFnut8ggbPQgqV2L8bsUaMqb5PooIIvV6hy4isCNJU= 1024-bit RSA, converted from OpenSSH by xx_xx@xx.xx Key ID 2: Key ID 3: Key ID 4: sslcertdownload Table 82. Details of sslcertdownload attribute Description Downloads an SSL certificate from iDRAC to the client’s file system. To run this subcommand, you must have the Server Control privilege. NOTE: This subcommand is only supported on the remote interface(s).
• -k — Filename of the private key file while using type 6. The private key is generated when the CSR is generated. If the CSR is generated on another server, then it is necessary to upload the private key with the certificate. racadm -r 192.168.0.2 -u root -p xxx sslcertupload -t 2 -f cert.txt Output Certificate successfully uploaded to the RAC. Example • Uploading a server certificate. racadm -r 192.168.0.2 -u root -p xxx sslcertupload -t 1 -f cert.
Locality (L) Round Rock Organization (O) Dell Inc. Organizational Unit (OU) Remote Access Group Common Name (CN) iDRAC Default certificate Valid From Jul 7 23:54:19 2011 GMT Valid To Jun 4 23:54:19 2021 GMT racadm sslcertview -t 1 -A 00 US Texas Round Rock Dell Inc. Remote Access Group iDRAC default certificate US Texas Round Rock Dell Inc. Remote Access Group iDRAC default certificate Jun 7 23:54:19 2011 GMT Jun 4 23:54:19 2021 GMT sslcertdelete Table 86.
sslcsrgen Table 87. Details of sslcsrgen attribute Description Generates and downloads a certificate signing request (CSR) file to the client’s local file system. The CSR can be used for creating a custom SSL certificate that can be used for SSL transactions on iDRAC. To run this subcommand, you must have the Configure iDRAC privilege. Synopsis Input • racadm sslcsrgen -g • racadm sslcsrgen [-g] [-f ] • racadm sslcsrgen -s • -g — Generates a new CSR.
Input • -t — Specifies the key to upload. The value is: – 1 — SSL key used to generate the server certificate. • -f — Specifies the filename of the SSL key that must be uploaded. Output If upload is successful, the message SSL key successfully uploaded to the RAC is displayed. if upload is unsuccessful, error message is displayed. Example racadm sslkeyupload -t 1 -f c:\sslkey.txt sslresetcfg Table 89.
• To get the properties of PCIeSSD controller, run the following command: racadm storage get controllers: • To generate and view information about the inventory of batteries, run the following command: racadm storage get batteries -o racadm storage get batteries --refkey racadm storage get batteries --refkey -o racadm storage get batteries --refkey -o p
• To get the list of physical disks, run the following command: racadm storage get pdisks • To get the properties of PCIeSSD physical disk, run the following command: racadm storage get pdisks: • To generate and view information about the inventory of fans, run the following command: racadm storage get fans --refkey racadm storage get fans --refkey -o racadm storage get fans --refkey
wbf}] [-rp {nra|ra|ara}] [-ss {1k|2k|4k|8k| 16k|32k|64k|128k|256k|512k|1M|2M|4M|8M| 16M}]-pdkey: [-dcp {enabled|disabled|default}] [-name ] [-size {b|k|m|g|t}] [T10PIEnable] NOTE: T10PI is not supported on PERC 9 and PERC 10.
NOTE: replacephysicaldisk method is not supported on non-redundant RAID volumes. racadm raid setbootvd: -vd racadm raid forceonline: racadm raid forceoffline: racadm storage unlock: key -passwd • NOTE: If the –assign option is no, you cannot add other options. If the –assign option is yes and if the -type option is not present, the global hotspare (ghs) is created by default.
– r50—storage 50-Spanned Striping with Parity – r60—storage 60-Spanned Striping with Extra Parity • • • • • -wp{wt|wb|wbf}—Sets the write policy to Write Through, Write Back, or Write Back Force -rp {nra|ra|ara}—Sets the read policy to No Read Ahead, Read Ahead, Adaptive Read Ahead -ss—Specifies the stripe size to use. -pdkey:—Specifies the physical disk drive to use in the virtual disk. -dcp—Sets the Disk Cache Policy in the Virtual Disk. – enabled—Allows the virtual disk to use the cache.
• -dstpd-replaces a physical disk in virtual disk configuration. • -vd-virtual disk fqdd to make it as a bootable drive. • -speed—Specifies the initialization of the Virtual disk. – fast—Performs fast initialization. – full—Performs slow initialization. • • blink: or unblink: — can be physical disk drives, virtual disks, or PCIeSSD. —Specifies the PCIeSSD FQDD. • —Specifies the PCIeSSD controller or enclosure FQDD.
racadm racadm racadm racadm racadm racadm racadm racadm racadm racadm racadm racadm racadm racadm • storage storage storage storage storage storage storage storage storage storage storage storage storage storage get get get get get get get get get get get get get get controllers -o controllers -o -current controllers -o -pending enclosures -o controllers -o -p name,status vdisks -o -p layout,status controllers:RAID.INTEGRATED.0 emms:EMM.Slot.0:ENCLOSURE.EXTERNAL.0-0:RAID.INTEGRATED.0 controllers:RAID.
SupportEnhancedAutoForeignImport EnhancedAutoImportForeignConfig SupportControllerBootMode ControllerBootMode RealtimeConfigurationCapability CurrentControllerMode BootVD = = = = = = = Supported Enabled Supported Continue Boot On Error Capable RAID Disk.Virtual.0:RAID.Integrated.1-1 The following command displays the filtered property values for all returned controller objects: racadm storage get controllers -o -p Name RAID.Integrated.
PatrolReadRate PatrolReadMode PatrolReadState CheckConsistencyMode LoadBalanceSetting CopybackMode PreservedCache CacheMemorySize PersistHotspare SpindownUnconfiguredDrives SpindownHotspare Timeintervalforspindown SecurityStatus EncryptionMode SasAddress PciDeviceId PciSubdeviceId PciVendorId PciSubvendorId PciBus PciDevice PciFunction BusWidth SlotLength SlotType MaxCapableSpeed LearnMode T10PICapability SupportRAID10UnevenSpans SupportEnhancedAutoForeignImport EnhancedAutoImportForeignConfig SupportContro
PciSubdeviceId PciVendorId PciSubvendorId PciBus PciDevice PciFunction BusWidth SlotLength SlotType MaxCapableSpeed LearnMode T10PICapability SupportRAID10UnevenSpans SupportEnhancedAutoForeignImport EnhancedAutoImportForeignConfig SupportControllerBootMode RealtimeConfigurationCapability CurrentControllerMode BootVD = = = = = = = = = = = = = = = = = = = 0x61b 0x8086 0x1028 0x0 0x0 0x0 Unknown Unknown Unknown 6.
RollupStatus Ok State Online OperationalState Not applicable Layout Raid-0 Size 278.88 GB SpanDepth 1 AvailableProtocols SAS MediaType HDD ReadPolicy Read Ahead WritePolicy Write Back StripeSize 64K DiskCachePolicy Default BadBlocksFound NO Secured NO RemainingRedundancy 0 EnhancedCache Not Applicable T10PIStatus Disabled BlockSizeInBytes 512 – Table 92.
– To generate and view information about the inventory of physical disk drives connected to the enclosure or backplanes, run the following command: racadm storage get pdisks Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1 The following command is an optimized version and displays the full controller physical disks along with their keys: racadm storage get pdisks -o racadm storage get pdisks Disk.Bay.23:Enclosure.Internal.0-1:RAID.Integrated.
BusProtocol MediaType UsedraidDiskSpace AvailableraidDiskSpace Hotspare Manufacturer ProductId Revision SerialNumber PartNumber NegotiatedSpeed ManufacturedDay ManufacturedWeek ManufacturedYear SasAddress FormFactor raidNominalMediumRotationRate T10PICapability BlockSizeInBytes MaxCapableSpeed ForeignKeyIdentifier = = = = = = = = = = = = = = = = = = = = = SAS HDD 278.88 GB 0.00 GB NO SEAGATE ST9300605SS CS05 6XP40SA9 CN0745GC7262228706R7A00 6.0 Gb/s 4 32 2012 0x5000C5005952386D 2.
– The following command provides the list of enclosures: racadm storage get enclosures Enclosure.Internal.0-1:RAID.Integrated.1-1\ Enclosure.Internal.0-1:PCIeExtender.Slot.3 – The following command provides the properties of the specified PCIeSSD enclosure: racadm storage get enclosures:Enclosure.Internal.0-1:PCIeExtender.Slot.3 Enclosure.Internal.0-1:PCIeExtender.Slot.3 RollupStatus = Ok DeviceDescription = Enclosure.Internal.0-1:PCIeExtender.Slot.3 Name = PCIe SSD BP 1 SlotCount = 4 FirmwareVersion = 0.
Configuration • To view the help details for a configuration command, run the following command: admin1-> racadm storage help createvd Storage configuration of hardware RAID connected to the system.
– The following command encrypts the specified virtual disk: racadm storage encryptvd:Disk.Virtual.0:RAID.Integrated.1-1 NOTE: Virtual disk must be created with SED. – The following command assigns security key for controller: racadm storage createsecuritykey:RAID.Integrated.1-1 -key -xxx – The following command modifies security key for controller: racadm storage modifysecuritykey:RAID.Integrated.
• To cancel background initialization of a virtual disk racadm raid cancelbgi:Disk.Virtual.0:RAID.Integrated.1-1 • To replace physical disk in a virtual disk configuration racadm raid replacephysicaldisk:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 dstpd Disk.Bay.1:Enclosure.Internal.0-0:RAID.Integrated.1-1 • To set virtual disk as a boot drive racadm raid setbootvd:RAID.Integrated.1-1 -vd Disk.Virtual.0:RAID.Integrated.1-1 • To set virtual disk as a boot drive racadm raid setbootvd:RAID.
systemconfig Table 94. Details of systemconfig Description Enables you to perform the following: • Backup and restore for iDRAC and entire system configuration. • Automatic scheduling of backup operation. • View the auto backup feature settings. • Clear the auto backup feature settings. NOTE: • • • • • • Synopsis To run this subcommand, you require the Server Profile Export and Import license. Backup operation is licensed (Enterprise) but restore operation is not licensed.
• • -wom: Specifies the week of month to schedule an autobackup. Valid values are 1–4, L(Last week) or '*' (default — any week). -dow: Specifies the day of week to schedule an autobackup. Valid values are sun, mon, tue, wed, thu, fri, sat, or '*' (default — any day). NOTE: The -dom, -wom, or -dow option must be included in the command for the autoupdate schedule. The * value for the options must be included within ' ' (single quotation mark).
• AutoBackup system to vFlash SD. racadm systemconfig backup --vFlash -time 10:30 -wom 1 -dow mon -rp 6 -mb 1 systemerase Table 95. Details of systemerase Description Allows you to erase the components to remove the server from use. Synopsis • To erase a specific component. racadm systemerase • To erase multiple components.
[key = iDRAC.Embedded.1#SystemBoardIOUsageStat] [key = iDRAC.Embedded.1#SystemBoardMEMUsageStat] [key = iDRAC.Embedded.1#SystemBoardSYSUsageStat] • To list the usage statistics of a specific sensor racadm systemperfstatistics iDRAC.Embedded.
• To export the collected report data to local share. racadm techsupreport export -f Input • -t — type of logs. You can specify any of the following values separated by a ‘,’ (comma) – SysInfo — System Information – OSAppNoPII — Filtered OS and Application data – OSAppAll — OS and Application data – TTYLog — TTYLog data NOTE: – For updating the operating system application data collection, enter the value OSAppNoPII or OSAppAll to the -t option.
Success: Test e-mail sent successfully Output Failure: Unable to send test e-mail Commands for the idrac.EmailAlert group: Example • Enable the alert. racadm set idrac.EmailAlert.1.Enable 1 • Set the destination email address. racadm set idrac.EmailAlert.1.Address user1@mycompany.com • Set the custom message that is sent to the destination email address. racadm set idrac.emailalert.1.CustomMsg "This is a test!" • Make sure that the SMTP IP address is configured properly. racadm set idrac.
testalert Table 100. Details of testalert Description Tests FQDN supported SNMP trap notifications. To run this subcommand, you must have the Test Alert User Access. Synopsis racadm testalert -i Input -i — Specifies the index of the trap test. index must be an integer from 1 to 8 on iDRAC. Output Success: Test trap sent successfully Failure: Unable to send test trap Example • Test a trap with index as 1. racadm testalert -i 1 Test trap sent successfully.
update Table 103. Details of update Description Allows you to update the firmware of devices on the server. The supported firmware image file types are: • • • .exe — Windows-based Dell Update Package (DUP) .d7 .pm The supported catalog files are: • • .xml xml.gzip NOTE: Updating the platforms from the repository is not supported for IPv6. NOTE: Depending on the network traffic, the HTTP packet transfer may fail if you perform update operation from a remote RACADM through a local share.
• -po—Specifies the port for proxy server. • -pt—Specifies the proxy type. Valid values are HTTP and HTTPS. These values are case-insensitive. NOTE: – If the repository must be through a proxy, then the proxy server address, proxy username and the proxy password must be specified. – The Lifecycle Controller must be enabled for repository update. Output Firmware update job for is initiated.
• Generate a comparison report using about the available updates in the repository. racadm update -f Catalog.xml -l 192.168.11.10:/Repo -t NFS -a FALSE -verifycatalog • Perform update from an FTP repository and reboot the server to apply the updates. racadm update -f Catalog.xml -e 192.168.11.10/Repo/MyCatalog -a TRUE -t FTP • Perform update from an FTP repository with authentication and reboot the server to apply the updates. racadm update -f Catalog.xml -e 192.168.11.
usercertview Table 105. Details of usercertview Description Displays the user certificate or user CA certificate that exists on iDRAC. Synopsis racadm usercertview -t [-A] -i Input • -t — Specifies the type of certificate to view, either the user certificate or the user CA certificate. • – 1=user certificate – 2=user CA certificate -A — Prevents printing headers or labels. • -i — Index number of the user. Valid values are 2–16. Example To view user certificate for user 6.
If initialization is in progress, the message Initialization of the vFlash SD Card is now in progress is displayed. If unsuccessful, appropriate error message is displayed. Output If the status of the last operation performed is successful, the message LastAction Progress Status=============Initialize SD Card 100 % Complete is displayed. If unsuccessful, appropriate error message is displayed. vflashpartition Table 107. Details of vflashpartition Description Manages the partitions on the vFlash SD card.
• Create a partition from a remote image. racadm vflashpartition create -i 1 -o Drive1 -e cddvd -t image -l //ipaddress/sharefolder/isoimge.iso -u username -p xxx A new partition is created. By default, the created partition is read-only. This command is case-sensitive for the image filename extension. If the filename extension is in uppercase, for example FOO.ISO instead of FOO.iso, then the command returns a syntax error. • NOTE: – This feature is not supported in Local RACADM.
3 iDRAC Property Database Group and Object Descriptions The iDRAC property database contains the configuration information for iDRAC. Associated object is organizing data, and object group is organizing object. The IDs for the groups and objects that the property database supports are listed in this section for iDRAC Enterprise on Blade Servers and iDRAC Enterprise or Express on Rack and Tower Servers. To configure iDRAC, use the group and object IDs with the RACADM subcommands.
• cfgUserDomain • cfgServerPower • cfgServerPowerSupply • cfgIPv6LanNetworking • cfgIpv6StaticLanNetworking • cfgIPv6URL • cfgIpmiSerial • cfgSmartCard • cfgNetTuning • cfgSensorRedundancy • cfgVFlashSD • cfgVFlashPartition • cfgLogging • cfgRacSecurity Displayable Characters Displayable characters include the following set: abcdefghijklmnopqrstuvwxwz ABCDEFGHIJKLMNOPQRSTUVWXYZ 0123456789~`!@#$%^&*()_+-={}[]|\:";'<>,.?/ Table 109.
Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers cfgLDAP Yes Yes cfgLdapRoleGroup Yes Yes cfgStandardSchema Yes Yes cfgIpmiSol Yes Yes cfgIpmiLan Yes Yes cfgIpmiPetIpv6 Yes Yes cfgIpmiPef Yes Yes cfgIpmiPet Yes Yes cfgUserDomain Yes Yes cfgServerPower Yes Yes cfgServerPowerSupply No Yes cfgIPv6LanNetworking Yes Yes cfgIPv6URL Yes Yes cfgIpmiSerial No Yes cfgSmartCard Yes Yes cfgNetTuning No Yes cfgSensorRedundancy No Yes cfgVFlashSD Yes
idRacProductInfo (Read Only) Table 110. Details of Read only attribute - idRacProductInfo Description A text string that identifies the product. Legal Values A string of up to 63 ASCII characters. Default iDRAC – Integrated Dell Remote Access Controller idRacDescriptionInfo (Read Only) Table 111. Details of Read only attribute - idRacDescriptionInfo Description A text description of the RAC type. Legal Values A string of up to 255 ASCII characters.
idRacName (Read Only) Table 114. Details of Read only attribute - idRacName Description A user-assigned name to identify this controller. Legal Values A string of up to 15 ASCII characters. Default iDRAC iDRAC Type (Read Only) Table 115. Details of Read only attribute - iDRAC Type Description Identifies the remote access controller type.
cfgNicStaticEnable (Read or Write) Table 116. Details of cfgNicStaticEnable Description Enables or disables the NIC. Legal Values • 0 — Disabled • 1 — Enabled Default 1 — Enabled NOTE: If this object is modified, then the object cfgNicEnable is also modified. cfgNicStaticIPv4Enable (Read or Write) Table 117. Details of cfgNicStaticIPv4Enable Description Enables or disables the IPv4 stack.
cfgNicStaticUseDhcp (Read or Write) Table 119. Details of cfgNicStaticUseDhcp Description Specifies whether DHCP is used to configure the IPv4 network. Legal Values • 0 — IP Address, subnet mask and gateway are configured on the device. • 1 — IP Address, subnet mask and gateway are assigned from the DHCP server. 0 — Do not use DHCP Default NOTE: If this object is modified, then the object cfgNicUseDhcp is also modified. cfgNicStaticNetmask (Read or Write) Table 120.
Default 0 cfgDNSStaticServer1 (Read or Write) Table 123. Details of cfgDNSStaticServer1 Description Specifies the IP address for DNS server 1. NOTE: This property is only valid if cfgDNSServersFromDHCP is set to 0 (FALSE). Legal Values Default • 0 — IP Address, subnet mask and gateway are configured on the device. • 1 — IP Address, subnet mask and gateway are assigned from the DHCP server. 0 — Do not use DHCP NOTE: If this object is modified, then the object cfgNicUseDhcp is also modified.
cfgDNSStaticDomainNameFromDHCP (Read or Write) Table 126. Details of cfgDNSStaticDomainNameFromDHCP Description Specifies the device DNS static domain name. Legal Values • 0 — Do not use DHCP to get the Domain Name • 1 — Use DHCP to get the Domain Name 0 — Disabled Default cfgRemoteHosts This group provides properties that allow configuration of the SMTP server for email alerts. To apply this setting to iDRAC, use the —m option. Use this object with the config or getconfig subcommands.
cfgRhostsFwUpdatePath (Read or Write) Table 129. Details of attribute - cfgRhostsFwUpdatePath Description Specifies TFTP path where firmware image file exists on the TFTP server. The TFTP path is relative to the TFTP root path on the TFTP server. NOTE: The server may still require you to specify the drive (for example, C:). Legal Values A string with a maximum length of 255 ASCII characters. Default cfgRhostsSmtpServerIpAddr (Read or Write) Table 130.
cfgRhostsSyslogServer1 Read or Write) Table 133. Details of attribute - cfgRhostsSyslogServer1 Description To store the RAC and SEL logs specify the first of three possible remote syslog servers. This property is only valid if cfgRhostsSyslogEnable is set to 1 (enabled). Legal Values String from 0 to 63 characters. Default cfgRhostsSyslogServer2 Read or Write) Table 134.
cfgUserAdminIndex - Read Only Table 136. Details of cfgUserAdminIndex attribute Description The unique index of a user. Legal Values This parameter is populated based on the existing instances. Default cfgUserAdminIpmiLanPrivilege (Read or Write) Table 137. Details of cfgUserAdminIpmiLanPrivilege Description The maximum privilege on the IPMI LAN channel.
cfgUserAdminPrivilege - Read or Write Table 139. Details of cfgUserAdminPrivilege attribute Description This property specifies the role-based authority privileges allowed for the user. The value is represented as a bit mask that allows for any combination of privilege values. The table below describes the user privilege bit values that can be combined to create bit masks. Legal Values 0x00000000 to 0x000001ff, and 0x0 Default 0x00000000 Table 140.
Chassis Control Administrator 0x0000010 Super User 0x0000020 Server Administrator 0x0000040 Test Alert User 0x0000080 Debug Command Administrator 0x0000100 Fabric A Administrator 0x0000200 Fabric B Administrator 0x0000400 Fabric C Administrator 0x0000800 Table 141. Examples User Privileges Privilege Bit Mask The user is not allowed to access iDRAC or CMC 0x00000000 The user may only log in to iDRAC or CMC and view iDRAC or CMC and server configuration information.
cfgUserAdminUserName - Read or Write Table 142. Details of cfgUserAdminUserName attribute Description The name of the user for this index. Writing a string of double quotation mark (" ") disables the user. The string cannot contain / (forward slash), \ (backward slash), . (period), @ (at symbol), quotation marks, ; (semicolon), or ‘ (backward quotation mark). NOTE: This property value must be unique among user names. Legal Values A string of up to 16 ASCII characters.
cfgUserAdminSolEnable (Read or Write) Table 145. Details of cfgUserAdminSolEnable Description Enables or disables Serial Over LAN (SOL) user access for the user. Legal Values • 1 (TRUE) • 0(FALSE) Default 0 cfgEmailAlert This group contains parameters to configure iDRAC email alerting capabilities. Up to four instances of this group are allowed. Use this object with the config or getconfig subcommands. The following sections provide information about the objects in the cfgEmailAlert group.
cfgEmailAlertAddress - Read or Write Table 148. Details of cfgEmailAlertAddress attribute Description Specifies the destination email address for email alerts, for example, user1@company.com. Legal Values Email address format, with a maximum length of 64 ASCII characters. Default cfgEmailAlertCustomMsg (Read or Write) Table 149. Details of cfgEmailAlertCustomMsg Description Specifies a custom message that forms the subject of the alert.
cfgSsnMgtRacadmTimeout (Read or Write) Table 151. Details of cfgSsnMgtRacadmTimeout attribute Description Defines the idle timeout in seconds for the Remote RACADM interface. If a remote RACADM session remains inactive for more than the specified sessions, the session closes.
cfgSsnMgtSshIdleTimeout (Read or Write) Table 154. Details of cfgSsnMgtSshIdleTimeout attribute Description Defines the secure shell idle time-out. This property sets the amount of time (in seconds) that a connection is allowed to remain idle (there is no user input). The session is canceled if the time limit exceeds this property. Changes to this setting do not affect the current session; log out and log in again to make the new settings effective.
Use this object with the config or getconfig subcommands. The following sections provide information about the objects in the cfgSerial group. NOTE: The cfgSerial object group is applicable for iDRAC Enterprise on Blade Servers for only two properties — cfgSerialTelnetEnable=1 and cfgSerialSshEnable=1. cfgSerialBaudRate - Read or Write Table 156. Details of cfgSerialBaudRate attribute Description Sets the baud rate on the serial port.
Default: \ cfgSerialConsoleIdleTimeout - Read or Write Table 159. Details of cfgSerialConsoleIdleTimeout attribute Description The maximum number of seconds to wait before an idle serial session is disconnected. Legal Values • 0 = No timeout • 60–1920 300 Default cfgSerialConsoleNoAuth - Read or Write Table 160. Details of cfgSerialConsoleNoAuth attribute Description Legal Values Enables or disables the serial console login authentication.
cfgSerialCom2RedirEnable (Read or Write) Table 163. Details of cfgSerialCom2RedirEnable Description Enables or disables the console for COM 2-port redirection. The cfgSerialCom2RedirEnable object property is applicable only for iDRAC on Rack and Tower Servers. Legal Values Default • 1 (TRUE) • 0 (FALSE) 1 cfgSerialHistorySize - Read or Write Table 164. Details of cfgSerialHistorySize attribute Description Specifies the maximum size of the serial history buffer.
cfgSerialTelnetEnable - Read or Write Table 166. Details of cfgSerialTelnetEnable attribute Description Enables or disables the Telnet console interface. Legal Values • 1 (TRUE) • 0 (FALSE) 0 Default cfgOobSnmp This group contains parameters to configure the SNMP agent and trap capabilities of iDRAC. One instance of the group is allowed. The CMC SNMP agent supports the standard RFC1213 mib-2 and the Dell enterprise-specific the MIB. This group is not applicable for iDRAC on Rack and Tower Servers.
• Default 0 (FALSE) 0 cfgRacTuning This group is used to configure various configuration properties, such as valid ports and security port restrictions. Use this object with the config or getconfig subcommands. To apply this setting to iDRAC, use the —m option. The following sections provide information about the objects in the cfgRacTuning group. cfgRacTuneConRedirPort (Read or Write) Table 169.
0 Default cfgRacTuneHttpPort (Read or Write) Table 172. Details of cfgRacTuneHttpPort attribute Description To use HTTP network communication, specify the port number. Legal Values 10–65535 Default 80 cfgRacTuneHttpsPort (Read or Write) Table 173. Details of cfgRacTuneHttpsPort attribute Description To use HTTPS network communication, specify the port number. Legal Values 10–65535 Default 443 cfgRacTuneIpRangeEnable (Read or Write) Table 174.
cfgRacTuneIpRangeMask (Read or Write) Table 176. Details of cfgRacTuneIpRangeMask attribute Description Standard IP mask values with left-justified bits. For example, 255.255.255.0. Legal Values An IPv4 address formatted string, for example, 255.255.255.0. Default 255.255.255.0 cfgRacTuneSshPort (Read or Write) Table 177. Details of cfgRacTuneSshPort attribute Description Specifies the port number used for the SSH interface.
cfgRacTuneConRedirEncryptEnable (Read or Write) Table 180. Details of cfgRacTuneConRedirEncryptEnable Description Encrypts the video in a Virtual Console session. Legal Values • 1 (TRUE) • 0 (FALSE) 1 Default cfgRacTuneAsrEnable (Read or Write) Table 181. Details of cfgRacTuneAsrEnable Description Enables or disables iDRAC last crash screen capture feature. This object property requires an iDRAC reset before it becomes active.
cfgRacTuneIpRangeAddr=192.168.1.1 cfgRacTuneIpRangeMask=255.255.255.0 # cfgRacTuneTimezoneOffset=-18000 # cfgRacTuneDaylightOffset=3600 cfgRacTuneTimezoneOffset (Read Only) Table 183. Details of cfgRacTuneTimezoneOffset attribute Description Specifies the time zone offset (in minutes) from Greenwich Mean Time (GMT) / Coordinated Universal Time (UTC) to use for the RAC Time.
cfgRacTuneLocalConfigDisable (Read or Write) Table 185. Details of cfgRacTuneLocalConfigDisable attribute Description Disables write access to iDRAC configuration data. NOTE: Access can be disabled using the local RACADM or iDRAC web interface; however, once disabled, access can be re-enabled only through iDRAC web interface. Legal Values • 0 (TRUE-Enables) • 1 (FALSE-Disables) 0 Default cfgRacTuneWebserverEnable (Read or Write) Table 186.
2 — (If the user of the first session has not responded for session sharing request by subsequent user. The next session user gets administrator access after default timeout value of 30 seconds.) Default 0 cfgRacTunePluginType (Read or Write) Table 188. Details of cfgRacTunePluginType Description To virtual console from browser, specifies the plug-in type.
The following sections provide information about the objects in the cfgRacVirtual. cfgVirMediaAttached (Read or Write) Table 191. Details of cfgVirMediaAttached Description This object is used to attach virtual devices to the system via the USB bus. When the devices are attached, the server recognizes valid USB mass storage devices attached to the system. Which is equivalent to attaching a local USB CDROM/floppy drive to a USB port on the system.
Default 0 cfgSDWriteProtect (Read Only) Table 194. Details of cfgSDWriteProtect Description Displays if the physical write protect latch on the SD card is enabled or disabled. NOTE: This command is deprecated from 12G iDRAC 1.0 release onwards. The functionality of this command is covered by cfgVFlashSDWriteProtect. While execution of the cfgSDWriteProtect command is successful, use the cfgVFlashSDWriteProtect command. For more information, see cfgVFlashSDWriteProtect Read Only.
cfgServerNic4MacAddress (Read Only) Table 197. Details of cfgServerNic4MacAddress Description Displays the MAC address of the server NIC 4. Legal Values None Default None cfgServerDNSIMCName (Read or Write) Table 198. Details of cfgServerDNSIMCName attribute Description Displays the DNS domain name for iDRAC or IMC. Legal Values A valid string values Default None cfgServerFirstBootDevice (Read or Write) Table 199.
• • • Default RFS (Remote File Share) F10 F11 No-Override cfgServerBootOnce (Read or Write) Table 200. Details of cfgServerBootOnce Description Enables or disables the server start once feature. Legal Values • 1(True) • 0 (False) Default 1(True) cfgActiveDirectory This group contains parameters to configure iDRAC Active Directory feature. Use this object with the config or getconfig subcommands. The following sections provide information about the objects in the cfgActiveDirectory.
cfgADDomainController2 (Read or Write) Table 203. Details of cfgADDomainController2 To obtain user names, specify the LDAP server from which you want the iDRAC. Description This object is applicable only to iDRAC. Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name (FQDN). Default None cfgADDomainController3 (Read or Write) Table 204.
cfgADAuthTimeout (Read or Write) Table 207. Details of cfgADAuthTimeout attribute Description To wait for Active Directory authentication requests to complete before timing out, specify the number of seconds. NOTE: To modify this property, you must have the Configure iDRAC permission. Legal Values 15–300 seconds Default 120 cfgADEnable (Read or Write) Table 208. Details of cfgADEnable attribute Description Enables or disables Active Directory user authentication on iDRAC.
This object is applicable only to iDRAC. Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name (FQDN). Default None cfgADGlobalCatalog2 (Read or Write) Table 211. Details of cfgADGlobalCatalog2 Description To obtain user names, specify the Global Catalog server from which you want the iDRAC. This object is applicable only to iDRAC.
cfgADDcSRVLookupEnable (Read or Write) Table 214. Details of cfgADDcSRVLookupEnable Description Configures iDRAC to use pre‑configured domain controllers or to use DNS to find the domain controller. If using pre‑configured domain controllers, then the domain controllers to use are specified under cfgAdDomainController1 ,cfgAdDomainController2 and cfgAdDomainController3.
cfgADGcSRVLookupEnable (Read or Write) Table 217. Details of cfgADGcSRVLookupEnable Description Determines how the global catalog server is looked up. If using pre‑configured global catalog servers, then iDRAC uses the values cfgAdGlobalCatalog1, cfgAdGlobalCatalog2 and cfgAdGlobalCatalog3. This object is applicable only to iDRAC. Legal Values • 0(FALSE) — use pre‑configured Global Catalog Servers (GCS) • 1(TRUE) — use DNS to look up GCS 0 Default cfgADGcRootDomain (Read or Write) Table 218.
cfgLDAPServer (Read or Write) Table 220. Details of cfgLDAPServer attribute Description Configures the address of the LDAP Server. IPv4 and IPv6 are supported. NOTE: You can specify multiple servers by separating each server with a comma. For example, example.com, sub1.example.com Legal Values String. Maximum length = 1024 Default Null cfgLDAPPort (Read or Write) Table 221. Details of cfgLDAPPort attribute Description Port of LDAP over SSL. Non-SSL port is not supported.
Null Default cfgLDAPGroupAttribute (Read or Write) Table 224. Details of cfgLDAPGroupAttribute attribute Description Specifies which LDAP attribute is used to check for group membership. It must be an attribute of the group class. If not specified then the member and unique member attributes are used. Legal Values String maximum length = 254 Default Null cfgLDAPGroupAttributeIsDN (Read or Write) Table 225.
cfgLDAPBindPassword (Write Only) Table 227. Details of cfgLDAPBindPassword attribute Description A bind password is used with the bindDN. The bind password is a sensitive data, and must be protected. It is optional to support anonymous bind. Legal Values String maximum length = 254 Default Null cfgLDAPSearchFilter (Read or Write) Table 228.
cfgLDAPSRVLookupServiceName (Read or Write) Table 231. Details of cfgLDAPSRVLookupServiceName attribute Description To use in the SRV lookup, configure the service name. Legal Values String of maximum length of 254 characters. Default LDAP cfgLdapRoleGroup This group allows the user to configure role groups for LDAP. Use this object with the config or getconfig subcommands. cfgLDAPRoleGroup is indexed, containing instances numbered from 1 to 5.
Example racadm getconfig -g cfgLDAPRoleGroup -o cfgLDAPRoleGroupDN -i 1 cn=everyone,ou=groups,dc=openldap,dc=com cfgLdapRoleGroupPrivilege (Read or Write) Table 234. Details of cfgLdapRoleGroupPrivilege Description A bit–mask defining the privileges associated with this particular group.
cfgSSADRoleGroupDomain (Read or Write) Table 237. Details of cfgSSADRoleGroupDomain attribute Description Active Directory Domain in which the Role Group resides. Legal Values Any printable text string of up to 254 characters, with no white space. Default cfgSSADRoleGroupPrivilege (Read or Write) Table 238. Details of cfgSSADRoleGroupPrivilege attribute Description Use the bit mask numbers listed in the table below to set role-based authority privileges for a Role Group.
cfgThermalEnhancedCoolingMode (Read or Write) Table 240. Details of cfgThermalEnhancedCoolingMode attribute Description Configures the enhanced cooling mode. Legal Values • 1 — Enabled • 0 — Disabled Default 0 — Disabled cfgIpmiSol This group is used to configure the Serial Over LAN (SOL) capabilities of the system. The following sections provide information about the objects in the cfgIpmiSol group. cfgIpmiSolEnable (Read or Write) Table 241.
cfgIpmiSolMinPrivilege (Read or Write) Table 243. Details of cfgIpmiSolMinPrivilege Description Specifies the minimum privilege level required for SOL access. Legal Values • 2(User) • 3(Operator) • 4(Administrator) 4 Default cfgIpmiSolAccumulateInterval (Read or Write) Table 244. Details of cfgIpmiSolAccumulateInterval Description Specifies the typical amount of time that iDRAC waits before transmitting a partial SOL character data packet. This value is 1-based 5ms increments.
cfgIpmiLanEnable (Read or Write) Table 246. Details of cfgIpmiLanEnable Description Enables or disables the IPMI over LAN interface. Legal Values • 1(TRUE) • 0(FALSE) Default 0 cfgIpmiLanPrivLimit (Read or Write) Table 247. Details of cfgIpmiLanPrivLimit Description Specifies the maximum privilege level allowed for IPMI over LAN access. Legal Values • 2(User) • 3(Operator) • 4(Administrator) \Default 4 cfgIpmiLanAlertEnable (Read or Write) Table 248.
0000000000000000000000000000000000000000 Default cfgIpmiLanPetCommunityName (Read or Write) Table 250. Details of cfgIpmiLanPetCommunityName Description Specifies the SNMP community name for traps. Legal Values A string of up to 18 characters. Default public cfgIpmiPetIpv6 This group is used to configure IPv6 platform event traps on the managed server. The following sections provide information about the objects in the cfgIpmiPetIpv6 group. cfgIpmiPetIPv6Index (Read Only) Table 251.
cfgIpmiPetIPv6AlertEnable (Read or Write) Table 253. Details of cfgIpmiPetIPv6AlertEnable Description Enables or disables the IPv6 alert destination for the trap. Legal Values • 1 (TRUE) • 0 (FALSE) Default 0 cfgIpmiPef This group is used to configure the platform event filters available on the managed server. The event filters can be used to control policy related to actions that are triggered when critical events occur on the managed server.
cfgIpmiPefAction (Read or Write) Table 256. Details of cfgIpmiPefAction Description Specifies the action that is performed on the managed server when the alert is triggered. NOTE: For iDRAC on Rack and Tower servers, this object is read-only for indexes 20, 21, and 22. Legal Values • 0 (None) • 1 (Power Down) • 2(Reset) • 3(Power Cycle) 0 Default cfgIpmiPefEnable (Read or Write) Table 257. Details of cfgIpmiPefEnable Description Enables or disables a specific platform event filter.
cfgIpmiPetAlertDestIpAddr (Read/Write) Table 259. Details of cfgIpmiPetAlertDestIpAddr Description Specifies the destination IPv4 address for the trap receiver on the network. The trap receiver receives an SNMP trap when an event is triggered on the managed server. Legal Values A string representing a valid IPv4 address. For example, 192.168.0.67. Default 0.0.0.0 cfgIpmiPetAlertEnable (Read or Write) Table 260. Details of cfgIpmiPetAlertEnable Description Enables or disables a specific trap.
cfguserdomainname (Read Only) Table 262. Details of cfguserdomainname Description Specifies the Active Directory user domain name. Legal Values A string of up to 254 ASCII characters Default cfgServerPower This group provides several power management features. The following sections provide information about the objects in the cfgServerPower group. cfgServerPowerStatus (Read Only) Table 263. Details of cfgServerPowerStatus Description Represents the server power state, either ON or OFF.
cfgServerActualPowerConsumption (Read Only) Table 265. Details of cfgServerActualPowerConsumption Description Represents the power consumption by the server at the current time. Legal Values Not applicable Default cfgServerPowerCapEnable (Read or Write) Table 266. Details of cfgServerPowerCapEnable Description Enables or disables the user specified power budget threshold. This object is Read only for iDRAC Enterprise on Blade Servers.
cfgServerPeakPowerConsumption (Read Only) Table 269. Details of cfgServerPeakPowerConsumption Description Represents the servers maximum power consumption until the current time. Legal Values Not applicable Default Peak power consumption of the server cfgServerPeakPowerConsumptionTimestamp (Read Only) Table 270. Details of Description Specifies time when the maximum power consumption was recorded. Legal Values A string of up to 32 characters.
cfgServerPowerCapBtuhr (Read or Write) Table 273. Details of cfgServerPowerCapBtuhr Description Represents the server power threshold in BTU/hr. NOTE: This value is applicable only if cfgServerPowerCapEnable is set to 1. Legal Values None Default Server power threshold in BTU/hr. cfgServerPowerCapPercent (Read or Write) Table 274. Details of cfgServerPowerCapPercent Description Represents the server power threshold in percentage.
cfgServerPowerLastWeekAvg (Read Only) Table 277. Details of cfgServerPowerLastWeekAvg Description Displays the average power value during the last week. Legal Values None Default Average power value during the last week. cfgServerPowerLastHourMinPower (Read Only) Table 278. Details of cfgServerPowerLastHourMinPower Description Displays the minimum power value during the last hour. Legal Values Not applicable Default Minimum power value during the last hour.
cfgServerPowerLastHourMaxPower (Read Only) Table 280. Details of cfgServerPowerLastHourMaxPower Description Displays the maximum power value during the last hour. Legal Values Not applicable Default Maximum power value during the last hour. cfgServerPowerLastHourMaxTime (Read Only) Table 281. Details of cfgServerPowerLastHourMaxTime Description Displays the timestamp of maximum power value during the last hour.
cfgServerPowerLastDayMinTime (Read Only) Table 283. Details of cfgServerPowerLastDayMinTime Description Displays the timestamp of minimum power value during the last day. Legal Values Time in the format: DD MM Date HH:MM:SS YYYY where, • • • • • • • DD = Day of the week MM = Month Date = Date YYYY = Year HH = hour MM = Minutes SS = Seconds Timestamp of the minimum power value during the last day. Default cfgServerPowerLastDayMaxPower (Read Only) Table 284.
Default Timestamp of the maximum power value during the last day. cfgServerPowerLastWeekMinPower (Read Only) Table 286. Details of cfgServerPowerLastWeekMinPower Description Displays the minimum power value during the last week. Legal Values Not applicable Default Minimum power value during the last week. cfgServerPowerLastWeekMinTime (Read Only) Table 287. Details of cfgServerPowerLastWeekMinTime Description Displays the timestamp of minimum power value during the last week.
cfgServerPowerLastWeekMaxTime (Read Only) Table 289. Details of cfgServerPowerLastWeekMaxTime Description Displays the timestamp of maximum power value during the last week. Legal Values A string of up to 32 characters. Time in the format: DD MM Date HH:MM:SS YYYY where, • • • • • • • Default DD = Day of the week MM= Month Date = Date YYYY = Year HH = hour MM = Minutes SS = Seconds Timestamp of the maximum power value during the last week. cfgServerPowerInstHeadroom (Read Only) Table 290.
cfgServerActualAmperageConsumption (Read Only) Table 292. Details of cfgServerActualAmperageConsumption Description Displays the current power consumption. Legal Values Not applicable Default Current power consumption. cfgServerPeakAmperage (Read Only) Table 293. Details of cfgServerPeakAmperage Description Displays the current peak power consumption. Legal Values Not applicable Default Current peak power consumption. cfgServerPeakAmperageTimeStamp (Read Only) Table 294.
cfgServerCumulativePowerConsumption (Read Only) Table 295. Details of cfgServerCumulativePowerConsumption Description Displays the cumulative power consumption. Legal Values Not applicable Default Cumulative power consumption. cfgServerCumulativePowerConsumptionTimeStamp (Read Only) Table 296. Details of cfgServerCumulativePowerConsumptionTimeStamp Description Displays the timestamp of the cumulative power consumption. Legal Values A string of up to 32 characters.
cfgServerPowerPCIeAllocation (Read or Write) Table 298. Details of cfgServerPowerPCIeAllocation Description Amount of power allocated to the PCIe cards. This object is applicable for iDRAC Enterprise only for specific Blade Servers and not for iDRAC on Rack and Tower Servers. You must have the Administrator privileges to modify the value for this object. Legal Values 0 W: For platforms that do not support PCIe cards. 100 W — 500 W: For platforms that support PCIe cards.
cfgServerPowerSupplyMaxInputPower (Read Only) Table 300. Details of cfgServerPowerSupplyMaxInputPower Description Displays the AC input rated power in Watts. Legal Values A string of up to 32 characters. Default 0 cfgServerPowerSupplyMaxOutputPower (Read Only) Table 301. Details of cfgServerPowerSupplyMaxOutputPower Description Displays the AC output rated power in Watts. Legal Values A string of up to 32 characters. Default 0 cfgServerPowerSupplyOnlineStatus (Read Only) Table 302.
cfgServerPowerSupplyCurrentDraw (Read Only) Table 304. Details of cfgServerPowerSupplyCurrentDraw Description Displays the instantaneous current consumption in 0.1 amps. Legal Values A string of up to 32 characters. Default 0 cfgServerPowerSupplyType Table 305. Details of cfgServerPowerSupplyType Description Displays whether the power supply is AC or DC. Legal Values A string of up to 32 characters.
cfgIPv6Address1 (Read or Write) Table 307. Details of cfgIPv6Address1 Description Specifies iDRAC IPv6 address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Gateway (Read or Write) Table 308. Details of cfgIPv6Gateway attribute Description iDRAC gateway IPv6 address. Legal Values Specifies string representing a valid IPv6 entry. Default “ :: “ cfgIPv6AutoConfig (Read or Write) Table 309.
NOTE: • Legal Values 1–128 Default 64 This property can be configured even when cfgIPv6AutoConfig is enabled. cfgIPv6LinkLocalAddress (Read Only) Table 311. Details of cfgIPv6LinkLocalAddress Description The iDRAC IPv6 link local address. Legal Values Specifies a string representing a valid IPv6 entry. Default : cfgIPv6Address2 (Read Only) Table 312. Details of cfgIPv6Address2 Description The iDRAC IPv6-second address. Legal Values A string representing a valid IPv6 entry.
cfgIPv6Address4 (Read Only) Table 314. Details of cfgIPv6Address4 Description The iDRAC IPv6 fourth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address5 (Read Only) Table 315. Details of cfgIPv6Address5 Description The iDRAC IPv6 fifth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address6 (Read Only) Table 316. Details of cfgIPv6Address6 Description The iDRAC IPv6 sixth address.
cfgIPv6Address8 (Read Only) Table 318. Details of cfgIPv6Address8 Description The iDRAC IPv6 eighth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address9 (Read Only) Table 319. Details of cfgIPv6Address9 Description The iDRAC IPv6 ninth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address10 (Read Only) Table 320. Details of cfgIPv6Address10 Description The iDRAC IPv6 tenth address.
cfgIPv6Address12 (Read Only) Table 322. Details of cfgIPv6Address12 Description The iDRAC IPv6 twelfth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address13 (Read Only) Table 323. Details of cfgIPv6Address13 Description The iDRAC IPv6 thirteenth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address14 (Read Only) Table 324. Details of cfgIPv6Address14 Description The iDRAC IPv6 fourteenth address.
cfgIPv6DNSServersFromDHCP6 (Read or Write) Table 326. Details of cfgIPv6DNSServersFromDHCP6 attribute Description Specifies whether cfgIPv6DNSServer1 and cfgIPv6DNSServer2 are static or DHCP IPv6 addresses. NOTE: This property is used only if cfgIPv6AutoConfig is set to 1(true). Legal Values 1 (TRUE) 0 (FALSE) Default 0 cfgIPv6DNSServer1 (Read or Write) Table 327. Details of cfgIPv6DNSServer1 attribute Description Specifies the IPv6 DNS server address.
cfgIPv6StaticAddress1 (Read or Write) Table 329. Details of cfgIPv6StaticAddress1 Description Returns or sets the static IPv6 address1. NOTE: Only set the current IPv4 address if cfgNicUseDhcp is set to 0 (false). Legal Values Any IPv6 address Default cfgIPv6StaticGateway (Read or Write) Table 330. Details of cfgIPv6StaticGateway Description Returns or sets gateway static IPv6 address. Legal Values Any IPv6 address Default cfgIPv6StaticPrefixLength (Read or Write) Table 331.
cfgIPv6StaticDNSServersFromDHCP6 (Read or Write) Table 333. Details of cfgIPv6StaticDNSServersFromDHCP6 Description Specifies the DNS server static IP addresses. Legal Values • 0 — DNS Server must be configured as static. • 1 — The device will get the DNS servers from DHCPv6. Default 0 — Disabled cfgIPv6StaticDNSServer1 (Read or Write) Table 334. Details of cfgIPv6StaticDNSServer1 Description Specifies the DNS server 1 static IPv6 address.
Example $ racadm getconfig -g cfgIPv6LanNetworking cfgIPv6Enable=1 cfgIPv6AutoConfig=1 cfgIPv6Address=:: cfgIPv6PrefixLength=64 cfgIPv6Gateway=:: cfgIPv6DNSServersFromDHCP6=1 cfgIPv6DNSServer1=:: cfgIPv6DNSServer2=:: If both IPv4 and IPv6 are enabled on the iDRAC, IPv6 DNS servers take priority. The order of preference for DNS servers is: • cfgIPv6DNSServer1 • cfgIPv6DNSServer2 • cfgDNSServer1 • cfgDNSServer2 cfgIPv6URL This group specifies properties used to configure iDRAC IPv6 URL.
cfgIpmiSerialBaudRate (Read or Write) Table 338. Details of cfgIpmiSerialBaudRate Description Specifies the baud rate for a serial connection over IPMI. Legal Values 9600, 19200, 57600, 115200 Default 57600 cfgIpmiSerialChanPrivLimit (Read or Write) Table 339. Details of cfgIpmiSerialChanPrivLimit Description Legal Values Default Specifies the maximum privilege level allowed on the IPMI serial channel.
cfgIpmiSerialDeleteControl (Read or Write) Table 341. Details of cfgIpmiSerialDeleteControl Description Enables or disables delete control on the IPMI serial interface. Legal Values • 0 (FALSE) • 1 (TRUE) 0 Default cfgIpmiSerialEchoControl (Read or Write) Table 342. Details of cfgIpmiSerialEchoControl Description Enables or disables echo control on the IPMI serial interface. Legal Values • 0(FALSE) • 1 (TRUE) 1 Default cfgIpmiSerialFlowControl (Read or Write) Table 343.
Default 1 cfgIpmiSerialNewLineSequence (Read or Write) Table 345. Details of cfgIpmiSerialNewLineSequence Description Specifies the new line sequence specification for the IPMI serial interface. Legal Values • 0 — None • 1 — CR-LF • 2 — NULL • 3 — CR • 4 — LF-CR • 5 — LF Default 1 cfgIpmiSerialLineEdit (Read or Write) Table 346. Details of cfgIpmiSerialLineEdit Description Enables or disables line editing on the IPMI serial interface.
The following sections provide information about the objects in the cfgSmartCard group. cfgSmartCardLogonEnable (Read or Write) Table 348. Details of cfgSmartCardLogonEnable Description To iDRAC using a smart card, enable or disable with Remote RACADM support for access. NOTE: Enabling with remote RACADM is only applicable for iDRAC on Rack and Tower Servers. Legal Values • 0 (Disabled) • 1 (Enabled) • 2 (Enabled with Remote RACADM) — It is not applicable for iDRAC Enterprise on Blade Servers.
cfgNetTuningNicAutoneg (Read or Write) Table 350. Details of cfgNetTuningNicAutoneg attribute Description Enables auto negotiation of physical link speed and duplex. If enabled, auto negotiation takes priority over other values set in this group.
cfgNetTuningNicFullDuplex (Read or Write) Table 352. Details of cfgNetTuningNicFullDuplex attribute Description Specifies the duplex setting for the NIC. This property is used only if thecfgNetTuningNicAutoNeg is set to 0 (disabled). Legal Values • 0 (Half Duplex) • 1 (Full Duplex) 1 Default cfgNetTuningNicMtu (Read or Write) Table 353. Details of cfgNetTuningNicMtu attribute Description Indicated the maximum size of units in bytes transmitted by NIC.
cfgSensorRedundancyPolicy (Read or Write) Table 355. Details of cfgSensorRedundancyPolicy Description Sets the power supply redundancy policy. Legal Values • 2 — N/A, for systems that are not supported • 3 — Non Redundant • 4–1+1 Redundant • 4–2+1 Redundant • 16–2+2 Redundant Default Any legal value at that particular execution instance. cfgSensorRedundancyCapabilities (Read Only) Table 356.
cfgVFlashSD This group is used to configure the properties for the Virtual Flash SD card. NOTE: If the vFlash card is present but is not enabled, the query for any property under this group displays: ERROR: vFlash is not enabled. To view the properties of this group, enable the vFlash using the command: racadm config -g cfgvFlashSD -o cfgvFlashSDEnable 1 The following sections provide information about the objects in the cfgVFlashSD group. cfgVFlashSDInitialized (Read Only) Table 358.
cfgVFlashSDLicensed (Read Only) Table 361. Details of cfgVFlashSDLicensed Description Displays whether an SD card or vFlash SD card is inserted. The vFlash SD card supports the new enhanced vFlash features and the SD card supports only the limited vFlash features. Legal Values • 0(SD card is inserted) • 1(vFlash SD card is inserted) Default None cfgVFlashSDAvailableSize (Read Only) Table 362.
• 1 (vFlash is write-protected) None Default cfgVFlashPartition This group is used to configure properties for individual partitions on the vFlash SD Card. Up to 16 partitions are supported, indexed from 1 to 16. NOTE: For SD cards, the index value is limited to 1 because only a single partition of size 256MB is allowed. The following sections provide information about the objects in the cfgVFlashPartition group. cfgVFlashPartitionIndex (Read Only) Table 365.
cfgVFlashPartitionFlashOSVolLabel (Read Only) Table 368. Details of cfgVFlashPartitionFlashOSVolLabel Description Displays the label for the partition that is visible to the operating system. Legal Values An alphanumeric string of up to six characters. Default None cfgVFlashPartitionFormatType (Read Only) Table 369. Details of cfgVFlashPartitionFormatType Description Displays the format type of the partition.
NOTE: Detaching the vFlashPartition by setting the cfgVFlashPartitionAttachState to 0 does not require a license. Legal Values • 1 — Attached • 0 — Detached 0 — Detached Default cfgLogging This group contains parameters to enable or disable the OEM event log filtering. The following section provide information about the objects in the cfgLogging group: cfgLoggingSELOEMEventFilterEnable (Read or Write) Table 372.
cfgRacSecCsrOrganizationName (Read or Write) Table 374. Details of cfgRacSecCsrOrganizationName attribute Description Specifies the CSR Organization Name (O). Legal Values A string of up to 64 characters. Default cfgRacSecCsrOrganizationUnit (Read or Write) Table 375. Details of cfgRacSecCsrOrganizationUnit attribute Description Specifies the CSR Organization Unit (OU). Legal Values A string of up to 64 characters. Default cfgRacSecCsrLocalityName (Read or Write) Table 376.
cfgRacSecCsrCountryCode (Read/Write) Table 378. Details of cfgRacSecCsrCountryCode attribute Description Specifies the CSR Country Code (CC). Legal Values A string of 2 alphabet country code. Default US cfgRacSecCsrEmailAddr (Read or Write) Table 379. Details of cfgRacSecCsrEmailAddr attribute Description Specifies the CSR email address. Legal Values A string of up to 64 characters.
4 Database Objects With Get and Set Commands This chapter provides the database groups and objects that must be used with the get or set subcommands. When using the objects, they must begin with FQDD or FQDD alias. The set operations for iDRAC, Lifecycle Controller and system objects do not require server restart. However, the set operations for NIC and BIOS objects are staged and job creation and server restart is required to apply and commit the pending values.
Usage -- NoRetry - 0;1Retry - 1; 2Retries - 2;3Retries - 3;4Retries - 4; 5Retries - 5;6Retries- 6; IndefiniteRetries, Default - NoRetry Required License -- RACADM Dependency -- None BootStrapType system.
Topics: • System.Backplane • System.ChassisControl • System.ChassisInfo • System.OpenIDConnectServer • System.QuickSync • System.LCD • System.Location • System.OpenIDConnectServer • System.Power • System.Power.Supply • System.ServerOS • System.ThermalSettings • System.ThermalConfig • LifecycleController.LCAttributes • iDRAC.ActiveDirectory • iDRAC.ADGroup • iDRAC.AutoOSLock • iDRAC.EmailAlert • iDRAC.Info • iDRAC.IOIDOpt • iDRAC.IPBlocking • iDRAC.
• iDRAC.SerialRedirection • iDRAC.serverboot • iDRAC.ServiceModule • iDRAC.SmartCard • iDRAC.SNMP • iDRAC.SNMP.Alert • iDRAC.SSH • iDRAC.SupportAssist • iDRAC.SysLog • iDRAC.Telnet • iDRAC.Time • iDRAC.Tuning • iDRAC.Update • iDRAC.USB • iDRAC.UserDomain • iDRAC.Users • iDRAC.vflashpartition • iDRAC.vflashsd • iDRAC.VirtualConsole • iDRAC.VirtualMedia • iDRAC.VNCServer • iDRAC.WebServer • BIOS.BiosBootSettings • BIOS.EmbServerMgmt • BIOS.
• NIC.FCoEConfiguration • NIC.FCoEGenParams • NIC.FrmwImgMenu • NIC.GlobalBandwidthAllocation • NIC.IscsiFirstTgtParams • NIC.IscsiGenParams • NIC.IscsiInitiatorParams • NIC.IscsiSecondaryDeviceParams • NIC.IscsiSecondTgtParams • NIC.NICConfig • NIC.NICPartitioningConfig • NIC.VndrConfigGroup • Storage.Controller • Storage.enclosure • Storage.PhysicalDisk • Storage.VirtualDisk System.Backplane The objects in this group manage the backplane. System.Backplane.
System.ChassisControl.ChassisManagementMonitoring (Read or Write) Table 382. Details of System.ChassisControl.ChassisManagementMonitoring Description Legal Values Enables or disables the event forwarding from CMC. • • 0 — Disabled 1 — Enabled Default value 1 — Enabled Write Privilege Server Control License Required Base Dependency ChassisMangamentAt server object. System.ChassisInfo The objects in this group are applicable only to modular chassis such as Dell PowerEdge M1000e.
System.ChassisInfo.ServiceTag (Read Only) Table 385. Details of System.ChassisInfo.ServiceTag Description Provides the Service Tag of the chassis. Legal Values String of up to 62 ASCII characters Default Value None Write Privilege Not Applicable License Required Not Applicable Dependency None System.OpenIDConnectServer The objects in this group helps in configuration of SSO functionality. System.OpenIDConnectServer.ClientToken (Read or Write) Table 386. Details of System.OpenIDConnectServer.
System.OpenIDConnectServer.DiscoveryURL (Read or Write) Table 388. Details of iSystem.OpenIDConnectServer.DiscoveryURL attribute Description Indicates the discovery URL. Legal Values String of up to 1024 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required RACADM Dependency None System.OpenIDConnectServer.Enabled (Read or Write) Table 389. Details of System.OpenIDConnectServer.Enabled attribute Description Indicates the discovery URL.
System.OpenIDConnectServer.RegistrationDetails(Read or Write) Table 391. Details of System.OpenIDConnectServer.RegistrationDetails attribute Description Indicates the registration details. Legal Values String of up to 1024 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required RACADM Dependency None System.OpenIDConnectServer.RegistrationStatus (Read or Write) Table 392. Details of System.OpenIDConnectServer.
System.QuickSync The objects in this group manage the configuration and recovery of QuickSync settings. System.QuickSync.Access (Read or Write) Table 394. Details of System.QuickSync.Access Description Legal Values Configures the accessibility using Quick Sync on the server. • 0 — Disabled • 1 — Read-only • 2 — Read-write Default Value 2 — Read-write Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency To configure, the System.QuickSync.
Dependency To configure, the System.QuickSync.Presence property must indicate Present System.QuickSync.Presence (Read or Write) Table 397. Details of System.QuickSync.Presence Description Legal Values Indicates the presence of Quick Sync feature in the server. • 0— Not Supported • 1 — Absent • 2 — Present Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None System.
Write Privilege Configure iDRAC and Configure User License Required iDRAC Express or iDRAC Enterprise Dependency None System.LCD.vConsoleIndication (Read or Write) Table 399. Details of System.LCD.vConsoleIndication Description Specifies the virtual console indication. Legal Values • • Default Value Enabled Write Privilege • • License Required iDRAC Express or iDRAC Enterprise Dependency None Enabled Disabled Configure iDRAC Configure User System.LCD.CurrentDisplay (Read Only) Table 400.
Default Value Not Applicable Write Privilege Not Applicable License Required RACADM Dependency None System.LCD.LCDUserString (Read or Write) Table 402. Details of System.LCD.LCDUserString Description Indicates the LCD string set. NOTE: This property is deprecated from version 2.00.00.00. Use the System.LCD.UserDefinedString to perform the operation.
Default Value Watts Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.LCD.UserDefinedString (Read or Write) Table 405. Details of System.LCD.UserDefinedString ( Description Indicates the LCD string set. Legal Values String of up to 62 ASCII characters Default Value 0 Write Privilege Not Applicable License Required Not Applicable Dependency Cannot be configured unless LCD Configuration is user defined. System.
System.Location.DataCenter (Read or Write) Table 407. Details of System.Location.DataCenter Description Indicates name of the data center where the system is located. Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Location.DeviceSize (Read Only) Table 408. Details of System.Location.DeviceSize Description Indicates server chassis size.
System.Location.Rack.Slot (Read or Write) Table 410. Details of System.Location.Rack.Slot Description Indicates the slot where system is located. Legal Values Values: 1–255 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Location.RoomName (Read or Write) Table 411. Details of System.Location.RoomName Description Room name where the system is located.
System.Location.Chassis.Slot (Read or Write) Table 413. Details of System.Location.Chassis.Slot Description Indicates chassis slot. Legal Values Values: 1–255 Default Value Not Applicable Write Privilege Configure iDRAC License Required Not Applicable Dependency None System.OpenIDConnectServer The objects in this group helps in configuration of SSO functionality. System.OpenIDConnectServer.DiscoveryURL (Read or Write) Table 414. Details of iSystem.OpenIDConnectServer.
System.Power.Status (Read Only) Table 415. Details of System.Power.Status Description Represents the device power state, either ON or OFF. Legal Values • 0 — Server is off • 1 — Server is on. Default Value 0 — Server is off Write Privilege Not Applicable License Required Not Applicable Dependency Not Applicable System.Power.ServerAllocation (Read Only) Table 416. Details of System.Power.ServerAllocation Description Indicates the power allocated to running blades.
System.Power.Avg.LastHour (Read Only) Table 418. Details of System.Power.Avg.LastHour Description Displays the average power value during the last hour. Legal Values Values: 1–65535 Default Value Average power value during the last hour. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Avg.LastWeek (Read Only) Table 419. Details of System.Power.Avg.LastWeek Description Indicates the average power value during the last week.
System.Power.Cap.ActivePolicy.Name (Read Only) Table 421. Details of System.Power.Cap.ActivePolicy.Name Description Displays the Active Power Cap Policy Name Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Cap.ActivePolicy.Watts (Read Only) Table 422. Details of System.Power.Cap.ActivePolicy.
Dependency Enable System.Power.Cap.Enable System.Power.Cap. Enable (Read or Write) Table 424. Details of System.Power.Cap. Enable Description Enables or disables user specified power budget threshold configuration. Legal Values • 0 — Disabled • 1 — Enabled Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Cap.MaxThreshold (Read Only) Table 425. Details of System.Power.Cap.
License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Cap.Percent (Read or Write) Table 427. Details of System.Power.Cap.Percent Description Represents the maximum power as a percentage of total power that a server is allowed to consume. To meet this cap, throttle the device. NOTE: This value is applicable only if System.Power.Cap.Enable is set to 1. Legal Values Values: 0–100 Default Value Server power threshold in percentage.
System.Power.Cap.Watts (Read or Write) Table 429. Details of System.Power.Cap.Watts Description Represents the Maximum Power in Watts a device is allowed to consume. To meet this capacity , throttle the device. NOTE: This value is applicable only if System.Power.Cap.Enable is set to 1. Legal Values Values 0–100 Default Value Server power threshold in watts Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Enable System.Power.Cap.Enable System.Power.
Dependency None System.Power.EnergyConsumption.StarttimeStamp (Read Only) Table 432. Details of System.Power.EnergyConsumption.StarttimeStamp Description Displays the Timestamp of the cumulative power consumption. Legal Values String of up to 254 ASCII characters Default Value Timestamp of the cumulative power consumption. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Hotspare.Enable (Read or Write) Table 433. Details of System.
• 2 — PSU2 • 5 — PSU1 and PSU3 • 10 — PSU2 and PSU4 Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.Amps (Read Only) Table 435. Details of System.Power.Max.Amps Description Specifies the device Peak Power Consumption since this value was last cleared. Legal Values Values: 1–65535.
System.Power.Max.Headroom (Read Only) Table 437. Details of System.Power.Max.Headroom Description Displays the difference between the available power and the peak power consumption. NOTE: This object is not applicable on iDRAC on Modular servers. Legal Values Values: 1–65535 Default Value Difference between the available power and the peak power consumption. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.
Dependency None System.Power.Max.LastHour (Read Only) Table 440. Details of System.Power.Max.LastHour Description Displays the maximum power value during the last hour. Legal Values Values: 1–65535 Default Value Maximum power value during the last hour. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.LastHour.TimeStamp (Read Only) Table 441. Details of System.Power.Max.LastHour.
Dependency None System.Power.Max.LastWeek.TimeStamp (Read Only) Table 443. Details of System.Power.Max.LastWeek.TimeStamp Description Displays the timestamp of maximum power value during the last week. Legal Values String of up to 254 ASCII characters Default Value Timestamp of the maximum power value during the last week. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max. Power (Read Only) Table 444. Details of System.Power.Max.
Dependency None System.Power.Max.PowerClear (Read or Write) Table 446. Details of System.Power.Max.PowerClear Description Clears the Maximum Power Consumption timestamps. Legal Values 1 — Clear the Power Consumption Statistics Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Min.LastDay (Read Only) Table 447. Details of System.Power.Min.
Dependency None System.Power.Min.LastHour (Read Only) Table 449. Details of System.Power.Min.LastHour Description Indicates the minimum power value during the last hour. Legal Values Values: 1–65535 Default Value Minimum power value during the last hour. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Min.LastHour.Timestamp (Read Only) Table 450. Details of System.Power.Min.LastHour.
System.Power.Min.LastWeek.TimeStamp (Read Only) Table 452. Details of System.Power.Min.LastWeek.TimeStamp Description Displays the timestamp of minimum power value during the last week. Legal Values String of up to 254 ASCII characters Default Value Timestamp of the minimum power value during the last week. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.PCIeAllocation (Read or Write) Table 453. Details of System.Power.
• 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.RedundancyCapabilities (Read Only) Table 455. Details of System.Power.RedundancyCapabilities Description Returns the redundancy capabilities in the form of a bitmask. This bitmask indicates the values that are set to cfgSensorRedundancyPolicy. NOTE: This object is not applicable for iDRAC on Blade servers.
License Required Not Applicable Dependency Not Applicable System.Power.Supply This group provides information relating to the Power Supplies. This group is indexed from 1 to 4. If there are less than four power supplies on the server, then some of the last indexes of this group are not applicable. This group is applicable for iDRAC on Rack and Tower servers. The following section provides information about the objects in this group. System.Power.Supply.CurrentDraw (Read Only) Table 457.
System.Power.Supply.[i].MaxInputPower (Read Only) Table 459. Details of System.Power.Supply.[i].MaxInputPower Description Displays the AC input rated power in Watts. Legal Values Integer > 0 Default Value 0 Write Privilege Not Applicable License Required Not Applicable Dependency Not Applicable System.Power.Supply.[i].MaxOutputPower (Read Only) Table 460. Details of System.Power.Supply.[i].MaxOutputPower Description Displays the DC output rated power in Watts.
System.Power.Supply.[i].Type (Read Only) Table 462. Details of System.Power.Supply.[i].Type Description Displays whether the power supply is AC or DC. Either of them are indexed group and the square brackets are only place-holders, and do not form a part of command syntax. Legal Values String upto 32 characters. Default None Write Privilege Not Applicable License Required Not Applicable Dependency Not Applicable System.Power.Supply.[i].LineStatus (Read Only) Table 463. Details of System.Power.
System.ServerOS Use the objects in this group to manage the host operating system's name and version details. System.ServerOS.HostName (Read or Write) Table 465. Details of System.ServerOS.HostName Description Displays the host name of the managed server. Legal Values String of up to 256 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.ServerOS.OSName (Read or Write) Table 466.
License Required iDRAC Express or iDRAC Enterprise Dependency None System.ServerOS.ServerPoweredOnTime (Read Only) Table 468. Details of System.ServerOS.ServerPoweredOnTime Description Indicates the time (in seconds) from when the operating system is turned ON. Legal Values Any integer value indicating the system powered on time duration. Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.
System.ThermalSettings.BaseAlgorithm (Read or Write) Table 470. Details of System.ThermalSettings.BaseAlgorithm Description Specifies the thermal base algorithm. NOTE: This object is not applicable for Rack and Tower server. Legal Values • 0 — Auto • 1 — Max Exhaust Temperature • 2 — Min Power Default values None License Required iDRAC Express Dependency None System.ThermalSettings.MinimumFanSpeed (Read or Write) Table 471. Details of System.ThermalSettings.
System.ThermalSettings.FanSpeedLowOffsetVal (Read Only) Table 473. Details of System.ThermalSettings.FanSpeedLowOffsetVal Description Indicates the percentage range for low fan Offset speed. NOTE: This attribute is platform dependent. Legal Values Integral Values: 0 – 100 Default Value 0 License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalSettings.FanSpeedMediumOffsetVal (Read Only) Table 474. Details of System.ThermalSettings.
System.ThermalSettings.FanSpeedMaxOffsetVal (Read Only) Table 476. Details of System.ThermalSettings.FanSpeedMaxOffsetVal Description Indicates the percentage range for low fan offset speed. NOTE: This attribute is platform dependent. Legal Values Integral Values: 0 – 100 Default Value 0 License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalSettings.MFSMinimumLimit (Read Only) Table 477. Details of System.ThermalSettings.
System.ThermalSettings.ThermalProfile (Read or Write) Table 479. Details of System.ThermalSettings.ThermalProfile Description Sets the thermal base algorithm. NOTE: Restart the system to activate the power and thermal settings. Legal Values • 0 — Default Thermal Profile Settings • 1 — Maximum performance • 2 — Minimum Power Default Value Auto Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None tails ofSystem.ThermalSettings.
System.ThermalConfig.CriticalEventGenerationInterval (Read or Write) Table 481. Details of System.ThermalConfig.CriticalEventGenerationInterval Description Indicates the time interval (in days) for critical events to be generated. Legal Values Integral Values: 0-365 Default Value 30 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalConfig.EventGenerationInterval (Read or Write) Table 482. Details of System.ThermalConfig.
LifecycleController.LCAttributes The following section provides information about the objects in the LifecycleController.LCAttributes group. NOTE: A job successfully configured using the autoupdate or autobackup feature settings can be deleted only if the job is currently not running or downloading. LifecycleController.LCAttributes.autobackup (Read or Write) Table 484. Details of LifecycleController.LCAttributes.autobackup Description Legal Values Enables or disables the automatic backup scheduler.
License Required iDRAC Enterprise Dependency None LifecycleController.LCAttributes.BiosRTDRequested (Read or Write) Table 487. Details of LifecycleController.LCAttributes.BiosRTDRequested Description Reset all the BIOS attributes to the default state. Set the value to 1, and restart the server to reset the BIOS attributes to factory default. After the server restart, the value is set to 0 by default.
LifecycleController.LCAttributes.DiscoveryFactoryDefaults (Read Only) Table 489. Details of LifecycleController.LCAttributes.DiscoveryFactoryDefaults Description Legal Values Enables or disables the discovery factory defaults. • 0 — Off • 1 — On Default Value 0 — Off Write Privilege Not Applicable License Required iDRAC Enterprise Dependency None LifecycleController.LCAttributes.IPChangeNotifyPS (Read or Write) Table 490. Details of LifecycleController.LCAttributes.
LifecycleController.LCAttributes.LifecycleControllerState (Read or Write) Table 492. Details of LifecycleController.LCAttributes.LifecycleControllerState Description Legal Values Enables or disables lifecycle controller. • 0 — Disabled • 1 — Enabled • 2 — Recovery (Read Only Value) Default Value 1 — Enabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None LifecycleController.LCAttributes.ProvisioningServer (Read or Write) Table 493.
Default Value 0 — Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None LifecycleController.LCAttributes.PartFirmwareUpdate (Read or Write) Table 495. Details of LifecycleController.LCAttributes.PartFirmwareUpdate Description Apply firmware changes to the replaced part on part replacement.
LifecycleController.LCAttributes.VirtualAddressManagementAp plication (Read or Write) Table 497. Details of Description Specifies the console name of Virtual Address Management Application. Legal Values String of up to 32 ACSII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory To manage the configuration of the iDRAC Active Directory features, use the objects in this group. iDRAC.ActiveDirectory.
Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.DCLookupByUserDomain (Read or Write) Table 500. Details of iDRAC.ActiveDirectory.DCLookupByUserDomain Description To look up the user domain for Active Directory, enables the selection option.
iDRAC.ActiveDirectory.DCLookupEnable (Read or Write) Table 502. Details of iDRAC.ActiveDirectory.DCLookupEnable Description Configures iDRAC to use preconfigured domain controllers or to use DNS to find the domain controller Legal Values • 0 — Disabled • 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency Cannot be enabled unless one of the following is configured: • IPv4.DNS1 • IPv4.DNS2 • IPv6.DNS1 • IPv6.DNS2 iDRAC.
Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.DomainController3 (Read or Write) Table 505. Details of iDRAC.ActiveDirectory.DomainController3 Description FQDN that stores the address of the active directory domain controller 3 Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.
• 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency Cannot be enabled unless one of the following is configured: • IPv4.DNS1 • IPv4.DNS2 • IPv6.DNS1 • IPv6.DNS2 iDRAC.ActiveDirectory.GCRootDomain (Read or Write) Table 508. Details of iDRAC.ActiveDirectory.GCRootDomain Description The names of the Active Directory root domain used for DNS look up.
iDRAC.ActiveDirectory.GlobalCatalog2 (Read or Write) Table 510. Details of iDRAC.ActiveDirectory.GlobalCatalog2 Description To obtain user names, specifies the Global Catalog server from which you want the iDRAC. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.GlobalCatalog3 (Read or Write) Table 511. Details of iDRAC.ActiveDirectory.
iDRAC.ActiveDirectory.RacName (Read or Write) Table 513. Details of iDRAC.ActiveDirectory.RacName Description Name of iDRAC as recorded in the Active Directory forest. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.Schema (Read or Write) Table 514. Details of iDRAC.ActiveDirectory.Schema Description To use with Active Directory, determine the schema type.
License Required iDRAC Enterprise Dependency Cannot be enabled unless SmartCard Logon Enable is disabled. iDRAC.ADGroup To manage the configuration of AD standard schema settings, use these objects in the group. This group is indexed from 1 to 5. iDRAC.ADGroup.Domain (Read or Write) Table 516. Details of iDRAC.ADGroup.Domain Description Active Directory Domain in which the Role Group resides.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.AutoOSLock To manage the OS Auto lock feature, use these objects in this group. iDRAC.AutoOSLock.AutoOSLockState (Read or Write) Table 519. Details of iDRAC.AutoOSLock.AutoOSLockState Description Enable or Disable OS Auto lock feature.
iDRAC.EmailAlert.CustomMsg (Read or Write) Table 521. Details of iDRAC.EmailAlert.CustomMsg Description Specifies the custom message that forms the subject of the alert. Legal Values A string of up to 32 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.EmailAlert.Enable (Read or Write) Table 522. Details of iDRAC.EmailAlert.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Info.Description (Read or Write) Table 524. Details of iDRAC.Info.Description Description Text description of the iDRAC. Legal Values String of up to 255 ASCII characters Default Value The system component provides a set of remote management operations for Dell PowerEdge Servers. Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Info.Type (Read or Write) Table 527. Details of iDRAC.Info.Type Description Identifies the remote access controller type Legal Values • • Default Vlaue 12G Monolithic Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None 16 (12G iDRAC Monolithic) 17 (12G iDRAC Modular) iDRAC.Info.Version (Read Only) Table 528. Details of iDRAC.Info.
Dependency None iDRAC.IOIDOpt The objects in this group manage the IOIDOpt attributes. iDRAC.IOIDOptEnable (Read or Write) Table 530. Details of iDRAC.IOIDOptEnable Description Legal Values Enables or disables Identity Optimization (IO). • 0 — Disabled • 1 — Enabled Default values 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IOIDOpt.InitiatorPersistencePolicy (Read or Write) Table 531. Details of iDRAC.IOIDOpt.
iDRAC.IOIDOpt.StorageTargetPersistencePolicy (Read or Write) Table 532. Details of iDRAC.IOIDOpt.StorageTargetPersistencePolicy Description Legal Values Sets the Virtual Address Management StorageTargetPersistencePolicy.
iDRAC.IOIDOpt.VirtualAddressPersistencePolicyNonAuxPwrd (Read or Write) Table 534. Details of iDRAC.IOIDOpt.VirtualAddressPersistencePolicyNonAuxPwrd Description Legal Values Applied for the Non-Aux powered devices, which persist the virtual address on warm reset.
iDRAC.IPBlocking.FailCount (Read or Write) Table 536. Details of iDRAC.IPBlocking.FailCount Description The maximum number of logins that are unsuccessful to occur within the window before logs in attempts from the IP address are rejected. Legal Values Integral values: 2–16 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPBlocking.FailWindow (Read or Write) Table 537. Details of iDRAC.IPBlocking.
iDRAC.IPBlocking.RangeAddr (Read or Write) Table 539. Details of iDRAC.IPBlocking.RangeAddr Description Specifies the acceptable IPv4 address bit pattern in positions determined by the 1s in the range mask. Legal Values Valid IPv4 Address Default Value 192.168.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPBlocking.RangeEnable (Read or Write) Table 540. Details of iDRAC.IPBlocking.
Dependency None iDRAC.IPMILan To configure IPMI over LAN of the system, use the objects in this group. iDRAC.IPMILan.AlertEnable (Read or Write) Table 542. Details of iDRAC.IPMILan.AlertEnable Description Legal Values Enables or disables global email alerting. • 0 — Disabled • 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMILan.CommunityName (Read or Write) Table 543. Details of iDRAC.IPMILan.
• 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMILan.EncryptionKey (Read or Write) Table 545. Details of iDRAC.IPMILan.EncryptionKey Description Enables or disables the IPMI over LAN interface.
NOTE: This is supported only for rack and tower systems. iDRAC.IPMISerial.BaudRate (Read or Write) Table 547. Details of iDRAC.IPMISerial.BaudRate Description Specifies the baud rate for serial connection over IPMI. Legal Values • • • • Default Value 115200 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None 9600 19200 57600 115200 iDRAC.IPMISerial.ChanPrivLimit (Read or Write) Table 548. Details of iDRAC.IPMISerial.
• 0 — Terminal Default Value 1 — Basic Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.DeleteControl (Read or Write) Table 550. Details of iDRAC.IPMISerial.DeleteControl Description Enables or disables delete control on the IPMI serial interface.
iDRAC.IPMISerial.FlowControl (Read or Write) Table 552. Details of iDRAC.IPMISerial.FlowControl Description Specifies the Flow Control setting for IPMI serial port. Legal Values • 0 — None • 2 — RTS or CTS Default Value 2 — RTS or CTS Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.HandshakeControl (Read or Write) Table 553. Details of iDRAC.IPMISerial.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.LineEdit (Read or Write) Table 555. Details of iDRAC.IPMISerial.LineEdit Description Enables or disables line editing on the IPMI serial interface. Legal Values • 0 — Disabled • 1 — Enabled Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.NewLineSeq (Read or Write) Table 556.
iDRAC.IPMISOL.AccumulateInterval (Read or Write) Table 557. Details of iDRAC.IPMISOL.AccumulateInterval Description Specifies the typical amount of time that iDRAC waits before transmitting a partial SOL character data packet. Legal Values Integral values: 1–255 Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISOL.BaudRate (Read or Write) Table 558. Details of iDRAC.IPMISOL.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISOL.MinPrivilege (Read or Write) Table 560. Details of iDRAC.IPMISOL.MinPrivilege Description Legal Values Specifies the minimum privilege level required for serial access. • 2—User • 3—Operator • 4—Administrator Default Value 4—Administrator Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISOL.
iDRAC.IPv4.Address (Read or Write) Table 562. Details of iDRAC.IPv4.Address Description The current IPv4 address assigned to iDRAC. Legal Values Valid IPv4 Address ` Default Value 192.168.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv4.DHCPEnable is disabled. iDRAC.IPv4.DHCPEnable (Read or Write) Table 563. Details of iDRAC.IPv4.DHCPEnable Description Specifies if DHCP is used to assign the iDRAC IPv4 address.
License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv4.DNSFromDHCP is disabled. iDRAC.IPv4.DNS2 (Read or Write) Table 565. Details of iDRAC.IPv4.DNS2 Description IPv4 address for DNS Server 2. Legal Values Valid IPv4 Address Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv4.DNSFromDHCP is disabled. iDRAC.IPv4.DNSFromDHCP (Read or Write) Table 566. Details of iDRAC.
Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv4.Gateway (Read or Write) Table 568. Details of iDRAC.IPv4.Gateway Description The gateway for the iDRAC IPv4 address. Legal Values Valid IPv4 gateway Default Value 192.168.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv4.DHCPEnable is disabled. iDRAC.IPv4.
iDRAC.IPv4Static.Address (Read or Write) Table 570. Details of iDRAC.IPv4Static.Address attribute Description iDRAC static IPv4 address. This address can be configured even when DHCP is enabled. Legal Values Valid IPv4 Address Default Value 192.168.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv4Static.DNS1 (Read or Write) Table 571. Details of iDRAC.IPv4Static.DNS1 Description Statically configurable DNS Server 1.
iDRAC.IPv4Static.DNSFromDHCP (Read or Write) Table 573. Details of iDRAC.IPv4Static.DNSFromDHCP Description Legal Values Specifies if the DNS server IPv4 addresses should be assigned from the DHCP server on the network. • 0 — Disabled • 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv4Static.Gateway (Read or Write) Table 574. Details of iDRAC.IPv4Static.
iDRAC.IPv6 To manage the IPv6 configuration properties of iDRAC, use the objects in this group. iDRAC.IPv6.Address 1 (Read or Write) Table 576. Details of iDRAC.IPv6.Address 1 attribute Description iDRAC IPv6 Address. Legal Values Valid IPv6 Address Default Value Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv6.AutoConfig is disabled. iDRAC.IPv6.Address 2 (Read or Write) Table 577. Details of iDRAC.IPv6.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address 4 (Read or Write) Table 579. Details of iDRAC.IPv6.Address 4 attribute Description iDRAC IPv6 fourth address. Legal Values Valid IPv6 Address Default Value Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address 5 (Read or Write) Table 580. Details of iDRAC.IPv6.Address 5 attribute Description iDRAC IPv6 fifth address.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address 7 (Read or Write) Table 582. Details of iDRAC.IPv6.Address 7 attribute Description iDRAC IPv6 seventh address. Legal Values Valid IPv6 Address Default Value Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address 8 (Read or Write) Table 583. Details of iDRAC.IPv6.Address 8 attribute Description iDRAC IPv6 eighth address.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address10 (Read or Write) Table 585. Details of iDRAC.IPv6.Address10 attribute Description iDRAC IPv6 tenth address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address11 (Read or Write) Table 586. Details of iDRAC.IPv6.Address11 attribute Description iDRAC IPv6 eleventh address.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address13 (Read or Write) Table 588. Details of iDRAC.IPv6.Address13 attribute Description iDRAC IPv6 thirteenth address. Legal Values Valid IPv6 Address Default Value Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address14 (Read or Write) Table 589. Details of iDRAC.IPv6.Address14 attribute Description iDRAC IPv6 fourteenth address.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.AutoConfig (Read or Write) Table 591. Details of iDRAC.IPv6.AutoConfig attribute Description Enables or disables the iDRAC IPv6 auto configuration option. Legal Values • 0 — Disabled • 1 — Enabled Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.DNS1 (Read or Write) Table 592. Details of iDRAC.IPv6.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv6.DNSFromDHCP6 is disabled. iDRAC.IPv6.DNSFromDHCP6 (Read or Write) Table 594. Details of iDRAC.IPv6.DNSFromDHCP6 attribute Description Specifies if the DNS Server addresses are obtained from DHCP or not.
iDRAC.IPv6.Gateway (Read or Write) Table 596. Details of iDRAC.IPv6.Gateway attribute Description iDRAC IPv6 Gateway Legal Values Valid IPv6 gateway Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv6.AutoConfig is disabled. iDRAC.IPv6.LinkLocalAddress (Read or Write) Table 597. Details of iDRAC.IPv6.LinkLocalAddress attribute Description iDRAC IPv6 Link Local Address.
iDRAC.IPv6Static To manage the IPv6 static configuration properties of iDRAC, use the objects in this group iDRAC.IPv6Static.Address1 (Read or Write) Table 599. Details of iDRAC.IPv6Static.Address1 attribute Description iDRAC static IPv6 address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6Static.DNS1 (Read or Write) Table 600. Details of iDRAC.IPv6Static.
iDRAC.IPv6Static.DNSFromDHCP6 (Read or Write) Table 602. Details of iDRAC.IPv6Static.DNSFromDHCP6 attribute Description Specifies if the DNS server IPv6 addresses must be assigned from the DHCP server on the network. Legal Values • 0 — Disabled • 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6Static.Gateway (Read or Write) Table 603. Details of iDRAC.IPv6Static.
iDRAC.IPv6URL Use the objects in this group to manage the IPv6 static configuration properties of iDRAC. iDRAC.IPv6URL.URL (Read Only) Table 605. Details of iDRAC.IPv6URL.URL attribute Description iDRAC IPv6 URL String of format 'https://[ipv6 address]:' Legal Values IPv6 URL String Default Value Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency iDRAC IPv6 has to be Enabled iDRAC.
Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LDAP.BindPassword (Write Only) Table 608. Details of iDRAC.LDAP.BindPassword attribute Description A bind password to use along with the bindDN. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LDAP.CertValidationEnable (Read or Write) Table 609.
iDRAC.LDAP.Enable (Read or Write) Table 610. Details of iDRAC.LDAP.Enable attribute Description Turns LDAP service on or off. Legal Values • 0 — Disabled • 1 — Enabled Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LDAP.GroupAttribute (Read or Write) Table 611. Details of iDRAC.LDAP.GroupAttribute attribute Description Specifies which LDAP attribute is used to check for group membership.
License Required iDRAC Enterprise Dependency None iDRAC.LDAP.Port (Read or Write) Table 613. Details of iDRAC.LDAP.Port attribute Description Port of LDAP over SSL. Legal Values Integer values: 1–65535 Default Value 636 Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LDAP.SearchFilter (Read or Write) Table 614. Details of iDRAC.LDAP.
License Required iDRAC Enterprise Dependency None iDRAC.LDAP.UserAttribute (Read or Write) Table 616. Details of iDRAC.LDAP.UserAttribute attribute Description To search, specify the user attribute. Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LDAPRoleGroup The objects in this group enable configuration of role groups for LDAP. This group is indexed from 1 to 5. iDRAC.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LocalSecurity To manage the ability to configure iDRAC, use the objects in this group. iDRAC.LocalSecurity.LocalConfigDisabled (Read or Write) Table 619. Details of iDRAC.LocalSecurity.LocalConfigDisabled attribute Description To configure iDRAC from Local RACADM, enable or disable the ability of the local user.
iDRAC.Logging iDRAC. Logging Manages the ability to configure iDRAC iDRAC.Logging.SELOEMEventFilterEnable (Read or Write) Table 621. Details of iDRAC.Logging.SELOEMEventFilterEnable attribute Description Enables or disables the ability of Logging SEL Records with OEM. Legal Values • 0 — Disabled • 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.
• 2 — Enable Once After Reset NOTE: Configures after iDRAC reset. Default Values 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.NIC.AutoDetect (Read or Write) Table 623. Details of iDRAC.NIC.AutoDetect attribute Description Enables or disables auto detection feature of iDRAC.
iDRAC.NIC.DedicatedNICScanTime (Read or Write) Table 625. Details of iDRAC.NIC.DedicatedNICScanTime attribute Description Wait time for the iDRAC to switch from dedicated mode to shared mode. Legal Values Integral values: 5–255 Default Value 5 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.DNSDomainFromDHCP (Read or Write) Table 626. Details of iDRAC.NIC.
License Required iDRAC Express or iDRAC Enterprise Dependency Can be set only if NIC.DNSDomainFromDHCP is disabled. iDRAC.NIC.DNSDomainNameFromDHCP (Read or Write) Table 628. Details of DRAC.NIC.DNSDomainNameFromDHCP attribute Description Specifies that the iDRAC DNS domain name must be assigned from the network DHCP server.
Default value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Can be Enabled only if DNSRacName is set. iDRAC.NIC.Duplex (Read or Write) Table 631. Details of iDRAC.NIC.Duplex attribute Description Specifies the duplex setting for the iDRAC NIC. Legal Values • 0 — Half • 1 — Full Default value 1 — Full Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.
iDRAC.NIC.Failover (Read or Write) Table 633. Details of iDRAC.NIC.Failover attribute Description Enables or disables failover for iDRAC to switch from shared to dedicated. Legal Values • 0 — None • 2 — LOM1 • 3 — LOM2 • 4 — LOM3 • 5 — LOM4 • 6 — All Default Value 0 — None Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Possible Values depend on current NICSelection settings. iDRAC.NIC.MACAddress (Read or Write) Table 634.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.Selection (Read or Write) Table 636. Details of iDRAC.NIC.Selection attribute Description Specifies the current mode of operation for the iDRAC network interface controller.
iDRAC.NIC.Speed (Read or Write) Table 638. Details of iDRAC.NIC.Speed attribute Description Specifies the speed for iDRAC NIC. NOTE: To set this property: Legal Values • iDRAC.NIC.Selection must be set to Dedicated mode. • iDRAC.NIC.Autoneg must be disabled. • iDRAC.IPv4.Enable, iDRAC.IPv4.DHCPEnable, iDRAC.IPv6.Enable, and iDRAC.IPv6.AutoConfig must be enabled. • 0 — 10 • 1 — 100 • 2 — 1000 NOTE: You cannot manually set the Network Speed to 1000 MB. This option is available only if iDRAC.NIC.
iDRAC.NIC.VLanEnable (Read Only) Table 640. Details of iDRAC.NIC.VLanEnable attribute Description Enables or disables the VLAN capabilities of the iDRAC. NOTE: This object is applicable only to iDRAC on Racks and Towers. Legal Values • 0 — Disabled • 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.VLanID (Read Only) Table 641. Details of iDRAC.NIC.
Default Value 0 — Both Write Privilege Configure iDRAC License Required RACADM Dependency None iDRAC.NIC.VLanPriority (Read Only) Table 643. Details of iDRAC.NIC.VLanPriority attribute Description Specifies the VLAN priority for the network VLAN configuration. NOTE: This object is applicable only to iDRAC on Racks and Towers. Legal Values Integral values: 0–7 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.
iDRAC.NICStatic.DNSDomainName (Read or Write) Table 645. Details of iDRAC.NICStatic.DNSDomainName attribute Description The DNS Domain Name. Legal Values • 0 — Disabled • 1 — Enabled Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NTPConfigGroup To configure the properties of NTP server, use the objects in this group. iDRAC.NTPConfigGroup.NTP1 (Read or Write) Table 646. Details of iDRAC.NTPConfigGroup.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NTPConfigGroup.NTP3 (Read or Write) Table 648. Details of iDRAC.NTPConfigGroup.NTP3 attribute Description Configure NTP Server 3 Address. Legal Values String of up to 254 ASCII characters. Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NTPConfigGroup.NTPEnable (Read or Write) Table 649.
iDRAC.NTPConfigGroup.NTPMaxDist (Read or Write) Table 650. Details of iDRAC.NTPConfigGroup.NTPMaxDist attribute Description NTP Maximum Distance Legal Values Integral values: 1–128 Default Value 16 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.OS-BMC To manage OS-BMC pass-through feature, use the object in this group. iDRAC.OS-BMC.AdminState (Read or Write) Table 651. Details of iDRAC.OS-BMC.
Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.OS-BMC.PTCapability (Read or Write) Table 653. Details of iDRAC.OS-BMC.PTCapability Description Operating System to iDRAC Pass Through Capability status. Legal Values • 0 — Capable • 1 — Not Capable or Unknown Default Value Depends on the server capability.
iDRAC.OS-BMC.UsbNicIpAddress (Read or Write) Table 655. Details of iDRAC.OS-BMC.UsbNicIpAddress Description Displays the USB NIC IP address. Legal Values Valid IPv4 address Default Value 169.168.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Racadm To manage Remote RACADM connection settings, use the object in this group. iDRAC.Racadm.Enable (Read or Write) Table 656. Details of iDRAC.Racadm.
Default Value 60 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Redfish The objects in this group provide configuration parameters for the Redfish interface to iDRAC. iDRAC.Redfish.Enable (Read or Write) Table 658. Details of iDRAC.Redfish.Enable Description Enables or disables Redfish service on iDRAC.
Dependency None iDRAC.Redfisheventing.DeliveryRetryIntervalInSeconds (Read or Write) Table 660. Details of iDRAC.Redfisheventing.DeliveryRetryIntervalInSeconds Description Specifies the intervals (in seconds) of retry attempts made for Redfish event delivery. Legal Values Value ranges from 5 to 60. Default Value 30 Write Privilege Configure iDRAC License Required RACADM Dependency None iDRAC.Redfisheventing.IgnoreCertificateErrors (Read Only) Table 661. Details of iDRAC.Redfisheventing.
Default Value 25 Write Privilege Configure iDRAC License Required iDRAC Express Dependency None iDRAC.RemoteHosts.SMTPServerIPAddress (Read or Write) Table 663. Details of iDRAC.RemoteHosts.SMTPServerIPAddress Description IPv4 or IPv6 address of the network SMTP server. Legal Values String representing a valid SMTP server IPv4 or IPv6 address Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.
iDRAC.RFS.MediaAttachState (Read Only) Table 665. Details of iDRAC.RFS.MediaAttachState Description RFS Media attach state. Legal Values • 0 — Attached • 1 — Detached Default Value 1 — Detached Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.RSM The objects in this group manage the Rack Style Management (RSM) settings. iDRAC.RSM.RSMCapability (Read Only) Table 666. Details of iDRAC.RSM.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Security Use the objects in this group to configure SSL certificate signing request settings. For the country code, see http://www.iso.org/iso/home/standards/country_codes.htm. iDRAC.Security.CsrCommonName (Read or Write) Table 668. Details of iDRAC.Security.CsrCommonName Description Specifies the CSR Common Name (CN) that must be an IP as given in the certificate.
iDRAC.Security.CsrEmailAddr (Read or Write) Table 670. Details of iDRAC.Security.CsrEmailAddr Description Specifies the CSR email address. Legal Values Valid email address string of up to 254 ASCII characters. Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Security.CsrKeySize (Read or Write) Table 671. Details of iDRAC.Security.CsrKeySize Description Specifies the SSL asymmetric key size for the CSRs.
Dependency None iDRAC.Security.CsrOrganizationName (Read or Write) Table 673. Details of iDRAC.Security.CsrOrganizationName Description Specifies the CSR Organization Name (O). Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Security.CsrOrganizationUnit (Read or Write) Table 674. Details of iDRAC.Security.
Dependency None iDRAC.Security.CsrSubjectAltName (Read or Write) Table 676. Details of iDRAC.Security.CsrSubjectAltName attribute Description Specifies the CSR subject alternative name. Legal Values String of up to 1024 ASCII characters NOTE: In the RACADM autocomplete mode, the string value up to 512 characters are supported. If the value length is 512 and more, execute this command in the normal execution mode.
iDRAC.Serial.BaudRate (Read or Write) Table 678. Details of iDRAC.Serial.BaudRate Description Sets the Baud rate on the iDRAC serial port. Legal Values • • • • Default Value 115200 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None 9600 19200 57600 115200 iDRAC.Serial.Command (Read or Write) Table 679. Details of iDRAC.Serial.Command Description Specifies a serial command that is executed after the user logs in to the serial console interface.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Serial.HistorySize (Read or Write) Table 681. Details of iDRAC.Serial.HistorySize Description Specifies the maximum size of the serial history buffer. Legal Values Integral values from 0 to 8192. Default Value 8192 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Serial.IdleTimeout (Read or Write) Table 682. Details of iDRAC.
• 1 — Enabled Default Value Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.SerialRedirection The objects in this group manage Serial Redirection properties of iDRAC. NOTE: It supports only rack and tower systems. iDRAC.SerialRedirection.Enable (Read or Write) Table 684. Details of iDRAC.SerialRedirection.Enable Description Enables or disables the console for COM2 port redirection.
iDRAC.serverboot The objects in this group manages the server boot options. iDRAC.serverboot.BootOnce (Read or Write) Table 686. Details of iDRAC.serverboot.BootOnce Description Legal Values Enables or disables BootOnce option for the configured device. • 0 — Disabled • 1 — Enabled Default values 1 — Enabled Write Privilege Login and configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Read only if iDRAC.ServerBoot.
iDRAC.ServiceModule The objects in this group manages the properties of the ISM modules. iDRAC.ServiceModule.HostSNMPGet (Read or Write) Table 688. Details of iDRAC.ServiceModule.HostSNMPGet attribute Description Enables or disables SNMP get using host OS. Legal Values • • Default Value 0 - Disabled Write Privilege Not Applicable License Required RACADM Dependency None 0 - Disabled 1 - Enabled iDRAC.ServiceModule.HostSNMPGet Table 689. Details of iDRAC.ServiceModule.
Write Privilege Configure iDRAC License Required RACADM Dependency iDRAC.ServiceModule.ServiceModuleEnable attribute must be enabled. iDRAC.ServiceModule.LCLReplication (Read or Write) Table 691. Details of iDRAC.ServiceModule.LCLReplication Description Legal Values Enables Lifecycle log in operating system log Baud rate on the iDRAC serial port.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.ServiceModule.ServiceModuleEnable (Read or Write) Table 694. Details of iDRAC.ServiceModule.ServiceModuleEnable Description Legal Values Disables the Service Module process on host operating system. • 0 — Disabled • 1 — Enabled Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.ServiceModule.ServiceModuleState (Read or Write) Table 695.
iDRAC.ServiceModule.WatchdogRecoveryAction (Read and Write) Table 697. Details of iDRAC.ServiceModule.WatchdogRecoveryAction Description Legal Values Configures recovery action on watchdog alert. • 0 — None • 1 — Reboot • 2 — Poweroff • 3 — Powercycle Default Value 0 — None Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency If the iDRAC.ServiceModule.WatchdogState object is 'Disabled', then the value cannot be set. iDRAC.ServiceModule.
iDRAC.SmartCard The objects in this group enable you to access iDRAC using a smart card. iDRAC.SmartCard.SmartCardCRLEnable (Read or Write) Table 700. Details of iDRAC.SmartCard.SmartCardCRLEnable Description Enables or disables the Certificate Revocation List (CRL). Legal Values • 0 — Disabled • 1 — Enabled Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency To log on, enable Smart Card. iDRAC.SmartCard.
iDRAC.SNMP.AgentCommunity (Read or Write) Table 702. Details of iDRAC.SNMP.AgentCommunity Description Specifies the SNMP community name to be used for SNMP Agent Legal Values String of up to 31 ACSII characters Default value Public Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.SNMP.AgentEnable (Read or Write) Table 703. Details of iDRAC.SNMP.AgentEnable Description Enables or disables the SNMP Agent on the iDRAC.
iDRAC.SNMP.DiscoveryPort (Read or Write) Table 705. Details of iDRAC.SNMP.DiscoveryPort Description Specifies the SNMP agent port on iDRAC. Legal Values Integral values: 1–65535 Default Value 161 Write Privilege Configure iDRAC License Required iDRAC Express Dependency None iDRAC.SNMP.SNMPProtocol (Read or Write) Table 706. Details of iDRAC.SNMP.SNMPProtocol Description Specifies the SNMP protocol.
Dependency None iDRAC.SNMP.Alert The objects in this group configures the SNMP alert settings. This group is indexed from 1 to 8. iDRAC.SNMP.Alert.DestAddr (Read or Write) Table 708. Details of iDRAC.SNMP.Alert.DestAddr Description IPv4, IPv6 or FQDN address of the target destination to receive alters. Legal Values Valid IPv4 or IPv6 or FQDN address Default Value • • Write Privilege Configure iDRAC License Required None Dependency None Index 1–4 — 0.0.0.0 Index 5–8 — :: iDRAC.SNMP.Alert.
iDRAC.SNMP.Alert.SNMPv3UserID (Read Only) Table 710. Details of iDRAC.SNMP.Alert.SNMPv3UserID Description Indicates the index of the user to which this alert is configured. Legal Values Integral values: 2–16 Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express Dependency None iDRAC.SNMP.Alert.SNMPv3Username (Read or Write) Table 711. Details of iDRAC.SNMP.Alert.SNMPv3Username Description Specifies the SNMP v3 user name for the given index.
iDRAC.SSH.Port (Read or Write) Table 713. Details of iDRAC.SSH.Port Description Specifies the port number for the iDRAC SSH interface. Legal Values Integral values: 1–65535 Default Value 22 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.SSH.Timeout (Read or Write) Table 714. Details of iDRAC.SSH.Timeout Description Defines the secure shell idle timeout.
License Required RACADM Dependency HostOSProxyConfigured should be 1 - Yes iDRAC.SupportAssist.HostOSProxyConfigured Table 716. Details of iDRAC.SupportAssist.HostOSProxyConfigured Description Indicates whether Host OS uses proxy configuration to connect to Internet. Legal Values 0-No 1-Yes Default Value 0-No License Required RACADM Dependency None iDRAC.SupportAssist.HostOSProxyPassword Table 717. Details of iDRAC.SupportAssist.HostOSProxyPassword Description Host OS proxy password.
iDRAC.SupportAssist.HostOSProxyUserName Table 719. Details of iDRAC.SupportAssist.HostOSProxyUserName Description Host OS proxy password. Legal Values String of 0 to 64 characters length Default Value NA License Required RACADM Dependency HostOSProxyConfigured should be Yes-1 iDRAC.SysLog The objects in this group provide the properties for configuration of the SMTP server. iDRAC.SysLog.Port (Read or Write) Table 720. Details of iDRAC.SysLog.Port Description Remote syslog port number.
Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.SysLog.PowerLogInterval (Read or Write) Table 722. Details of iDRAC.SysLog.PowerLogInterval Description Configure time delay for power logging. Legal Values Integral values: 1–1440 Default Value 5 Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.SysLog.Server1 (Read or Write) Table 723. Details of iDRAC.SysLog.Server1 Description Name of remote syslog server 1.
Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.SysLog.Server3 (Read or Write) Table 725. Details of iDRAC.SysLog.Server3 Description Name of remote syslog server 3. Legal Values String of up to 63 ACSII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.SysLog.SysLogEnable (Read or Write) Table 726. Details of iDRAC.SysLog.
iDRAC.Telnet.Enable (Read or Write) Table 727. Details of iDRAC.Telnet.Enable Description Enables or disables Telnet. Legal Values • 0 — Disabled • 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Telnet.Port (Read or Write) Table 728. Details of iDRAC.Telnet.Port Description Specifies the port number for the iDRAC Telnet interface.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Time.Timezone (Read or Write) Table 730. Details of iDRAC.Time.Timezone Description Configure the time zone. Legal Values Valid time zone string of up to 32 ASCII characters For example: US/Central Default Value CST6CDT Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Time.TimeZoneOffset (Read or Write) Table 731. Details of iDRAC.Time.
Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Update The objects in this group enable you to manage configuration parameters for iDRAC firmware update. NOTE: fwUpdateIPAddr attribute is applicable for Monolithic & FX2/FX2s only. iDRAC.Update.FwUpdateIPAddr (Read or Write) Table 733. Details of iDRAC.Update.FwUpdateIPAddr Description Specifies the TFTP server address to be used for iDRAC firmware update operations.
iDRAC.Update.FwUpdateTFTPEnable (Read or Write) Table 735. Details of iDRAC.Update.FwUpdateTFTPEnable Description Enables or disables iDRAC firmware updates from a TFTP server. Legal Values • 0 — Disabled • 1 — Enabled Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.USB The objects in this group manages the front panel USB. iDRAC.USB.ConfigurationXML (Read or Write) Table 736. Details of iDRAC.USB.
• iDRAC Direct Only Default Value Automatic Write Privilege Not Applicable License Required iDRAC Express and iDRAC Enterprise Dependency Not Applicable iDRAC.Telnet.Timeout (Read or Write) Table 738. Details of iDRAC.Telnet.Timeout attribute Description Defines the Telnet idle timeout. Legal Values Integral values: 0–10800 Default Value 1800 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.
iDRAC.Users.Enable (Read or Write) Table 740. Details of iDRAC.Users.Enable attribute Description Enables or disables an individual user. Legal Values • 0 — Disabled • 1 — Enabled Default Value 0 — Disabled. However, Root user is Enabled. Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Both username and password must be configured prior to enabling the user. iDRAC.Users.IpmiLanPrivilege (Read or Write) Table 741. Details of iDRAC.Users.
• 3 — Operator • 4 — Administrator • 15 — No access Default Value 15 — No access Write Privilege Configure iDRAC and user License Required iDRAC Express or iDRAC Enterprise Dependency Both username and password must be configured prior to setting this object. iDRAC.Users.MD5v3Key (Read or Write) Table 743. Details of iDRAC.Users.MD5v3Key attribute Description Indicates the MD5 Hash of the SNMP V3 key.
Default Value Not Applicable Write Privilege Configure iDRAC and Configure User License Required iDRAC Express Dependency User name must be configured prior to setting this object. iDRAC.Users.SHA256PasswordSalt (Read or Write) Table 746. Details of iDRAC.Users.SHA256PasswordSalt attribute Description Indicates the Salt string added to password before hash.
iDRAC.Users.SNMPv3AuthenticationType (Read or Write) Table 749. Details of iDRAC.Users.SNMPv3AuthenticationType attribute Description Configure SNMPv3 authentication protocol type. Legal Values • 0 — None • 1 — MD5 • 2 — SHA Default Value 2 — SHA Write Privilege Configure iDRAC and Configure User License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Users.SNMPv3Enable (Read or Write) Table 750. Details of iDRAC.Users.
Default Value 2 — AES Write Privilege Configure iDRAC and Configure User License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Users.SolEnable (Read or Write) Table 752. Details of iDRAC.Users.SolEnable attribute Description Enables or Disables SOL for the user.
iDRAC.vflashpartition.AccessType (Read or Write) Table 754. Details of iDRAC.vflashpartition.AccessType attribute Description Legal Values Specifies if the access type of the vFlash SD partition is Read-Only or Read-Write. • 1 — Read Only • 0 — Read Write Default value 1 — Read Only Write Privilege Login and configure iDRAC License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. Partition at the specified index must be created. iDRAC.vflashpartition.
iDRAC.vflashpartition.FormatType (Read or Write) Table 757. Details of iDRAC.vflashpartition.FormatType attribute Description Legal Values Specifies the file system format type of the vFlash SD partition. • • • • • FAT16 FAT32 EXT2 EXT3 RAW Default value None Write Privilege Login and configure iDRAC License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. Partition at the specified index must be created. iDRAC.vflashpartition.Size (Read or Write) Table 758. Details of iDRAC.
iDRAC.vflashsd The objects in this group manage vFlash SD properties on iDRAC. iDRAC.vflashsd.AvailableSize (Read or Write) Table 760. Details of iDRAC.vflashsd.AvailableSize attribute Description Displays the available memory (in MB) on the vFlash SD card that is used to create new partitions. Legal Values Integer value in MB. Default value If the card is not initialized, then the default value is 0. If initialized, then it displays the unused memory on the card.
Dependency vFlash SD card must be enabled. iDRAC.vflashsd.Initialized (Read or Write) Table 763. Details of attribute Description Legal Values Specifies if the vFlash SD card is initialized or not. • • 0 — Not Initialized 1 — Initialized Default value None Write Privilege Login and configure iDRAC License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. iDRAC.vflashsd.Licensed (Read or Write) Table 764. Details of iDRAC.vflashsd.
iDRAC.vflashsd.WriteProtect (Read or Write) Table 766. Details of iDRAC.vflashsd.WriteProtect attribute Description Legal Values Displays if the physical write protect is enabled or disabled on the vFlash SD card. • 0 — Disabled • 1 — Enabled Default value None Write Privilege Login and configure iDRAC License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. iDRAC.VirtualConsole The objects in this group enable you to manage virtual console configuration parameters of iDRAC.
• 2-Auto-Attach Default Value 2-Auto-Attach Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.VirtualConsole.Enable (Read or Write) Table 769. Details of iDRAC.VirtualConsole.Enable attribute Description Enables or disables the Virtual Console. Legal Values • 0 — Disabled • 1 — Enabled Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.
iDRAC.VirtualConsole.LocalVideo (Read or Write) Table 771. Details of iDRAC.VirtualConsole.LocalVideo attribute Description Enables or disables the local server video. Legal Values • 0 — Disabled • 1 — Enabled Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualConsole.MaxSessions (Read or Write) Table 772. Details of iDRAC.VirtualConsole.
Write Privilege Configure iDRAC License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualConsole.Port (Read or Write) Table 774. Details of iDRAC.VirtualConsole.Port attribute Description Specifies the virtual KVM port. Legal Values Integral values: 1–65535 Default Value 5900 Write Privilege Configure iDRAC License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualConsole.Timeout (Read or Write) Table 775.
iDRAC.VirtualMedia.Attached (Read or Write) Table 776. Details of iDRAC.VirtualMedia.Attached attribute Description Used to attach virtual devices to the system using the USB bus. Legal Values • 0 — Detached • 1 — Attached • 2 — AutoAttach Default Value 2 — AutoAttach Write Privilege Virtual Media License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualMedia.BootOnce (Read or Write) Table 777. Details of iDRAC.VirtualMedia.
Write Privilege Virtual Media License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualMedia.EncryptEnable (Read or Write) Table 779. Details of iDRAC.VirtualMedia.EncryptEnable attribute Description Specifies the Virtual Media encryption Legal Values • 0—Disabled • 1—Enabled Default Value 0—Disabled Write Privilege Virtual Media License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualMedia.
iDRAC.VNCServer.Enable (Read or Write) Table 781. Details of iDRAC.VNCServer.Enable attribute Description Legal Values Enables or disables VNC server on iDRAC. • 0 — Disabled • 1 — Enabled Default value 0 — Disabled Write Privilege Login or configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.VNCServer.LowerEncryptionBitLength (Read or Write) Table 782. Details of iDRAC.VNCServer.LowerEncryptionBitLength attribute Description Legal Values Lower encryption bit length.
iDRAC.VNCServer.Port (Read or Write) Table 784. Details of iDRAC.VNCServer.Port attribute Description Port number for VNC session Legal Values Integer values from 1024 to 65535 Default Value 5901 Write Privilege Login or configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.VNCServer.SSLEncryptionBitLength (Read or Write) Table 785. Details of iDRAC.VNCServer.SSLEncryptionBitLength attribute Description Legal Values Indicates the VNC server encryption state.
iDRAC.WebServer The objects in this group provide configuration parameters for iDRACs' Webserver. iDRAC.Webserver.CustomCipherString(Read or Write) Table 787. Details of iDRAC.webserver.CustomCipherString attribute Description Specifies the custom cipher string to filter the available in-use TLS cipher suite.
iDRAC.WebServer.HttpPort (Read or Write) Table 789. Details of iDRAC.WebServer.HttpPort attribute Description Specifies the port number for HTTP communication with the iDRAC. Legal Values Integral values: 1–65535 Default Value 80 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.WebServer.HttpsPort (Read or Write) Table 790. Details of iDRAC.WebServer.
iDRAC.WebServer.LowerEncryptionBitLength (Read or Write) Table 792. Details of iDRAC.WebServer.LowerEncryptionBitLength attribute Description Lower Encryption Bit Length. Legal Values • 0 — Disabled (Auto Negotiate) • 1 — Enabled (12 Bit or Higher) Default Value 1 — Enabled (128 Bit or Higher) Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.WebServer.SSLEncryptionBitLength (Read or Write) Table 793. Details of iDRAC.WebServer.
• 5- Custom Default Value Null Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.webServer.TitleBarOptionCustom (Read or Write) Table 795. Details of iDRAC.webServer.TitleBarOptionCustom attribute Description Specifies the custom title when the title bar option is Custom.
• • 1 — TLS 1.1 and higher 2 — TLS 1.2 only Default Value 1 — TLS 1.1 and higher Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.BiosBootSettings You can manage the BIOS start settings using the objects in this group. BIOS.BiosBootSettings.BootSeq (Read or Write) Table 798. Details of BIOS.BiosBootSettings.BootSeq attribute Description Determines the Bios start sequence of the system.
BIOS.BiosBootSettings.BootSeqRetry (Read or Write) Table 800. Details of BIOS.BiosBootSettings.BootSeqRetry attribute Description Enables or disables the boot sequence retry feature. Legal Values Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.BiosBootSettings.HddFailover (Read or Write) Table 801. Details of BIOS.BiosBootSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if Boot mode is set to UEFI BIOS.BiosBootSettings.UefiBootSeq (Read or Write) Table 803. Details of BIOS.BiosBootSettings.UefiBootSeq attribute Description UEFI boot sequence Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if Boot mode is set to BIOS BIOS.BiosBootSettings.SetBootOrderFqddn (Read or Write) Table 804.
Dependency None BIOS.EmbServerMgmt The objects in this group assist in embedded server management. BIOS.EmbServerMgmt.FrontLcd (Read or Write) Table 806. Details of BIOS.EmbServerMgmt.FrontLcd attribute Description Legal Values Allows to display the default (Model name and number) or a user-defined string in the front-panel LCD. To modify the advanced features of the front-panel LCD, press F2 during boot to enter System Setup and then select iDRAC Settings.
BIOS.IntegratedDevices.EmbNic1 (Read or Write) Table 808. Details of BIOS.IntegratedDevices.EmbNic1 attribute Description Legal Values Enables or disables the operating system interface of the embedded NIC1. • • • • Enabled EnabledPxe EnablediScsi Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.EmbNic1Nic2 (Read or Write) Table 809. Details of BIOS.IntegratedDevices.
• Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.EmbNic3 (Read or Write) Table 811. Details of BIOS.IntegratedDevices.EmbNic3 attribute Description Legal Values Enables or disables the operating system interface of the embedded NIC3.
BIOS.IntegratedDevices.EmbNic4 (Read or Write) Table 813. Details of BIOS.IntegratedDevices.EmbNic4 attribute Description Legal Values Enables or disables the operating system interface of the embedded NIC4. • • • • Enabled EnabledPxe EnablediScsi Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.EmbVideo (Read or Write) Table 814. Details of IOS.IntegratedDevices.
Write Privilege Server control License Required RACADM Dependency None BIOS.IntegratedDevices.IntegratedNetwork1 (Read or Write) Table 816. Details of BIOS.IntegratedDevices.IntegratedNetwork1 attribute Description Legal Values Enables or disables the Integrated Network Card 1. • • Enabled Disabled OS Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.
• Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.IntegratedSas (Read or Write) Table 819. Details of BIOS.IntegratedDevices.IntegratedSas attribute Description Legal Values Enables or disables the integrated SAS controller. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
BIOS.IntegratedDevices.InternalSdCardRedundancy (Read or Write) Table 821. Details of BIOS.IntegratedDevices.InternalSdCardRedundancy attribute Description Legal Values Sets the SD Card redundancy mode. • • Mirror Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if InternalSdCard is set to 'Off'. BIOS.IntegratedDevices.InternalUsb (Read or Write) Table 822. Details of BIOS.IntegratedDevices.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.InternalUsb2 (Read or Write) Table 824. Details of BIOS.IntegratedDevices.InternalUsb2 attribute Description Legal Values Enables or disables the internal USB port 2. • • On Off Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.IONonPostedPrefetch Table 825.
BIOS.IntegratedDevices.IoatEngine (Read or Write) Table 826. Details of BIOS.IntegratedDevices.IoatEngine attribute Description Legal Values Enables or disables the I/O Acceleration technology (I/OAT) option. • • Enabled Disabled Default Value Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.IONonPostedPrefetch Table 827. Details of BIOS.IntegratedDevices.
Dependency None BIOS.IntegratedDevices.OsWatchdogTimer (Read or Write) Table 829. Details of BIOS.IntegratedDevices.OsWatchdogTimer attribute Description Legal Values Enables or disables timer initialization by the operating system. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.SriovGlobalEnable (Read or Write) Table 830. Details of BIOS.IntegratedDevices.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings To manage memory-related configuration settings, use the objects in this group. BIOS.MemSettings.MemLowPower (Read or Write) Table 832. Details of BIOS.MemSettings.MemLowPower attribute Description Legal Values Enables or disables the low-power mode of the memory.
BIOS.MemSettings.MemOptimizer (Read or Write) Table 834. Details of BIOS.MemSettings.MemOptimizer attribute Description Legal Values Configure the memory optimizer setting. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.MemOpVoltage (Read Only) Table 835. Details of BIOS.MemSettings.MemOpVoltage attribute Description Legal Values Operating voltage of memory.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.NodeInterleave (Read or Write) Table 837. Details of BIOS.MemSettings.NodeInterleave attribute Description Legal Values If the system is configured with matching memory this field enables node interleaving. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.RedundantMem (Read or Write) Table 838.
BIOS.MemSettings.RedundantMemCfgValid (Read or Write) Table 839. Details of BIOS.MemSettings.RedundantMemCfgValid attribute Description Legal Values Redundant Memory Configuration Valid • • Invalid Valid Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.RedundantMemInUse (Read Only) Table 840. Details of BIOS.MemSettings.
Dependency None BIOS.MemSettings.SnoopFilter (Read or Write) Table 842. Details of BIOS.MemSettings.SnoopFilter attribute Description Enables or disables the snoop filter option. NOTE: This attribute is not supported for 13th generation servers. Legal Values • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.SysMemSize (Read or Write) Table 843. Details of BIOS.MemSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.SysMemType (Read or Write) Table 845. Details of BIOS.MemSettings.SysMemType attribute Description Indicates the current type of main memory installed in the system. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.SysMemVolt (Read or Write) Table 846. Details of BIOS.MemSettings.
Dependency None BIOS.MiscSettings To manage the miscellaneous objects settings, use the object in this group. BIOS.MiscSettings.AssetTag (Read or Write) Table 848. Details of BIOS.MiscSettings.AssetTag attribute Description Displays the current asset tag and the asset tag can be modified. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.ErrPrompt (Read or Write) Table 849.
• Disabled Default Value Not Applicable License Required RACADM Dependency None BIOS.MiscSettings.NumLock (Read or Write) Table 851. Details of BIOS.MiscSettings.NumLock attribute Description Legal Values Enable or disable the system boots with Num locks, not applicable for 84-key keyboards • • On Off Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.ReportKbdErr (Read or Write) Table 852.
BIOS.MiscSettings.SystemUefiShell (Read or Write) Table 853. Details of BIOS.MiscSettings.SystemUefiShell attribute Description Legal Values Enables or disables the System UEFI Shell as a UEFI boot option choice. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.SysMgmtNVByte1 (Read or Write) Table 854. Details of attribute Description Indicates the system management NVRAM byte 1.
BIOS.MiscSettings.SystemUefiShell (Read or Write) Table 856. Details of BIOS.MiscSettings.SystemUefiShell attribute Description Legal Values Enables or disables the system UEFI shell as UEFI boot option. • Enabled • Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.ForceInt10 (Read or Write) Table 857. Details of BIOS.MiscSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.OneTimeBoot You can manage the one time boot settings using the objects in this group. BIOS.OneTimeBoot.OneTimeBootMode (Read or Write) Table 859. Details of BIOS.OneTimeBoot.OneTimeBootMode attribute Description Legal Values Configure the one time boot mode setting.
BIOS.OneTimeBoot.OneTimeCustomBootStr (Read or Write) Table 861. Details of BIOS.OneTimeBoot.OneTimeCustomBootStr attribute Description Configure the one time custom boot device. Legal Values Custom device list Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if OneTimeBootMode is set to Disabled or set to OneTimeBootSeq, OneTimeHddSeq, or OneTimeUefiBootSeq BIOS.OneTimeBoot.
BIOS.ProcSettings To configure the processor settings, use the objects in this group. BIOS.ProcSettings.CorePerfBoost (Read or Write) Table 864. Details of BIOS.ProcSettings.CorePerfBoost attribute Description Legal Values Enables or disables CPU core performance booster. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.DataReuse (Read or Write) Table 865. Details of BIOS.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.DcuStreamerPrefetcher (Read or Write) Table 867. Details of BIOS.ProcSettings.DcuStreamerPrefetcher attribute Description Legal Values Enables or disables Data Cache Unit (DCU) Streamer Prefetcher.
BIOS.ProcSettings.DynamicCoreAllocation (Read or Write) Table 869. Details of BIOS.ProcSettings.DynamicCoreAllocation attribute Description Legal Values Enables or disables the operating system capability to set the logical processors in idle state which helps to reduce power consumption. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.LogicalProc (Read or Write) Table 870.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc1Brand (Read or Write) Table 872. Details of BIOS.ProcSettings.Proc1Brand attribute Description Provides the processor brand name. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc1ControlledTurbo (Read or Write) Table 873. Details of BIOS.ProcSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc1L2Cache (Read or Write) Table 875. Details of BIOS.ProcSettings.Proc1L2Cache attribute Description Amount of memory in the corresponding processor cache. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc2Brand (Read or Write) Table 878. Details of BIOS.ProcSettings.Proc2Brand attribute Description Provides the processor brand name. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc2ControlledTurbo (Read or Write) Table 879. Details of BIOS.ProcSettings.
BIOS.Procsettings.Proc2Cores Table 880. Details of BIOS.Procsettings.Proc2Cores attribute Description Controls the number of enabled cores in each processor. Legal Values All, 1, 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24 Default Value NA Write Privilege Server control License Required RACADM Dependency Requires the DPAT Pro license to make it visible. It can be edited only if the Number of Cores per Processor is set to Custom. BIOS.ProcSettings.Proc2Id (Read or Write) Table 881.
BIOS.ProcSettings.Proc2L3Cache (Read or Write) Table 883. Details of BIOS.ProcSettings.Proc2L3Cache attribute Description Amount of memory in the corresponding processor cache. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc2NumCores (Read or Write) Table 884. Details of BIOS.ProcSettings.Proc2NumCores attribute Description Number of cores in the processor package.
BIOS.ProcSettings.Proc3ControlledTurbo (Read or Write) Table 886. Details of BIOS.ProcSettings.Proc3ControlledTurbo attribute Description Controls the turbo engagement. NOTE: You can enable this option only when System Profile is set to Performance.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None c(Read or Write) Table 889. Details of BIOS.ProcSettings.Proc3Id attribute Description Amount of memory in the corresponding processor cache. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc3L3Cache (Read or Write) Table 890. Details of BIOS.ProcSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc4Brand (Read or Write) Table 892. Details of BIOS.ProcSettings.Proc4Brand attribute Description The processor manufacturer provides brand text Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc4ControlledTurbo (Read or Write) Table 893. Details of BIOS.ProcSettings.
Default Value NA Write Privilege Server control License Required RACADM Dependency Requires the DPAT Pro license to make it visible. It can be edited only if the Number of Cores per Processor is set to Custom. BIOS.ProcSettings.Proc4Id (Read or Write) Table 895. Details of BIOS.ProcSettings.Proc4Id attribute Description Processor's family model and stepping values.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc4NumCores (Read or Write) Table 898. Details of BIOS.ProcSettings.Proc4NumCores attribute Description Number of cores in the processor package. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc64bit (Read or Write) Table 899.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcBusSpeed (Read or Write) Table 901. Details of BIOS.ProcSettings.ProcBusSpeed attribute Description Bus speed of the processor. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcConfigTdp (Read or Write) Table 902.
• • • • • • • • • 1 2 4 6 8 10 12 14 16 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcCoreSpeed (Read or Write) Table 904. Details of vattribute Description Clock speed of the processor. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.
Dependency None BIOS.ProcSettings.ProcExecuteDisable (Read or Write) Table 906. Details of BIOS.ProcSettings.ProcExecuteDisable attribute Description Legal Values Specifies whether Execute Disable Memory Protection Technology is enabled or disabled. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcHpcMode (Read or Write) Table 907. Details of BIOS.ProcSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcHwPrefetcher (Read or Write) Table 909. Details of BIOS.ProcSettings.ProcHwPrefetcher attribute Description Legal Values When enabled, the processor is able to prefetch extra cache lines for every memory request. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
BIOS.ProcSettings.ProcSoftwarePrefetcher (Read or Write) Table 911. Details of BIOS.ProcSettings.ProcSoftwarePrefetcher attribute Description Legal Values Enables or disables the hardware prefetcher for considering software prefetches when detecting strides for prefetch requests. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcVirtualization (Read or Write) Table 912.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if the ProcVirtualization attribute is set to Disabled. BIOS.ProcSettings.QpiBandwidthPriority (Read or Write) Table 914. Details of BIOS.ProcSettings.QpiBandwidthPriority attribute Description Legal Values Sets the bandwidth priority to compute (default) or I/O.
BIOS.ProcSettings.RtidSetting (Read or Write) Table 916. Details of BIOS.ProcSettings.RtidSetting attribute Description Legal Values Allocates more RTIDs to the remote socket increasing cache performance between the sockets. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProxyAttributes The objects in this group manage the legacy boot protocol of LOM. BIOS.ProxyAttributes.
BIOS.ProxyAttributes.IntNic1PortnBootproto (Read or Write) Table 918. Details ofBIOS.ProxyAttributes.IntNic1PortnBootproto attribute Description Legal Values Controls the Legacy Boot Protocol of the LOM Port specified by the Embedded NIC port number Port. Assists for system management software use and does not appear in System BIOS Setup. For this attribute, the value of n can be 1–4. This attribute returns Unknown when read.
BIOS.PxeDev1Settings.PxeDevnProtocol (Read or Write) Table 920. Details of BIOS.PxeDev1Settings.PxeDevnProtocol attribute Description Legal Values Controls the PXE protocol used for the specified PXE device. For the attribute PxeDevnProtocol, the value of n can be 1 — 4. • • IPv4 IPv6 Default Value None Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.PxeDev1Settings.PxeDevnVlanEnDis (Read or Write) Table 921. Details of BIOS.PxeDev1Settings.
BIOS.PxeDev1Settings.PxeDevnVlanPriority (Read or Write) Table 923. Details of BIOS.PxeDev1Settings.PxeDevnVlanPriority attribute Description Indicates the VLAN priority for the specific PXE device. For the attribute PxeDevnVlanPriority, the value of n can be 1 — 4. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings Use the objects in this group to configure the BIOS SATA settings.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.eSataPort1DriveType (Read or Write) Table 926. Details of BIOS.SataSettings.eSataPort1DriveType attribute Description Indicates type of device attached to this SATA port. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.eSataPort1Model (Read or Write) Table 927. Details of BIOS.SataSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortACapacity (Read or Write) Table 929. Details of IOS.SataSettings.SataPortACapacity attribute Description Displays the total capacity of a hard-disk drive. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortADriveType (Read or Write) Table 930.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortB (Read or Write) Table 932. Details of BIOS.SataSettings.SataPortB attribute Description Legal Values Sets the drive type of the selected device. • • Off Auto Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortBCapacity (Read or Write) Table 933.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortBModel (Read or Write) Table 935. Details of BIOS.SataSettings.SataPortBModel attribute Description Displays the drive model of the selected device. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortC (Read or Write) Table 936. Details of BIOS.SataSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortCDriveType (Read or Write) Table 938. Details of BIOS.SataSettings.SataPortCDriveType attribute Description Indicates type of device attached to this SATA port. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortCModel (Read or Write) Table 939. Details of BIOS.SataSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortDCapacity (Read or Write) Table 941. Details of BIOS.SataSettings.SataPortDCapacity attribute Description Displays the total capacity of a hard-disk drive. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortDDriveType (Read or Write) Table 942.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortE (Read or Write) Table 944. Details of BIOS.SataSettings.SataPortE attribute Description Legal Values Sets the drive type of the selected device. • • Off Auto Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortECapacity (Read or Write) Table 945.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortEModel (Read or Write) Table 947. Details of BIOS.SataSettings.SataPortEModel attribute Description Displays the drive model of the selected device. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortF (Read or Write) Table 948. Details of BIOS.SataSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortFDriveType (Read or Write) Table 950. Details of BIOS.SataSettings.SataPortFDriveType attribute Description Indicates type of device attached to this SATA port. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortFModel (Read or Write) Table 951. Details of BIOS.SataSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortGCapacity (Read or Write) Table 953. Details of BIOS.SataSettings.SataPortGCapacity attribute Description Displays the total capacity of a hard-disk drive. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortGDriveType (Read or Write) Table 954.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortH (Read or Write) Table 956. Details ofBIOS.SataSettings.SataPortH attribute Description Legal Values Sets the drive type of the selected device. • • Off Auto Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortHCapacity (Read or Write) Table 957. Details of BIOS.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortHModel (Read Only) Table 959. Details of BIOS.SataSettings.SataPortHModel attribute Description Displays the drive model of the selected device. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortI (Read or Write) Table 960. Details of BIOS.SataSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortIDriveType (Read or Write) Table 962. Details of BIOS.SataSettings.SataPortIDriveType attribute Description Indicates the type of device attached to this SATA port. Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortJCapacity (Read or Write) Table 965. Details of BIOS.SataSettings.SataPortJCapacity attribute Description Displays the total capacity of a hard-disk drive. This property is not defined for removable-media devices such as optical drives.
BIOS.SataSettings.SecurityFreezeLock (Read or Write) Table 968. Details of BIOS.SataSettings.SecurityFreezeLock attribute Description Legal Values Directs the Security Freeze Lock command to the Embedded SATA drives during POST. This option is only applicable for ATA and AHCI mode, and not applicable for RAID mode. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SerialCommSettings.FailSafeBaud (Read or Write) Table 971. Details of BIOS.SerialCommSettings.FailSafeBaud attribute Description Legal Values BIOS attempts to determine the baud rate automatically. This fail-safe baud rate is used only if the attempt is unsuccessful.
BIOS.SerialCommSettings.SerialComm (Read or Write) Table 973. Details of BIOS.SerialCommSettings.SerialComm attribute Description Legal Values Controls the serial communication options. • • • • • Off OnNoConRedir OnConRedirCom1 OnConRedirCom2 OnConRedir Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SerialCommSettings.SerialPortAddress (Read or Write) Table 974. Details of BIOS.SerialCommSettings.
BIOS.SlotDisablement.Slot1 (Read or Write) Table 975. Details of BIOS.SlotDisablement.Slot1 attribute Description Legal Values Control the configuration of the card installed in slot1. • • • Enabled Disabled BootDriverDisabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.Slot2 (Read or Write) Table 976. Details of BIOS.SlotDisablement.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.Slot4 (Read or Write) Table 978. Details of BIOS.SlotDisablement.Slot4 attribute Description Legal Values Control the configuration of the card installed in slot 4. • • • Enabled Disabled BootDriverDisabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.
BIOS.SlotDisablement.Slot6 (Read or Write) Table 980. Details of BIOS.SlotDisablement.Slot6 attribute Description Legal Values Control the configuration of the card installed in slot 6. • • • Enabled Disabled BootDriverDisabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.Slot7 (Read or Write) Table 981. Details of BIOS.SlotDisablement.
NOTE: If multiple cards from the same manufacturer are managed using the same boot driver, select BootDriverDisabled option for all the cards from the same manufacturer so that the Option ROM is not run. Legal Values • • • Enabled Disabled BootDriverDisabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.Slot9 (Read or Write) Table 983. Details of BIOS.SlotDisablement.
NOTE: If multiple cards from the same manufacturer are managed using the same boot driver, select BootDriverDisabled value for all the cards from the same manufacturer so that the Option ROM is not run. Legal Values • • • Enabled Disabled BootDriverDisabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysInformation To view information about system configuration, use the objects in this group. BIOS.
Dependency None BIOS.SysInformation.SystemCpldVersion (Read or Write) Table 987. Details of IOS.SysInformation.SystemCpldVersion attribute Description Displays the current revision of the system CPLD firmware. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysInformation.SystemManufacturer (Read or Write) Table 988. Details of BIOS.SysInformation.
BIOS.SysInformation.SystemServiceTag (Read or Write) Table 990. Details of BIOS.SysInformation.SystemServiceTag attribute Description The Service Tag assigns the Original Equipment Manufacturer of this system. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency` None BIOS.SysInformation.UefiComplianceVersion (Read or Write) Table 991. Details of BIOS.SysInformation.
License Required iDRAC Express or iDRAC Enterprise Dependency Enabled only when SysProfileSettings.ProcPwrPerf is set to SysDbpm in Custom mode. BIOS.SysProfileSettings.EnergyEfficientTurbo (Read or Write) Table 993. Details of BIOS.SysProfileSettings.EnergyEfficientTurbo attribute Description Legal Values Enables or disables the energy efficient turbo.
• • • • 1333MHz 1067MHz 800MHz MaxReliability Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.MemPatrolScrub (Read or Write) Table 996. Details of BIOS.SysProfileSettings.
BIOS.SysProfileSettings.MemRefreshRate (Read or Write) Table 998. Details of BIOS.SysProfileSettings.MemRefreshRate attribute Description Legal Values Frequency at which memory is normally refreshed. • • 1x 2x Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.MemVolt (Read or Write) Table 999. Details of BIOS.SysProfileSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency Disabled only when SysProfileSettings.ProcCStates state is disabled in Custom mode. BIOS.SysProfileSettings.PowerDelivery (Read or Write) Table 1001. Details of BIOS.SysProfileSettings.PowerDelivery attribute Description Legal Values Sets the power delivery mode. • • MaxReliability MinPwr Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.ProcPwrPerf (Read or Write) Table 1004. Details of BIOS.SysProfileSettings.ProcPwrPerf attribute Description Legal Values Sets CPU power management to maximum performance operating system DBPM or System DBPM (DAPC) mode.
BIOS.SysProfileSettings.ProcTurboMode (Read or Write) Table 1006. Details of BIOS.SysProfileSettings.ProcTurboMode attribute Description Legal Values When enabled, the processor can operate in Turbo Boost Mode. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.SysProfile (Read or Write) Table 1007.
• Clear, all the contents of TPM is cleared. Clearing the TPM will cause loss of all keys in the TPM. NOTE: The clearing can affect starting the operating system.. Legal Values • • • • None Activate Deactivate Clear Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysProfileSettings.UncoreFrequency (Read or Write) Table 1009. Details of IOS.SysProfileSettings.
BIOS.SysSecurity To manage the system security properties of the BIOS, use the objects in this group. NOTE: After modifying the IntelTxt attribute value, the pending flag is enabled for the dependent attributes such as TpmActivation, TpmClear, and TpmSecurity. BIOS.SysSecurity.AcPwrRcvry (Read or Write) Table 1011. Details of BIOS.SysSecurity.AcPwrRcvry attribute Description Legal Values Specifies how the system responds after AC power is restored to the system.
BIOS.SysSecurity.AcPwrRcvryUserDelay (Read or Write) Table 1013. Details of BIOS.SysSecurity.AcPwrRcvryUserDelay attribute Description Controls the user-defined AC Recovery Delay. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.Aesni (Read or Write) Table 1014. Details of BIOS.SysSecurity.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.IntelTxt (Read or Write) Table 1016. Details of BIOS.SysSecurity.IntelTxt attribute Description Enables or disables Trusted Execution technology. NOTE: When the IntelTxt value is set to ‘on’, then the following values are set: TpmActivation=NoChange (Pending Value=NoChange), TpmClear=No (Pending Value=No), TpmSecurity=OnPbm (Pending Value=OnPbm).
BIOS.SysSecurity.PasswordStatus (Read or Write) Table 1018. Details of BIOS.SysSecurity.PasswordStatus attribute Description Legal Values Locks the system password. • • Locked Unlocked Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.PwrButton (Read or Write) Table 1019. Details of BIOS.SysSecurity.PwrButton attribute Description Legal Values Enables or disables the power button on the front panel.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.SetupPassword (Read or Write) Table 1021. Details of IOS.SysSecurity.SetupPassword attribute Description Set up the system password. Optional parameter –o is used with this object to provide old password as an authentication for changing the previously configured password to the new password.
BIOS.SysSecurity.SHA256SetupPasswordSalt (Read or Write) Table 1023. Details of BIOS.SysSecurity.SHA256SetupPasswordSalt attribute Description Indicates the Salt string added to the setup password before hash. Legal Values String of 32 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.SignedFirmwareUpdate (Read or Write) Table 1024. Details of BIOS.SysSecurity.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.SHA256SystemPassword (Read or Write) Table 1026. Details of BIOS.SysSecurity.SHA256SystemPassword attribute Description Indicates the SHA256 hash of the system password. Legal Values String of 64 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.TcmClear (Read or Write) Table 1029. Details of BIOS.SysSecurity.TcmClear attribute Description Legal Values Warns that clearing the TPM causes loss of all keys in the TPM. It may affect starting the operating system. • • Yes No Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.
• • Activate Deactivate Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysSecurity.TpmSecurity is set to Off. BIOS.SysSecurity.TpmClear (Read or Write) Table 1032. Details of BIOS.SysSecurity.TpmClear attribute Description Legal Values Warns that clearing the TPM causes loss of all keys in the TPM. It may affect starting the operating system.
BIOS.SysSecurity.TpmPpiBypassClear Table 1034. Details of BIOS.SysSecurity.TpmPpiBypassClear attribute Description Clears the Physical Presence Interface (PPI) Advanced Configuration and Power Interface (ACPI) and enables the operating system to by-pass the PPI-related prompts. Legal Values • • Default Value NA Write Privilege Server control License Required RACADM Dependency None Enabled Disabled BIOS.SysSecurity.TpmPpiBypassProvision Table 1035. Details of BIOS.SysSecurity.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.TPMStatus (Read Only) Table 1037. Details of BIOS.SysSecurity.TPMStatus attribute Description Displays the status of TPM. Legal Values String of up to 64 ASCII characters. Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
BIOS.UefiBootSettings.UefiPxeIpVersion (Read or Write) Table 1039. Details of BIOS.UefiBootSettings.UefiPxeIpVersion attribute Description Legal Values Enables to select the IPv4 PXE booting (default) or IPv6 PXE booting when in UEFI boot mode. This property is disabled in BIOS boot mode. If this property is modified, the PXE options in the UEFI boot sequence is replaced on the next restart.
FC.FCDevice.EFIVersion (Read Only) Table 1042. Details of attribute Description Indicates the version of the EFI device driver. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.FCDevice.FamilyVersion (Read Only) Table 1043. Details of FC.FCDevice.FamilyVersion attribute Description Indicates the firmware’s family version.
FC.FCTarget.BootScanSelection (Read or Write) Table 1045. Details of FC.FCTarget.BootScanSelection attribute Description Legal Values Sets the port’s operation while starting the system from Fiber Channel target(s). Only operations supported by the option-ROM should be implemented.
FC.FCTarget.FirstFCTargetWWPN (Read or Write) Table 1048. Details of FC.FCTarget.FirstFCTargetWWPN attribute Description Specifies the World Wide Port Name of the first Fibre Channel boot target. Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.FCTarget.SecondFCTargetWWPN (Read or Write) Table 1049. Details of FC.FCTarget.
FC.HBAConfig.FabricLoginTimeout (Read or Write) Table 1051. Details of FC.HBAConfig.FabricLoginTimeout attribute Description Sets the SAN Fabric login time out. Legal Values Not Applicable Default Value 3000 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.FabricLoginRetryCount (Read or Write) Table 1052. Details of FC.HBAConfig.FabricLoginRetryCount attribute Description Sets the current SAN Fabric login retry count.
FC.HBAConfig.HardZone (Read or Write) Table 1054. Details of FC.HBAConfig.HardZone attribute Description Legal Values Enables or disables the Fibre Channel hard zone. • Enabled • Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.HardZoneAddress (Read or Write) Table 1055. Details of FC.HBAConfig.HardZoneAddress attribute Description Sets the Hard Zone address.
FC.HBAConfig.LoopResetDelay (Read or Write) Table 1057. Details of FC.HBAConfig.LoopResetDelay attribute Description Sets the arbitrated Loop Reset Delay for the port in seconds. Legal Values Not Applicable Default Value 5 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.PortDownRetryCount (Read or Write) Table 1058. Details of FC.HBAConfig.
FC.HBAConfig.PortLoginRetryCount (Read or Write) Table 1060. Details of FC.HBAConfig.PortLoginRetryCount attribute Description Sets the target Port login retry count. Legal Values Not Applicable Default Value 3 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.PortLoginTimeout (Read or Write) Table 1061. Details of FC.HBAConfig.PortLoginTimeout attribute Description Sets the target port login time out.
FC.PortConfig.FCDevice (Read Only) Table 1063. Details of FC.PortConfig.FCDevice attribute Description Displays the version of the device and firmware. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.PortConfig.FCTarget (Read Only) Table 1064. Details of FC.PortConfig.
FC.PortConfig.PortNumber (Read Only) Table 1066. Details of FC.PortConfig.PortNumber attribute Description Indicates the Fibre Channel Host Bus Adapter port number. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.PortConfig.PortSpeed (Read or Write) Table 1067. Details of FC.PortConfig.
FC.PortConfig.VirtualWWPN (Read or Write) Table 1069. Details of FC.PortConfig.VirtualWWPN attribute Description Indicates the virtual Fibre Channel World Wide Port Name of the port. Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.PortConfig.WWN (Read Only) Table 1070. Details of FC.PortConfig.
NIC.ConfigureFormn.BusDeviceFunction (Read Only) Table 1072. Details of NIC.ConfigureFormn.BusDeviceFunction attribute Description Indicates the value of the bus device function. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.MacAddr (Read Only) Table 1073. Details of NIC.ConfigureFormn.MacAddr attribute Description Indicates the permanent MAC address.
NIC.ConfigureFormn.IscsiMacAddr (Read Only) Table 1075. Details of NIC.ConfigureFormn.IscsiMacAddr attribute Description Indicates the permanent MAC address for iSCSI off load. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.iScsiOffloadMode (Read or Write) Table 1076. Details of NIC.ConfigureFormn.
NIC.ConfigureFormn.NicMode (Read or Write) Table 1078. Details of NIC.ConfigureFormn.NicMode attribute Description Legal Values Enables or disables the NIC mode on the partition. • Enabled • Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.PCIDeviceID (Read Only) Table 1079. Details of NIC.ConfigureFormn.PCIDeviceID attribute Description Indicates the PCI Device ID of the partition.
NIC.ConfigureFormn.WWPN (Read Only) Table 1081. Details of NIC.ConfigureFormn.WWPN attribute Description Indicates the Fibre Channel World Wide Port Name identifier for FCoE. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC_ConfigureFormn.VirtWWN (Read or Write) Table 1082.
NIC_ConfigureFormn.VirtMacAddr (Read or Write) Table 1084. Details of NIC_ConfigureFormn.VirtMacAddr attribute Description Assigns MAC address for partition. Legal Values Not Applicable Default Value 00:00:00:00:00:00 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC_ConfigureFormn.VirtIscsiMacAddr (Read or Write) Table 1085. Details of attribute Description Assigns the MAC address for partition iSCSI off load.
NIC.DCBSettings.CongestionNotification (Read Only) Table 1087. Details of NIC.DCBSettings.CongestionNotification attribute Description Legal Values Indicates whether Congestion Notification capability is supported. • • Available Unavailable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.DCBSettings.DCBExchangeProtocol (Read Only) Table 1088. Details of NIC.DCBSettings.
Dependency None NIC.DCBSettings.PriorityFlowControl (Read Only) Table 1090. Details of NIC.DCBSettings.PriorityFlowControl attribute Description Legal Values Indicates whether Priority Flow Control capability is supported. • • Available Unavailable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.DeviceLevelConfig To manage the device level configurations, use the objects in this group.
NIC.DeviceLevelConfig.FlowControlSetting (Read or Write) Table 1092. Details of NIC.DeviceLevelConfig.FlowControlSetting attribute Description Legal Values Configure type of Flow Control used. • • • • Auto TX:Send Pause on RX Overflow RX:Throttle TX on Pause Received TX RX Flow Control Default Value Auto Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.DeviceLevelConfig.NParEP (Read or Write) Table 1093.
License Required iDRAC Express or iDRAC Enterprise Dependency` None NIC.DeviceLevelConfig.VirtualizationMode (Read or Write) Table 1095. Details of NIC.DeviceLevelConfig.VirtualizationMode attribute Description Legal Values Specifies the type of virtualization used by the controller on all ports.
NIC.FCOECapabilities.MaxFrameSize (Read Only) Table 1097. Details of NIC.FCOECapabilities.MaxFrameSize attribute Description Indicates the maximum frame size for each FCoE frame. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCOECapabilities.MaxIOsPerSession (Read Only) Table 1098. Details of NIC.FCOECapabilities.
NIC.FCOECapabilities.MaxNumberExchanges (Read Only) Table 1100. Details of NIC.FCOECapabilities.MaxNumberExchanges attribute Description Indicates the maximum number of exchanges supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCOECapabilities.MaxNumberLogins (Read Only) Table 1101. Details of NIC.FCOECapabilities.
NIC.FCOECapabilities.MaxNumberOutStandingCommands (Read Only) Table 1103. Details of NIC.FCOECapabilities.MaxNumberOutStandingCommands attribute Description Indicates the maximum number of outstanding commands supported across all sessions. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCOECapabilities.MTUReconfigurationSupport (Read Only) Table 1104. Details of NIC.FCOECapabilities.
NIC.FCoEConfiguration.ConnectFirstFCoETarget (Read or Write) Table 1105. Details of NIC.FCoEConfiguration.ConnectFirstFCoETarget attribute Description Legal Values Specifies whether FCoE initiator is used to connect to the first FCoE storage target defined. • • Enabled Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEConfiguration.BootOrderFirstFCoETarget (Read or Write) Table 1106. Details of NIC.
Dependency Not Applicable NIC.FCoEConfiguration.BootOrderThirdFCoETarget (Read or Write) Table 1108. Details of NIC.FCoEConfiguration.BootOrderThirdFCoETarget attribute Description Specifies the port's third defined target in the FCoE boot. Legal Values Not Applicable Default Value 0 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCoEConfiguration.BootOrderFourthFCoETarget (Read or Write) Table 1109. Details of NIC.
Dependency Enable FCoEConfiguration.ConnectFirstFCoETarget NIC.FCoEConfiguration.FirstFCoEFCFVLANID (Read or Write) Table 1111. Details of NIC.FCoEConfiguration.FirstFCoEFCFVLANID attribute Description VLAN ID uses the first FC storage target to connect. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEConfiguration.FirstFCoEWWPNTarget (Read or Write) Table 1112. Details of NIC.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams The following section provides information about the objects in the NIC.FCoEGenParams group. NIC.FCoEGenParams.FCoEBootScanSelection (Read or Write) Table 1114. Details of NIC.FCoEGenParams.FCoEBootScanSelection attribute Description Legal Values Represents the adaptor behavior for starting the system from specified FCoE storage target or fabric discovered target.
Dependency None NIC.FCoEGenParams.FCoEFirstHddTarget (Read or Write) Table 1116. Details of NIC.FCoEGenParams.FCoEFirstHddTarget attribute Description Legal Values Specifies whether the FCoE target is represented as the first HDD to the system. • • Enabled Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams.FCoELnkUpDelayTime (Read or Write) Table 1117. Details of NIC.FCoEGenParams.
License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams.FCoETgtBoot (Read or Write) Table 1119. Details of NIC.FCoEGenParams.FCoETgtBoot attribute Description Legal Values Enables the FCoE initiator to start system to the FCoE target. • • Enabled Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FrmwImgMenu The following section provides information about the objects in the NIC.
NIC.FrmwImgMenu.EFIVersion (Read Only) Table 1121. Details of NIC.FrmwImgMenu.EFIVersion attribute Description Indicates the EFI device driver version information. Legal Values String of up to 8 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FrmwImgMenu.FamilyVersion (Read Only) Table 1122. Details of IC.FrmwImgMenu.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.GlobalBandwidthAllocation.MinBandwidth (Read or Write) Table 1124. Details of NIC.GlobalBandwidthAllocation.MinBandwidth attribute Description Set the minimum percentage of port TX bandwidth allocated to partition. Legal Values Values: 0–100 Default Value 25 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.
NIC.IscsiFirstTgtParams.ConnectFirstTgt (Read or Write) Table 1126. Details of NIC.IscsiFirstTgtParams.ConnectFirstTgt attribute Description Legal Values Enables or disables connecting to the first iSCSI target. • • Enabled Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiFirstTgtParams.FirstTgtBootLun (Read or Write) Table 1127. Details of NIC.
Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiFirstTgtParams.FirstTgtChapPwd (Password) Table 1129. Details of NIC.IscsiFirstTgtParams.FirstTgtChapPwd attribute Description Specifies the first iSCSI storage target Challenge-Handshake Authentication Protocol (CHAP) secret (target CHAP password).
Dependency Not Applicable NIC.IscsiFirstTgtParams.FirstTgtIscsiName (Read or Write) Table 1132. Details of NIC.IscsiFirstTgtParams.FirstTgtIscsiName attribute Description Set the iSCSI Qualified Name (IQN) of the first iSCSI storage target. Legal Values String of upto 223 ASCII characters NOTE: The legal value range may be smaller than the maximum size of 223, based on the vendor configuration of the NIC cards.
• Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiGenParams.ChapMutualAuth (Read or Write) Table 1135. Details of NIC.IscsiGenParams.ChapMutualAuth attribute Description Legal Values Enables or disables mutual CHAP authentication between the iSCSI initiator and target.
NIC.IscsiGenParams.FirstHddTarget (Read or Write) Table 1137. Details of NIC.IscsiGenParams.FirstHddTarget attribute Description Legal Values Enables or disables to check if the iSCSI target appears as the first hard disk drive (HDD) in the system. • • Enabled Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.
Default Value Ipv4 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.IscsiTgtBoot (Read or Write) Table 1140. Details of NIC.IscsiGenParams.IscsiTgtBoot attribute Description Legal Values Specifies whether or not the iSCSI initiator will boot to the specified iSCSI target after connection.
NIC.IscsiGenParams.IscsiVLanId (Read or Write) Table 1142. Details of NIC.IscsiGenParams.IscsiVLanId attribute Description Specifies the VLAN ID for iSCSI boot mode. Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiGenParams.IscsiVLanMode (Read or Write) Table 1143. Details of NIC.IscsiGenParams.
NIC.IscsiGenParams.LunBusyRetryCnt (Read or Write) Table 1145. Details of NIC.IscsiGenParams.LunBusyRetryCnt attribute Description Specifies the number of connection attempts the iSCSI boot initiator will attempt if the iSCSI target LUN is busy. Legal Values Values: 0–60 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.WinHbaBootMode (Read or Write) Table 1148. Details of NIC.IscsiGenParams.WinHbaBootMode attribute Description Legal Values When enabled, it enables iSCSI Offload HBA start mode and disables iSCSI software initiator boot.
NIC.IscsiInitiatorParams.IscsiInitiatorChapPwd (Read or Write) Table 1150. Details of NIC.IscsiInitiatorParams.IscsiInitiatorChapPwd attribute Description Set the iSCSI initiator Challenge-Handshake Authentication Protocol (CHAP) secret (password). Legal Values String of 12–16 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.
NIC.IscsiInitiatorParams.IscsiInitiatorName (Read or Write) Table 1153. Details of NIC.IscsiInitiatorParams.IscsiInitiatorName attribute Description Specifies the initiator iSCSI Qualified Name (IQN). Legal Values String of upto 223 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiInitiatorParams.
NIC.IscsiInitiatorParams.IscsiInitiatorSubnet (Read or Write) Table 1156. Details of NIC.IscsiInitiatorParams.IscsiInitiatorSubnet attribute Description Specifies the IPv4 Subnet Mask of the iSCSI initiator. Legal Values String of 7–15 characters (IPv4 Subnet) Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiInitiatorParams.
NIC.IscsiSecondaryDeviceParams.SecondaryDeviceMacAddr (Read or Write) Table 1158. Details of NIC.IscsiSecondaryDeviceParams.SecondaryDeviceMacAddr attribute Description Specifies the MAC address of a secondary iSCSI boot adapter for redundancy in case if start is unsuccessful. Legal Values String of up to 17 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.
• Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondTgtParams To configure the iSCSIsecond storage, use the objects in this group. NIC.IscsiSecondTgtParams.ConnectSecondTgt (Read or Write) Table 1161. Details of NIC.IscsiSecondTgtParams.ConnectSecondTgt attribute Description Legal Values Enables connecting to the second iSCSI target.
Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondTgtParams.SecondTgtChapId (Read or Write) Table 1163. Details of NIC.IscsiSecondTgtParams.SecondTgtChapId attribute Description Specifies the second iSCSI storage target Challenge-Handshake Authentication Protocol (CHAP) ID Legal Values Values: 0–128. Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondTgtParams.SecondTgtIpVer (Read or Write) Table 1166. Details of NIC.IscsiSecondTgtParams.SecondTgtIpVer attribute Description Legal Values Specifies whether or not IPv4 or IPv4 network address is used for the second iSCSI target.
NIC.IscsiSecondTgtParams.SecondTgtTcpPort (Read or Write) Table 1168. Details of NIC.IscsiSecondTgtParams.SecondTgtTcpPort attribute Description Specifies the TCP Port number of the second iSCSI target. Legal Values Values: 1–65535 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.
Dependency Not Applicable NIC.NICConfig.BootRetryCnt (Read or Write) Table 1171. Details of NIC.NICConfig.BootRetryCnt attribute Description Legal Values Specifies the number of attempts when the start is unsuccessful. • NoRetry • 1Retry • 2Retries • 3Retries • 4Retries • 5Retries • 6Retries • IndefiniteRetries Default Value NoRetry Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICConfig.
NIC.NICConfig.HideSetupPrompt (Read or Write) Table 1173. Details of NIC.NICConfig.HideSetupPrompt attribute Description Legal Values Enables or disables the option ROM setup prompt during Power On Self Test (POST). • Enabled • Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICConfig.LegacyBootProto (Read or Write) Table 1174. Details of NIC.NICConfig.
• • 100 Mbps Half 100 Mbps Full Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.NICConfig.NumberVFAdvertised (Read or Write) Table 1176. Details of NIC.NICConfig.NumberVFAdvertised attribute Description Indicates the number of PCI Virtual Functions advertised on the port when SR-IOV is enabled.
• Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.NICConfig.WakeOnLan (Read or Write) Table 1179. Details of NIC.NICConfig.WakeOnLan attribute Description Legal Values Enables the server to be powered on using an in-band magic packet. • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.NICConfig.
NIC.NICPartitioningConfig To configure the NICPartitioning properties, use the objects in this group. NIC.NICPartitioningConfig.NicPartitioning (Read or Write) Table 1181. Details of NIC.NICPartitioningConfig.NicPartitioning attribute Description Legal Values Enables or disables NIC partitioning for all device ports. • • Enabled Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.NICPartitioningConfig.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICPartitioningConfig.NumberPCIEFunctionsEnabled (Read Only) Table 1184. Details of NIC.NICPartitioningConfig.NumberPCIEFunctionsEnabled attribute Description Indicates the number of physical PCIe functions currently enabled on this port. Legal Values Values: 1–65535 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.
NIC.VndrConfigGroup.BusDeviceFunction (Read Only) Table 1186. Details of NIC.VndrConfigGroup.BusDeviceFunction attribute Description Indicates the BIOS assigned PCIe. Legal Values String of up to 8 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.BlnkLeds (Read or Write) Table 1187. Details of NIC.VndrConfigGroup.
NIC.VndrConfigGroup.EnergyEfficientEthernet (Read Only) Table 1189. Details of NIC.VndrConfigGroup.EnergyEfficientEthernet attribute Description Indicates whether Energy Efficient Ethernet capability is supported. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.DCBXSupport (Read Only) Table 1190. Details of NIC.VndrConfigGroup.
NIC.VndrConfigGroup.FCoEBootSupport (Read Only) Table 1192. Details of NIC.VndrConfigGroup.FCoEBootSupport attribute Description Indicates whether Fibre Channel over Ethernet Boot capability is supported. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.FCoEOffloadMode (Read or Write) Table 1193. Details of NIC.VndrConfigGroup.
Dependency None NIC.VndrConfigGroup.FeatureLicensingSupport (Read Only) Table 1195. Details of NIC.VndrConfigGroup.FeatureLicensingSupport attribute Description Indicates whether Dell Feature Licensing capability is supported. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.FIPMacAddr (Read Only) Table 1196. Details of NIC.VndrConfigGroup.
NIC.VndrConfigGroup.iSCSIBootSupport (Read Only) Table 1198. Details of NIC.VndrConfigGroup.iSCSIBootSupport attribute Description Indicates whether iSCSI Boot capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.ISCSIMacAddr (Read Only) Table 1199. Details of NIC.VndrConfigGroup.
NIC.VndrConfigGroup.iSCSIOffloadSupport (Read Only) Table 1201. Details of NIC.VndrConfigGroup.iSCSIOffloadSupport attribute Description Indicates whether iSCSI Offload capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.LinkStatus (Read Only) Table 1202. Details of NIC.VndrConfigGroup.
NIC.VndrConfigGroup.NicMode (Read or Write) Table 1204. Details of NIC.VndrConfigGroup.NicMode attribute Description Legal Values Enables or disables NIC personality on the port. • • Enabled Disabled Default Value Enabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.NicPartitioningSupport (Read Only) Table 1205. Details of NIC.VndrConfigGroup.
Dependency None NIC.VndrConfigGroup.OnChipThermalSensor (Read Only) Table 1207. Details of NIC.VndrConfigGroup.OnChipThermalSensor attribute Description Indicates whether an on-chip thermal sensor is available. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.OSBMCManagementPassThrough (Read Only) Table 1208. Details of NIC.VndrConfigGroup.
Dependency None NIC.VndrConfigGroup.PXEBootSupport (Read Only) Table 1210. Details of NIC.VndrConfigGroup.PXEBootSupport attribute Description Indicates whether PXE Boot capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.RemotePHY (Read Only) Table 1211. Details of NIC.VndrConfigGroup.
NIC.VndrConfigGroup.TOESupport (Read Only) Table 1213. Details of NIC.VndrConfigGroup.TOESupport attribute Description Indicates whether TCP/IP Offload Engine capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.TXBandwidthControlMaximum (Read Only) Table 1214. Details of NIC.VndrConfigGroup.
Dependency None NIC.VndrConfigGroup.TXFlowControl (Read Only) Table 1216. Details of NIC.VndrConfigGroup.TXFlowControl attribute Description Indicates whether Transmit (TX) Flow Control capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.VirtFIPMacAddr (Read or Write) Table 1217. Details of NIC.VndrConfigGroup.
NIC.VndrConfigGroup.VirtMacAddr (Read or Write) Table 1219. Details of NIC.VndrConfigGroup.VirtMacAddr attribute Description Programmatically assignable MAC address. Programmatic write for support of I/O Identity feature. Legal Values String of up to 17 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.VirtualLinkControl (Read or Write) Table 1220. Details of NIC.VndrConfigGroup.
NIC.VndrConfigGroup.VirtWWPN (Read or Write) Table 1222. Details of NIC.VndrConfigGroup.VirtWWPN attribute Description Programmatically assignable Fibre Channel World Wide Port Name identifier for FCoE. Legal Values String of up to 23 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.WWN (Read Only) Table 1223. Details of NIC.VndrConfigGroup.
Storage.Controller The objects in this group manage storage controller attributes. This group is indexed. The following sections provide information about the objects in this group. Storage.Controller.BackgroundInitializationRate (Read or Write) Table 1225. Details of Storage.Controller.
Default value Normal Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.CheckConsistencyRate (Read or Write) Table 1228. Details of Storage.Controller.CheckConsistencyRate attribute Description The Check Consistency rate is the percentage of the system's resources dedicated to performing a check consistency on a redundant virtual disk.
Default value On Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.CurrentControllerMode (Read Only) Table 1231. Details of Storage.Controller.CurrentControllerMode attribute Description Legal Values Default value Indicates the current personality mode of controllers. • • RAID HBA RAID License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.PatrolReadRate (Read or Write) Table 1234. Details of Storage.Controller.PatrolReadRate attribute Description The Patrol Read Rate is the percentage of the system's resources dedicated to perform Patrol Read. Legal Values Values: 0–100 Default value 30 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.
License Required RACADM Dependency None Storage.Controller.PossibleloadBalancedMode (Read or Write) Table 1237. Details of Storage.Controller.PossibleloadBalancedMode attribute Description Legal Values This attribute represents the ability to automatically use both controller ports connected to the same enclosure to route I/O requests. • • Automatic Disabled Default value Automatic Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.
Storage.Controller.RequestedControllerMode (Read or Write) Table 1240. Details of Storage.Controller.RequestedControllerMode attribute Description Legal Values Modifies the controller mode to RAID or HBA. • • • • None RAID HBA Not Supported Default value Not Applicable Write Privilege Server Control License Required RACADM Dependency None Storage.Controller.SupportControllerBootMode (Read Only) Table 1241. Details of Storage.Controller.
Dependency None Storage.Controller.SupportRAID10UnevenSpans (Read Only) Table 1243. Details of Storage.Controller.SupportRAID10UnevenSpans attribute Description Legal Values This is a read-only attribute. This property indicates if this controller supports uneven spans for RAID 10. • • Supported Not Supported Default value Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.T10PICapability (Read Only) Table 1244.
• • Not Applicable None Default Value UnifiedMode Write Privilege Not Applicable License Required RACADM Dependency Backplane must support. Storage.enclosure.BackplaneRequestedMode (Read or Write) Table 1246. Details of Storage.enclosure.BackplaneRequestedMode attribute Description Legal Values Configures the backplane mode.
The following section provides information about the objects in this group. Storage.PhysicalDisk.BlockSizeInBytes (Read Only) Table 1248. Details of Storage.PhysicalDisk.BlockSizeInBytes attribute Description This is a read-only attribute. This property indicates the logical block size of the physical drive that this virtual disk belongs to.
Storage.PhysicalDisk.T10PICapability (Read Only) Table 1251. Details of Storage.PhysicalDisk.T10PICapability attribute Description Legal Values This is a read-only attribute. This property indicates if this physical disk drive supports T10 PI. • • Incapable Capable Default value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.VirtualDisk The objects in this group manage storage virtual disk attributes. This group is indexed.
Default value Default Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.VirtualDisk.ReadPolicy (Read or Write) Table 1254. Details of the Storage.VirtualDisk.ReadPolicy attribute Description The read policies indicate whether or not the controller must read sequential sectors of the virtual disk when seeking data. NOTE: Storage.VirtualDisk.ReadPolicy attribute is read-only for few PERCs—for example, H330.
Storage.VirtualDisk.WritePolicy (Read or Write) Table 1256. Details of the Storage.VirtualDisk.WritePolicy attribute Description The write policies specify whether or not the controller sends a write-request completion signal as soon as the data is in the cache or after it has been written to disk. NOTE: Storage.VirtualDisk.WritePolicy attribute is read-only for few PERCs—for example, H330.
A Deprecated and New Subcommands Table 1257.
B Legacy and New Groups and Objects Table 1258. Details of legacy groups and objects Legacy Groups and Objects New Groups and Objects idRacInfo iDRAC.Info idRacType Type idRacProductInfo Product idRacDescriptionInfo Description idRacVersionInfo Version idRacBuildInfo Build idRacName Name cfgActiveDirectory iDRAC.
Legacy Groups and Objects New Groups and Objects cfgADDcSRVLookupbyUserdomain DCLookupByUserDomain cfgADDcSRVLookupDomainName DCLookupDomainName cfgADGcSRVLookupEnable GCLookupEnable cfgADGcRootDomain GCRootDomain cfgLanNetworking iDRAC.
Legacy Groups and Objects New Groups and Objects cfgIPv6Gateway Gateway cfgIPv6PrefixLength PrefixLength cfgIPv6AutoConfig AutoConfig cfgIPv6LinkLocalAddress LinkLocalAddress cfgIPv6Address2 Address2 cfgIPv6Address3 Address3 cfgIPv6Address4 Address4 cfgIPv6Address5 Address5 cfgIPv6Address6 Address6 cfgIPv6Address7 Address7 cfgIPv6Address8 Address8 cfgIPv6Address9 Address9 cfgIPv6Address10 Address10 cfgIPv6Address11 Address11 cfgIPv6Address12 Address12 cfgIPv6Address13 Addres
Legacy Groups and Objects New Groups and Objects cfgServerPowerConsumptionClear Max.PowerClear cfgServerPowerCapWatts Cap.Watts cfgServerPowerCapBtuhr Cap.BtuHr cfgServerPowerCapPercent Cap.Percent cfgServerPowerCapEnable Cap.Enable cfgServerPowerLastHourAvg Avg.LastHour cfgServerPowerLastDayAvg Avg.LastDay cfgServerPowerLastWeekAvg Avg.LastWeek cfgServerPowerLastHourMinPower Min.LastHour cfgServerPowerLastHourMinTime Min.LastHour.Timestamp cfgServerPowerLastHourMaxPower Max.
Legacy Groups and Objects New Groups and Objects cfgServerPowerPicEAllocation PCIePowerAllocation cfgServerPowerSupply System.Power.
Legacy Groups and Objects New Groups and Objects cfgRhostsFwUpdateIpAddr FwUpdateIPAddr cfgRhostsFwUpdatePath FwUpdatePath [iDRAC.RemoteHosts] cfgRhostsSmtpServerIpAddr SMTPServerIPAddress cfgEmailAlert iDRAC.EmailAlert cfgEmailAlertIndex NA cfgEmailAlertEnable Enable cfgEmailAlertAddress Address cfgEmailAlertCustomMsg CustomMsg cfgSessionManagement cfgSsnMgtTelnetIdleTimeout iDRAC.Telnet Enable Port Timeout cfgSsnMgtSshIdleTimeout iDRAC.
Legacy Groups and Objects New Groups and Objects Timeout AccessPrivilege cfgSsnMgtWebserverTimeout iDRAC.Webserver Enable HttpPort Timeout HttpsPort LowerEncryptionBitLength [cfgSerial] iDRAC.Serial cfgSerialBaudRate BaudRate cfgSerialConsoleEnable Enable cfgSerialConsoleIdleTimeout IdleTimeout cfgSerialConsoleNoAuth NoAuth cfgSerialConsoleCommand Command cfgSerialHistorySize HistorySize iDRAC.
Legacy Groups and Objects New Groups and Objects cfgNetTuningNicAutoneg iDRAC.Nic [cfgRacTuning] cfgRacTuneRemoteRacadmEnable=1 iDRAC.Racadm cfgRacTuneWebserverEnable=1 iDRAC.Webserver cfgRacTuneHttpPort=80 iDRAC.Webserver cfgRacTuneHttpsPort=443 iDRAC.Webserver cfgRacTuneTelnetPort=23 iDRAC.Telnet cfgRacTuneSshPort=22 iDRAC.SSH cfgRacTuneConRedirEnable=1 iDRAC.VirtualConsole cfgRacTuneConRedirPort=5900 iDRAC.VirtualConsole cfgRacTuneConRedirEncryptEnable=1 iDRAC.
Legacy Groups and Objects New Groups and Objects cfgRacSecurity iDRAC.Security cfgRacSecCsrKeySize CsrKeySize cfgRacSecCsrCommonName CsrCommonName cfgRacSecCsrOrganizationName CsrOrganizationName cfgRacSecCsrOrganizationUnit CsrOrganizationUnit cfgRacSecCsrLocalityName CsrLocalityName cfgRacSecCsrStateName CsrStateName cfgRacSecCsrCountryCode CsrCountryCode cfgRacSecCsrEmailAddr CsrEmailAddr cfgRacVirtual iDRAC.
Legacy Groups and Objects New Groups and Objects cfgLdapRoleGroupPrivilege Privilege cfgStandardSchema iDRAC.ADGroup cfgSSADRoleGroupIndex NA cfgSSADRoleGroupName Name cfgSSADRoleGroupDomain Domain cfgSSADRoleGroupPrivilege Privilege cfgIpmiSerial iDRAC.
Legacy Groups and Objects New Groups and Objects cfgIpmiPetCommunityName CommunityName cfgUserDomain iDRAC.UserDomain cfgUserDomainIndex NA cfgUserDomainName Name cfgSmartCard iDRAC.SmartCard cfgSmartCardLogonEnable SmartCardLogonEnable cfgSmartCardCRLEnable SmartCardCRLEnable [cfgIPv6URL] cfgIPv6URLString NA cfgVFlashSD iDRAC.
Legacy Groups and Objects New Groups and Objects cfgServerFirstBootDevice FirstBootDevice cfgLogging iDRAC.Logging cfgLoggingSELOEMEventFilterEnable SELOEMEventFilterEnable iDRAC.SNMP.Alert cfgIpmiPetAlertEnable Enable cfgIpmiPetAlertDestIpAddr DestAddr cfgSSADRoleGroupPrivilege (Read or Write) Table 1259. Details of cfgSSADRoleGroupPrivilege Description Use the bit mask numbers listed in the table below to set role-based authority privileges for a Role Group.