RACADM Command Line Reference Guide for iDRAC7 1.55.55 and CMC 4.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 Introduction................................................................................................................................11 New in This Release............................................................................................................................................... 11 Supported RACADM Interfaces..............................................................................................................................11 RACADM Syntax Usage.................
feature.....................................................................................................................................................................40 featurecard............................................................................................................................................................. 41 frontpanelerror......................................................................................................................................................
ping6..................................................................................................................................................................... 102 racdump................................................................................................................................................................102 racreset..............................................................................................................................................................
Displayable Characters........................................................................................................................................ 145 idRacInfo...............................................................................................................................................................146 cfgLanNetworking................................................................................................................................................
cfgVFlashPartition.................................................................................................................................................240 cfgLogging............................................................................................................................................................ 242 cfgRacSecurity.....................................................................................................................................................
iDRAC.serverboot................................................................................................................................................. 317 iDRAC.ServiceModule.......................................................................................................................................... 318 iDRAC.SmartCard..................................................................................................................................................320 iDRAC.SNMP.........
NIC.IscsiSecondTgtParams..................................................................................................................................408 NIC.NICConfig.......................................................................................................................................................409 NIC.NICPartitioningConfig.................................................................................................................................... 411 NIC.VndrConfigGroup.....
Introduction 1 This document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object definitions for the following: • iDRAC Enterprise or Express for Blade Servers • iDRAC Enterprise or Express on Rack and Tower Servers • Dell Chassis System (CMC) NOTE: In this version of RACADM, the Linux shell features such as ctrl+d, home, del, and end shortcut keys are not supported. New in This Release For iDRAC version 1.55.
Local RACADM racadm getconfig -g [-o ] [-i ] racadm Example racadm getconfig -g idracinfo racadm getsysinfo SSH or Telnet RACADM racadm getconfig -g [-o ] [-i ] racadm Example racadm getconfig -g idracinfo racadm getsysinfo Remote RACADM racadm -r -u -p getconfig -g [-o ] [-i ] racadm -r -u -p
VLanMode WakeOnLan • = Disabled = Disabled To display a single attribute for the specified group, run: racadm get device... Example racadm get nic.nicconfig.3.legacybootproto [Key=NIC.Integrated.1-3#NICConfig] Legacybootproto=PXE RACADM Command Options The following table lists the options for the RACADM command: Option -r -r : Description Specifies the controller’s remote IP address.
Using The Autocomplete Feature Use the autocomplete feature to: • Display all the available RACADM commands in the alphabetical order on pressing the key at the prompt. • To complete the list, enter the starting letter of the command at the prompt and press key. NOTE: This feature is applicable only for iDRAC.
setled setniccfg sshpkauth sslcertview sslcertdelete sslcsrgen sslEncryptionStrength sslkeyupload sslresetcfg swinventory systemconfig testemail testtrap testalert traceroute traceroute6 update usercertview vflashsd vflashpartition vmdisconnect cd quit • Example 2:[root@idrac-]racadm> get get getconfig getled getniccfg getraclog getractime getsel getsensorinfo getssninfo getsvctag getsysinfo gettracelog getuscversion getversion • Example 3: [root@idrac-]racadm> getv
Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers Telnet/SSH/ Local Remote Serial RACADM RACADM Telnet/SSH/ Serial Local Remote Telnet/SSH/ Remote RACADM RACADM Serial RACADM arp Yes Yes Yes Yes Yes Yes Yes Yes chassisaction No No No No No No Yes Yes clearasrscreen Yes Yes Yes Yes Yes Yes No No clearpending Yes Yes Yes Yes Yes Yes No No closessn Yes Yes Yes Yes Yes Yes Yes Yes clrraclog No No No No No No Yes Yes clrsel Yes Yes Ye
Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMC Telnet/SSH/ Local Remote Serial RACADM RACADM Telnet/SSH/ Serial Local Remote Telnet/SSH/ Remote RACADM RACADM Serial RACADM getkvminfo No No No No No No Yes Yes getled Yes Yes Yes Yes Yes Yes Yes Yes getmacaddress No No No No No No Yes Yes getmodinfo No No No No No No Yes Yes getniccfg Yes Yes Yes Yes Yes Yes Yes Yes getpbinfo No No No No No No Yes Yes getpminfo No No No No
Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers Telnet/SSH/ Local Remote Serial RACADM RACADM Telnet/SSH/ Serial Local Remote Telnet/SSH/ Remote RACADM RACADM Serial RACADM ping6 Yes Yes Yes Yes Yes Yes Yes Yes racdump Yes No Yes Yes Yes Yes Yes Yes racreset Yes Yes Yes Yes Yes Yes Yes Yes racresetcfg Yes Yes Yes Yes Yes Yes Yes Yes raid Yes Yes Yes Yes Yes Yes Yes Yes remoteimage Yes Yes Yes Yes Yes Yes Yes Yes rollback Yes Yes
Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMC Telnet/SSH/ Local Remote Serial RACADM RACADM Telnet/SSH/ Serial Local Remote Telnet/SSH/ Remote RACADM RACADM Serial RACADM testtrap Yes Yes Yes Yes Yes Yes Yes Yes testalert Yes Yes Yes Yes Yes Yes No No traceroute Yes Yes Yes Yes Yes Yes Yes Yes traceroute6 Yes Yes Yes Yes Yes Yes Yes Yes update Yes Yes Yes Yes Yes Yes No No usercertupload No Yes Yes No Yes Yes No No usercert
• For more information about IOM network settings, see the Dell PowerConnect M6220 Switch Important Information document and the Dell PowerConnect 6220 Series Port Aggregator White Paper. Updates are sometimes included with the system to describe changes to the system, software, and/or documentation. Always read the updates first because they often supersede information in other documents. See the Safety and Regulatory information that is shipped with your system.
3. Verify your country or region in the Choose a Country/Region drop-down menu at the top of page. 4. Select the appropriate service or support link based on your need.
RACADM Subcommand Details 2 This section provides detailed description of the RACADM subcommands including the syntax and valid entries.
For using single quotation marks: • • No character escaping is necessary. A single quotation mark is not used even with a back slash escaped. NOTE: An empty string may be specified as either ” “(using double quotation marks) or ' '(using single quotation marks). "?"and "?" Description Displays all the subcommands you can use with the RACADM command and a one-line description about each subcommand. ? followed by displays the syntax for the specified command.
getkvminfo -- display the KVM module information getled -- display the LED settings on a module getmacaddress -- get MAC/WWN addresses getmodinfo -- get module configuration and status information getniccfg -- display network settings for modules getpbinfo -- get power budget status information getpminfo -- get power management status information getraclog -- display the CMC log getractime -- display the current CMC time getredundancymode -- gets the redundancy mode of the CMC getsel -- display records from
-4 : show CMC IPv4 information -6 : show CMC IPv6 information help and help Description Lists all the subcommands available for use with RACADM and provides a short description about each subcommand. You may also type a subcommand, group, object or Fully Qualified Descriptor (FQDD) name after help.
IP Address HW Type Flags HW Address Mask Device 192.168.1.1 0x1 0x2 00:00:0C: 07:AC:0F * eth0 autoupdatescheduler Description You can automatically update the platform of the devices on the server. This subcommand is applicable only for iDRAC. To run this subcommand, you must have the Server Control privilege. NOTE: • • • • • • Synopsis The autoupdatescheduler subcommand can be enabled or disabled. Lifecycle Controller and CSIOR may not be enabled to run this subcommand.
• • • • • • • -pp — Specifies the FTP proxy password. -po — Specifies the FTP proxy port. -pt — Specifies the FTP proxy type. -time — Specifies the time to schedule an autoupdate in the HH:MM format. This option must be specified. -dom — Specifies the day of month to schedule an autoupdate. Valid values are 1–28, L (Last day) or '*' (default — any day). -wom — Specifies the week of month to schedule an autoupdate. Valid values are 1–4, L (Last week) or '*' (default — any week).
time repeat applyreboot idracuser – = = = = 14:30dayofmonth =1 5 1 racuser To clear and display AutoUpdateScheduler parameter: racadm autoupdatescheduler clear Successfully cleared the Automatic Update (autoupdate) feature settings cd Description To change the current working object, use this command. Synopsis racadm> cd
chassisaction Description Executes a power action on the chassis, iKVM or a server. This subcommand is applicable only for CMC. To use this subcommand, you must have the Chassis Control Administrator privilege. Synopsis racadm chassisaction [-m ] Input • -m — Module on which you want to carry out the action. Values are: • —chassis — is the default value if -m is not specified. —switch-n where n=1–6 —kvm • — Action that you want to execute on the specified module.
clearpending Description Deletes the pending values of all the attributes (objects) in the device (NIC, BIOS, and Storage). This command is applicable only for iDRAC. NOTE: If any attribute is not modified or a job is already scheduled for the same device, then the pending state is not cleared or deleted. Synopsis racadm clearpending Input values are: • • • BIOS.Setup.1-1 NIC.Integrated.1-1 RAID.Integrated.
clrraclog Description Deletes the CMC log. This subcommand is applicable only for CMC. Synopsis racadm clrraclog Input racadm clrraclog clrsel Description Removes all the existing records from the System Event Log (SEL). To use this subcommand, you must have Clear Logs permission. Synopsis racadm clrsel cmcchangeover Description Changes the state of the CMC from active to standby, or from standby to active, in a redundant CMC configuration.
For CMC only: racadm config -g -o [-m ] Input NOTE: The -f and -p options are not supported for the Serial/Telnet/SSH console. • • • • • • • • -f — The -f option causes config to read the contents of the file specified by and configure iDRAC. The file must contain data in the format specified in the section Parsing Rules in the iDRAC User’s Guide available at www.dell.com/esmmanuals. -continue — This option is used with -f option only.
For CMC only: • To configure the single property of a group: racadm config -g cfgSerial -o cfgSerialBaudRate • To modify a user password: racadm config -g cfgUserAdmin -o cfgUserAdminPassword -i 3 newpassword • To configure the single property of a group for a particular server: racadm config -g cfgSessionManagement -o cfgSsnMgtWebServerTimeout newvalue -m server-n • To configure the remote Syslog property for a particular server: racadm config -g cfgRemoteHosts -o cfgRhostsSyslogEnable 1 -m server-n
For more information about clearing the coredump, see the coredumpdelete subcommand. Synopsis racadm coredump Input None Output None Example • racadm coredump No Core Dump Data is available.
where must be a number between 0 and 128. racadm deploy-m server - -u root -p -d [-6] racadm deploy -m switch- -u root -p racadm deploy -m switch- -v SNMPv2 ro racadm deploy -a [server/switch] -u root -p racadm deploy -q [-n ] Input • —b — Specifies the first boot device must be used with -o. Use with-m to specify for an individual server, or with an -a for all servers.
Example • Set root password, configure static IPV4 address, set first boot device to HDD, and enable boot once for server-1. racadm deploy -m server-1 -s 192.168.0.20 255.255.255.0 192.168.0.1 HDD -o yes • Set root password, configure static IPV6 address, set first boot device to HDD, and enable boot once for server-1. racadm deploy -m server-1 -s 192.168.0.11 255.255.255.0 192.168.0.1 HDD -o yes • Set root password and enable DHCP for server-3.
• • -p — Specifies the password of the remote share to import the file. -r — Specifies the reboot type. The type can be one of the following: • – pwrcycle — Power cycle – Graceful — Graceful reboot without forced shutdown – Forced — Graceful reboot with forced shutdown -s — Specifies the start time for the scheduled job in yyyymmddhhmmss format. The default value TIME_NOW starts the job immediately.
• • • • Updates Audit Config Worknotes Valid Severity values are: • • • Critical Warning Info Valid examples of alert descriptors are: Input • • • • • idrac.alert.all idrac.alert.audit idrac.alert.audit.lic idrac.alert.audit.warning idrac.alert.audit.lic.critical • • • • • get — Displays the list of eventfilter settings. set — Configures the actions and notifications for a given eventfilter configuration. -i — Message ID for which the simulation is needed.
• Configure using severity as a parameter. For example, all informational events in storage category are assigned power off as action, and email and snmp as notifications: racadm eventfilters set -c idrac.alert.storage.info -a poweroff -n email,snmp • Configure using subcategory as a parameter. For example, all configurations under the licensing subcategory in the audit category are assigned power off as action and all notifications are enabled: racadm eventfilters set -c idrac.alert.audit.
NOTE: To deactivate FlexAddress features, the chassis must be turned off. Synopsis racadm feature -s racadm feature -d -c racadm feature -a -c ExtendedStorage racadm feature -1 -c ExtendedStorage racadm feature -2 -c ExtendedStorage racadm feature -r -c ExtendedStorage Input -s –Displays the status of active features. -d –Deactivates feature specified in -c option.
Output • • • • • Example No feature card inserted — Action: To verify that the SD card was properly inserted, check the CMC. In a redundant CMC configuration, make sure the CMC with the SD feature card installed is the active CMC and not the standby CMC. The feature card inserted is valid and contains the following feature(s) FlexAddress: The feature card is bound to this chassis — Action: No action required. No features active on the chassis — Action: Install the SD card into the CMC.
only be a single update operation in progress at any time. In addition, the fwupdate subcommand may only update one or more devices of a single kind at a time. To use this subcommand for CMC, you must have the Chassis Configuration Administrator privilege and for iDRAC you must have Configure iDRAC permission. NOTE: • • Running the fwupdate subcommand to update the firmware on the active CMC resets itself and all the network connections are dropped.
Input • • —u — For iDRAC: The update option performs a checksum of the firmware update file and starts the actual update process. This option may be used along with the —g or —p options. At the end of the update, iDRAC performs a soft reset. For CMC: Performs the firmware update operation. —s — For iDRAC: This option returns the status of the update process. Use this option by itself. Lists active SD card features and SD card status. For CMC: Displays the status of the firmware update.
NOTE: iDRAC7 targets are not supported from CMC. To update the iDRAC7 targets, use the CMC GUI. CMC version 3.00 accepts IPv4, IPv6 or fully qualified domain names (FQDN) for both FTP and TFTP servers. NOTE: You can specify the cmc-active and cmc-standby modules at the same time along with one or more server-n modules. This option enables the devices to be updated together. This option is applicable only for CMC.
To block the firmware downgrade on 3000W AC power supply configuration. racadm fwupdate –s Ready for firmware update racadm fwupdate –g –u –a 10.210.138.121 –d firming-4.40-A00.cmc –m cmc-active Firmware update has been initiated. This update process may take several minutes to complete. racadm fwupdate –s Cannot update local CMC firmware: The uploaded firmware image does not support the installed power supplies. NOTE: Firmware update from local RACADM (using -p -u -d options) is not supported on linux OS.
For the --clone and --replace options, check the Job ID by running the racadm jobqueue view command. For more information, see jobqueue. Synopsis racadm get -f racadm get .... racadm get . racadm get .. racadm get ...
NOTE: For --clone and --replace options, only .xml file template is received. These options --clone and --replace cannot be used in the same command. Examples • Get system LCD information. racadm get system.lcd LCDUserString=test • Display an entire group, in this case the topology configuration. racadm get system.location • Display a single object from a particular group. racadm get system.location.rack.name • Display an indexed group. racadm get system.power.supply.
• • • • • • cmc-n — where n=1, 2 fan-n — where n=1–9 ps-n — where n=1–6 chassis kvm lcd NOTE: A few of the informational messages are applicable for more than one module. To avoid repetition of the same message for different modules, only one such informational message is displayed for the default command racadm getactiveerrors. When an -m option is used on another server or switch, the informational message is displayed, if applicable.
• To display entire information log. racadm getactiveerrors -s info Module ID = server-1 Severity = Critical Message = A fabric mismatch deteceted for mezzanine card B1. Module ID = ps-1 Severity = Critical Message = The power input for power supply 1 is lost. Module ID = ps-3 Severity = Critical Message = The power input for power supply 3 is lost. Module ID = cmc-1 Severity = NonCritical Message = A firmware or software incompatibilty detected between system BIOS in slot 4 and CMC.
To run this subcommand, you must have the CMC Login User privilege. Synopsis racadm getassettag [-m ] Input -m — Specifies the module whose asset tag you want to view. Legal value: chassis Example • • racadm getassettag -m chassis racadm getassettag chassis 78373839–33 getchassisname Description Displays the name of the chassis. This subcommand is applicable only for CMC. To run this subcommand, you must have the CMC Login User privilege.
• • • • maximum number of indexes a particular group supports. If -i is not specified, then a value of 1 is assumed for groups, which are tables that have multiple entries. The -i option enters the index value and not a named value -o — The -o or object option specifies the object name that is used in the query. This option is optional and can be used with the -g option. -u — The-u or user name option, is used to display the configuration for the specified user.
getdcinfo Description Displays general I/O module and daughter card configuration information. Only the CMC controls daughter cards. This subcommand is applicable only for CMC. To run this subcommand, you must have the CMC Login User privilege. NOTE: Fabric verification for server DCs is performed only when the chassis is turned on. When the chassis is on standby power, iDRACs on the server modules remain turned off and thus are unable to report the server's DC fabric type.
server-7 Not Present None N/A None N/A server-8 Present FibreChannel Invalid 4 None N/A server-9 Extension(1) None N/A None N/A server-10 Not Present None N/A None N/A server-11 Not Present None N/A None N/A server-12 Not Present None N/A None N/A server-13 Not Present None N/A None N/A server-14 Not Present None N/A None N/A server-15 Not Present None N/A None N/A server-16 Not Present None N/A None N/A getdcinfo -n
getflexaddr Description Displays enabled/disabled status for the entire chassis. If used with the -i option, the command displays MACs/WWN on a per slot basis. This subcommand is applicable only for CMC. To run this subcommand, you must have the CMC Login User privilege. NOTE: If FlexAddress is not activated on the chassis, the command displays server-assigned MAC/WWN addresses. If the slot is empty, the command enters blank in the server-assigned MAC/WWN addresses.
16 Enabled Not Present idrac System Disabled Display the current flex address setting for slot 1.
Example racadm getfanreqinfo [Ambient Temperature Fan Request %] 38 [Server Module Fan Request Table] 1 SLOT-01 PowerEdgeM60 ON 0 Present 33 2 SLOT-02 PowerEdgeM90 ON 5 Present 35 3 SLOT-03 PowerEdgeM71 ON 0 Present 44 4 SLOT-04 PowerEdgeM61 ON 0 Present 46 5 SLOT-05 PowerEdgeM61 ON 0 Present 46 6 SLOT-06 Not Present N/A 7 SLOT-07 PowerEdgeM60 ON 5 Present 100 8 SLOT-08 PowerEdgeM7 10 ON Pr
1 SLOT-01 PowerEdgeM60 ON 0 Present 33 2 SLOT-02 PowerEdgeM90 ON 5 Present 35 3 SLOT-03 PowerEdgeM71 ON 0 Present 44 4 SLOT-04 PowerEdgeM61 ON 0 Present 46 5 SLOT-05 PowerEdgeM61 ON 0 Present 46 6 SLOT-06 Not Present N/A 7 SLOT-07 PowerEdgeM60 ON 5 Present 100 8 SLOT-08 PowerEdgeM7 10 ON Present 44 9 SLOT-09 N/A N/A Not Present N/A 10 SLOT-10 N/A Extension(2) N/A N/A 11 SLOT-1
Switch-4 N/A None Not Present N/A Switch-5 N/A None Not Present N/A Switch-6 N/A None Not Present N/A Display Enhanced Cooling Mode status. racadm getfanreqinfo [Enhanced Cooling Mode] Enhanced Cooling Mode(ECM) Status = Disabled getioinfo Description Displays general information about the I/O modules on the chassis. This subcommand is applicable only for CMC. To run this subcommand, you must have the CMC Login User privilege.
• JP4BF2S Switch-1 A1 Present Master N/A N/A JP4BF2S Switch-2 A2 Present Master N/A N/A JP4BF2S Switch-3 B1 Present Master N/A N/A JP4BF2S Switch-4 B2 Present Master N/A N/A JP4BF2S Switch-5 C1 Present Master N/A N/A JP4BF2S Switch-6 C2 Present Master N/A N/A racadm getioinfo -m switch-1 • Switch-1 Dell Ethernet PassThrough Gigabit Ether
getled Description Displays the LED settings on a module: blinking, not blinking, or unknown (for empty slots). To run this subcommand, you must have the Login User privilege. Synopsis racadm getled -m Input For CMC: -m — Specifies the module whose LED settings you want to view.
• • -x — Displays the extra MACs (Ethernet or iSCSI) for servers with extra LOM MACs and must be used with -m option. -a — Displays the Ethernet and iSCSI MAC/WWN addresses for all iDRAC/LOMs/mezzanine cards. When FlexAddress is enabled for a particular slot, then the chassis-assigned MAC/WWN address is displayed. Example Display iSCSI MAC addresses for all servers. racadm getmacaddress -t iscsi Display iSCSI MAC for server-1.
Server-5 Present 14:FE:B5:00:F0 :B4 14:FE:B5:00:F0 :B5 14:FE:B5:00:F0 :B7 Server-6 Not Present Not Installed Not Installed Not Installed Server-7 Present 14:FE:B5:00:F0 :CE 14:FE:B5:00:F0 :CF 14:FE:B5:00:F0 :D2 Server-8 Not Present Not Installed Not Installed Not Installed Server-9 Present 14:FE:B5:00:F0 :E8 14:FE:B5:00:F0 :E9 14:FE:B5:00:F0 :EA Server-10 Extension(2) Not Installed 14:FE:B5:00:F0 :F6 14:FE:B5:00:F0 :F8 Server-11 Not Present Not Installed Not Installed Not I
Gigabit Ethernet Present 14:FE:B5:00: 14:FE:B5:00: F0:83 F0:84 Gigabit Ethernet Present 14:FE:B5:00: 14:FE:B5:00: F0:85 F0:86 Gigabit Ethernet Present 14:FE:B5:00: 14:FE:B5:00: F0:87 F0:88 Gigabit Ethernet Present 14:FE:B5:00: 14:FE:B5:00: F0:89 F0:8B Gigabit Ethernet Present 14:FE:B5:00: 14:FE:B5:00: F0:8A F0:8C Gigabit Ethernet Present 14:FE:B5:00: 14:FE:B5:00: 14:FE:B5:00: F0:8D F0:8E F0:90 iSCSI Present 00:26:B9:FE: 00:26:B9:FE: 38:CD 38:CF 10 GbE XAUI Present 14:FE:B5:00: 14:FE:B
iSCSI Present 00:21:9B:FE: 00:21:9B:FE: 39:C1 39:C3 Gigabit Ethernet Present 14:FE:B5:00: 14:FE:B5:00: F0:B9 F0:BB iSCSI Present 00:10:18:49: 00:10:18:49: EF:19 EF:1B 10 GbE XAUI +KR Present 14:FE:B5:00: 14:FE:B5:00: F0:BD F0:BF FCoE-FIP Present 00:1B: 21:74:01:99 FCoE-WWN Present 20:01:00:1B: 20:01:00:1B: 21:74:01:99 21:74:01:9B Server-6 Not Installed Not Present Not Installed Server-7-A 10 GbE KR Present 14:FE:B5:00: 14:FE:B5:00: 14:FE:B5:00: F0:CE F0:CF F0:D2 iSCSI Present 00:
Server-9-A Gigabit Ethernet Present 14:FE:B5:00: 14:FE:B5:00: 14:FE:B5:00: F0:E8 F0:E9 F0:EA Gigabit Ethernet Present 14:FE:B5:00: 14:FE:B5:00: F0:EB F0:EC Gigabit Ethernet Present 14:FE:B5:00: 14:FE:B5:00: 14:FE:B5:00: F0:E8 F0:E9 F0:EA Gigabit Ethernet Present 14:FE:B5:00: 14:FE:B5:00: F0:EB F0:EC 10 GbE XAUI Present 14:FE:B5:00: 14:FE:B5:00: F0:ED F0:EF 10 GbE XAUI Present 14:FE:B5:00: 14:FE:B5:00: F0:EE F0:F0 Gigabit Ethernet Extension(2) Not Installed 14:FE:B5:00: 14:FE:B5:00: F0:F
Server-14 Not Installed Not Present Not Installed Not Installed Not Installed Server-15 Not Installed Not Present Not Installed Not Installed Not Installed Server-16 Not Installed Not Present Not Installed Not Installed Not Installed Switch-1 10 GbE KR Present Not Installed 00:1E:C9:CC: Not BB:52 Installed Switch-2 10 GbE KR Present Not Installed 5C: Not 26:0A:B9:FD: Installed ED Switch-3 10 GbE XAUI Present Not Installed 00:00:00:00: Not 00:00 Installed Switch-4 10 GbE XAUI
– • fpc-cable -A — Suppresses headers and labels in the output.
Server-6 Present ON OK 1234567 Server-7 Present ON OK Server-8 Not Present N/A N/A N/A Server-9 Not Present N/A N/A N/A Server-10 Extension(2) N/A N/A N/A Server-11 Not Present N/A N/A N/A Server-12 Present ON OK Server-13 Not Present N/A N/A N/A Server-14 Present ON OK 0000015 Server-15 Present ON OK Server-16 Present ON OK KVM Present ON OK IO-Cable Present ON OK ABC1234 FPC-Cable Present ON OK ABC1234 NOTE: For CMC only, a power state of "P
IPv4 settings: NIC Enabled = 1 IPv4 Enabled = 1 DHCP Enabled = 1 IP Address = 10.35.0.64 Subnet Mask = 255.255.255.0 Gateway = 10.35.0.
getpbinfo Description Displays power budget status information. This subcommand is applicable only for CMC. To run this subcommand, you must have the CMC Login User privilege.
2 SLOT-02 OFF 0 W 5 PowerEdgeM80 5 3 SLOT-03 ON 164 W 5 N/A 4 SLOT-04 ON 155 W 5 5 SLOT-05 ON 180 W 5 6 SLOT-06 ON 180 W 5 7 SLOT-07 ON 170 W 5 8 SLOT-08 N/A N/A 5 N/A 9 SLOT-09 N/A N/A 5 N/A 10 SLOT-10 Extension(2) N/A 5 N/A 11 SLOT-11 N/A N/A 5 N/A 12 SLOT-12 ON 125 W 5 PowerEdgeM60 0 13 SLOT-13 N/A N/A 5 N/A 14 SLOT-14 ON 342 W 5 N/A 15 SLOT-15 ON 140 W 5 16 SLOT-16 ON 125 W 5 PowerEdgeM60 0 N/A NOTE: Extended Power Perf
System Potential Power = 68 W (188 BTU/hr) System Input Current Reading = 31.2 A [Real-Time Energy Statistics] System Energy Consumption = 6.4 kWh System Energy Consumption Start Time = 16:02:10 01/16/2008 System Energy Consumption Timestamp = 16:02:10 01/16/2008 [System Power Status] Chassis Power State = ON Overall Power Health = OK Redundancy = No getraclog Description The getraclog command displays RAC or CMC log entries.
Example • Display the starting record and the number of records. racadm getraclog -s 10 -c 2 • Display a few records and prompt to display another set of records. $ racadm getraclog --more Dec 4 22:23:09 CMC-JP4BF2S Login success from 10.94.46.52 (username=root, type=SSH, sid=16393) Dec 4 22:24:54 CMC-JP4BF2S Login success from 10.94.46.52 (username=test, type=SSH, sid=35885) Dec 4 22:26:20 CMC-JP4BF2S Login success from 10.94.46.
getredundancymode Description Displays the redundancy status (Redundant or Non-Redundant) of the CMC. This subcommand is applicable only for CMC. To run this subcommand, you must have the CMC Login User privilege. Synopsis racadm getredundancymode Example racadm getredundancymode Redundant getsel Description Displays all sensor event log entries in the DRAC.
NOTE: For Dell PowerEdge FX2 chassis with FM120x4 server, the power related information is not displayed.
System Board Inlet Temp Ok 22 C -7 C 47 C System Board Exhaust Temp Ok 25 C 3 C 75 C CPU1 Temp Unknown NA NA NA Sensor Type : FAN System Board Fan1A RPM Ok 6240 RPM 720 RPM NA System Board Fan2A RPM Ok 6240 RPM 720 RPM NA System Board Fan3A RPM Ok 6360 RPM 720 RPM NA System Board Fan4A RPM Ok 6360 RPM 720 RPM NA System Board Fan5A RPM Ok 6360 RPM 720 RPM NA System Board Fan
System Board 3.3V PG Ok Good NA NA System Board 5V PG Ok Good NA NA CPU1 PLL PG Ok Good NA NA System Board 1.1V PG Ok Good NA NA CPU1 M23 VDDQ PG Ok Good NA NA CPU1 M23 VTT PG Ok Good NA NA System Board FETDRV PG Ok Good NA NA CPU1 VSA PG Ok Good NA NA CPU1 M01 VDDQ PG Ok Good NA NA System Board NDC PG Ok Good NA NA CPU1 VTT PG Ok Good NA NA System Board 1.
CPU2 Status N/A Absent NA NA Sensor Type : MEMORY DIMM SLOT A2 N/A Absent NA NA DIMM SLOT A3 N/A Absent NA NA DIMM SLOT A1 Ok Presence Detected NA NA DIMM SLOT A4 N/A Absent NA NA DIMM SLOT A5 N/A Absent NA NA DIMM SLOT A6 N/A Absent NA NA DIMM SLOT A7 N/A Absent NA NA DIMM SLOT A8 N/A Absent NA NA DIMM SLOT A9 N/A Absent NA NA DIMM SLOT A10 N/A Absent NA NA DIMM SLOT A11 N/A Absent NA NA DIMM SLOT A12
System Board Power Optimized Ok Not Degraded NA NA Sensor Type : INTRUSION System Board Intrusion Closed Power ON System Board Fan Redundancy Full Redundant Fan System Board PS Redundancy Disabled PSU Sensor Type : REDUNDANCY Sensor Type : SD CARD vFlash Active getslotname Description Displays the name and host name (if available) of all 16 slots, or
5 6 7 8 9 10 11 12 13 14 15 16 SLOT-05 SLOT-06 SLOT-07 SLOT-08 SLOT-09 SLOT-10 SLOT-11 SLOT-12 SLOT-13 SLOT-14 SLOT-15 SLOT-16 racadm getslotname -i 1 Webserver-1 getssninfo Description Displays a list of users that are connected to iDRAC.
getsvctag Description Displays the Service Tag of the host system. Synopsis racadm getsvctag Input getsvctag Output Y76TP0G Example racadm getsvctag getsysinfo Description Displays information related to iDRAC, CMC, managed system, and watchdog configuration. NOTE: The local racadm getsysinfo subcommand on Linux displays the Prefix Length on separate lines for IPv6 Address 2 — IPv6 Address 15 and the Link Local Address.
Current DNS Domain Domain Name from DHCP = = Disabled IPv4 settings: Enabled Current IP Address Current IP Gateway Current IP Netmask DHCP Enabled Current DNS Server 1 Current DNS Server 2 DNS Servers from DHCP = = = = = = = = 1 10.94.136.108 10.94.136.1 255.255.255.0 1 0.0.0.0 0.0.0.
Examples • racadm getsysinfo -A -s ""System Information:" "PowerEdge R520" "I" "1.5.0" "H1VGF2S" "37118600020" "" "" "" "ON" "Fresh Air Capable:" "Yes" "Embedded NIC MAC Addresses:" "90:B1:1C:11:3C:B5" "90:B1:1C:11:3C:B5" "90:B1:1C:11:3C:B6" "90:B1:1C: 11:3C:B6" • racadm getsysinfo -w -s System Information: System Model System Revision System BIOS Version Service Tag Express Svc Code Host Name OS Name OS Version Power Status Fresh Air Capable = = = = = = = = = = PowerEdge R520 I 1.5.
Example Record: 1 Date/Time: Dec Source: ssnmgrd[175] 8 08:21:30 Description: root from 143.166.157.103: session timeout sid 0be0aef4 getversion Description Displays the current software version, model and generation information, and whether the target device can be updated. To use this subcommand, you must have a login user privilege.
server-1 1.40.40 (Build 08) PowerEdge M520 iDRAC7 Y server-2 3.50 (Build 2) PowerEdgeM610x iDRAC6 Y server-4 3.50 (Build 4) PowerEdgeM710H D iDRAC6 racadm getversion -c server-1 1.0.5 PowerEdgeM520 server-2 1.0.3 PowerEdgeM610x server-4 1.0.0 PowerEdgeM710HD server-5 1.0.3 PowerEdgeM710 server-7 1.0.6 PowerEdgeM620 server-9 1.0.
server-7 1.7.1 PowerEdgeM620 server-9 1.7.1 PowerEdgeM520 switch-1 MXL 10/40GbE X01 9-2(0-296) switch-2 M8024-k 10GbE SW A00 switch-3 Dell PowerConnect M8024 X00 switch-4 Dell PowerConnect M8024 X00 switch-5 Dell PowerConnect M6348 X02 switch-6 Dell PowerConnect M6220 A01 5.0.1.3 racadm getversion -l -m server-1 server-1 BIOS 1.6.0 2013-01-09 iDRAC1.40.40 1.40.
NIC-Broadcom Gigabit Ethernet BCM5720 - BC:30:5B: 97:06:C6 7.6.6 Rollback NIC-Broadcom Gigabit Ethernet BCM5720 - BC:30:5B: 97:06:C6 7.6.12 Reinstall NIC-Broadcom Gigabit Ethernet BCM5720 - BC:30:5B: 97:06:C6 7.6.12 2013-04-02 NIC-PERC S110 Controller 3.0.0-0139 RAID-PERC H310 Mini 20.10.1-0084 2012-10-11 Reinstall RAID-PERC H310 Mini 20.10.1-0084 Reinstall RAID-PERC H310 Mini 20.10.1-0084 2012-02-09 BP12G+ 0:1 0.
• • • -u — Username of the remote share to where the file must be exported. Specify user name in a domain as domain/username -p — Password for the remote share to where the file must be exported. -l — Network share location to where the Hardware Inventory must be exported. Examples To view all the NIC devices on managed server: [SH7757 ~]$ racadm hwinventory NIC NIC FQDD "NIC.Slot.5-2-1" Available NIC FQDD "NIC.Slot.5-2-2" Available NIC FQDD "NIC.Slot.5-2-3" Available NIC FQDD "NIC.Slot.
iScsi Offload Mode: reserved: 0 0x00 To export the inventory to a remote CIFS share: racadm hwinventory export -f Myinventory.xml -u admin -p mypass -l //1.2.3.4/share To export the inventory to a remote NFS share: racadm hwinventory export -f Myinventory.xml -u admin -p mypass -l 1.2.3.4:/share To export the inventory to local file system using local Racadm: racadm hwinventory export -f Myinventory.xml To display the Standard hardware inventory verbose description for the FC.Slot.
Device Name: 2001000E1E091075 WWN: VirtWWN: WWPN: VirtWWPN: Chip Type: Family Version: EFI Version: OS Driver Version: First FC Target WWPN: First FC Target LUN: Second FC Target WWPN: Second FC Target LUN: Hard Zone Address: Hard Zone Enable: FC Tape Enable: Loop reset Delay: Frame Payload Size : Fabric Login Retry Count: Fabric Login Timeout: Port Login Retry Count: Port Login Timeout: Port Down Retry Count: Port Down Timeout: Link Down Timeout: Port Number: Port Speed: Max Number of IOs per connection su
collisions:0 txqueuelen:1000 RX bytes:272532097 (259.9 MiB) TX bytes:0 (0.0 B) inlettemphistory Description Exports the inlet temperature history data file. The file can be exported to a remote file share, local file system, or the management station. Displays the average and the peak temperatures during the last hour, day, week, month, or year. This subcommand is applicable only for iDRAC. NOTE: For FM120x4 systems, this subcommand provides the historical data for system board temperature.
Average Temperatures Last Hour = 23C ( 73.4F Last Day = 24C ( 75.2F Last Week = 24C ( 77.0F Last Month = 25C ( 77.0F Last Year = 23C ( 73.4F ) ) ) ) ) Peak Last Last Last Last Last ) ) ) ) ) Temperatures Hour = 23C ( Day = 25C ( Week = 27C ( Month = 29C ( Year = 29C ( 73.4F 77.0F 80.6F 84.2F 84.
• Delete a specific Job from the Current JobQueue. racadm jobqueue delete -i • Create a Job for the provided FQDD and add to the job queue. racadm jobqueue create [-r ] [-s ] [-e ] racadm jobqueue create NIC.Integrated.1-1 -r pwrcycle s TIME_NOW -e 20120501100000 krbkeytabupload Description Uploads a Kerberos keytab file to CMC. This subcommand is applicable only for CMC. To run this subcommand, you must have the Configure iDRAC permission.
-b -q
• • • • • -e — Displays events that have occurred before this time. The time format is yyyy-mm-dd HH:MM:SS. The time stamp must be provided within double quotation marks. -f — Specifies the file location and name where lifecycle log is exported. -a — Specifies the FTP Server IP address or FQDN, user name, and password. -d — Specifies the path to the file on the FTP server.
• Display the iDRAC agent idrac records, under the storage category and storage physical disk drive subcategory, with severity set to warning. racadm lclog view -a idrac -c storage -b pdr -s warning • Display the records under storage and system categories with severities set to warning or critical. racadm lclog view -c storage,system -s warning,critical • Display the records having severities set to warning or critical, starting from sequence number 4.
This subcommand is applicable only for iDRAC.
Transaction ID License Description License Type Entitlement ID License Bound Expiration = = = = = = 5 iDRAC7 Enterprise License PERPETUAL Q3XJmvoxZdJVSuZemDehlcrd H1VGF2S Not Applicable • Import a new license to a specific device in a known location. $racadm license import -f license.xml -l //shareip/sharename -u -p -c idrac.embedded.1 • Import a license from a CIFS share to a device, in this case Embedded iDRAC. racadm license import -u admin -p passwd -f License.
• Replace a license on a device with a license file on an NFS share using transaction ID. In this case, transaction 27. racadm license replace -f License.xml -l 192.168.2.140:/licshare -t 27 • Replace a license on a device with a license file on a CIFS share using transaction ID. In this case, transaction 27. racadm license replace -u admin -p passwd -f License.xml -l //192.168.2.140/licshare -t 27 netstat Description Displays the routing table and the current connections.
tcp 0 0 10.94.161.12 10.94.115.23 ESTABLISHED 0:22 7:45106 tcp 0 0 127.0.0.1:52 127.0.0.1:19 ESTABLISHED 174 9 tcp 0 0 127.0.0.1:52 127.0.0.1:81 ESTABLISHED 887 95 nicstatistics Description Displays the statistics for the NIC FQDD. FQDD maps to the NIC object keys which RACADM uses while calling the Data Manager APIs NIC objects. This subcommand is applicable only for iDRAC. Synopsis • racadm nicstatistics • racadm nicstatistics • racadm hwinventory NIC.Integrated.
For iDRAC, you must have the Execute Diagnostic Commands permission. Synopsis racadm ping Input racadm ping 10.94.161.161 Output PING 10.94.161.161 (10.94.161.161): 56 data bytes64 bytes from 10.94.161.161: seq=0 ttl=64 time=4.121 ms--- 10.94.161.161 ping statistics ---1 packets transmitted, 1 packets received, 0 percent packet lossround-trip min/avg/max = 4.121/4.121/4.
• • • • • Output NIC information (CMC module) — getniccfg Redundancy information — getredundancymode Trace log information — gettracelog RAC event log — getraclog System event log — getsel The following information is displayed when the racdump subcommand is processed: • • • • • General system/RAC information Coredump Session information Process information Firmware build information Example racadm racdump =============================================================================== General System/RAC
=============================================================================== Sensor Information =============================================================================== FanSpeed 1 Fan-1 OK 14495 rpm FanSpeed 2 Fan-2 OK 14505 rpm FanSpeed 3 Fan-3 OK 4839 rpm FanSpeed 4 Fan-4 OK 14527 rpm FanSpeed 5 Fan-5 OK 14505 rpm FanSpeed 6 Fan-6 OK 4835 rpm FanSpeed 7 Fan-7 OK 14521 rpm FanSpeed 8 Fan-8 Not OK 1 rpm FanSpeed 9 Fan-9 OK 4826 rpm
For CMC only: • -m — The values must be one of the following: – – server–n: where n=1–16 server–nx: where n=1–8; x = a–d (lower case) NOTE: – – Multiple modules may be specified, such as -m -m . -f option is used to force the reset and is available only with an -m option. Output racadm racreset RAC reset operation initiated successfully. It may take up to a minute for the RAC to come online again. Example For iDRAC only: • iDRAC reset.
NOTE: There is a 100 percent fan request when the command is issued against the servers. Synopsis • racadm racresetcfg RAC reset operation initiated successfully. It may take a few\n minutes for the RAC to come online again. Input • For iDRAC only: racadm racresetcfg -f • For CMC only: racadm racresetcfg [-m ] For CMC: • -m — Specifies the device to reset the configuration on .
To run this subcommand, you must have the Configure iDRAC permission. Synopsis • racadm raid • To generate and view information about the inventory of storage root node. racadm raid get status • To generate and view information about the inventory of controllers. racadm raid get controllers -o racadm raid get controllers -o -p • To generate and view information about the inventory of batteries.
• To generate and view information about the inventory of fans. racadm raid get fans --refkey racadm raid get fans --refkey -o racadm raid get fans --refkey -o -p • To generate and view information about the inventory of EMMs.
• To reset, clear, and import the RAID configuration to the controller. racadm raid importconfig: racadm raid resetconfig: racadm raid clearconfig: Input • • • • • • • • • -o — Specifies the optimized version. -p — Specifies the property name. --refkey — Specifies the controller or enclosure FQDDs. -rl — Sets the RAID level.
• • • -assign {yes | no} — Assigns or unassigns the disk as a hot-spare. -type { ghs | dhs} — Assigns a global or dedicated hot-spare. -vdkey: — Assigns the dedicated hot-spare to the specified virtual disk. This option is required for dedicated hot-spare. Example • To generate and view information about the inventory of controllers, virtual disks, storage enclosures, and physical disk drives. – To generate and view information about the inventory of storage root node.
SupportEnhancedAutoForeignImport EnhancedAutoImportForeignConfig SupportControllerBootMode ControllerBootMode = = = = Supported Disabled Supported User Mode This command displays the filtered property values for all returned controller objects. racadm raid get controllers -o -p Name RAID.Integrated.1-1 Name = PERC H710P Adapter (Embedded) This command displays the operations pending on the controller. – racadm raid get -pending Raid.Integrated.1-1 Raid.Slot.
BayId FirmwareVersion SasAddress SlotCount = = = = 1 0.0C 0x5C8CA0A0EB118A00 24 This command displays all enclosure keys connected to the connectors. racadm raid get enclosures --refkey RAID.Integrated.1-1 Enclosure.Internal.0-1:RAID.Integrated.1-1 This command is an optimized and filtered version. racadm raid get enclosures --refkey RAID.Integrated.1-1 -o -p Name Enclosure.Internal.0-1:RAID.Integrated.
This command displays all physical disk drive keys connected to the enclosures. racadm raid get pdisks --refkey RAID.Integrated.1-1 Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1 This command is an optimized version and displays all disk objects for the enclosure FQDD. racadm raid get pdisks --refkey Enclosure.Internal.0-1:RAID.Integrated. 1-1 -o racadm raid get pdisks -o Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.
This command returns all the EMM keys connected to the enclosures. racadm raid get emms -refkey This command is an optimized version and displays all the EMM objects for the enclosure FQDD. racadm raid get emms --refkey -o This command is an optimized and filtered version.
– This command assigns or unassign a global or dedicated hot-spare. racadm raid hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated. 1-1 -assign no racadm raid hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated. 1-1 -assign yes -type ghs racadm raid hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated. 1-1 -assign yes -type dhs -vdkey:Disk.Virtual.0:RAID.Integrated.1-1 • To reset, clear, and import the RAID configuration to the controller.
• Disable Remote File Sharing. racadm remoteimage -d Disable Remote File Started. Please check status using -s option to know Remote File Share is ENABLED or DISABLED. • Check Remote File Share status. racadm remoteimage -s - status Remote File Share is Enabled UserName Password ShareName //10.94.161.112/xxxx/dtk_3.3_73_Linux.iso • Deploy a remote image on iDRAC CIFS Share. racadm remoteimage -c -u root -p calvin -l //192.168.0.180/dev/ floppy.img • Deploy a remote image on iDRAC NFS Share.
• – server–n: where n=1–16 – server–nx: where n=1–8; x=a–d (enter lower case letter only) -a — Performs power action on all servers. Not allowed with the powerstatus action. NOTE: The -m and -a options are applicable only to CMC platforms. • — Specifies the action. The options for the string are: – – hardreset — Performs a reset (reboot) operation on the managed system. powercycle — Performs a power-cycle operation on the managed system.
• Get Power Status of blade 16 on CMC. racadm serveraction -m server-16 powerstatus ON • Reseat blade 2 on CMC. racadm serveraction -m server-2 reseat -f Server power operation successful • Turn off the server 16 from CMC. racadm serveraction -m server-16 powerdown Server power operation successful set Description To set the value of configuration objects on a device and modify the RAC object values, run this command. This subcommand is applicable only for iDRAC.
• • • • NOTE: To import or export .xml config files, Lifecycle Controller version 1.1 or later is required. -b — Specifies the type of shutdown for the host after the import operation completes. The parameters are Graceful for graceful and Forced for forced shutdown. If this parameter is not specified, graceful shutdown is taken as the default. NOTE: If the operating system is in use, then the graceful shutdown option may time out within 300 seconds.
setarraycfg Description This command is applicable only for CMC. To configure storage array properties, run this command. Synopsis racadm setarraycfg -m module –n -e 0|1 -g [] [-f A|B] racadm setarraycfg -f A|B NOTE: The valid value for -m is server–n, where n=1–16.
Example • Set member name, member IP, member netmask, member gateway with new group name, group IP, group password, admin password selecting fabric A on server-1. racadm setarraycfg -m server-1 -n cmc-col 192.168.1.233 255.255.255.0 192.168.1.0 -e 0 -g cmcarray-grp 192.168.1.10 -f A • Set member name, member IP, member netmask, member gateway with existing group name, group IP, group password selecting fabric B on server-1. racadm setarraycfg -m server-1 -n cmc-col 192.168.1.233 255.255.255.
To run this subcommand, you must have the Chassis Configuration Administrator privilege. If the fabric type is determined to be InfiniBand, the operation is canceled and the command returns an error. If the FlexAddress feature is not activated, the command returns an error. NOTE: The server must be turned off to change the slot state. All servers must be turned off to change the fabric state. The MAC/WWN addresses must be managed locally (not by an external console) to run this command.
– chassis This option is applicable for CMC only. • -l — Specifies whether the LED must blink. can be one of the following: – – Example 0: no blinking 1: blinking For CMC: • racadm setled -m server-1 -1 1 LED state was set successfully. • racadm setled -m server-9 -1 1 ERROR: Server in slot 9 is an extension of the server in slot 1. NOTE: The setled command generates an error when run on the extension slot of a multi-slot server.
Input • • • -d — Enables DHCP for the NIC (default is DHCP disabled.) -d6 — Enables AutoConfig for the NIC. It is enabled by default. -s — Enables static IP settings. The IPv4 address, netmask, and gateway must be specified. Otherwise, the existing static settings are used. , , and must be typed as dot-separated strings. racadm setniccfg -s 192.168.0.120 255.255.255.0 192.168.0.1 • -s6 — Enables static IPv6 settings.
• Removal of VLAN configuration from a switch. racadm setniccfg -m switch-1 -v setractime Description Sets the date and time on the CMC. To run this subcommand, you must have the Administrator privilege. This command is applicable only for CMC. Synopsis racadm setractime -d racadm setractime -l racadm setractime -z ?||* Input • -d — Sets the time in the string YYYYMMDDhhmmss.
Setting the time using the -l and -z options are recommended. This command format allows the CMC to support local time zones. This command includes the ability to automatically adjust the CMC time to the local Daylight Savings Time. Example The setractime subcommand supports dates ranging from 1/1/1970 00:00:00 through 12/31/2030 23:59:59. To set the local time to November 24, 2012 at 3:02:30 pm. racadm setractime -l 20121124150230 The time was set successfully.
Example racadm setsysinfo -c chassisname "Dell Rack System" The chassis name was set successfully. sshpkauth Description Enables you to upload and manage up to 4 different SSH public keys per user. You can upload a key file or key text, view keys, or delete keys. This command has three mutually exclusive modes determined by the options — upload, view, and delete. Upload The upload mode allows you to upload a keyfile or to copy the key text on the command line.
• Upload a valid key to iDRAC User 2 in the first key space using a file. $ racadm sshpkauth -i 2 -k 1 -f pkkey.key • Get all keys for User 2 on iDRAC. $ racadm sshpkauth -v -i 2 -k all Key file successfully uploaded.
For CMC only: racadm sslcertupload -f -t Input • -t — Specifies the type of certificate to upload. The type of certificate must be: • • – 1 — server certificate (CMC only) – 2 — Active directory (CMC only) – 3 — Public Key Cryptography Standards (PKCS) format (iDRAC only) – 5 — Kerberos Keytab (CMC only) – 6 — Server certificate and key (CMC only) -f — Specifies the source filename in the local file system of the certificate uploaded.
NOTE: For CMC: For self-signed certificate, the common name includes PQDN (Partially qualified domain name) or FQDN (Fully qualified domain name). Output racadm sslcertview -t 1 Serial Number 01 Subject Information: Country Code (CC) US State (S) Texas Locality (L) Round Rock Organizati on (O) Dell Inc.
racadm sslcertview -t 1 -A 00 US Texas Round Rock Dell Inc. Remote Access Group iDRAC7 default certificate US Texas Round Rock Dell Inc. Remote Access Group iDRAC7 default certificate Jun 7 23:54:19 2011 GMT Jun 4 23:54:19 2021 GMT sslcertdelete Description Command to delete a custom signing certificate from iDRAC. To run this subcommand, you must have the administrator permission. Synopsis racadm sslcertdelete -t Input -t — Specifies the type of certificate to delete.
Input • • • -g — Generates a new CSR. -s — Returns the status of a CSR generation process (generation in progress, active, or none). -f — Specifies the filename of the location, , where the CSR is downloaded. NOTE: If the -f option is not specified, the filename defaults to sslcsr in your current directory. Output If no options are specified, a CSR is generated and downloaded to the local file system as sslcsr by default.
Example $ racadm sslresetcfg Certificate generated successfully and webserver restarted. NOTE: For more information about managing SSL certificates, see the “Securing CMC Communications Using SSL and Digital Certificates” section in the Dell Chassis Management Controller User Guide. swinventory Description Displays the list of software objects and associated properties installed on a server. This subcommand is applicable only for iDRAC.
NOTE: • • • • • • Synopsis To run this subcommand, you require the Server Profile Export and Import license. Backup operation is licensed but restore operation is not licensed (Enterprise). If Lifecycle Controller is ‘disabled’, then the attempt to start a restore operation is unsuccessful. If CSIOR is disabled, then the system inventory may not be current during the backup operation. An appropriate warning message is displayed. The autobackupscheduler can be enabled or disabled.
NOTE: The -dom, -wom, or -dow option must be included in the command for the autoupdate schedule. The * value for the options must be included within ' ' (single quotation mark). • • • • • • If the -dom option is specified, then the -wom and -dom options are not required. If the-wom option is specified, then the-dow is required and -dom is not required. If the-dom option is non-'*', then the schedule repeats by month. If the-wom option is non-'*', then the schedule repeats by month.
– AutoBackup system to NFS share and encrypt the data. racadm systemconfig backup -f image.img -l 192.168.2.140:/ share -u admin -p passwd -n encryptpasswd123 -time 14:30 dom 1 -rp 6 -mb 20 – AutoBackup system to vFlash SD. racadm systemconfig backup --vFlash -time 10:30 -wom 1 -dow mon -rp 6 -mb 1 testemail Description Sends a test email from iDRAC to a specified destination. Prior to running the test email command, make sure that the SMTP server is configured.
Input • -f — options are: • • • – – – -u -p -d AD — Test AD using simple authentication ADKRB — Test AD using Kerberos authentication LDAP — Test Generic LDAP — On the basis of a feature, is user or user@domain. — Password for the user.
Example Commands for the cfgIpmiPet group: • Enable the alert. racadm config -g cfgIpmiPet -o cfgIpmiPetAlertEnable -i 1 • Set the destination email IP address. racadm config -g cfgIpmiPet -o cfgIpmiPetAlertDestIpAddr -i 1 192.168.0.110 • View the current test trap settings. racadm getconfig -g cfgIpmiPet -i where is a number from 1 to 4 testalert Description Tests FQDN supported SNMP trap notifications. To run this subcommand, you must have the Test Alert User Access.
traceroute6 Description Traces the network path of routers as the packets traverse from the system to a destination IPv6 address. To run this subcommand for CMC, you must have the Administrator privilege. For iDRAC, you must have the Execute Diagnostic Commands permission. Synopsis racadm traceroute6 racadm traceroute fd01::1 Output traceroute to fd01::1 (fd01::1) from fd01::3, 30 hops max, 16 byte packets 1 fd01::1 (fd01::1) 14.324 ms 0.26 ms 0.
• • • • • • • • • • • • For update from repository .xml files are allowed. If a file name is not specified for repository update, then the Catalog.xml is taken as default. -u — Specifies user name of the remote share that stores the update file. Specify user name in a domain as domain or username. -p — Specifies password of the remote share that stores the update file. -l — Specifies network share location that stores the update file.
• Upload the update file from a remote NFS share. racadm update -f -l 1.2.3.4:/share • Upload the update file from the local file system using Local RACADM. racadm update -f • Perform update from a CIFS repository and to apply the updates, reboot the server. racadm update -f Catalog.xml -l //192.168.11.10/Repo -u test -p passwd -a TRUE -t CIFS • Generate a comparison report using the available updates in the repository. racadm update -f Catalog.xml -l 192.168.11.
usercertview Description Displays the user certificate or user CA certificate that exists on iDRAC. This subcommand is applicable only for iDRAC. Synopsis racadm usercertview -t [-A] -i Input • • • Output -t — Specifies the type of certificate to view, either the user certificate or the user CA certificate. – 1=user certificate – 2=user CA certificate -A — Prevents printing headers or labels. -i — Index number of the user. Valid values are 1–16.
NOTE: • • To run this subcommand, you must have the iDRAC7 Enterprise license. After iDRAC restart, the status of the previous operation performed on the partition(s) is erased. Synopsis racadm vflashpartition -i -o
NOTE: – – • This feature is not supported in Local RACADM. Creating vFlash partition from an image file on the CFS or NFS IPv6 enabled network share is not supported. Delete a partition. racadm vflashpartition delete -i 1 • Status of operation on partition 1. racadm vflashpartition status -i 1 • Status of all the existing partitions. racadm vflashpartition status -a • List all the existing partitions and its properties.
iDRAC and CMC Property Database Group and Object Descriptions 3 The iDRAC and CMC property database contains the configuration information for iDRAC and CMC. Associated object is organizing data, and object group is organizing object. The IDs for the groups and objects that the property database supports are listed in this section for iDRAC Enterprise on Blade Servers, iDRAC Enterprise or Express on Rack and Tower Servers and CMC.
Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMC cfgRacSecurity No No Yes cfgRacVirtual Yes Yes No cfgServerInfo No Yes Yes cfgActiveDirectory Yes Yes Yes cfgLDAP Yes Yes Yes cfgLdapRoleGroup Yes Yes Yes cfgStandardSchema Yes Yes Yes cfgChassisPower No No Yes cfgIpmiSol Yes Yes No cfgIpmiLan Yes Yes No cfgIpmiPetIpv6 Yes Yes No cfgIpmiPef Yes Yes No cfgIpmiPet Yes Yes No cfgUserDomain Yes Yes No cfgServerPower Yes Yes No cf
The following sections provide information about the objects in the idRACInfo group. idRacProductInfo (Read Only) Description A text string that identifies the product. Legal Values A string of up to 63 ASCII characters. Default for iDRAC iDRAC – Integrated Dell Remote Access Controller Default for CMC Chassis Management Controller idRacDescriptionInfo (Read Only) Description A text description of the RAC type. Legal Values A string of up to 255 ASCII characters.
iDRAC Type (Read Only) Description Identifies the remote access controller type.
cfgNicIPv4Enable (Read or Write) Description Enables or disables iDRAC or CMC IPv4 stack. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgNicSelection (Read or Write) Description Specifies the current mode of operation for the RAC network interface controller (NIC). The table below describes the supported modes. This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers or CMC.
NOTE: For iDRAC Enterprise on Blade Servers, this object enables or disables the VLAN capabilities of iDRAC from CMC. Read only for iDRAC on Blade servers. iDRAC displays only the current VLAN settings and you cannot modify the settings from iDRAC. All chassis management traffic, including the CMC and all iDRACs, resides on this external VLAN when enabled. No iDRAC configuration change is required to use this external management network VLAN.
Default 0 For CMC, this property is used only if cfgNicUseDhcp is set to 1(true), or if both cfgIPv6Enable and cfgIPv6AutoConfig are set to 1(true).
NOTE: For IPv6, only the DHCPv6 address or static address is registered. Example: racadm getconfig -g cfgLanNetworking cfgNicEnable=1 cfgNicIPv4Enable=1 cfgNicIpAddress=192.168.22.101 cfgNicNetmask=255.255.255.0 cfgNicGateway=192.168.22.101 cfgNicUseDhcp=1 # cfgNicMacAddress=00:00:00:00:00:01 cfgNicVLanEnable=0 cfgNicVLanID=1 cfgNicVLanPriority=0 cfgDNSServersFromDHCP=1 cfgDNSServer1=192.168.0.5 cfgDNSServer2=192.168.0.6 cfgDNSRacName=cmc-frankly cfgDNSDomainName=fwad.
cfgDNSServer2 (Read or Write) Description Retrieves the IPv4 address for DNS server 2. This parameter is only valid if cfgDNSServersFromDHCP is set to 0 (FALSE). NOTE: cfgDNSServer1 and cfgDNSServer2 may be set to identical values while swapping addresses. Legal Values String representing a valid IPv4 address. For example: 192.168.0.20. Default 0.0.0.0 cfgNicEnable (Read or Write) Description Enables or disablesiDRAC or CMC network interface controller.
cfgNicGateway (Read or Write) Description iDRAC or CMC gateway IPv4 address. The gateway IPv4 address used for static assignment of the RAC IP address. This property is only valid if cfgNicUseDhcp is set to0(FALSE). NOTE: This parameter is only configurable if the cfgNicUseDhcp parameter is set to 0 (FALSE). Legal Values String representing a valid gateway IPv4 address. For example: 192.168.0.1. Default 192.168.0.
cfgNicStaticIPv4Enable (Read or Write) Description Enables or disables the IPv4 stack. Legal Values • • Default 1 — Enabled 0 — Disabled 1 — Enabled NOTE: If this object is modified, then the object cfgNicIPv4Enable is also modified. cfgNicStaticIpAddress (Read or Write) Description Returns or sets the current IPv4 address. NOTE: Only set the current IPv4 address if cfgNicUseDhcp is set to 0(false). Legal Values Any Valid IPv4 address Default 192.168.0.
cfgDNSStaticServersFromDHCP (Read or Write) Description Specifies the DNS server static IP addresses. Legal Values • • Default 0 DNS Addresses are configured on the Device DNS Addresses are assigned via DHCP cfgDNSStaticServer1 (Read or Write) Description Specifies the IP address for DNS server 1. NOTE: This property is only valid if cfgDNSServersFromDHCP is set to 0 (FALSE). Legal Values • • Default 0 — Do not use DHCP 0 — IP Address, subnet mask and gateway are configured on the device.
cfgRemoteHosts This group provides properties that allow configuration of the SMTP server for email alerts. For CMC, this group enables/disables and configures firmware updates, NTP, remote syslogging and SMTP email alerting. To apply this setting to iDRAC, use the —m option. Use this object with the config or getconfig subcommands. To use this object property for CMC, you must have the Chassis Configuration Administrator privilege.
cfgRhostsNtpEnable Description Enables or disables the use of the Network Time Protocol (NTP) for date and time synchronization. This object is applicable only for CMC. Legal Values • • Default 0 1 (true) 0 (false) cfgRhostsNtpServer1 Description Specifies the first of three possible NTP servers. This object is applicable only for CMC. Legal Values A string representing a valid NTP server. For example, ntp1.ntp.net. At least one NTP server must be specified and duplicate entries are not allowed.
cfgRhostsSyslogEnable (Read or Write) Description To allow the RAC and SEL logs to be written to up to three remote syslog servers Enables or disables remote syslog. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgRhostsSyslogPort (Read or Write) Description Remote syslog port number to use for writing the RAC and SEL logs to a remote syslog server. For CMC, this setting takes effect only if the cfgRhostsSyslogEnable parameter is set to 1(enabled).
Default cfgRhostsSyslogPowerLoggingEnabled Description To remote syslog servers, Enables or disables power consumption logging. This object is applicable only for CMC. NOTE: Remote syslog must be enabled and more than one remote syslog servers must be configured to log the power consumption. Legal Values • • Default 0 1 (enabled) 0 (disabled) cfgRhostsSyslogPowerLoggingInterval Description Specifies the power consumption collection/logging interval. This object is applicable only for CMC.
NOTE: In the current CMC firmware version, the objects cfgUserAdminEnable and cfgUserAdminPrivilege are interrelated; changing the value of one property causes the value of the other property to change. For example, if a user does not have login privilege, the user is disabled by default. When you enable the user by changing the value of the UserAdminEnable to 1, the right-most digit of the UserAdminPrivilege also becomes 1.
Example racadm getconfig -g cfgUserAdmin -i 1 # cfgUserAdminIndex=1 cfgUserAdminEnable=1 cfgUserAdminUserName=root # cfgUserAdminPassword=******** (Write-Only) cfgUserAdminPrivilege=0x00000fff The following table lists the bit masks for user privileges.
Fabric A Administrator 0x0000200 Fabric B Administrator 0x0000400 Fabric C Administrator 0x0000800 Examples The following table provides sample privilege bit masks for users with one or more privileges. User Privileges Privilege Bit Mask The user is not allowed to access iDRAC or CMC. 0x00000000 The user may 0x00000001 only log in to iDRAC or CMC and view iDRAC or CMC and server configuration information. The user may log in to iDRAC or CMC and change configuration.
Default ******** cfgUserAdminEnable (Read or Write) Description Enables or disables an individual user. NOTE: You can enable a user for a given index, only if you set the password for the same user. Legal Values • • 1 (TRUE) 0(FALSE) Default • • For iDRAC: 1 (User 2), 0 (All others) For CMC: 0 cfgUserAdminSolEnable (Read or Write) Description Enables or disables Serial Over LAN (SOL) user access for the user. This object property is specific to iDRAC.
The following sections provide information about the objects in the cfgEmailAlert group. cfgEmailAlertIndex (Read Only) Description The unique index of an alert instance. Legal Values 1–4 Default cfgEmailAlertEnable (Read or Write) Description Enables or disables the alert instance. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgEmailAlertAddress (Read or Write) Description Specifies the destination email address for email alerts, for example, user1@company.com.
cfgSessionManagement This group contains parameters to configure the number of sessions that can connect to iDRAC. One instance of the group is allowed. Displays current settings for and configures the idle timeout properties for web server, Telnet, SSH and RACADM sessions. Changes to idle timeout settings take effect at the next login. To disable the idle timeout property for a connection, set this property to 0.
• • If there is iDRAC on Rack and Tower Servers: Connection timed out If there is iDRAC Enterprise on Blade Servers: Session timed out. Closing the session. After the message is displayed, the system returns to the shell that generated the Secure Shell session. Legal Values • • 0 —(No timeout) 60–10800 NOTE: If 0 (no timeout), the network connection does not send alive packets to probe the client. Otherwise, keep alive packets are sent to guarantee that the client is responding.
cfgSerialBaudRate (Read or Write) Description Sets the baud rate on iDRAC or CMC serial port. Legal Values • • For iDRAC: 9600, 28800, 57600, 115200 For CMC: 2400, 4800, 9600, 19200, 28800, 38400, 57600,115200 Default • • For iDRAC: 57600 For CMC: 115200 cfgSerialConsoleEnable (Read or Write) Description Enables or disables the RAC or CMC serial console interface.
Default: • • For iDRAC: \ For CMC: ^\ NOTE: For more information about running the RACADM commands for special characters, see Guidelines to Quote Strings Containing Special Characters cfgSerialConsoleIdleTimeout (Read or Write) Description The maximum number of seconds to wait before an idle serial session is disconnected.
cfgSerialHistorySize (Read or Write) Description Specifies the maximum size of the serial history buffer. Legal Values 0–8192 Default 8192 cfgSerialCom2RedirEnable (Read or Write) Description Enables or disables the console for COM 2-port redirection. The cfgSerialCom2RedirEnable object property is applicable only for iDRAC on Rack and Tower Servers. It is not applicable for iDRAC Enterprise on Blade Servers and CMC.
cfgOobSnmp This group contains parameters to configure the SNMP agent and trap capabilities of iDRAC or CMC. One instance of the group is allowed. The CMC SNMP agent supports the standard RFC1213 mib-2 and the Dell enterprise-specific the MIB. This group is not applicable for iDRAC on Rack and Tower Servers. For CMC, use this object with the config or getconfig subcommands. To use this object property for CMC, you must have the Chassis Configuration Administrator privilege.
cfgTrapsIndex (Read Only) Description Indicates the unique index of an alert instance. Legal Values 1–4 Default 1 cfgTrapsEnable Description Enables or disables event traps on the CMC. Legal Values • • Default None 1 (TRUE) 0 (FALSE) cfgTrapsAlertDestIpAddr Description Sets the IP address that receives the alert. Legal Values A string representing a valid IP address. For example, 192.168.0.20.
The following sections provide information about the objects in the cfgRacTuning group. NOTE: For CMC, only the following objects are displayed, if —m option is used: • cfgRacTuneRemoteRacadmEnable • cfgRacTuneWebserverEnable • cfgRacTuneHttpPort • cfgRacTuneHttpsPort • cfgRacTuneTelnetPort • cfgRacTuneSshPort cfgRacTuneConRedirPort (Read or Write) Description To use for keyboard, mouse, video and Virtual Media traffic to iDRAC, specify the port. This object is applicable only to iDRAC.
cfgRacTuneHttpPort (Read or Write) Description To use HTTP network communication with either iDRAC or CMC, specify the port number. Legal Values 10–65535 NOTE: For CMC, the following port numbers are reserved and cannot be used: 21, 68, 69, 123, 161, 546, 801, 4096, 5988, 5989, 6900, 9000, 60106. Default 80 cfgRacTuneHttpsPort (Read or Write) Description To use HTTPS network communication with either iDRAC or CMC, specify the port number.
• cfgRacTuneIpRanbeMask bit-wise and with cfgRacTuneIpRangeAddr Legal Values An IPv4 address formatted string, for example, 255.255.255.0. Default 255.255.255.0 cfgRacTuneIpBlkEnable (Read or Write) Description Enables or disables the IPv4 address blocking feature of iDRAC or CMC.
• Default 0 — Disabled 1 — Enabled cfgRacTuneUserBlkEnable Description Blocks the login for maximum of 5 minutes after 5 unsuccessful login attempts. The login using any interface such as WSMAN or GUI is blocked after 5 unsuccessful attempts NOTE: This is applicable only to configure the user privilege. Legal Values • • Default 0 — Disabled 1 — Enabled 0 — Disabled cfgRacTuneSshPort (Read or Write) Description Specifies the port number used either for iDRAC or CMC SSH interface.
cfgRacTuneConRedirEncryptEnable (Read or Write) Description Encrypts the video in a Virtual Console session. This object property is applicable only to iDRAC. Legal Values • • Default 1 1 (TRUE) 0 (FALSE) cfgRacTuneAsrEnable (Read or Write) Description Enables or disables iDRAC last crash screen capture feature. This object property is applicable only to iDRAC and requires an iDRAC reset before it becomes active.
cfgRacTuneTimezoneOffset (Read Only) Description Specifies the time zone offset (in minutes) from Greenwich Mean Time (GMT) / Coordinated Universal Time (UTC) to use for the RAC Time. Some common time zone offsets for time zones in the United States are: • • • • –480 (PST — Pacific Standard Time) –420 (MST — Mountain Standard Time) –360 (CST — Central Standard Time) –300 (EST — Eastern Standard Time) For CMC: This object property is read only.
This object property is applicable only to iDRAC. Legal Values • • Default 0 0 (TRUE-Enables) 1 (FALSE-Disables) cfgRacTuneWebserverEnable (Read or Write) Description Enables or disables iDRAC or CMC web server. If this property is disabled, iDRAC or CMC is not accessible using client web browsers. This property has no effect on the Telnet/SSH or racadm interfaces.
ifcRacManagedNodeOs This group contains properties that describe the managed server operating system. One instance of the group is allowed. This object is applicable only for iDRAC. The following sections provide information about the objects in the ifcRacManagedNodeOs. ifcRacMnOsHostname (Read Only) Description The host name of the managed server. Legal Values A string of up to 255 characters. Default ifcRacMnOsOsName (Read Only) Description The operating system name of the managed server.
If this property is enabled when the host server is rebooted, this feature attempts to start from the virtual media devices — if the appropriate media is installed in the device. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgVirMediaFloppyEmulation (Read or Write) Description When set to 0, the virtual floppy drive is recognized as a removable disk by Windows operating systems. Windows operating systems assigns a drive letter that is C: or higher during enumeration.
cfgServerInfoIndex (Read Only) Description Displays the index name of the server. This object is applicable only to CMC. Legal Values None Default None cfgServerSlotNumber (Read Only) Description Specifies the location of the specified server (1–16) in the chassis. This object is applicable only to CMC. Legal Values None Default None cfgServerServiceTag (Read Only) Description Displays the service tag of the specified server. This object is applicable only to CMC.
Default None cfgServerBmcMacAddress (Read Only) Description Displays the BMC MAC address of the specified server. This object is applicable only to CMC. Legal Values None Default None cfgServerNic1MacAddress (Read Only) Description Displays the MAC address of the server NIC 1. This object is applicable only to CMC. Legal Values None Default None cfgServerNic2MacAddress (Read Only) Description Displays the MAC address of the server NIC 2. This object is applicable only to CMC.
This object is applicable only to CMC. Legal Values 1–9 in descending priority, where 1 holds the highest priority Default 1 cfgServerNicEnable (Read/Write) Description Enables or disables LAN channel. This object is applicable only to CMC. Legal Values • • Default None 1 — (Enable) 0 — (Disable) cfgServerIPMIOverLanEnable (Read/ or Write) Description Enables or disables IPMI LAN channel. This object is applicable only to CMC.
This object is applicable only to CMC. Legal Values None Default None cfgServerRootPassword (Write Only) Description Displays the password for iDRAC as a series of asterisks (*). It cannot be seen or displayed after this property is written. This object is applicable only to CMC. Legal Values None Default None cfgServerFirstBootDevice (Read or Write) Description Sets or displays the first boot device. For iDRAC, you can also set a vFlash partition that is attached as a bootable device.
For CMC, this object is Write only. Legal Values • • Default 1(True) 1(True) 0 (False) cfgServerPowerConsumption (Read Only) Description Displays the current power consumption for a server. This object is applicable only to CMC. Legal Values None Default None Example racadm getconfig -g cfgServerInfo -i 8 # cfgServerInfoIndex=8 # cfgServerSlotNumber=8 # cfgServerServiceTag= cfgServerName=SLOT-08 # cfgServerFW=3.
# cfgServerBmcMacAddress=00:18:8B:FF:41:43 # cfgServerNic1MacAddress=00:1A:A0:FF:D9:F4 # cfgServerNic2MacAddress=00:1A:A0:FF:D9:F6 cfgServerPriority=1 cfgServerNicEnable=1 cfgServerIPMIOverLANEnable=1 # cfgServerPowerBudgetAllocation=0 cfgServerDNSRegisterIMC=0 cfgServerDNSIMCName=iDRAC-1S0M0G1 # cfgServerRootPassword=******** (Write-Only) # cfgServerFirstBootDevice=******** (Write-Only) # cfgServerBootOnce=******** (Write-Only) # cfgServerPowerConsumption=0 cfgActiveDirectory This group contains parameter
cfgADEnable (Read or Write) Description Enables or disables Active Directory user authentication on iDRAC or CMC. If this property is disabled on iDRAC, only local iDRAC authentication is used for user logins. If this property is disabled for CMC, either local CMC or LDAP authentication may be used for user logins. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgADSCLEnable Description Enables you to log on to the CMC without enabling the Smart Card login.
cfgADDomainController2 (Read or Write) Description To obtain user names, specify the LDAP server from which you want the iDRAC. This object is applicable only to iDRAC. Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name (FQDN). Default None cfgADDomainController3 (Read or Write) Description To obtain user names, specify the LDAP server from which you want the iDRAC. This object is applicable only to iDRAC.
cfgADGlobalCatalog Description To obtain user names, specify the Global Catalog server from which you want the CMC. It must be used with cfgADSpecifyServerEnable. This object is applicable only to CMC. Legal Values Valid IP address or FQDN Default None Example racadm getconfig -g cfgActiveDirectory cfgADEnable=1 cfgADSCLEnable=0 cfgADSSOEnable=0 cfgADRacDomain= cfgADRootDomain=help cfgADRacName= cfgADRacAuthTimeout=300 cfgADType=0x4 cfgADSpecifyServerEnable=1 cfgADDomainController=192.168.1.
cfgADCertValidationEnable (Read or Write) Description Enables or disables Active Directory certificate validation as a part of the Active Directory configuration process. This object is applicable only to iDRAC. Legal Values • • Default 1 1 (TRUE) 0 (FALSE) cfgADDcSRVLookupEnable (Read or Write) Description Configures iDRAC to use pre‑configured domain controllers or to use DNS to find the domain controller.
cfgADGcSRVLookupEnable (Read or Write) Description Determines how the global catalog server is looked up. If using pre‑configured global catalog servers, then iDRAC uses the values cfgAdGlobalCatalog1, cfgAdGlobalCatalog2 and cfgAdGlobalCatalog3. This object is applicable only to iDRAC.
NOTE: You can specify multiple servers by separating each server with a comma. For example, example.com, sub1.example.com Legal Values String. • • Default For iDRAC: Maximum length = 1024 For CMC: Maximum length = 254 Null cfgLdapPort (Read or Write) Description Port of LDAP over SSL. Non-SSL port is not supported. Legal Values 1–65535 Default 636 cfgLdapBasedn (Read or Write) Description The domain name of the branch of the directory where all searches must start. Legal Values String.
For CMC: If enabled, the CMC performs DN matching, otherwise the CMC uses the user name provided at login for matching. Legal Values • • Default 1 1(TRUE) — Use the userDN from the LDAP Server 0(FALSE) — Use the userDN to provide the login user cfgLdapBinddn (Read/Write) Description The distinguished name of a user used to bind to the server when searching for the login user's DN. If not provided, an anonymous bind is used. If necessary It is optional to support anonymous bind.
cfgLDAPNetworkTimeout Description Configures the network timeout in seconds. This object is applicable only to CMC. Legal Values Positive integer Default 30 seconds cfgLDAPSearchTimeout Description Configures the search timeout in seconds. This object is applicable only to CMC. Legal Values Positive integer Default 120 seconds cfgLDAPSRVLookupEnable Description To query a DNS server for SRV records, Configure the CMC. This object is applicable only to CMC.
For CMC, this group configures Generic LDAP Role group descriptions and defines the CMC privileges that LDAPauthenticated users are granted. Use this object with the config or getconfig subcommands. To use this object property for CMC, you must have the Chassis Configuration Administrator privilege. NOTE: For CMC, you can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the —o option.
cfgLocation This group defines objects that support physical location properties. Use this object with the config or getconfig subcommands. To use this object property for CMC, you must have the Chassis Configuration Administrator privilege. This group is applicable only for CMC. cfgLocationDatacenter (Read or Write) Description Indicates data center name. Legal Values String of up to 128 ASCII characters Default 0 cfgLocationAisle (Read or Write) Description Indicates aisle where server is located.
To use this object property for CMC, you must have the Chassis Configuration Administrator privilege. NOTE: For CMC, you can configure a setting that does not have hash sign (#) prefixed in the output. To modify a configurable object, use the —o option. The following sections provide information about the objects in the cfgStandardSchema. cfgSSADRoleGroupIndex (Read Only) Description Index of the Role Group as recorded in the Active Directory.
Configure iDRAC 0x00000002 Configure Users 0x00000004 Clear Logs 0x00000008 Execute Server Control Commands 0x00000010 Access Virtual Console 0x00000020 Access Virtual Media 0x00000040 Test Alerts 0x00000080 Execute Debug Commands 0x00000100 cfgChassisPower This group contains parameters to display or configure power for the chassis. Use this object with the config or getconfig subcommands. This group is applicable only for CMC.
cfgChassisEPPEnable Description Enables the Extended Power Performance (EPP). Legal Values • • Default 0 — Disabled 1 — Enabled 0 — Disabled NOTE: For chassis with 3000W AC six PSU configuration (configured for Grid Redundancy policy), the default value is 1–Enabled. cfgChassisInPower (Read Only) Description Indicates the cumulative input power consumption data (in watts and BTU/hr) captured from all healthy and functional PSUs in the chassis.
cfgChassisPowerStatus (Read Only) Description Indicates the power status of the chassis. Legal Values • • • • • • Default None 1 — (other) 2 — (unknown) 3 — (OK) 4 — (noncritical) 5 — (critical) 6 — (nonrecoverable) cfgChassisRedundantState (Read Only) Description Enables or disables power redundancy for the chassis.
Default 43221 BTU/hr cfgChassisPowerCapFBTU (Read or Write) Description Indicates the maximum power consumption limit (in BTU/hr) for the entire chassis. Use cfgChassisCapFBTU when power consumption changes regardless of whether server throttling is required. The command generates an error if the value for this setting is lower than the minimum power required for the chassis configuration.
Default 0 — (disabled) cfgChassisAllow110VACOperation (Read or Write) Description Enables or disables normal chassis power allocations when any PSU is connected to 110 V AC service. If disabled and 110 V power supplies are detected, all subsequent server power allocation requests are denied. In this mode more servers cannot be powered on, regardless of server priority.
cfgChassisInRedundancyReserve (Read Only) Description Indicates the amount of redundant power (in watts) in reserve that can be utilized in the event if an AC grid or PSU is unsuccessful. This value is0 if the Redundancy Policy is set to 0 (no redundancy). Legal Values 0 (disabled) 1 (enabled) Default None cfgChassisInPowerServerAllocation (Read Only) Description Indicates (in watts) the cumulative power allocated to servers.
cfgChassisPowerClearTimestamp (Read Only) Description Time stamp when cfgChassisMinPower and cfgChassisMaxPowerCapacity were reset. Legal Values None Default None cfgChassisPowerButtonEnable (Read or Write) Description Indicates if the chassis power button is enabled or disabled. Legal Values • • Default None 0(disabled) 1(enabled) cfgSystemEnergyConsumptionClear (Write Only) Description Resets energy statistics when set to 1.
# cfgSystemEnergyConsumptionClear = ****(Write-Only) cfgChassisServerBasedPowerMgmtMode=0 racadm config -g cfgChassisPower ‑o cfgChassisPowerClear 1 • Clears cfgChassisMinPower and cfgChassisPeakPower. cfgThermal This group displays and configures the thermal settings. Use this object with the config or getconfig subcommands. This group is applicable only for CMC. To set the configurations, you must have the Chassis Configuration Administrator privileges.
• Default 4(Administrator) 4 cfgIpmiSolAccumulateInterval (Read or Write) Description Specifies the typical amount of time that iDRAC waits before transmitting a partial SOL character data packet. This value is 1-based 5ms increments. Legal Values 1–255 Default 10 cfgIpmiSolSendThreshold (Read or Write) Description To buffer before sending an SOL data packet, specify the SOL threshold limit value and the maximum number of bytes.
cfgIpmiLanAlertEnable (Read or Write) Description Enables or disables global email alerting. This property overrides all individual email alerting enable or disable properties. Legal Values • • Default 0 1(TRUE) 0(FALSE) cfgIpmiLanEncryptionKey (Read or Write) Description Specifies the IPMI encryption key. Legal Values A string of hexadecimal digits from 0 to 40 characters with no spaces. Only an even number of digits is allowed.
cfgIpmiPetIPv6AlertEnable (Read or Write) Description Enables or disables the IPv6 alert destination for the trap. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgIpmiPef This group is used to configure the platform event filters available on the managed server. It is applicable only for iDRAC. The event filters can be used to control policy related to actions that are triggered when critical events occur on the managed server.
cfgIpmiPefEnable (Read or Write) Description Enables or disables a specific platform event filter. Legal Values • • Default 1 1(TRUE) 0(FALSE) cfgIpmiPet This group is applicable only for iDRAC and is used to configure platform event traps on the managed server. The following sections provide information about the objects in the cfgIpmiPet group. cfgIpmiPetIndex (Read Only) Description Unique identifier for the index corresponding to the trap.
cfgUserDomainIndex (Read Only) Description Represents a specific domain. Legal Values 1–40 Default The index value. cfguserdomainname (Read Only) Description Specifies the Active Directory user domain name. Legal Values A string of up to 254 ASCII characters Default cfgServerPower This group provides several power management features. It is applicable only for iDRAC. The following sections provide information about the objects in the cfgServerPower group.
This object is applicable only for iDRAC. Legal Values Not applicable Default cfgServerPowerCapEnable (Read or Write) Description Enables or disables the user specified power budget threshold. This object is Read only for iDRAC Enterprise on Blade Servers.
cfgServerPowerConsumptionClear (Write Only) Description Clears the current recorded power statistics. This object is applicable only for iDRAC. Legal Values 1 — Clears the Power Consumption Statistics Default None cfgServerPowerCapWatts (Read or Write) Description Represents the server power threshold in Watts. This object is applicable only for iDRAC. NOTE: This value is applicable only if the cfgServerPowerCapEnable is set to 1. Legal Values None Default Server power threshold in Watts.
cfgServerPowerLastDayAvg (Read Only) Description Displays the average power value during the last day. This object is applicable only for iDRAC. Legal Values None Default Average power value during the last day. cfgServerPowerLastWeekAvg (Read Only) Description Displays the average power value during the last week. This object is applicable only for iDRAC. Legal Values None Default Average power value during the last week.
This object is applicable only for iDRAC. Legal Values Not applicable Default Maximum power value during the last hour. cfgServerPowerLastHourMaxTime (Read Only) Description Displays the timestamp of maximum power value during the last hour. This object is applicable only for iDRAC. Legal Values Time in the format: DD MM Date HH:MM:SS YYYY where, • • • • • • • Default DD= Day of the week MM= Month Date=Date YYYY = Year HH = hour MM=Minutes SS = Seconds Maximum power value during the last hour.
cfgServerPowerLastDayMaxPower (Read Only) Description Displays the maximum power value during the last day. This object is applicable only for iDRAC. Legal Values Not applicable Default Maximum power value during the last day. cfgServerPowerLastDayMaxTime (Read Only) Description Displays the timestamp of maximum power value during the last day. This object is applicable only for iDRAC.
• Default SS = Seconds Timestamp of the minimum power value during the last week. cfgServerPowerLastWeekMaxPower (Read Only) Description Displays the maximum power value during the last week. This object is applicable only for iDRAC. Legal Values None Default Maximum power value during the last week. cfgServerPowerLastWeekMaxTime (Read Only) Description Displays the timestamp of maximum power value during the last week. This object is applicable only for iDRAC.
cfgServerActualAmperageConsumption (Read Only) Description Displays the current power consumption. This object is applicable only for iDRAC. Legal Values Not applicable Default Current power consumption. cfgServerPeakAmperage (Read Only) Description Displays the current peak power consumption. Legal Values Not applicable Default Current peak power consumption. cfgServerPeakAmperageTimeStamp (Read Only) Description Displays the timestamp of the current peak power consumption.
Time in the format: DD MM Date HH:MM:SS YYYY where, • • • • • • • Default DD = Day of the week MM= Month Date=Date YYYY = Year HH = hour MM=Minutes SS = Seconds Timestamp of the cumulative power consumption. cfgServerCumulativePowerClear (Write Only) Description Clears the cfgServerCumulativePowerConsumption and cfgServerCumulativePowerConsumptionTimeStamp values. This object is applicable only for iDRAC.
Default None cfgKVMFrontPanelEnable Description Enables or disables front panel access on the iKVM. Legal Values • • Default None 1 (enable) 0 (disable) Example racadm getconfig -g cfgKVMInfo cfgKVMAccessToCMCEnable=1 cfgKVMFrontPanelEnable=1 cfgAlerting This group enables or disables SNMP event trap alerting and sets the event filter. This group is applicable only for CMC. Use this object with the config or getconfig subcommands.
Examples racadm getconfig -g cfgAlerting -o cfgAlertingSourceEmailName racadm config -g cfgAlerting -o cfgAlertingSourceEmailName user@home.com Object value modified successfully. cfgLcdLocale Description Specifies the Language (locale) for the Blade Chassis LCD interface. Legal Values de, fr, en, es, ja, zh-cn. Default en racadm config -g cfgLcdInfo -o cfgLcdLocale en Example Object value modified successfully. cfgServerPowerSupply This group contains information related to the power supplies.
cfgServerPowerSupplyMaxOutputPower (Read Only) Description Displays the AC output rated power in Watts. Legal Values A string of up to 32 characters. Default 0 cfgServerPowerSupplyOnlineStatus (Read Only) Description Displays the status of the PSU. Legal Values • • • • Default 0 — Present 0 — Present 1 — Absent 2 — Failure 3 — Predictive failure cfgServerPowerSupplyFwVer (Read Only) Description Displays the firmware version of the PSU, in the format x.xx.xxx.
The following sections provide information about the objects in the cfgIPv6LanNetworking group. cfgIPv6Enable (Read or Write) Description Enables or disables iDRAC or CMC IPv6 stack. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgIPv6Address Description Assigns a static IPv6 address to the CMC. This property is used only if cfgIPv6AutoConfig is set to 0 (false). NOTE: This object is applicable only for CMC. Legal Values A string representing a valid IPv6 address.
cfgIPv6AutoConfig (Read or Write) Description Enables or disables the IPv6 Auto Configuration option. NOTE: If this value is set to0, the CMC disables auto configuration and statically assigns IPv6 addresses. If this value is set to 1, the CMC obtains address and route information using stateless auto configuration andDHCPv6. NOTE: The CMC uses its MAC address for its DUID (DUID-LL) when communicating with a DHCPv6 server.
Default : cfgIPv6Address5 (Read Only) Description The iDRAC IPv6 fifth address. This object is applicable only for iDRAC. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address6 (Read Only) Description The iDRAC IPv6 sixth address. This object is applicable only for iDRAC. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address7 (Read Only) Description The iDRAC IPv6 seventh address. This object is applicable only for iDRAC.
Default : cfgIPv6Address11 (Read Only) Description The iDRAC IPv6 eleventh address. This object is applicable only for iDRAC. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address12 (Read Only) Description The iDRAC IPv6 twelfth address. This object is applicable only for iDRAC. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address13 (Read Only) Description The iDRAC IPv6 thirteenth address. This object is applicable only for iDRAC.
NOTE: This property is used only if cfgIPv6AutoConfig is set to 1(true). Legal Values 1 (TRUE) 0 (FALSE) Default For iDRAC:0 For CMC: 1 cfgIPv6DNSServer1 (Read/Write) Description Specifies the IPv6 DNS server address. NOTE: This property is used only if cfgIPv6DNSServersFromDHCP6 is set to 0(false). Legal Values A string representing a valid IPv6 entry.
cfgIpv6StaticLanNetworking This group is used to configure the IPv6 Static over LAN networking capabilities. This group is applicable only for iDRAC. cfgIPv6StaticEnable (Read or Write) Description Enables or disables the static IPv6 stack. Legal Values • • Default 0 — Disabled 0 — Disabled 1 — Enabled NOTE: If this object is modified, then the object cfgIPv6Enable is also modified. cfgIPv6StaticAddress1 (Read or Write) Description Returns or sets the static IPv6 address1.
NOTE: If this object is modified, then the object cfgIPv6Autoconfig is also modified. cfgIPv6StaticDNSServersFromDHCP6 (Read or Write) Description Specifies the DNS server static IP addresses. Legal Values • • Default 0 — Disabled 0 — DNS Server must be configured as static. 1 — The device will get the DNS servers from DHCPv6. cfgIPv6StaticDNSServer1 (Read or Write) Description Specifies the DNS server 1 static IPv6 address.
cfgNicCurrentGateway Displays the static gateway for the CMC IP address. Description Displays the static gateway for the CMC IP address. Legal Values Default cfgNicCurrentDhcpWasUsed Description Indicates whether DHCP is used to configure the NIC. Legal Values 0 — address is static. 0 — address was obtained from the DHCP server. Default None cfgNicCurrentVlanEnable (Read Only) Description Indicates whether the VLAN is enabled.
cfgDNSCurrentServer2 Description Displays the IP address for DNS server 2. Legal Values Default cfgDNSCurrentDomainName Description Displays the DNS domain name. Legal Values Default cfgNicCurrentIPv4Enabled Description Indicates whether IPv4 is enabled on the CMC. If the current property value is set to 0(false), the remote network interfaces to the CMC are not accessible over IPv4.
cfgCurrentIPv6AutoConfigWasUsed Description Indicates whether auto configuration is used to obtain IPv6 settings, including stateless IPv6 addresses and gateway. Legal Values 0 (static addressing is used) 1 (address is obtained from the DHCPv6 server and/or stateless auto configuration) Default None cfgCurrentLinkLocalAddress Description Displays the current IPv6 link-local address of the CMC. Legal Values Default cfgCurrentIPv6Address1 Description Displays the current IPv6 addresses.
cfgCurrentIPv6DNSServer2 Description Displays the IPv6 address for DNS server 2.
cfgIpmiSerialChanPrivLimit (Read or Write) Description Specifies the maximum privilege level allowed on the IPMI serial channel. Legal Values • • • Default 4 2 (User) 3 (Operator) 4 (Administrator) cfgIpmiSerialConnectionMode (Read or Write) Description When the iDRAC cfgSerialConsoleEnable property is set to 0(disabled), the iDRAC serial port becomes the IPMI serial port. This property determines the IPMI defined mode of the serial port.
Default 1 cfgIpmiSerialHandshakeControl (Read or Write) Description Enables or disables the IPMI terminal mode handshake control. Legal Values • • Default 1 0(FALSE) 1 (TRUE) cfgIpmiSerialNewLineSequence (Read or Write) Description Specifies the new line sequence specification for the IPMI serial interface.
cfgSmartCardLogonEnable (Read or Write) Description To iDRAC using a smart card, enable or disable with Remote RACADM support for access. NOTE: Enabling with remote RACADM is only applicable for iDRAC on Rack and Tower Servers. Legal Values • • • Default 0 0 (Disabled) 1 (Enabled) 2 (Enabled with Remote RACADM) — It is not applicable for iDRAC Enterprise on Blade Servers. cfgSmartCardCRLEnable (Read or Write) Description Enables or disables the Certificate Revocation List (CRL).
• Default 1 = Auto Negotiation is Enabled 1 Example racadm getconfig -g cfgNetTuning cfgNetTuningNicSpeed=100 cfgNetTuningNicFullDuplex=1 cfgNetTuningNicMtu=1500 cfgNetTuningNicAutoneg=1 cfgNetTuningNic100MB (Read or Write) Description To use for the RAC NIC, specify the speed. This property is not used if cfgNetTuningNicAutoNeg is set to 0 (disabled). NOTE: To set this property: • • • Legal Values • • • Default 1 iDRAC.NIC.Selection must be set to Dedicated mode. iDRAC.NIC.
cfgSensorRedundancy This group is used to set the power supply redundancy. This group is applicable only for iDRAC. The following sections provide information about the objects in the cfgSensorRedundancy group. This group is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. cfgSensorRedundancyIndex (Read Only) Description Specifies index for the sensor redundancy group being read. Only power supply redundancy is supported.
• • Default Lost Degraded None cfgVFlashSD This group is used to configure the properties for the Virtual Flash SD card. This group is applicable only for iDRAC. NOTE: If the vFlash card is present but is not enabled, the query for any property under this group displays: ERROR: vFlash is not enabled.
cfgVFlashSDLicensed (Read Only) Description Displays whether an SD card or vFlash SD card is inserted. The vFlash SD card supports the new enhanced vFlash features and the SD card supports only the limited vFlash features. Legal Values • • Default None 0(SD card is inserted) 1(vFlash SD card is inserted) cfgVFlashSDAvailableSize (Read Only) Description Displays the available memory (in MB) on the vFlash SD card that can be used to create new partitions.
cfgVFlashPartitionIndex (Read Only) Description The index value of the partition. Legal Values Integer 1–16 Default None cfgVFlashPartitionSize (Read Only) Description Displays the size of the partition. Legal Values 1 MB to 4 GB Default None cfgVFlashPartitionEmulationType (Read or Write) Description View or modify the emulation type for the partition.
cfgVFlashPartitionAccessType (Read or Write) Description Indicates the partition access permissions. It configures the access type to read-write. Legal Values • • Default 0 0 (ReadOnly) 1 (ReadWrite) cfgVFlashPartitionAttachState (Read or Write) Description View or modify the partition to attached or detached. NOTE: Detaching the vFlashPartition by setting the cfgVFlashPartitionAttachState to 0 does not require a license.
cfgRacSecCsrCommonName (Read or Write) Description Specifies the CSR Common Name (CN) that must be an IP or CMC name as given in the certificate. Legal Values A string of up to 254 characters. Default cfgRacSecCsrOrganizationName (Read or Write) Description Specifies the CSR Organization Name (O). Legal Values A string of up to 254 characters. Default cfgRacSecCsrOrganizationUnit (Read or Write) Description Specifies the CSR Organization Unit (OU).
cfgRacSecCsrEmailAddr (Read/Write) Description Specifies the CSR email address. Legal Values A string of up to 254 characters. Default Example racadm config -g cfgRacSecurity cfgRacSecCsrKeySize=1024 cfgRacSecCommonName= cfgRacSecOrganizationName= cfgRacSecOrganizationUnit= cfgRacSecLocalityName= cfgRacSecStateName= cfgRacSecCountryCode= cfgRacSecEmailAddr= cfgRacSecCsrKeySize (Read or Write) Description Specifies the SSL asymmetric key size for the CSRs.
Database Objects With Get and Set Commands 4 This chapter provides the database groups and objects that must be used with the get or set subcommands. The groups and objects are applicable only for iDRAC7. When using the objects, they must begin with FQDD or FQDD alias. The set operations for iDRAC, Lifecycle Controller and system objects do not require server restart.
System.ChassisInfo.Name (Read) Description Provides the name of the chassis. For example: CMC-nobel01. Legal Values String of up to 62 ASCII characters Default Value None Dependency None System.ChassisInfo.ServiceTag (Read) Description Provides the Service Tag of the chassis. Legal Values String of up to 62 ASCII characters Default Value None Dependency None System.LCD This group enables you to manage the front panel LCD user string settings.
System.LCD.CurrentDisplay (Read Only) Description The string currently displayed on the LCD. Legal Values None Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.LCD.LCDUserString (Read or Write) Description Indicates the LCD string set. Legal Values String of up to 62 ASCII characters Default Value 0 System.Location This group enables you to manage the server's physical location characteristics.
System.Location.DeviceSize (Read Only) Description Indicates server chassis size. Legal Values Values: 1–255 Default Value Depends on the server form factor Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Location.Rack.Name (Read or Write) Description Indicates rack where the system is located.
System.Location.Chassis.Name (Read Only) Description Indicates the chassis name. Legal Values String of up to 128 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Location.Chassis.Slot (Read or Write) Description Indicates chassis slot. Legal Values Values: 1–255 Write Privilege Configure iDRAC Dependency None System.Power This group provides power management features for iDRAC.
System.Power.Avg.LastDay (Read Only) Description Indicates the average power value during the last day. Legal Values Values: 1–65535 Default Value Average power value during the last day. Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Avg.LastHour (Read Only) Description Displays the average power value during the last hour. Legal Values Values: 1–65535 Default Value Average power value during the last hour.
System.Power.Cap.ActivePolicy.Name (Read Only) Description Displays the Active Power Cap Policy Name Legal Values String of up to 128 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Cap.ActivePolicy.
Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Cap.MaxThreshold (Read Only) Description Because it is based on the current component inventory, it has maximum server power capacity. Legal Values Values: 1–65535 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Cap.
System.Power.Redundancypolicy Description Selects the redundancy policy. Legal Values • • N/A Not Redundant — In this mode, even if one PSU stops functioning, the server is automatically turned off. A/C Input Redundant — In this mode, the system is functional even if one PSU input circuit stops functioning, provided the PSUs are connected to different input circuits. This is also called AC redundancy. PSU Redundant — Available only on systems with four PSUs. This is also called DC redundancy.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.EnergyConsumption.Clear (Read or Write) Description Clears the cumulative power consumption timestamps. Legal Values 1 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.EnergyConsumption.StarttimeStamp (ReadOnly) Description Displays the Timestamp of the cumulative power consumption.
NOTE: This object is supported only for iDRAC on Rack and Tower servers. Legal Values • • • • Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 1 — PSU1 2 — PSU2 5 — PSU1 and PSU3 10 — PSU2 and PSU4 System.Power.Max.Amps (Read Only) Description Specifies the device Peak Power Consumption since this value was last cleared. Legal Values Values: 1–65535.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Max.LastDay (Read Only) Description Displays the maximum power value during the last day. Legal Values Values: 1–65535 Default Value Maximum power value during the last day. Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Max.LastDay.TimeStamp (Read Only) Description Displays the timestamp of maximum power value during the last day.
Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Max.LastWeek (Read Only) Description Displays the maximum power value during the last week. Legal Values Values: 1–65535 Default Value Maximum power value during the last week. Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Max.LastWeek.
Default Value Timestamp of the peak power consumption of the server. Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Max.PowerClear (Read Only) Description Clears the Maximum Power Consumption timestamps. Legal Values 1 — Clear the Power Consumption Statistics Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Min.
Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Min.LastHour.Timestamp (Read Only) Description Indicates the timestamp of minimum power during the last hour. Legal Values String of up to 254 ASCII characters Default Value Timestamp of the minimum power value during the last hour. Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Min.
• 1 — Enabled Default Value • • 0 — For platforms that do not support PCIe cards. 500 W — For platforms that support PCIe cards. Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.PFCEnable (Read or Write) Description Enables the power factor correction enable. NOTE: • • This object is supported only for iDRAC on Rack and Tower servers. This object is applicable only if System.Power.Cap.Enable is set to 1.
Default Value 0 — not applicable System.Power.RedundantState (Read Only) Description Retrieves the redundancy state for the chassis. Legal Values • • Default 0 — None 0 — None 1 — Full System.Power.Supply This group provides information relating to the Power Supplies. This group is indexed from 1 to 4. If there are less than four power supplies on the server, then some of the last indexes of this group are not applicable. This group is not applicable for iDRAC on Rack and Tower servers.
System.Power.Supply.[i].MaxOutputPower (Read Only) Description Displays the DC output rated power in Watts. Legal Values Integer > 0 Default 0 System.Power.Supply.[i].Status (Read Only) Description Displays the status of the PSU. Legal Values • • • • Default 0 — absent 0 — absent 1 — present and OK 2 — failure 3 — predictive failure System.Power.Supply.[i].Type (Read Only) Description Displays whether the power supply is AC or DC.
System.ServerOS.HostName (Read or Write) Description Displays the host name of the managed server. Legal Values String of up to 256 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.ServerOS.OSName (Read or Write) Description Displays the operating system name of the managed server.
• 255 — None Default value 255 — None License Required iDRAC7 Express Dependency None System.ThermalSettings.BaseAlgorithm (Read or Write) Description Legal Values Specifies the thermal base algorithm. • • • 0 — Auto 1 — Max Exhaust Temperature 2 — Min Power Default values None License Required iDRAC7 Express Dependency None System.ThermalSettings.FanSpeedOffset (Read or Write) Description Legal Values Specifies the fan speed offset.
• 1 — Enabled Default Value 0 — Disabled Write Privilege Server Control License Required iDRAC7 Enterprise Dependency None LifecycleController.LCAttributes.autoupdate (Read or Write) Description Legal Values Enables or disables the automatic update scheduler. • • 0 — Disabled 1 — Enabled Default Value 1 — Enabled Write Privilege Server Control License Required iDRAC7 Enterprise Dependency None LifecycleController.LCAttributes.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None LifecycleController.LCAttributes.LifecycleControllerState (Read or Write) Description Legal Values Enables or disables lifecycle controller. • • • 0 — Disabled 1 — Enabled 2 — Recovery (Read Only Value) Default Value 1 — Enabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None LifecycleController.LCAttributes.
iDRAC.ActiveDirectory To manage the configuration of the iDRAC Active Directory features, use the objects in this group. iDRAC.ActiveDirectory.AuthTimeout (Read or Write) Description To wait for ActiveDirectory authentication requests to complete before timing out, specify the time in seconds. Legal Values Integral values: 15–300 Default Value 120 Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.ActiveDirectory.
iDRAC.ActiveDirectory.DCLookupDomainName (Read or Write) Description The configured search domain is used when DCLookupByUserDomain is disabled. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.ActiveDirectory.
Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.ActiveDirectory.DomainController3 (Read or Write) Description FQDN that stores the address of the active directory domain controller 3 Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.ActiveDirectory.Enable (Read or Write) Description Enables or disables Active Directory user authentication on iDRAC.
• IPv6.DNS2 iDRAC.ActiveDirectory.GCRootDomain (Read or Write) Description The names of the Active Directory root domain used for DNS look up. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required None Dependency None iDRAC.ActiveDirectory.GlobalCatalog1 (Read or Write) Description Specifies the Global Catalog server from which you want the iDRAC to obtain user names.
iDRAC.ActiveDirectory.RacDomain (Read or Write) Description Active Directory Domain in which iDRAC resides. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.ActiveDirectory.RacName (Read or Write) Description Name of iDRAC as recorded in the Active Directory forest.
License Required iDRAC7 Enterprise Dependency Cannot be enabled unless SmartCard Logon Enable is disabled. iDRAC.ADGroup To manage the configuration of AD standard schema settings, use these objects in the group. This group is indexed from 1 to 5. iDRAC.ADGroup.Domain (Read or Write) Description Active Directory Domain in which the Role Group resides. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.
iDRAC.AutoOSLock.AutoOSLockState (Read or Write) Description Enable or Disable OS Auto lock feature. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.EmailAlert The objects in this group configure email alerting capabilities. This group is indexed from 1 to 4. iDRAC.EmailAlert.Address (Read or Write) Description Specifies the destination email address for email alerts.
Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Info To manage information about iDRAC being queried, use these objects in the group. iDRAC.Info.Build (Read Only) Description String containing the current product build version. Legal Values String of up to 16 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Info.
iDRAC.Info.Product (Read Only) Description String identifying the Product. Legal Values String of up to 63 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Info.Type (Read Only) Description Identifies the remote access controller type Legal Values • • Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 16 (12G iDRAC Monolithic) 17 (12G iDRAC Modular) iDRAC.Info.
Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPBlocking To configure IP address blocking feature of iDRAC, Use the objects in this group. iDRAC.IPBlocking.BlockEnable (Read or Write) Description Legal Values Enables or disables the IPv4 address blocking feature of iDRAC.
iDRAC.IPBlocking.PenaltyTime (Read or Write) Description Defines the time span in seconds that session requests from an IP address with excessive failures are rejected. Legal Values Integral values: 2–65535 Default Value 600 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPBlocking.RangeAddr (Read or Write) Description Specifies the acceptable IPv4 address bit pattern in positions determined by the 1s in the range mask.
Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPMILan To configure IPMI over LAN of the system, use the objects in this group. iDRAC.IPMILan.AlertEnable (Read or Write) Description Legal Values Enables or disables global email alerting. • • 0 — Disabled 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPMILan.
Dependency None iDRAC.IPMILan.EncryptionKey (Read or Write) Description Enables or disables the IPMI over LAN interface. Legal Values String of up to 18 ASCII characters Default Value 0000000000000000000000000000000000000000 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPMILan.PrivLimit (Read or Write) Description Specifies the maximum privilege level for IPMI over LAN access.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPMISerial.ChanPrivLimit (Read or Write) Description Specifies the maximum privilege limit allowed on the IPMI serial channel. Legal Values • • • Default Value 4 — Administrator Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 2 — User 3 — Operator 4 — Administrator iDRAC.IPMISerial.
iDRAC.IPMISerial.EchoControl (Read or Write) Description Enables or disables echo control on the IPMI serial interface. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.IPMISerial.FlowControl (Read or Write) Description Specifies the Flow Control setting for IPMI serial port.
• 2 — Null Default Value 2 — Null Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPMISerial.LineEdit (Read or Write) Description Enables or disables line editing on the IPMI serial interface. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.IPMISerial.
iDRAC.IPMISOL.AccumulateInterval (Read or Write) Description Specifies the typical amount of time that iDRAC waits before transmitting a partial SOL character data packet. Legal Values Integral values: 1–255 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPMISOL.BaudRate (Read or Write) Description Legal Values Specifies the Baud rate for serial communication over LAN.
• 4—Administrator Default Value 4—Administrator Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPMISOL.SendThreshold (Read or Write) Description To buffer before sending an SOL data packet, specifies the SOL threshold limit value and the maximum number of bytes Legal Values Integral values: 1–255 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Cannot be enabled unless IPv4.Enable is enabled. iDRAC.IPv4.DNS1 (Read or Write) Description IPv4 address for DNS server 1. Legal Values Valid IPv4 Address Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Cannot be set unless IPv4.DNSFromDHCP is disabled. iDRAC.IPv4.DNS2 (Read or Write) Description IPv4 address for DNS Server 2.
iDRAC.IPv4.Enable (Read or Write) Description Enables or disables the iDRAC IPv4 stack. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.IPv4.Gateway (Read or Write) Description The gateway for the iDRAC IPv4 address. Legal Values Valid IPv4 gateway Default Value 192.168.0.
iDRAC.IPv4Static.Address (Read or Write) Description iDRAC static IPv4 address. This address can be configured even when DHCP is enabled. Legal Values Valid IPv4 Address Default Value 192.168.0.120 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv4Static.DNS1 (Read or Write) Description Statically configurable DNS Server 1. Legal Values Valid IPv4 Address Default Value 0.0.0.
Dependency None iDRAC.IPv4Static.Netmask (Read or Write) Description iDRAC static IPv4 subnet mask. This address can be configured even when DHCP is enabled. Legal Values Valid IPv4 netmask Default Value 255.255.255.0 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6 To manage the IPv6 configuration properties of iDRAC, use the objects in this group. iDRAC.IPv6.Address 1 (Read or Write) Description iDRAC IPv6 Address.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6.Address 4 (Read Only) Description iDRAC IPv6 fourth address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6.Address 5 (Read Only) Description iDRAC IPv6 fifth address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.
iDRAC.IPv6.Address 8 (Read Only) Description iDRAC IPv6 eighth address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6.Address 9 (Read Only) Description iDRAC IPv6 ninth address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6.Address10 (Read Only) Description iDRAC IPv6 tenth address.
iDRAC.IPv6.Address12 (Read Only) Description iDRAC IPv6 twelfth address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6.Address13 (Read Only) Description iDRAC IPv6 thirteenth address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6.Address14 (Read Only) Description iDRAC IPv6 fourteenth address.
iDRAC.IPv6.AutoConfig (Read or Write) Description Enables or disables the iDRAC IPv6 auto configuration option. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.IPv6.DNS1 (Read or Write) Description IPv6 DNS Server 1 Address.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Cannot be Enabled unless IPv6.AutoConfig is enabled. iDRAC.IPv6.Enable (Read or Write) Description Enables or Disables iDRAC IPv6 stack. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.IPv6.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6Static To manage the IPv6 static configuration properties of iDRAC, use the objects in this group iDRAC.IPv6Static.Address1 (Read or Write) Description iDRAC static IPv6 address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6Static.DNS1 (Read or Write) Description Statically configurable DNS Server 1.
Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6Static.Gateway (Read or Write) Description iDRAC static IPv6 gateway. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6Static.PrefixLength (Read or Write) Description Prefix length for the iDRAC IPv6 Address.
iDRAC.LDAP To configure properties for LDAP settings, use the objects in this group. iDRAC.LDAP.BaseDN (Read or Write) Description The Domain Name of the branch of the directory where all searches must start. Legal Values String of up to 63 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.LDAP.BindDN (Read or Write) Description The domain name of the branch of the directory where all searches must start.
License Required iDRAC7 Enterprise Dependency None iDRAC.LDAP.Enable (Read or Write) Description Turns LDAP service on or off. Legal Values • • Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.LDAP.GroupAttribute (Read or Write) Description Specifies which LDAP attribute is used to check for group membership.
Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.LDAP.SearchFilter (Read or Write) Description A valid LDAP search filter to be used if the user attribute cannot uniquely identify the login user within the chosen baseDN. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.LDAP.Server (Read or Write) Description Configures the address of the LDAP Server.
iDRAC.LDAPRoleGroup.DN (Read or Write) Description The Domain Name of this group. Legal Values String of up to 1024 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.LDAPRoleGroup.Privilege (Read or Write) Description A bit-mask defining the privileges associated with this particular group.
• 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Logging iDRAC. Logging Manages the ability to configure iDRAC iDRAC.Logging.SELOEMEventFilterEnable (Read or Write) Description Enables or disables the ability of Logging SEL Records with OEM.
NOTE: – – Always configures the DHCP. If iDRAC is reset after this operation, the server including storage may be reconfigured. This may interrupt server operations and loss of data. Default Values 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.NIC.AutoDetect (Read or Write) Description Enables or disables auto detection feature of iDRAC.
License Required iDRAC7 Express (for Blades) or iDRAC7 Enterprise Dependency None iDRAC.NIC.DNSDomainFromDHCP (Read or Write) Description Specifies that the iDRAC DNS domain name must be assigned from the network DHCP server. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Can be Enabled only if the following are enabled: • • 0 — Disabled 1 — Enabled IPv4.Enable and IPv4.DHCPEnable IPv6.
iDRAC.NIC.DNSRacName (Read or Write) Description The iDRAC name. Legal Values String of up to 63 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.NIC.DNSRegister (Read or Write) Description Registers the iDRAC name with the DNS server.
Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.NIC.Failover (Read or Write) Description Enables or disables failover for iDRAC to switch from shared to dedicated. Legal Values • • • • • • Default Value 0 — None Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Possible Values depend on current NICSelection settings. 0 — None 2 — LOM1 3 — LOM2 4 — LOM3 5 — LOM4 6 — All iDRAC.NIC.
iDRAC.NIC.Selection (Read or Write) Description Specifies the current mode of operation for the iDRAC network interface controller. Legal Values • • • • • Default Value 1 — Dedicated Write Privilege Configure iDRAC License Required iDRAC7 Express (for Blades) or iDRAC7 Enterprise Dependency None 1 — Dedicated 2 — LOM1 3 — LOM2 4 — LOM3 5 — LOM4 iDRAC.NIC.SharedNICScanTime (Read or Write) Description Wait time for the iDRAC to switch from shared mode to dedicated mode.
iDRAC.NIC.VLanEnable (Read Only) Description Enables or disables the VLAN capabilities of the iDRAC. NOTE: This object is applicable only to iDRAC on Racks and Towers. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.NIC.VLanID (Read Only) Description Specifies the VLAN ID for the network VLAN configuration.
iDRAC.NICStatic.DNSDomainFromDHCP (Read or Write) Description Specifies that the iDRAC DNS domain name must be assigned from the network DHCP server. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.NICStatic.DNSDomainName (Read or Write) Description The DNS Domain Name.
Dependency None iDRAC.NTPConfigGroup.NTP3 (Read or Write) Description Configure NTP Server 3 Address. Legal Values String of up to 254 ASCII characters. Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.NTPConfigGroup.NTPEnable (Read or Write) Description On iDRAC, enable or disable NTP server access to iDRAC.
iDRAC.OS-BMC.AdminState (Read or Write) Description On iDRAC pass through, enable or disable administrative state of OS. Legal Values • • 0 — Disabled 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Can be set only if iDRAC.OSBMC.PTCapability is set to Capable. iDRAC.OS-BMC.OSIpAddress (Read or Write) Description IPv4 address of the host Operating System. Legal Values Valid IPv4 Address Default Value 0.0.
NOTE: To enable the pass-through, make sure that iDRAC.OSBMC.AdminState is enabled. Legal Values • • 0 — Iom-p2p 1 — usb-p2p Default Value 0 — Iom-p2p Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.OS-BMC.UsbNicIpAddress (Read or Write) Description Displays the USB NIC IP address. Legal Values Valid IPv4 address Default Value 169.254.0.
iDRAC.Racadm.Timeout (Read or Write) Description Defines the idle timeout in seconds of the Remote RACADM interface. Legal Values • • Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 0 — No timeout Integral values: 60–10800 iDRAC.RemoteHosts Use the objects in this group to manage the properties for configuration of the SMTP server. iDRAC.RemoteHost.SMTPPort (Read or Write) Description Specifies the destination port for email alerts.
iDRAC.RFS.AttachMode (Read or Write) Description RFS Media attach mode. Legal Values • • Default Value 1 — Auto Attach Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 0 — Attach 1 — Auto Attach iDRAC.RFS.MediaAttachState (Read Only) Description RFS Media attach state.
iDRAC.Security.CsrCountryCode (Read or Write) Description Specifies the CSR Country Code (CC). Legal Values String of a 2 Alphabet Country Code. For example: US Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Security.CsrEmailAddr (Read or Write) Description Specifies the CSR email address. Legal Values Valid email address string of up to 254 ASCII characters.
iDRAC.Security.CsrOrganizationName (Read or Write) Description Specifies the CSR Organization Name (O). Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Security.CsrOrganizationUnit (Read or Write) Description Specifies the CSR Organization Unit (OU).
Default Value 115200 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Serial.Command (Read or Write) Description Specifies a serial command that is executed after the user logs in to the serial console interface. Legal Values String of up to 128 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Serial.
iDRAC.Serial.IdleTimeout (Read or Write) Description The maximum number of seconds to wait before an idle serial console session is disconnected. Legal Values • • Default Value 300 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 0 — No timeout Integral values: 60–10800 iDRAC.Serial.NoAuth (Read or Write) Description Enables or disables iDRAC serial console login authentication.
iDRAC.SerialRedirection.QuitKey (Read or Write) Description This key or key combination terminates the Virtual Console when using the console COM2 command. Legal Values String of up to 4 ASCII characters. Default Value ^\ Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.serverboot The objects in this group manages the server boot options. iDRAC.serverboot.
• Attached vFlash Partition Label Default value Normal Write Privilege Login and configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.ServiceModule The objects in this group manages the properties of the ISM modules. iDRAC.ServiceModule.LCLReplication (Read or Write) Description Legal Values Enables Lifecycle log in operating system log Baud rate on the iDRAC serial port.
Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.ServiceModule.ServiceModuleState (Read or Write) Description Legal Values Indicates the status of Service Module process on the host operating system. • • 0 — Disabled 1 — Enabled Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.ServiceModule.
iDRAC.ServiceModule.WatchdogResetTime (Read and Write) Description Configures the system reset time (unit in seconds) on watchdog alert. Legal Values Values in range 60–720 Default Value 480 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency If the iDRAC.ServiceModule.WatchdogState object is ‘Disabled’, then the value cannot be set. iDRAC.ServiceModule.
iDRAC.SmartCard.SmartCardLogonEnable (Read or Write) Description Enables or disables Smart card login support. Legal Values • • • Write Privilege Configure iDRAC and Configure User License Required iDRAC7 Enterprise Dependency Disable ActiveDirectory.SSOEnable 0 — Disabled 1 — Enabled 2 — Enabled with Remote RACADM iDRAC.SNMP The objects in this group enable you to configure the SNMP agent and trap capabilities. iDRAC.SNMP.
iDRAC.SNMP.AlertPort (Read or Write) Description Specifies the SNMP alert port for traps. Legal Values Integral values: 1–65535 Default Value 162 Write Privilege Configure iDRAC License Required iDRAC7 Express Dependency None iDRAC.SNMP.DiscoveryPort (Read or Write) Description Specifies the SNMP agent port on iDRAC. Legal Values Integral values: 1–65535 Default Value 161 Write Privilege Configure iDRAC License Required iDRAC7 Express Dependency None iDRAC.SNMP.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.SNMP.Alert The objects in this group configures the SNMP alert settings. This group is indexed from 1 to 8. iDRAC.SNMP.Alert.DestAddr (Read or Write) Description IPv4, IPv6 or FQDN address of the target destination to receive alters. Legal Values Valid IPv4 or IPv6 or FQDN address Default Value • • Write Privilege Configure iDRAC License Required None Dependency None Index 1–4 — 0.0.0.0 Index 5–8 — :: iDRAC.SNMP.
Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.SSH.Port (Read or Write) Description Specifies the port number for the iDRAC SSH interface. Legal Values Integral values: 1–65535 Default Value 22 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.SSH.Timeout (Read or Write) Description Defines the secure shell idle timeout.
iDRAC.SysLog.PowerLogEnable (Read or Write) Description Enables or disables the Power Log feature. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.SysLog.PowerLogInterval (Read or Write) Description Configure time delay for power logging.
iDRAC.SysLog.Server3 (Read or Write) Description Name of remote syslog server 3. Legal Values String of up to 63 ACSII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.SysLog.SysLogEnable (Read or Write) Description Enables or disables remote syslog. Legal Values • • Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.
Default Value 23 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Telnet.Timeout (Read or Write) Description Defines the Telnet idle timeout. Legal Values Integral values: 0–10800 Default Value 1800 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Time The objects in this group enable you to manage timezone setting for iDRAC. iDRAC.Time.
Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Update The objects in this group enable you to manage configuration parameters for iDRAC firmware update. iDRAC.Update.FwUpdateIPAddr (Read or Write) Description Specifies the TFTP server address to be used for iDRAC firmware update operations.
iDRAC.UserDomain The objects in this group enable you to manage the Active Directory user domain names. This group is indexed from 1 to 40. iDRAC.UserDomain.Name (Read or Write) Description Specifies the Active Directory user domain name for a given index. Legal Values String of up to 255 ACSII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Users The objects in this group enable you to manage information about all iDRAC users.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Both user name and password must be configured prior to setting this object. iDRAC.Users.IpmiSerialPrivilege (Read or Write) Description Specifies the maximum IPMI Serial privilege.
iDRAC.Users.SNMPv3AuthenticationType (Read or Write) Description Configure SNMPv3 authentication protocol type. Legal Values • • • Default Value 2 — SHA Write Privilege Configure iDRAC and Configure User License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 0 — None 1 — MD5 2 — SHA iDRAC.Users.SNMPv3Enable (Read or Write) Description Enables or disables SNMPv3 support for an iDRAC User.
iDRAC.Users.SolEnable (Read or Write) Description Enables or Disables SOL for the user. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC and Configure User License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Both username and password must be configured prior to sets. 0 — Disabled 1 — Enabled iDRAC.Users.UserName (Read or Write) Description iDRAC User Name.
iDRAC.vflashpartition.AttachState (Read or Write) Description Legal Values Specifies if the vFlash SD partition is attached or detached. • • 1 — Attached 0 — Detached Default value 0 — Detached Write Privilege Login and configure iDRAC License Required iDRAC7 Enterprise Dependency vFlash SD card must be enabled. Partition at the specified index must be created. iDRAC.vflashpartition.EmulationType (Read or Write) Description Legal Values Specifies the emulation type of the vFlash SD partition.
iDRAC.vflashpartition.Size (Read Only) Description Specifies the Size of the vFlash SD partition. Legal Values Integer value in MB Default value None Write Privilege Login and configure iDRAC License Required iDRAC7 Enterprise Dependency vFlash SD card must be enabled. Partition at the specified index must be created. iDRAC.vflashpartition.VolumeLabel (Read Only) Description Specifies the label assigned to the partition during the vFlash SD partition creation.
Default value 0 — Disabled Write Privilege Login and configure iDRAC License Required iDRAC7 Enterprise Dependency vFlash SD card must be enabled. iDRAC.vflashsd.Health (Read Only) Description Legal Values Specifies current health status of the vFlash SD Card. • • • • OK Warning Critical Unknown Default value OK Write Privilege Login and configure iDRAC License Required iDRAC7 Enterprise Dependency vFlash SD card must be enabled. iDRAC.vflashsd.
Dependency vFlash SD card must be enabled. iDRAC.vflashsd.Size (Read Only) Description Specifies the remaining size of the vFlash SD card for usage. Legal Values Integer value in MB. Default value None Write Privilege Login and configure iDRAC License Required iDRAC7 Enterprise Dependency vFlash SD card must be enabled. iDRAC.vflashsd.WriteProtect (Read Only) Description Legal Values Displays if the physical write protect is enabled or disabled on the vFlash SD card.
iDRAC.VirtualConsole.Enable (Read or Write) Description Enables or disables the Virtual Console. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express (For Blades) or iDRAC7 Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.VirtualConsole.EncryptEnable (Read or Write) Description Encrypts the video in a Virtual Console session.
Default Value 4 Write Privilege Configure iDRAC License Required iDRAC7 Express (For Blades) or iDRAC7 Enterprise Dependency None iDRAC.VirtualConsole.PluginType (Read or Write) Description To use virtual console, when running from the browser specify the plugin type. Legal Values • • Default Value 0 — Active X Write Privilege Configure iDRAC License Required iDRAC7 Express (For Blades) or iDRAC7 Enterprise Dependency None 0 — Active X 1 — Java iDRAC.VirtualConsole.
iDRAC.VirtualMedia The objects in this group enable you to manage virtual media configuration parameters of iDRAC. iDRAC.VirtualMedia.Attached (Read or Write) Description Used to attach virtual devices to the system using the USB bus. Legal Values • • • Default Value 2 — AutoAttach Write Privilege Virtual Media License Required iDRAC7 Express (For Blades) or iDRAC7 Enterprise Dependency None 0 — Detached 1 — Attached 2 — AutoAttach iDRAC.VirtualMedia.
iDRAC.VNCServer The objects in this group manages configuration of the VNC Server on iDRAC. iDRAC.VNCServer.Enable (Read or Write) Description Legal Values Enables or disables VNC server on iDRAC. • • 0 — Disabled 1 — Enabled Default value 0 — Disabled Write Privilege Login or configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.VNCServer.LowerEncryptionBitLength (Read or Write) Description Legal Values Lower encryption bit length.
iDRAC.VNCServer.Port (Read or Write) Description Port number for VNC session Legal Values Integer values from 1024 to 65535 Default Value 5901 Write Privilege Login or configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.VNCServer.Timeout (Read or Write) Description VNC server idle timeout period in seconds.
Default Value 80 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.WebServer.HttpsPort (Read or Write) Description Specifies the port number for HTTPs communication with the iDRAC. Legal Values Integral values: 1–65535 Default Value 443 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Webserver.
iDRAC.WebServer.Timeout (Read or Write) Description Defines the webserver timeout. Legal Values Integral values: 60–10800 Default Value 1800 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.BiosBootSettings You can manage the BIOS start settings using the objects in this group. BIOS.BiosBootSettings.BootSeq (Read or Write) Description Determines the Bios start sequence of the system.
Dependency None BIOS.BiosBootSettings.HddSeq (Read or Write) Description HDD boot sequence Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if Boot mode is set to UEFI BIOS.BiosBootSettings.UefiBootSeq (Read or Write) Description UEFI boot sequence Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if Boot mode is set to BIOS BIOS.
• Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.IntegratedDevices.EmbNic2 (Read or Write) Description Legal Values Enables or disables the operating system interface of the embedded NIC2. • • • • Enabled EnabledPxe EnablediScsi Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.IntegratedDevices.
Dependency None BIOS.IntegratedDevices.EmbNic4 (Read or Write) Description Legal Values Enables or disables the operating system interface of the embedded NIC4. • • • • Enabled EnabledPxe EnablediScsi Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.IntegratedDevices.EmbVideo (Read or Write) Description Legal Values Enables or disables the BIOS support for the embedded video controller.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.IntegratedDevices.IntegratedRaid (Read or Write) Description Legal Values Enables or disables the integrated RAID controller. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.IntegratedDevices.IntegratedSas (Read or Write) Description Legal Values Enables or disables the integrated SAS controller.
• Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if 'InternalSdCard' is set to 'Off'. BIOS.IntegratedDevices.InternalUsb (Read or Write) Description Legal Values Enables or disables the internal USB port. • • On Off Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.IntegratedDevices.
BIOS.IntegratedDevices.IoatEngine (Read/Write) Description Legal Values Enables or disables the I/O Acceleration technology (I/OAT) option. • • Enabled Disabled License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.IntegratedDevices.MmioAbove4GB (Read/Write) Description Legal Values Enables or disables support for PCIe devices that require large amount of memory. Enable this option only for 64-bit operating systems.
BIOS.IntegratedDevices.UsbPorts (Read or Write) Description Legal Values Sets the user accessible USB ports. • • • All on Only back ports on All off Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MemSettings To manage memory-related configuration settings, use the objects in this group. BIOS.MemSettings.MemLowPower (Read or Write) Description Legal Values Enables or disables the low-power mode of the memory.
BIOS.MemSettings.MemOptimizer (Read or Write) Description Legal Values Configure the memory optimizer setting. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MemSettings.MemOpVoltage (Read Only) Description Legal Values Operating voltage of memory. • • AutoVolt Volt15V Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MemSettings.
Dependency None BIOS.MemSettings.RedundantMem (Read or Write) Description Legal Values Enables or disables the redundant memory feature. • • • • • • Disabled Spare Mirror IntraNodeMirror DimmSpare Dddc Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MemSettings.
• Disabled License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MemSettings.SnoopFilter (Read or Write) Description Legal Values Enables or disables the snoop filter option. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MemSettings.SysMemSize (Read Only) Description Indicates the current amount of main memory in the system.
Dependency None BIOS.MemSettings.SysMemVolt (Read Only) Description Displays the current operating voltage of main memory. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MemSettings.VideoMem (Read Only) Description Indicates the total amount of video memory available to the embedded video controller.
Dependency None BIOS.MiscSettings.InSystemCharacterization (Read/Write) Description Legal Values The ratio of power and performance of the system is optimized when enabled. • • Enabled Disabled License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MiscSettings.
Dependency None BIOS.OneTimeBoot You can manage the one time boot settings using the objects in this group. BIOS.OneTimeBoot.OneTimeBootMode (Read or Write) Description Legal Values Configure the one time boot mode setting. • • • • Disabled OneTimeBootSeq OneTimeHddSeq OneTimeUefiBootSeq Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.OneTimeBoot.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if OneTimeBootMode is not set to OneTimeHddSeq BIOS.OneTimeBoot.OneTimeUefiBootSeqDev (Read or Write) Description Configure the one time UEFI Boot Sequence device. Legal Values NIC or Optical Device list Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if OneTimeBootMode is not set to OneTimeUefiBootSeq BIOS.
• Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.DcuStreamerPrefetcher (Read or Write) Description Legal Values Enables or disables Data Cache Unit (DCU) Streamer Prefetcher. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.Proc1Id (Read Only) Description Provides the processor's family model and stepping values. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.Proc1L2Cache (Read Only) Description Amount of memory in the corresponding processor cache.
BIOS.ProcSettings.Proc2Brand (Read Only) Description Provides the processor brand name. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.Proc2Id (Read Only) Description Processor's family model and stepping values. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.Proc2L2Cache (Read Only) Description AmountBIOS.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.Proc3Brand (Read Only) Description Brand text provided by the processor manufacturer. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.Proc3Id (Read Only) Description Processor's family model and stepping values.
BIOS.ProcSettings.Proc3NumCores (Read Only) Description Number of cores in the processor package. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.Proc4Brand (Read Only) Description The processor manufacturer provides brand text Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.Proc4NumCores (Read Only) Description Number of cores in the processor package. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.Proc64bit (Read Only) Description Specifies whether the installed processors support 64-bit extensions.
BIOS.ProcSettings.ProcCores (Read or Write) Description Legal Values Controls the number of enabled cores in each processor. • • • • • • • • • • • Single All 1 2 4 6 8 10 12 14 16 Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.ProcCoreSpeed (Read Only) Description Clock speed of the processor. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.
BIOS.ProcSettings.ProcExecuteDisable (Read or Write) Description Legal Values Specifies whether Execute Disable Memory Protection Technology is enabled or disabled. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.ProcHpcMode (Read or Write) Description Legal Values Configure processor's HPC mode.
Dependency None BIOS.ProcSettings.ProcHyperTransport (Read or Write) Description Legal Values Specifies the supported HyperTransport I/O Link Specification. • • HT1 HT3 Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.ProcSoftwarePrefetcher (Read or Write) Description Legal Values Enables or disables the hardware prefetcher for considering software prefetches when detecting strides for prefetch requests.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.QpiSpeed (Read or Write) Description Legal Values Controls QuickPath Interconnect data rate settings. • • • • MaxDataRate 8 GTps 7 GTps 6 GTps Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.RtidSetting (Read or Write) Description Legal Values Allocates more RTIDs to the remote socket increasing cache performance between the sockets.
BIOS.SataSettings.eSataPort1 (Read or Write) Description Legal Values Sets the drive type of the selected device. • • Off Auto Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.eSataPort1Capacity (Read Only) Description Displays the total capacity of a hard-disk drive. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.
BIOS.SataSettings.SataPortA (Read or Write) Description Legal Values Sets the drive type of the selected device. • • Off Auto Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortACapacity (Read Only) Description Displays the total capacity of a hard-disk drive.
BIOS.SataSettings.SataPortB (Read or Write) Description Legal Values Sets the drive type of the selected device. • • Off Auto Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortBCapacity (Read Only) Description Displays the total capacity of a hard-disk drive.
BIOS.SataSettings.SataPortC (Read or Write) Description Legal Values Sets the drive type of the selected device. • • Off Auto Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortCCapacity (Read Only) Description Displays the total capacity of a hard-disk drive.
BIOS.SataSettings.SataPortD (Read or Write) Description Legal Values Sets the drive type of the selected device. • • Off Auto Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortDCapacity (Read Only) Description Displays the total capacity of a hard-disk drive.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortE (Read or Write) Description Legal Values Sets the drive type of the selected device. • • Off Auto Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortECapacity (Read Only) Description Displays the total capacity of a hard-disk drive.
• Auto Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortFCapacity (Read Only) Description Displays the total capacity of a hard-disk drive. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortFDriveType (Read Only) Description Indicates type of device attached to this SATA port.
BIOS.SataSettings.SataPortGCapacity (Read Only) Description Displays the total capacity of a hard-disk drive. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortGDriveType (Read Only) Description Indicates type of device attached to this SATA port. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortHDriveType (Read Only) Description Indicates type of device attached to this SATA port. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortHModel (Read Only) Description Displays the drive model of the selected device.
• • Serial2 RemoteAccDevice Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SerialCommSettings.FailSafeBaud (Read or Write) Description Legal Values BIOS attempts to determine the baud rate automatically. This fail-safe baud rate is used only if the attempt is unsuccessful. • • • • 115200 57600 19200 9600 Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SerialCommSettings.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SerialCommSettings.SerialPortAddress (Read or Write) Description Legal Values Port address for the Serial Devices. (COM1=0x3F8 COM2=0x2F8) • • • • Serial1Com1Serial2Com2 Serial1Com2Serial2Com1 Com1 Com2 Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SlotDisablement To manage the slot disablement settings, use the objects in this group. BIOS.SlotDisablement.
BIOS.SlotDisablement.Slot3 (Read or Write) Description Legal Values Control the configuration of the card installed in slot 3. • • • Enabled Disabled BootDriverDisabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SlotDisablement.Slot4 (Read or Write) Description Legal Values Control the configuration of the card installed in slot 4.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SlotDisablement.Slot7 (Read or Write) Description Legal Values Control the configuration of the card installed in slot 7. • • • Enabled Disabled BootDriverDisabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysInformation To view information about system configuration, use the objects in this group. BIOS.SysInformation.
BIOS.SysInformation.SystemCpldVersion (Read Only) Description Displays the current revision of the system CPLD firmware. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysInformation.SystemManufacturer (Read Only) Description Provides the name of the Original Equipment Manufacturer of this system.
BIOS.SysProfileSettings.CollaborativeCpuPerfCtrl (Read/Write) Description Legal Values Enables or disables the CPU power management control. When ProcPwrPerf is not set to SysDbpm in Custom mode, changing this setting does not affect system performance. • • Enabled Disabled License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Enabled only when SysProfileSettings.ProcPwrPerf is set to SysDbpm in Custom mode. BIOS.SysProfileSettings.
BIOS.SysProfileSettings.MemPwrMgmt (Read or Write) Description Legal Values Enables or disables the memory to operate in power management mode. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysProfileSettings.MemRefreshRate (Read or Write) Description Legal Values Frequency at which memory is normally refreshed.
BIOS.SysProfileSettings.PowerDelivery (Read or Write) Description Legal Values Sets the power delivery mode. • • MaxReliability MinPwr Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysProfileSettings.ProcC1E (Read or Write) Description Legal Values When enabled, the processor is allowed to switch to minimum performance state when idle.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.ProcTurboMode (Read or Write) Description Legal Values When enabled, the processor can operate in Turbo Boost Mode. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if SysSecurity.AcPwrRcvry is set to Off. BIOS.SysSecurity.AcPwrRcvryDelay (Read or Write) Description Legal Values Specifies how the system supports the staggering of power-up after AC power has been restored to the system. • • • Immediate User Random Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysSecurity.
• • Limited Locked License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysSecurity.IntelTxt (Read or Write) Description Enables or disables Trusted Execution technology. NOTE: When the IntelTxt value is set to ‘on’, then the following values are set: TpmActivation=NoChange (Pending Value=NoChange), TpmClear=No (Pending Value=No), TpmSecurity=OnPbm (Pending Value=OnPbm).
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysSecurity.PwrButton (Read or Write) Description Legal Values Enables or disables the power button on the front panel. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysSecurity.SetupPassword (Read or Write) Description Set up the system password.
To enable password modification, J_EN_PASSWD must be installed. To clear the already configured password, use the option available under F2 (system setup) during system start. Legal Values String of up to 22 characters Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysSecurity.TcmActivation (Read or Write) Description Legal Values Set the operational state of the Trusted Cryptography Module (TCM).
BIOS.SysSecurity.TpmActivation (Read or Write) Description Legal Values Specify the operational state of the Trusted Platform Module (TPM). • • • NoChange Activate Deactivate Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if SysSecurity.TpmSecurity is set to Off. BIOS.SysSecurity.TpmClear (Read or Write) Description Legal Values Warns that clearing the TPM causes loss of all keys in the TPM. It may affect starting the operating system.
Dependency None NIC.DCBSettings The following section provides information about the objects in the NIC.DCBSettings group. NIC.DCBSettings.CongestionNotification (Read Only) Description Legal Values Indicates whether Congestion Notification capability is supported. • • Available Unavailable Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.DCBSettings.
• Unavailable Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.DeviceLevelConfig To manage the device level configurations, use the objects in this group. NIC.DeviceLevelConfig.EVBModesSupport (Read Only) Description Legal Values Indicates the type of EVB Modes supported. • • • • VEB VEPA PE Multichannel Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.DeviceLevelConfig.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency` None NIC.FCOECapabilities The following section provides information about the objects in the NIC.FCOECapabilities group. NIC.FCOECapabilities.AddressingMode (Read Only) Description Legal Values Indicates whether SPMA or FPMA addressing is used for FCoE transactions. • • SPMA FPMA Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FCOECapabilities.MaxNumberExchanges (Read Only) Description Indicates the maximum number of exchanges supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FCOECapabilities.MaxNumberLogins (Read Only) Description Indicates the maximum number of logins supported per port.
NIC.FCOECapabilities.MTUReconfigurationSupport (Read Only) Description Legal Values Indicates whether the MTU reconfiguration capability is supported. • • Available Unavailable Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FCoEConfiguration The following section provides information about the objects in the NIC.FCoEConfiguration group. NIC.FCoEConfiguration.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FCoEConfiguration.FirstFCoEWWPNTarget (Read or Write) Description World Wide Port Name (WWPN) of the first FCoE storage target. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FCoEConfiguration.MTUParams (Read or Write) Description Legal Values Configure the MTU setting.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FCoEGenParams.FCoEFabricDiscoveryRetryCnt (Read or Write) Description Retry count for FCoE fabric discovery. Legal Values Values: 0–60 Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FCoEGenParams.FCoEFirstHddTarget (Read or Write) Description Legal Values Specifies whether the FCoE target is represented as the first HDD to the system.
Dependency None NIC.FCoEGenParams.FCoETgtBoot (Read or Write) Description Legal Values Enables the FCoE initiator to start system to the FCoE target. • • Enabled Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FrmwImgMenu The following section provides information about the objects in the NIC.FrmwImgMenu group. NIC.FrmwImgMenu.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.GlobalBandwidthAllocation The following section provides information about the objects in the NIC.GlobalBandwidthAllocation group. NIC.GlobalBandwidthAllocation.MaxBandwidth (Read or Write) Description Set the maximum percentage of port TX bandwidth allocated to partition.
Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiFirstTgtParams.FirstTgtBootLun (Read or Write) Description Set the first iSCSI storage target boot Logical Unit Number (LUN). Legal Values Values: 0–18446744073709551615 Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiFirstTgtParams.
NIC.IscsiFirstTgtParams.FirstTgtIscsiName (Read or Write) Description Set the iSCSI Qualified Name (IQN) of the first iSCSI storage target. Legal Values String of upto 223 ASCII characters NOTE: The legal value range may be smaller than the maximum size of 223, based on the vendor configuration of the NIC cards. Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiFirstTgtParams.
• Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.IscsiGenParams.DhcpVendId (Read or Write) Description Control what Vendor ID is presented to the DHCP service. Legal Values String of upto 255 ASCII characters Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.
NIC.IscsiGenParams.IpVer (Read or Write) Description Legal Values Controls whether IPv4 or IPv6 network addressing is used for iSCSI initiator and targets. • • • Ipv4 Ipv6 None Default Value Ipv4 Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.IscsiViaDHCP (Read or Write) Description Legal Values Enables the acquisition of iSCSI target parameters from DHCP.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.TcpIpViaDHCP (Read or Write) Description Legal Values Setting to enable acquisition of IPv4 TCP/IP parameters from DHCP. • • Enabled Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not Available if IscsiGenParams.IpVer is set to 'IPv6' and VndrConfigGroup.
NIC.IscsiInitiatorParams The following section provides information about the objects in the NIC.IscsiInitiatorParams group. NIC.IscsiInitiatorParams.IscsiInitiatorChapId (Read or Write) Description Set the iSCSI initiator Challenge-Handshake Authentication Protocol (CHAP) ID. Legal Values String of up to 128 characters Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.
NIC.IscsiInitiatorParams.IscsiInitiatorName (Read or Write) Description Specifies the initiator iSCSI Qualified Name (IQN). Legal Values String of upto 223 characters Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiInitiatorParams.IscsiInitiatorPrimDns (Read or Write) Description Specifies the Primary DNS IP address of the iSCSI initiator.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondaryDeviceParams The following section provides information about the objects in the NIC.IscsiSecondaryDeviceParams group. NIC.IscsiSecondaryDeviceParams.SecondaryDeviceMacAddr (Read or Write) Description Specifies the MAC address of a secondary iSCSI boot adapter for redundancy in case if start is unsuccessful.
NIC.IscsiSecondTgtParams To configure the iSCSIsecond storage, use the objects in this group. NIC.IscsiSecondTgtParams.ConnectSecondTgt (Read or Write) Description Legal Values Enables connecting to the second iSCSI target. • • Enabled Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondTgtParams.
Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondTgtParams.SecondTgtIpAddress (Read or Write) Description Specifies the IP address of the second iSCSI target. Legal Values String of 2-39 characters (Ipv4 or Ipv6 address) Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondTgtParams.
• • iSCSIPrimary iSCSI Secondary Default Value None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.NICConfig.LnkSpeed (Read or Write) Description Legal Values Specifies the port speed used for the selected boot protocol. • • • • • AutoNeg 10 Mbps Half 10 Mbps Full 100 Mbps Half 100 Mbps Full Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.NICConfig.
Dependency None NIC.NICConfig.WakeOnLan (Read or Write) Description Legal Values Enables the server to be powered on using an in-band magic packet. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.NICConfig.WakeOnLanLnkSpeed (Read or Write) Description Legal Values Select the port speed used for Wake on LAN mode.
NIC.NICPartitioningConfig.NumberPCIEFunctionsEnabled (Read Only) Description Indicates the number of physical PCIe functions currently enabled on this port. Legal Values Values: 1–65535 Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.NICPartitioningConfig.NumberPCIEFunctionsSupported (Read Only) Description Indicates the number of physical PCIe functions supported on this port.
NIC.VndrConfigGroup.ChipMdl (Read Only) Description Indicates the chip type or revision. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.EnergyEfficientEthernet (Read Only) Description Indicates whether Energy Efficient Ethernet capability is supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.
• Disabled Default Value Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.FCoEOffloadSupport (Read Only) Description Indicates whether FCoE Offload capability is supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.iSCSIBootSupport (Read Only) Description Indicates whether iSCSI Boot capability is supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.ISCSIMacAddr (Read Only) Description Indicates the permanent MAC address for iSCSI offload assigned during manufacturing.
NIC.VndrConfigGroup.LinkStatus (Read Only) Description Indicates the physical network link status that reports the controller. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.MacAddr (Read Only) Description Indicates the permanent MAC address assigned during manufacturing.
NIC.VndrConfigGroup.NWManagementPassThrough (Read Only) Description Indicates whether the Network Management Pass Through capability is supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.OnChipThermalSensor (Read Only) Description Indicates whether an on-chip thermal sensor is available.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.RemotePHY (Read Only) Description Indicates whether RemotePHY capability is supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.RXFlowControl (Read Only) Description Indicates whether Receive (RX) Flow control capability is supported.
NIC.VndrConfigGroup.TXBandwidthControlMinimum (Read Only) Description Indicates whether Transmit (TX) Bandwidth Control Minimum capability is supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.TXFlowControl (Read Only) Description Indicates whether Transmit (TX) Flow Control capability is supported.
NIC.VndrConfigGroup.VirtMacAddr (Read or Write) Description Programmatically assignable MAC address. Programmatic write for support of I/O Identity feature. Legal Values String of up to 17 characters Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.VirtualLinkControl (Read or Write) Description Indicates whether Virtual Link Control capability is supported.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.WWPN (Read Only) Description Fibre Channel World Wide Port Name identifier for FCoE. Legal Values String of up to 23 characters Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None Storage.Controller The objects in this group manage storage controller attributes. The following sections provide information about the objects in this group. Storage.Controller.
Storage.Controller.CheckConsistencyMode (Read or Write) Description Legal Values Check Consistency feature is used to verify the accuracy of the redundant (parity) information. • • Normal Stop On Error Default value Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None Storage.Controller.
• • ON with SMART Off Default value Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None Storage.Controller.EnhancedAutoImportForeignConfig (Read or Write) Description Legal Values This property indicates the Enhanced Auto Import of Foreign Configuration setting on the controller. • • Disabled Enabled Default value Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None Storage.Controller.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None Storage.Controller.PossibleloadBalancedMode (Read or Write) Description Legal Values This attribute represents the ability to automatically use both controller ports connected to the same enclosure to route I/O requests. • • Auto Disabled Default value Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None Storage.Controller.
Storage.Controller.SupportControllerBootMode (Read Only) Description Legal Values This is readonly attribute. This property indicates if this controller supports setting of controller boot mode. • • Supported Not Supported Default value Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None Storage.Controller.SupportEnhancedAutoForeignImport (Read Only) Description Legal Values This is readonly attribute.
Storage.Controller.T10PICapability (Read Only) Description Legal Values This is readonly attribute. This property indicates if this controller supports T10 PI. • • Incapable Capable Default value Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None Storage.PhysicalDisk The objects in this group manage storage physical disk drive attributes. The following section provides information about the objects in this group. Storage.PhysicalDisk.
Storage.PhysicalDisk.RaidNominalMediumRotationRate (Read Only) Description This is readonly attribute and represents the nominal medium rotation speed of a physical disk drive. Legal Values Values: 2–4294967295 Default value Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None Storage.PhysicalDisk.T10PICapability (Read Only) Description Legal Values This is readonly attribute. This property indicates if this physical disk drive supports T10 PI.
cache before writing it to the physical disk drive. Because it is faster to write data to the cache than to a disk, enabling this feature can improve system performance. Legal Values • • • Default Enabled Disabled Default value Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None Storage.VirtualDisk.
Storage.VirtualDisk.WritePolicy (Read or Write) Description Legal Values The write policies specify whether or not the controller sends a write-request completion signal as soon as the data is in the cache or after it has been written to disk.