iDRAC9 with Lifecycle Controller Version 3.00.00.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Introduction............................................................................................................................... 32 New in this release.............................................................................................................................................................. 32 Supported RACADM Interfaces........................................................................................................................................
getsensorinfo....................................................................................................................................................................... 69 getssninfo............................................................................................................................................................................. 73 getsvctag....................................................................................................................................
update..................................................................................................................................................................................145 usercertupload....................................................................................................................................................................149 usercertview..................................................................................................................................
cfgEmailAlertCustomMsg (Read or Write)...............................................................................................................163 cfgEmailAlertEmailName (Read Only).......................................................................................................................163 cfgSessionManagement....................................................................................................................................................
cfgSDWriteProtect (Read Only) ............................................................................................................................... 174 cfgServerInfo......................................................................................................................................................................174 cfgServerName (Read Or Write)...............................................................................................................................
cfgIpmiSolBaudRate (Read or Write)........................................................................................................................184 cfgIpmiSolMinPrivilege (Read or Write)....................................................................................................................184 cfgIpmiSolAccumulateInterval (Read or Write)....................................................................................................... 184 cfgIpmiSolSendThreshold (Read or Write).....
cfgServerPowerLastWeekMinPower (Read Only)..................................................................................................193 cfgServerPowerLastWeekMinTime (Read Only).................................................................................................... 193 cfgServerPowerLastWeekMaxPower (Read Only).................................................................................................193 cfgServerPowerLastWeekMaxTime (Read Only)......................................
cfgIPv6StaticDNSServersFromDHCP6 (Read or Write).......................................................................................202 cfgIPv6StaticDNSServer1 (Read or Write)............................................................................................................. 202 cfgIPv6StaticDNSServer2 (Read or Write).............................................................................................................202 cfgIPv6DNSServer2 (Read or Write)...................................
cfgRacSecCsrOrganizationName (Read or Write)..................................................................................................212 cfgRacSecCsrOrganizationUnit (Read or Write).....................................................................................................212 cfgRacSecCsrLocalityName (Read or Write).......................................................................................................... 213 cfgRacSecCsrStateName (Read or Write).............................
System. pcieSlotLFM.SlotState (Read)................................................................................................................... 227 System. pcieSlotLFM.TargetLFM............................................................................................................................. 227 System.Power....................................................................................................................................................................227 System.Power.
System.Power.Supply.[i].Status (Read Only)..........................................................................................................240 System.Power.Supply.[i].Type (Read Only)............................................................................................................ 240 System.Power.Supply.[i].LineStatus (Read Only)................................................................................................... 241 System.Power.Supply.[i].PMBusMonitoring (Read Only)......
iDRAC.ActiveDirectory..................................................................................................................................................... 253 iDRAC.ActiveDirectory.AuthTimeout (Read or Write)........................................................................................... 253 iDRAC.ActiveDirectory.CertValidationEnable (Read or Write)..............................................................................253 iDRAC.ActiveDirectory.
iDRAC.IPBlocking.RangeAddr (Read or Write)....................................................................................................... 265 iDRAC.IPBlocking.RangeEnable (Read or Write).................................................................................................... 265 iDRAC.IPBlocking.RangeMask (Read or Write)...................................................................................................... 265 iDRAC.IPMILan...................................................
iDRAC.IPv6.Address 8 (Read or Write).................................................................................................................... 277 iDRAC.IPv6.Address 9 (Read or Write).................................................................................................................... 277 iDRAC.IPv6.Address10 (Read or Write)................................................................................................................... 278 iDRAC.IPv6.Address11 (Read or Write)......
iDRAC.NIC.Autoneg (Read or Write)........................................................................................................................289 iDRAC.NIC.DedicatedNICScanTime (Read or Write).............................................................................................290 iDRAC.NIC.DNSDomainFromDHCP (Read or Write)............................................................................................. 290 iDRAC.NIC.DNSDomainName (Read or Write)................................
iDRAC.RSM.RSMCapability (Read Only)..................................................................................................................301 iDRAC.RSM.RSMSetting (Read Only)..................................................................................................................... 302 iDRAC.Security.................................................................................................................................................................. 302 iDRAC.Security.
iDRAC. SupportAssist.DefaultPassword................................................................................................................... 313 iDRAC. SupportAssist. DefaultProtocol.................................................................................................................... 314 iDRAC. SupportAssist.DefaultShareName................................................................................................................314 iDRAC.SupportAssist.DefaultUserName..........
iDRAC.USB.ManagementPortMode (Read only)................................................................................................... 325 iDRAC.USB.PortStatus...............................................................................................................................................325 iDRAC.USB.ZipPassword (Read and Write)............................................................................................................325 iDRAC.UserDomain...................................
iDRAC.VNCServer.Enable (Read or Write)............................................................................................................. 336 iDRAC.VNCServer.Enable (Read or Write)..............................................................................................................337 iDRAC.VNCServer.LowerEncryptionBitLength (Read or Write).......................................................................... 337 iDRAC.VNCServer.Password (Read or Write).................................
BIOS.EmbServerMgmt.FrontLcd (Read or Write)................................................................................................. 350 BIOS.EmbServerMgmt.UserLcdStr (Read or Write)............................................................................................. 350 BIOS.MemSettings........................................................................................................................................................... 350 BIOS.MemSettings.MemLowPower (Read or Write)....
BIOS.ProcSettings.Proc1L2Cache (Read or Write)................................................................................................362 BIOS.ProcSettings.Proc1L3Cache (Read or Write)................................................................................................362 BIOS.ProcSettings.Proc1NumCores (Read or Write)............................................................................................ 363 BIOS.ProcSettings.Proc2Brand (Read or Write)................................
BIOS.PxeDev1Settings.PxeDevnVlanPriority (Read or Write).............................................................................. 376 BIOS.SataSettings.............................................................................................................................................................376 BIOS.SataSettings.eSataPort1 (Read or Write)...................................................................................................... 376 BIOS.SataSettings.
BIOS.SerialCommSettings.FailSafeBaud (Read or Write)..................................................................................... 388 BIOS.SerialCommSettings.RedirAfterBoot (Read or Write)..................................................................................388 BIOS.SerialCommSettings.SerialComm (Read or Write)....................................................................................... 389 BIOS.SerialCommSettings.SerialPortAddress (Read or Write)...............................
BIOS.SysSecurity.NmiButton (Read or Write)........................................................................................................402 BIOS.SysSecurity.PasswordStatus (Read or Write).............................................................................................. 402 BIOS.SysSecurity.PwrButton (Read or Write)........................................................................................................403 BIOS.SysSecurity.SecureBoot (Read or Write).......................
FC.PortConfig.DeviceName (Read Only)................................................................................................................. 414 FC.PortConfig.FCDevice (Read Only)...................................................................................................................... 415 FC.PortConfig.FCTarget (Read Only).......................................................................................................................415 FC.PortConfig.HBAConfig (Read Only).........
NIC.FCoEConfiguration.BootOrderFirstFCoETarget (Read or Write).................................................................426 NIC.FCoEConfiguration.BootOrderFourthFCoETarget (Read or Write)............................................................. 426 NIC.FCoEConfiguration.BootOrderSecondFCoETarget (Read or Write)............................................................427 NIC.FCoEConfiguration.BootOrderThirdFCoETarget (Read or Write)...............................................................
NIC.IscsiInitiatorParams.IscsiInitiatorChapPwd (Read or Write).......................................................................... 439 NIC.IscsiInitiatorParams.IscsiInitiatorGateway (Read or Write)............................................................................ 439 NIC.IscsiInitiatorParams.IscsiInitiatorIpAddr (Read or Write)................................................................................ 439 NIC.IscsiInitiatorParams.IscsiInitiatorName (Read or Write).......................
NIC.VndrConfigGroup.FlexAddressing (Read Only)................................................................................................451 NIC.VndrConfigGroup.iSCSIBootSupport (Read Only)......................................................................................... 452 NIC.VndrConfigGroup.ISCSIMacAddr (Read Only)................................................................................................452 NIC.VndrConfigGroup.iSCSIOffloadMode (Read or Write)............................
Storage.enclosure.BackplaneCurrentMode (Read Only).......................................................................................464 Storage.enclosure.BackplaneRequestedMode (Read or Write)........................................................................... 464 Storage.enclosure.BackplaneType (Read Only)......................................................................................................464 storage.enclosure.supportedSplitModes(Read Only)......................................
1 Introduction This document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object definitions for iDRAC for the Dell EMC servers. Topics: • • • • • • • New in this release Supported RACADM Interfaces RACADM Syntax Usage Unsupported RACADM Subcommands Other Documents You May Need Accessing documents from Dell support site Contacting Dell New in this release • • • • • • • Added iDRAC.
SSH, Telnet, or Remote RACADM racadm -r -u username -p password racadm -r -u username -p password getconfig -g -o
LegacyBootProto=NONE LnkSpeed=AutoNeg #VLanId=1 VLanMode=Disabled • To display a single object for the specified group, run: racadm get device...
closessn clrraclog . . . . . . . vflashsd vflashpartition vmdisconnect cd quit • Example 2: racadm> get get getconfig getled getniccfg getraclog getractime getsel getsensorinfo getssninfo getsvctag getsysinfo gettracelog getversion • Example 3: racadm> getl racadm> getled or LEDState: Not-Blinking • Example 4: racadm>> get bios.uefiBootSettings BIOS.UefiBootSettings BIOS.UefiBootSettings.UefiBootSeq BIOS.UefiBootSettings.
Unsupported RACADM Subcommands The following table provides the list of RACADM subcommands which are not supported. Table 2. Unsupported RACADM Subcommands Subcommand iDRAC on Blade Servers Telnet/SSH/Serial krbkeytabupload No sslcertupload No sslkeyupload No usercertupload No Other Documents You May Need In addition to this guide, you can access the following guides available on the Dell Support website at www.dell.com/esmmanuals. To access the documents, click the appropriate product link.
A list of matching products is displayed. 3. Select your product and click the search icon or press enter. 4. Click Manuals & documents. Accessing documents using product selector You can also access documents by selecting your product. 1. 2. 3. 4. Go to www.dell.com/support. Click Browse all products. Click the desired product category, such as Servers, Software, Storage, and so on. Click the desired product and then click the desired version if applicable.
2 RACADM Subcommand Details This section provides detailed description of the RACADM subcommands including the syntax and valid entries. Topics: • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 38 Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands help and help subcommand arp autoupdatescheduler bioscert cd cd..
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • RACADM Proxy racdump racreset racresetcfg remoteimage rollback sensorsettings serveraction set setled setniccfg sshpkauth sslcertdownload sslcertupload sslcertview sslcertdelete sslcsrgen sslkeyupload sslresetcfg storage supportassist swinventory switchconnection systemconfig systemerase systemperfstatistics techsupreport testemail testtrap testalert traceroute traceroute6 update usercertupload usercertview vflashsd vflashpartition
• • # (pound) ASCII code 32 (space) There are different escaping rules for double quotation marks. For using double quotation marks: The following characters must be escaped by prepending a backward slash: • • • $ (dollar sign) " (double quotation marks) ` (back quotation marks) help and help subcommand Table 3. help and help subcommand Description Lists all the subcommands available for use with RACADM and provides a short description about each subcommand.
autoupdatescheduler Description You can automatically update the firmware of the devices on the server. To run this subcommand, you must have the Server Control privilege. NOTE: • The autoupdatescheduler subcommand can be enabled or disabled. • • Lifecycle Controller and CSIOR may not be enabled to run this subcommand. The autoupdatescheduler can be enabled or disabled. For more information, see LifecycleController,LCAttributes.
Input Valid options: • -u — Specifies the user name of the remote share that stores the catalog file. NOTE: For CIFS, enter the domain name as domain or username. • • • • • • • • • • • • -p — Specifies the password of the remote share that stores the catalog file. -l — Specifies the network share (NFS, CIFS, FTP, TFTP,HTTP, or HTTPS) location of the catalog file. IPv4 and IPv6 addresses are supported. -f — Specifies the catalog location and the filename.
Example Usage examples: • To configure autoupdate feature settings. • For CIFS, run the command: racadm autoupdatescheduler create -u domain/admin -p xxx -l //1.2.3.4/ share -f cat.xml -time 14:30 -wom 1 -dow sun -rp 1 -a 1 • For NFS, run the command: racadm autoupdatescheduler create -u nfsadmin -p nfspwd -l 1.2.3.4:/ share -f cat.xml -time 14:30 -dom 1 -rp 5 -a 1 • For FTP, run the command: racadm autoupdatescheduler create -u ftpuser -p ftppwd -l ftp.test.com -f cat.xml.gz -ph 10.20.30.
Synopsis • To view the installed Secure Boot Certificates racadm bioscert view –all • To export the Secure Boot Certificate to a remote share or local system.
Example • To view the installed Secure boot Certificates.
cd Description To change the current working object, use this command. Synopsis racadm> cd
Output Clears the last crash screen buffer. Example racadm clearasrscreen clearpending Description Deletes the pending values of all the attributes (objects) in the device (NIC, BIOS, FC, and Storage). NOTE: If any attribute is not modified or a job is already scheduled for the same device, then the pending state is not cleared or deleted.
Example • Closes the session 1234. racadm closessn -i 1234 • Closes all the sessions other then the active session for root user. racadm closessn –u root • Closes all the sessions. racadm closessn –a clrsel Description Removes all the existing records from the System Event Log (SEL). To use this subcommand, you must have Clear Logs permission. Synopsis Example racadm clrsel • racadm clrsel The SEL was cleared successfully config Table 4.
Input • -f—The -f option causes config to read the contents of the file specified by and configure iDRAC. The file must contain data in the format specified in the section Parsing Rules in the iDRAC User's Guide available at www.dell.com/idracmanuals. NOTE: The -f option is not supported for the Serial or telnet or SSH console. • -continue—This option is used with -f option only.
Synopsis Example racadm coredump • racadm coredump There is no coredump currently available. • racadm Feb 19 Feb 19 Feb 19 Feb 19 Feb 22 coredump 15:51:40 15:52:41 15:54:12 15:56:11 11:46:11 (none) (none) (none) (none) (none) last message last message last message last message kernel: repeated repeated repeated repeated 5 4 4 2 times times times times coredumpdelete Description Deletes any currently available coredump data stored in the RAC.
Input • —m —Specifies the type of diagnostic mode. The types are: • • • • • • • • Collect and export remote diagnostics report from the iDRAC. The results of the latest successfully executed remote Diagnostics will be available and retrievable remotely through the NFS, CIFS, HTTP, and HTTPS share. • 0(Express)—The express mode executes a subset of diagnostic tests. • 1(Extended)—The extended mode executes all available diagnostics tests.
Synopsis racadm eventfilters racadm eventfilters get -c racadm eventfilters set -c -a -n racadm eventfilters set -c -a -r racadm eventfilters test -i NOTE: The general format of an alert category: idrac.alert.category.[subcategory].[severity] where, category is mandatory, but subcategory and severity are optional. A severity cannot precede a subcategory.
Input • • • • • • • get — Displays the list of eventfilter settings. set — Configures the actions and notifications for a given eventfilter configuration. -i — Message ID for which the simulation is needed. -c — Alert category of the specific event filter. -a — The action that must be invoked when the event occurs. Valid values are none, powercycle, power off, or systemreset. -n — The notification is sent when the event occurs.
Example • Display all available event filter configurations. racadm eventfilters get -c idrac.alert.all • Display eventfilter configurations for a specific category. For example, audit. racadm eventfilters get -c idrac.alert.audit • Display eventfilter configurations for a specific subcategory. For example, licensing under the audit category. racadm eventfilters get -c idrac.alert.audit.lic • Display eventfilter configurations for a specific severity. For example, warning under the audit category.
exposeisminstallertohost Description Exposes the ISM installer to host OS Synopsis racadm exposeisminstallertohost Input Not Applicable Example Not Applicable fcstatistics Description Displays a list of FCs (FQDDs), managed server for which statistics is available. Synopsis Input racadm fcstatistics — Specify the FQDD of the target FC device.
Synopsis racadm fwupdate -s racadm fwupdate -g -u -a [-d [--clearcfg] racadm -r -u -p fwupdate -f -d where path is the location on the ftp server where firmimg.d7 is stored.
Example • Uploads a firmware image from the client and start firmware update: racadm fwupdate -p -u -d /tmp/images • Upload firmware image from FTP server and start firmware update: racadm fwupdate -f 192.168.0.10 test test -d firmimg.d7 • Upload firmware image from TFTP server and start firmware update: racadm fwupdate -g -u -a 192.168.0.
get Description Displays the value of one or more objects. The get subcommand has two forms. • • Displays the value of a single object. Exports the value of multiple objects to a file. It supports multiple object value exports in two file formats • • INI format—The INI format files can be exported to a local file only. Server Configuration Profile XML format—XML format files can be exported to a local file, to an NFS network share or to a CIFS network share.
Input • • Examples for FQDDs • • • • • • System.Power System.Power.Supply System.Location LifecycleController.LCAttributes System.LCD iDRAC.Serial For the list of supported groups and objects under the get command, see Database objects with get and set commands • • • • • • • • —Specifies the group containing the object that must be read. —Specifies the object name of the value that must be read. —Specifies where FQDD Aliases or Groups must be indexed.
Examples • Get system LCD information. racadm get system.lcdLCDUserString • Display an entire group, in this case the topology configuration. racadm get system.location • Display a single object from a particular group. racadm get system.location.rack.name • Export the xml configuration to a CIFS share. racadm get -f file -t xml -u myuser -p xxx -l //192.168.0/share • Export the xml configuration to an NFS share. racadm get -f file -t xml -l 192.168.
getconfig Table 5. Details of getconfig subcommand Description Retrieves iDRAC configuration parameters individually or all iDRAC configuration groups may be retrieved and saved to a file. NOTE: This subcommand is deprecated. For viewing the configuration objects and its values, use get subcommand. For more information, see the iDRAC RACADM CLI Guide available at www.dell.com/idracmanuals.
cfgUserAdmin cfgUserAdminUserName Groups Key Attributes cfgEmailAlert cfgEmailAlertAddress cfgLDAPRoleGrou p cfgLDAPRoleGroupDN cfgServerInfo cfgServerBmcMacAddress cfgStandardSche ma cfgSSADRoleGroupName cfgTraps cfgTrapsAlertDestIPAddr cfgUserAdmin cfgUserAdminUserName 62 RACADM Subcommand Details
Example • Displays the configuration properties (objects) that are contained in the group cfgLanNetworking. racadm getconfig -g cfgLanNetworking • Saves all group configuration objects from iDRAC to myrac.cfg. racadm getconfig -f myrac.cfg If you do not configure the following key attributes in their respective groups for a particular index, the groups are not saved in to the file. This is applicable for all the index groups. Saves all group configuration objects from iDRAC to myrac.cfg.
gethostnetworkinterfaces Description Displays host network interface details. NOTE: To run this subcommand, you must have iDRAC Service Module installed on the server operating system. Synopsis racadm gethostnetworkinterfaces racadm gethostnetworkinterfaces Examples • To display the details of all the network interfaces on the server.
Example racadm getled LED State : Blinking racadm getled LED State : Not-Blinking getniccfg Description Synopsis Displays the current and static NIC settings for iDRAC.
Output The getniccfg subcommand displays an appropriate error message if the operation is not successful. Otherwise, the output is displayed in the following format: NOTE: I IPv4 settings: NIC Enabled =1 IPv4 Enabled =1 DHCP Enabled =0 IP Address =10.94.227.207 Subnet Mask =255.255.255.0 Gateway =10.94.227.
Example • Display iDRAC network settings in server slot 1 racadm getniccfg getraclog Description Synopsis The getraclog command displays RAC log entries. • racadm getraclog [-i] • racadm getraclog [-s ] [-c ] racadm getraclog [-c ] [-s ] NOTE: If options are not provided, the entire log is displayed. Input • -c — Specifies the number of records to display. • -s — Specifies the starting record used for the display.
Example Display the recent 2 records for RAC log racadm getraclog -c 2 SeqNumber = 4102 Message ID = LIC201 Category = Audit AgentID = DE Severity = Warning Timestamp = 2017-05-15 06:30:20 Message = License yPMRJGuEf7z5HG8LO7gh assigned to device iDRAC expires in 4 days.
Input • • • • • • • • —i — Displays the number of entries in the SEL. -s — Displays the starting record number. -c — Specifies the number of records to display. --more — Displays a screen. -A — Does not display headers or labels. -o — Displays each record on a single line.. -E — Displays RAW SEL data along with the other data. -R — Displays only the RAW SEL data for each record Example • Display entire log. racadm getsel • Display number of records in log.
System Board Fan2 RPM Ok 6000 RPM 600 RPM NA 0% System Board Fan3 RPM Ok 5880 RPM 600 RPM NA 0% System Board Fan4 RPM Ok 5880 RPM 600 RPM NA 0% System Board Fan5 RPM Ok 5640 RPM 600 RPM NA 144% System Board Fan6 RPM Ok 5880 RPM 600 RPM NA 152% Sensor Type : VOLTAGE CPU1 VCORE PG Ok Good NA NA System Board 3.3V PG Ok Good NA NA System Board 5V AUX PG Ok Good NA NA CPU1 M23 VPP PG Ok Good NA NA System Board 1.
System Board DIMM PG Ok Good NA NA Sensor Type : CURRENT [R/W] [R/W] PS1 Current 1 Ok 0.
DIMM B12 N/A Absent NA NA Sensor Type : Chassis Controller Chassis Controller OK OK /tmp # vi idraclogs 4 23:09:39 idrac8 L4, 4 23:09:39 idrac8 L4, 4 23:09:39 idrac8 L4, 4 23:09:39 idrac8 L4, 4 23:09:39 idrac8 L4, 4 23:09:39 idrac8 L5, 4 23:09:40 idrac8 L4, 4 23:09:40 idrac8 L4, 4 23:09:40 idrac8 L4, 4 23:09:40 idrac8 L4, 4 23:09:40 idrac8 L4, 4 23:09:40 idrac8 L4, S3 S3 S3 S3 S3 S3 S3 S3 S3 S3 S3 S3 [2440]: sessionmanagement_dmmapping_thread() confd (2) [2440]: r
System Board MEM Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y] System Board SYS Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y] getssninfo Table 7. getssninfo Description Displays a list of users that are connected to iDRAC.
getsysinfo Description Displays information related to iDRAC, managed system, and watchdog configuration. NOTE: The hostname and OS Name fields in the getsysinfo output display accurate information only if the OpenManage Server Administrator (OMSA) is installed on the managed system. If OMSA is not installed these fields may be blank or inaccurate. An exception to this are VMware operating system names, which are displayed even if OMSA is not installed on the managed system.
System Information: System Model System Revision System BIOS Version Service Tag Express Svc Code Host Name OS Name OS Version Power Status Fresh Air Capable = = = = = = = = = = PowerEdge R630 I 1.3.6 62T3232 13230477902 WIN-2TA05N3JSLD Microsoft Windows Server 2008 R2, Enterprise x64 Edition Version 6.
Example • Display entire log racadm gettracelog • Display number of records in log racadm gettracelog -i Total Records: 228 getversion Description Displays the current software version, model and generation information, and whether the target device can be updated. Synopsis • • • racadm getversion racadm getversion [-b | -c | —i] racadm getversion [-f ] Input • • • • -c — Displays the server's current CPLD version. -b — Displays the server's current BIOS version.
server-1 1.6.0 PowerEdgeM520 server-2 6.3.0 PowerEdgeM610x server-4 7.0.0 PowerEdgeM710HD server-5 6.3.0 PowerEdgeM710 server-7 1.7.1 PowerEdgeM620 server-9 1.7.
Synopsis • To delete the group from the group manager. groupmanager delete –g • To remove the iDRAC from group by itself by using administrator privileges. groupmanager removeself –g • To join the group using administrator privileges.
NIC.Slot.
NIC Mode: FCoE Offload Mode: iSCSI Offload Mode: Max Number of IOs per session supported: Number of Max LOGINs per port: Max Number of exchanges: Max NPIV WWN per port: Number of Targets Supported: Max Number of outstanding commands supported across all sessions: Flex Addressing: UEFI: iSCSI Offload: iSCSI Boot: TCP OffloadEngine: FCoE: FCoE Boot: PXE Boot: SRIOV: Wake on LAN: Network Management Pass Through: OS2BMC PassThrough: Energy Efficient Ethernet: On Chip Thermal Sensor: NPar: Remote PHY: Feature Li
• To display the Standard hardware inventory verbose description for the FC.Slot.2–1, type the following command: racadm hwinventory FC.Slot.
Port Down Timeout: Link Down Timeout: Port Number: Port Speed: Max Number of IOs per connection supported: Maximum number of Logins per port: Maximum number of exchanges: Maximum NPIV per port: Maximum number of FC Targets supported: Maximum number of outstanding commands across Flex Addressing: UEFI: FC Start: On Chip Thermal Sensor: Feature Licensing: 0 30000 1 0 9 8 9 1 8 all connections: 9 Capable Capable Capable Capable Not Capable ifconfig Description Displays the contents of the network interface
Synopsis • racadm inlettemphistory export –f –t [–u ] [–p ] [-i ] • racadm inlettemphistory get This command does not support proxy parameters. To perform the operation with http and https, the proxy parameters has to be configured in the lifecyclecontroller.lcattributes. Once these proxy parameters are configured, they become the part of default configuration.
Example • Export the log to a remote CIFS share. racadm inlettemphistory export -f Mylog.xml -u admin -p xxx -l //1.2.3.4/ share -t xml • Export the log to a remote HTTP share. racadm inlettemphistory export -f Mylog.xml -u httpuser -p httppwd\n http://test.com -t xml • -l Export the log to a remote HTTPS share. racadm inlettemphistory export -f Mylog.xml -u httpsuser -p httpspwd\n https://test.com -t xml • -l Export the log to local file system using Local RACADM.
jobqueue Description Enables you to view and delete a job or jobs in the current Job Queue. NOTE: • • To run this subcommand, you must have the Server control privilege. If an unexpected error message is displayed for any operation, ensure you delete some jobs in the jobqueue and retry the operation. • Use jobqueue create command after applying a pending device configuration. Else, you may see a job creation and deletion in the lclog.
Example • View jobs in the current job queue. racadm jobqueue view • View status of a specific job ID. racadm jobqueue view -i • Issue configuration changes for a PERC controller then start a real time job to execute the changes. racadm set RAID.Slot.3-1.RAIDdefaultWritePolicy WriteBack racadm set RAID.Slot.3-1.Name “Prod Workload” racadm jobqueue create RAID.Slot.3-1 –realtime • Delete all possible jobs from the current job queue.
lclog Description Allows you to: • • • • • Export the lifecycle log history. The log exports to remote or local share location. View the lifecycle log for a particular device or category Add comment to a record in lifecycle log Add a work note (an entry) in the lifecycle log View the status of a configuration job. NOTE: • • Synopsis When you run this command on Local RACADM, the data is available to RACADM as a USB partition and may display a pop-up message.
Input • • • • • • • • • • • • • • • • -i — Displays the number of records present in the active log. -a — The agent ID used to filter the records. Only one agent ID is accepted. The value is case-insensitive. Valid Agent-ID values: • UEFI_SS_USC • CusOsUp • UEFI_Inventory • iDRAC • UEFI_DCS • SEL • RACLOG • DE • WSMAN • RACADM • iDRAC_GUI -c — The category used to filter the records. Provides multiple categories using a "," as the delimiter. The value is case-insensitive.
Example • Display the number of records present in the Lifecycle log. racadm lclog view -i • Display the iDRAC agent idrac records, under the storage category and storage physical disk drive subcategory, with severity set to warning. racadm lclog view -a idrac -c storage -b pdr -s warning • Display the records under storage and system categories with severities set to warning or critical.
license Description Synopsis Input Manages the hardware licenses.
• Import a license from a CIFS share to a device, in this case Embedded iDRAC. racadm license import -u admin -p xxx -f License.xml -l //192.168.0/licshare -c idrac.embedded.1 • Import a license from an NFS share to a device, in this case Embedded iDRAC. racadm license import -f Licen.xml -l 192.168.0:/share -c idrac.embedded.1 • Import a license by overriding the EULA warning. racadm license import -u admin -p passwd -f License.xml -l //192.168.0/licshare -c idrac.embedded.
• Delete licenses on a particular device, in this case Embedded iDRAC. racadm license delete -c idrac.embedded.1 • Delete a license using entitlement ID, in this case xYZabcdefg. racadm license delete -e xYZabcdefg • Delete a license using transaction ID, in this case 2. racadm license delete -t 2 netstat Description Display the routing table and network statistics.
• To display the statistics for the integrated NIC, type the following command: $ racadm nicstatistics NIC.Integrated.1-1 Total Bytes Received: Total Bytes Transmitted: 0 0 Total Unicast Bytes Received: Total Multicast Bytes Received: 0 Total Broadcast Bytes Received: 0 Total Unicast Bytes Transmitted: • 0 0 To get the network statistics, type the following command: $ racadm nicstatistics NIC.Slot.5-2-1 : QLogic CNA Gigabit Ethernet-B8:AC:6F:B3:BF:10 NIC.Slot.
Input — the IPv6 address of the remote endpoint to ping.
Synopsis Local RACADM proxy usage racadm --proxy Remote RACADM proxy usage racadm -u -p -r --proxy NOTE: • • The attribute racadm getconfig -g cfgractuning -o cfgRacTuneChassisMgmtAtServer must be set as non-zero in CMC. The attribute racadm get system.ChassisControl.ChassisManagementMonitoring attribute must be enabled in iDRAC. --proxy must be entered at the end of the command.
racdump Description Provides a single command to get dump, status, and general iDRAC board information. To run this subcommand, you must have the Debug permission.
DNS Servers from DHCPv6 = Disabled Current DNS Server 1 = :: Current DNS Server 2 = :: System Information: System Model System Revision System BIOS Version Service Tag Express Svc Code Host Name OS Name OS Version Power Status Fresh Air Capable = = = = = = = = = = PowerEdge R720 I 3.0.00 localhost.localdomain ON No Watchdog Information: Recovery Action = None Present countdown value = 478 seconds Initial countdown value = 480 seconds Embedded NIC MAC Addresses: NIC.Integrated.1-3-1 Ethernet NIC.
2 3 6 7 8 9 153 155 157 166 16233 16246 16247 26851 root root root root root root root root root root root root root root 0 0 0 0 0 0 0 0 0 0 40916 3824 3828 0 SW SW SW SW< SW SW< SW SW SW< SW S S R SW [kthreadd] [ksoftirqd/0] [watchdog/0] [khelper] [kdevtmpfs] [netns] [sync_supers] [bdi-default] [kblockd] [khubd] racadm racdump sh -c /bin/ps /bin/ps [kworker/u:3] =============================================================================== RAC Firmware Build Log =====================================
racresetcfg Description Deletes your current iDRAC configuration and resets iDRAC to the factory default settings based on the options provided. If you run racresetcfg from a network client (for example, a supported web browser, Telnet or SSH, or Remote RACADM), use the default IP address which is 192.168.0.120. The racresetcfg subcommand does not reset the cfgDNSRacName object. To run this subcommand, you must have the Configure iDRAC privilege and Configure User privilege.
Synopsis Input • racadm remoteimage -d • racadm remoteimage -s • racadm remoteimage -c [-u -p -l ] • • • • • • -c — Connect the image. -d — Disconnect image. -u — Username to access shared folder. -p — Password to access shared folder. -l — Image location on the network share; use single quotation marks around the location. -s — Display current status. NOTE: Use a forward slash (/) when providing the image location. If backward slash (\) is used, override the backw
rollback Description Allows you to roll back the firmware to an earlier version. Synopsis racadm rollback [--reboot] NOTE: To get the list of available rollback versions and FQDDs, run the racadm swinventory command. Input • • : Specify the FQDD of the device for which the rollback is required. --reboot: Performs a graceful system reboot after the BIOS firmware rollback. Example • To perform BIOS firmware rollback: racadm rollback iDRAC.Embedded.
Input — Specifies the power management operation to perform. The options are: • • • • • • • • hardreset — Performs a force reset (reboot) operation on the managed system. powercycle — Performs a power-cycle operation on the managed system. This action is similar to pressing the power button on the system’s front panel to turn off and then turn on the system. powerdown — Powers down the managed system. powerup — Powers up the managed system.
set Description Modifies the value of configuration objects on a component. The Set sub-command has two forms: • • The modification of a single object to a new value specified in the command line. The modification of multiple objects to new values using a configuration file. It supports multi-object value import from two configuration file formats.
Synopsis Single-object Set • racadm set . • racadm get .. • racadm get ..[]. • racadm get ....
Input • Examples for FQDDs: • • • • • • • • • • System.Power • System.Power.Supply • System.Location • LifecycleController.LCAttributes • System.LCD • iDRAC.Serial — Specifies the group containing the object that must be written. — Specifies the object name of the value that must be written. — This option is specified where FQDD Aliases or Groups must be indexed. -f — Enables set to configure the device from a specified file.
Example Single-object Set of real-time objects • Configure LCD String. $ racadm set system.lcd.LCDUserString test • • Configure iDRAC name. racadm set iDRAC.Info.Name idrac-server100 Single-object Set of staged objects • Configure several BIOS settings, create a job to initiate application of new values, reboot the system, then wait for the job to complete. racadm racadm racadm racadm • • set BIOS.SysProfileSettings.ProcTurboMode Disabled set BIOS.ProcSettings.ProcVirtualization Enabled set BIOS.
setled Description Sets the state (blinking or not blinking) of the LED on the specified module. To run this subcommand, you must have the Configure iDRAC permission. Synopsis Input racadm setled -l • -l — Specifies the LED state. The values are: • • Example • 0 — No Blinking 1 — Blinking From iDRAC stop LED from blinking. racadm setled -l 0 RAC0908: System ID LED blink off. • From iDRAC start LED to blink. racadm setled -l 1 RAC0907: System ID LED blink on.
Example • To Configure static IPv4 address for iDRAC NIC racadm setniccfg -s 192.168.0 255.255.255.0 192.168.0 Static IP configuration enabled and modified successfully • Configure DHCP mode for iDRAC IPv4 racadm setniccfg -d DHCP is now ENABLED • Configure DHCP mode for iDRAC IPv6 racadm setniccfg -d6 DHCP6 is now ENABLED sshpkauth Description Enables you to upload and manage up to 4 different SSH public keys for each user. You can upload a key file or key text, view keys, or delete keys.
• Get all keys for User 2 on iDRAC. $ racadm sshpkauth -v -i 2 -k all ********************* User ID 2 ****************** Key ID 1: ssh-rsa AAAAB3NzaC1yc2EAAAABIwAAAIEAzzy+k2npnKqVEXGXIzo0sbR6JgA5YNbWs3ekoxXV fe3yJVpVc/5zrrr7XrwKbJAJTqSw8Dg3iR4n3vUaP+lPHmUv5Mn55Ea6LHUslAXFqXmOdlThd wilU2VLw/iRH1ZymUFnut8ggbPQgqV2L8bsUaMqb5PooIIvV6hy4isCNJU= 1024-bit RSA, converted from OpenSSH by xx_xx@xx.
Input • -t — Specifies the type of certificate to upload. The type of certificate must be: • • • • • • 1 — server certificate 2 — Active Directory • 3 — Public Key Cryptography Standards (PKCS) format • 4 — Client Trust certificate for SSL format • 5 — Factory Identity Certificate format -f — Specifies the source filename in the local file system of the certificate uploaded. -k — Specifies optional source filename for private key when using type 6.
Serial Number 01 Subject Information: Country Code (CC) US State (S) Texas Locality (L) Round Rock Organization (O) Dell Inc. Organizational Unit (OU) Remote Access Group Common Name (CN) iDRAC Default certificate Issuer Information: Country Code (CC) US State (S) Texas Locality (L) Round Rock Organization (O) Dell Inc.
racadm sslcertview -t 1 -A 00 US Texas Round Rock Dell Inc. Remote Access Group iDRAC default certificate US Texas Round Rock Dell Inc. Remote Access Group iDRAC default certificate May 15 23:54:19 2017 GMT May 12 23:54:19 2027 GMT sslcertdelete Description Command to delete a custom signing certificate from iDRAC. To run this subcommand, you must have the Server Control privilege. Synopsis racadm sslcertdelete -t Input -t — Specifies the type of certificate to delete.
sslcsrgen Description Generates and downloads a certificate signing request (CSR) file to the client’s local file system. The CSR can be used for creating a custom SSL certificate that can be used for SSL transactions on iDRAC. To run this subcommand, you must have the Configure iDRAC privilege.
Example • Display current status of CSR operation: racadm sslcsrgen -s • Generate and download a CSR to local file system using remote RACADM racadm -r 192.168.0.120 -u -p sslcsrgen -g -f csrtest.txt • Generate and download a CSR to local file system using local RACADM racadm sslcsrgen -g -f c:\csr\csrtest.
Input Example N/A racadm sslresetcfg Certificate generated successfully and webserver restarted. storage Description Allows you to run the commands to control storage arrays. To run this subcommand for configuring the storage properties, you must have the server control permission.
Synopsis Inventory • To view the help details for get command, run the following command: racadm storage help get • To generate and view information about the inventory of storage root node, run the following command: racadm storage get status • To generate and view information about the inventory of controllers, run the following command: racadm storage get controllers -o racadm storage get controllers -o -p • To get the list of controllers, run the following com
Input • • • • • • • -o — Specifies the optimized version. -p — Specifies the property name. --refkey — Specifies the controller or enclosure FQDDs. -name — Specifies the new name for the virtual disk. -size — Specifies the new size for the virtual disk. It should be more than the current size. • b— Specifies the size in bytes • k— Specifies the size in kilobytes • m— Specifies the size in megabytes • g— Specifies the size in gigabytes • t— Specifies the size in terabytes -rl — Sets the storage level.
Example Inventory • To view the help details for get command, run the following command: racadm>>storage help get racadm storage help get Storage monitoring and inventory of hardware RAID connected to the system.
• To rename, expansion and raid level migration of the virtual disks. To rebuild, cancel rebuild and cancel the back-ground initialization.
SlotType MaxCapableSpeed LearnMode T10PICapability SupportRAID10UnevenSpans SupportEnhancedAutoForeignImport EnhancedAutoImportForeignConfig SupportControllerBootMode ControllerBootMode RealtimeConfigurationCapability RaidMode CurrentControllerMode = = = = = = = = = = = = Unknown 12.
The following command displays the output for Stash support and full controller objects along with their keys: racadm storage get controllers -o RAID.Modular.
PreservedCache CacheMemorySize PersistHotspare SpindownUnconfiguredDrives SpindownHotspare Timeintervalforspindown SecurityStatus EncryptionMode SasAddress PciDeviceId PciSubdeviceId PciVendorId PciSubvendorId PciBus PciDevice PciFunction BusWidth SlotLength SlotType MaxCapableSpeed LearnMode T10PICapability SupportRAID10UnevenSpans SupportEnhancedAutoForeignImport EnhancedAutoImportForeignConfig SupportControllerBootMode RealtimeConfigurationCapability RaidMode CurrentControllerMode • = = = = = = = = = =
The following command is an optimized and filtered version: racadm storage get vdisks -o -p DeviceDescription,OperationalState Disk.Virtual.0:RAID.Integrated.1-1 DeviceDescription = Virtual Disk 0 on Integrated raid Controller 1 OperationalState = Not applicable • To generate and view information about the inventory of virtual disks, run the following command: racadm storage get vdisks -o Disk.Virtual.2:RAID.Integrated.
FirmwareVersion 0.23 SasAddress 0x500056B31234ABFD SlotCount 24 The following command displays all enclosure keys connected to the connectors: racadm storage get enclosures --refkey RAID.Integrated.1-1 Enclosure.Internal.0-1:RAID.Integrated.1-1 The following command is an optimized and filtered version: racadm storage get enclosures --refkey RAID.Integrated.1-1 -o -p Name Enclosure.Internal.0-1:RAID.Integrated.
The following command displays all physical disk drive keys connected to the enclosures: racadm storage get pdisks --refkey RAID.Integrated.1-1 Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1 The following command is an optimized version and displays all disk objects for the enclosure FQDD: racadm storage get pdisks --refkey Enclosure.Internal.0-1:RAID.Integrated.1-1 -o racadm storage get pdisks -o Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.
The following command returns all the EMM keys connected to the enclosures: racadm storage get emms -refkey The following command is an optimized version and displays all the EMM objects for the enclosure FQDD: racadm storage get emms --refkey -o The following command is an optimized and filtered version: racadm storage get emms --refkey -o -p
Status = Ok DeviceDescription = PCIe Solid-State Drive in Slot 8 in Bay 1 Name = Physical Device 8 State = Ready Size = 745.21 GB BusProtocol = PCIe MediaType = SSD Model = SAMSUNG MZWEI800HAGM 000D3 ProductId = a820 SerialNumber = S1J1NYAD90019 DeviceProtocol = NVMe1.0 Manufacturer = SAMSUNG PCIeNegotiatedLinkWidth = x4 PCIeCapableLinkWidth = x4 MaxCapableSpeed = 8 GT/s NegotiatedSpeed = 8 GT/s FormFactor = 2.
SATA Drives - Use Enabled by Default -name : The name to give the VD -size : The size of the VD b : Specify the size in bytes k : Specify the size in kilobytes m : Specify the size in megabytes g : Specify the size in gigabytes t : Specify the size in terabytes -sc : Spandepth: Number of spans in a virtual disk Note: - This option is mandatory for hybrid raid level like RAID 10, RAID50 and RAID60. - The default value is one for basic RAID levels.
• The following command assigns or unassigns a global or dedicated Hot spare: racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -assign no racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -assign yes -type ghs racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -assign yes -type dhs -vdkey:Disk.Virtual.0:RAID.Integrated.
supportassist Description Allows to perform support assist operations such as: • • • • • • • • 130 collect : Collects the SupportAssist data and exports to local share, or remote share, or Dell site depending on the parameters given in the command. You can specify the type of the logs to be included in the collect command. To run this command user need to accept the End User License Agreement (EULA). register : Collects and uploads automatically using the userdata .
Synopsis • To perform support assist operation by specifying the type of the operation. racadm supportassist • To collect the data and keep it iDRAC. racadm supportassist collect –t • To collect the data and export to network share racadm supportassist collect –t u -p • --filter -l - To collect the data and upload to Dell support assist server.
Input • • • • • • • • • • • • • • • • • • • • • • • • • • • -t — Specifies the types of logs to be included in the export data. • -sysinfo — System information • -osAppAll— OS and Application data • -ttylog— TTY log information • -Debug— Debug and core files information -l — Specifies the network share location. -u — Specifies the username of the remote share. -p — Specifies the password of the remote share. -f — Specifies the target file name of the exported data.
• To collect the data and export to a remote share as well as to the Dell support assist server. racadm supportassist collect -t Debug -l //192.168.10.24/share -u myuser -p mypass -upload • To export the last collected SupportAssist data, to a CIFS share racadm supportassist exportlastcollection -l //192.168.10.24/share -u myuser -p mypass • To export the collected SupportAssist data to a CIFS or NFS share. The default share details must be updated for this command to work.
Input racadm swinventory Output racadm swinventory -------------------------SOFTWARE INVENTORY-----------------------ComponentType = FIRMWARE ElementName = Power Supply.Slot.1 FQDD = PSU.Slot.1 InstallationDate = 2017-02-02T23:58:55Z Current Version = 00.20.28 ------------------------------------------------------------------ComponentType = FIRMWARE ElementName = Integrated Dell Remote Access Controller FQDD = iDRAC.Embedded.1-1 InstallationDate = NA Rollback Version = 3.00.00.
Examples • To provide switch port details of all iDRAC and server network port racadm switchconnection view • To provide switch port details of requested FQDD NIC.Integrated.1-1-1:BRCM racadm switchconnection view NIC.Integrated.1-1-1:BRCM • To refresh switch port details of all ports in the server racadm switchconnection refresh systemconfig Description Enables you to perform the following: • • • • Backup and restore for iDRAC and entire system configuration.
Synopsis • racadm systemconfig backup -f [-n passphrase] [-l -u -p ] [--vFlash] • racadm systemconfig restore -f [-n passphrase ] [-nopreserve] [-l -u -p ] [--vFlash] • To create an AutoBackup Schedule.
Input • -n — Specifies a pass phrase used to encrypt or decrypt the configuration data. The pass phrase must have 8 to 32 characters, and one upper and lower case character. NOTE: This pass phrase is optional. • • -l — Specifies the network share location, can be either CIFS, NFS, HTTP, or HTTPS. -f — Specifies the image location and the file name.
Example • Back up system to CIFS share and encrypt the data. racadm systemconfig backup -f image.img -l //192.168.0/share -u admin -p xxx -n Encryptp@sswd123 • Back up system to NFS share and encrypt the data. racadm systemconfig backup -f image.img -l 192.168.0 :/share -u admin -p xxx -n Encryptp@sswd123 • Back up system to vFlash SD. racadm systemconfig backup --vFlash • Restore system from vFlash SD and clear the VD configurations.
systemerase Description Allows you to erase the components to remove the server from use. Synopsis • To erase a specific component. racadm systemerase • To erase multiple components. racadm systemerase ,, Input • — the valid types of components are: • • • • • • • • • • Examples bios— To reset the BIOS to default. diag— To erase embedded diagnostics. drvpack— To erase embedded OS driver pack. idrac— To reset the iDRAC to default.
Synopsis • To view the FQDD's of system performance monitoring sensors racadm systemperfstatistics view • To list the usage statistics of a specific sensor racadm systemperfstatistics • To reset the utilization peaks of system performance monitoring sensors racadm systemperfstatistics PeakReset • To run the peakreset operation you must have configure iDRAC privilege.
Synopsis • To perform the technical support report operation by specifying the type of operation. racadm techsupreport • To collect the report data. racadm techsupreport collect [-t ] • To export the collected report data. racadm techsupreport export -l -u p • To get the timestamp of the last operating system application data collection.
Examples • To collect the system information data. racadm techsupreport collect —t • To collect the system information and TTYLog data. racadm techsupreport collect -t SysInfo,TTYLog • To collect the operating system application data. racadm techsupreport collect -t OSAppAll • To export the collected Tech Support Report, to a CIFS share. racadm techsupreport export -l //192.168.0/share -u myuser -p xxx • To export the collected Tech Support Report, to an NFS share.
testtrap Description Tests the RAC’s SNMP trap alerting feature by sending a test trap from iDRAC to a specified destination trap listener on the network. To run this subcommand, you must have the Test Alert permission. NOTE: Synopsis • Before you run the testtrap subcommand, make sure that the specified index in the RACADM iDRAC.SNMP.Alert group is configured properly. • The indices of testtrap subcommand is co-related to the indices of iDRAC.SNMP.Alert group.
Example • Test a trap with index as 1. racadm testalert -i 1 Test trap sent successfully. • Test a trap that has not been configured yet. racadm testalert -i 2 ERROR: Trap at specified index is not currently enabled. traceroute Description Traces network path of the routers as the packets traverse from the system to a destination IPv4 address. To run this subcommand, you must have the Execute Diagnostic Commands permission.
update Table 9. Details of update subcommand Description Allows you to update the firmware of devices on the server. The supported firmware image file types are: • • • • .exe — Windows-based Dell Update Package (DUP) .d9 .pm .sc The supported catalog files are: • • .xml xml.gzip NOTE: Updating the platforms from the repository is not supported for IPv6. NOTE: Depending on the network traffic, the HTTP packet transfer may fail if you perform update operation from a remote RACADM through a local share.
Input For single file or DUP update: • • • • • -f: — Update filename (Windows DUP, .d7, .d9,.pm, .sc) only. -u: < username for CIFS share> — Specifies username of the remote share that stores the update file. Specify username in a domain as domain/username. -p: — Specifies network share location that stores the update file.
Output Firmware update job for is initiated. This firmware update job may take several minutes to complete depending on the component or firmware being updated. To view the progress of the job, run the racadm jobqueue view command. For repository update command, the output is: Update from repository operation has been initiated. Check the progress of the operation using "racadm jobqueue view -i JID_809364633532" command.
Example For single file or DUP updates: • Upload the update file from a remote CIFS share: racadm update -f -u admin -p mypass -l //1.2.3.4/share • Upload the update file from a remote CIFS share and under a user domain "dom": racadm update -f -u dom/admin -p mypass -l //1.2.3.4/share • Upload the update file from a remote NFS share: racadm update -f -l 1.2.3.
usercertupload Description Uploads a user certificate or a user CA certificate from the client to iDRAC. To run this subcommand, you must have the Configure iDRAC permission. Synopsis Input racadm usercertupload -t [-f ] -i • -t — Specifies the type of certificate to upload, either the CA certificate or server certificate. • • 1=user certificate • 2=user CA certificate -f — Specifies the filename of the certificate that must be uploaded.
vflashsd Description Allows you to initialize or get the status of the vFlash SD card. The initialize operation removes all the existing partitions and resets the card. The status operation displays the status of the last operation performed on the card. To run this subcommand, you must have the Access Virtual Media privilege. NOTE: After you restart the iDRAC, the status of the previous initialize operation is erased.
Input • • • • • -o — Label that is displayed when the partition is mounted on the operating system. This option must be a string of up to six alphanumeric characters. VFLASH is the only accepted volume label for non-Dell SD card. -e — Emulation type must be either floppy, CD, DVD, or HDD. -s — Partition size in MB. -f — Format type for the partition based on the type of the file system. Valid options are raw, ext2, ext3, fat16, and fat32.
vmdisconnect Description Allows you to end another Virtual Media session. After the session ends, the web-based interface reflects the correct connection status. Enables an iDRAC user to disconnect all active Virtual Media sessions. The active Virtual Media sessions are displayed on iDRAC web-based interface or by running the RACADM subcommands remoteimage or getssninfo. To run this subcommand, you must have the Access Virtual Media permission.
3 iDRAC Property Database Group and Object Descriptions The iDRAC property database contains the configuration information for iDRAC. Associated object is organizing data, and object group is organizing object. The IDs for the groups and objects that the property database supports are listed in this section for iDRAC Enterprise on Blade Servers and iDRAC Enterprise or Express on Rack and Tower Servers. To configure iDRAC, use the group and object IDs with the RACADM subcommands.
• • • • • cfgSensorRedundancy cfgVFlashSD cfgVFlashPartition cfgLogging cfgRacSecurity Displayable Characters Displayable characters include the following set: abcdefghijklmnopqrstuvwxwz ABCDEFGHIJKLMNOPQRSTUVWXYZ 0123456789~`!@#$%^&*()_+-={}[]|\:";'<>,.?/ The following table provides an overview of the object groups applicable for iDRAC Enterprise on Blade Servers.
Legal Values A string of up to 63 ASCII characters. Default The current version number. idRacBuildInfo (Read Only) Description String containing the current RAC firmware build version. Legal Values A string of up to 16 ASCII characters. Default The current iDRAC firmware build version. idRacName (Read Only) Description A user-assigned name to identify this controller. Legal Values A string of up to 15 ASCII characters.
cfgNicStaticIpAddress (Read or Write) Description Returns or sets the current IPv4 address. NOTE: Only set the current IPv4 address if cfgNicUseDhcp is set to 0(false). Legal Values Any Valid IPv4 address Default 192.168.0 cfgNicStaticUseDhcp (Read or Write) Description Specifies whether DHCP is used to configure the IPv4 network. Legal Values • • Default 0 — Do not use DHCP 0 — IP Address, subnet mask and gateway are configured on the device.
cfgDNSStaticServer1 (Read or Write) Description Specifies the IP address for DNS server 1. NOTE: This property is only valid if cfgDNSServersFromDHCP is set to 0 (FALSE). Legal Values • • Default 0 — Do not use DHCP 0 — IP Address, subnet mask and gateway are configured on the device. 1 — IP Address, subnet mask and gateway are assigned from the DHCP server. NOTE: If this object is modified, then the object cfgNicUseDhcp is also modified.
cfgRhostsFwUpdateTftpEnable (Read or Write) Description Enables or disables firmware update from a network TFTP server. NOTE: This object is read-only for iDRAC Modular servers. Legal Values • • Default 1 1 (TRUE) 0 (FALSE) cfgRhostsFwUpdateIpAddr (Read or Write) Description Specifies the network TFTP server IPv4 or IPv6 address that is used for TFTP firmware update operations. Legal Values A string representing a valid IPv4 or IPv6 address. For example, 192.168.0.61 Default For IPv4, it is 0.0.
cfgRhostsSyslogPort (Read or Write) Description Remote syslog port number to use for writing the RAC and SEL logs to a remote syslog server. Legal Values 10–65535 Default 514 cfgRhostsSyslogServer1 (Read or Write) Description To store the RAC and SEL logs specify the first of three possible remote syslog servers. This property is only valid if cfgRhostsSyslogEnable is set to 1 (enabled). Legal Values String from 0 to 63 characters.
cfgUserAdminIpmiLanPrivilege (Read or Write) Description The maximum privilege on the IPMI LAN channel. Legal Values • • • • 2(User) 3(Operator) 4(Administrator) 15(No access) Default • • 4(User 2) 15(All others) cfgUserAdminIpmiSerialPrivilege (Read or Write) Description The maximum privilege on the IPMI LAN channel. This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers.
Clear Logs 0x00000008 Execute Server Control Commands 0x00000010 Access Virtual Console 0x00000020 Access Virtual Media 0x00000040 Test Alerts 0x00000080 Execute Debug Commands 0x00000100 Examples The following table provides sample privilege bit masks for users with one or more privileges. User Privileges Privilege Bit Mask The user is not allowed to access iDRAC 0x00000000 The user may only log in to iDRAC and view iDRAC and server configuration information.
cfgUserAdminPassword (Write Only) Description The password for this user. User passwords are encrypted and cannot be seen or displayed after the property is written. Legal Values A string of up to 20 ASCII characters. Default ******** cfgUserAdminEnable (Read or Write) Description Enables or disables an individual user. NOTE: You can enable a user for a given index, only if you set the password for the same user.
cfgEmailAlertIndex (Read Only) Description The unique index of an alert instance. Legal Values 1–4 Default cfgEmailAlertCustomMsg (Read or Write) Description Specifies a custom message that forms the subject of the alert. Legal Values A string of up to 32 characters Default cfgEmailAlertEmailName (Read Only) Description Specifies name or other identifier associated with the destination email address.
cfgSsnMgtConsRedirMaxSessions (Read or Write) Description Specifies the maximum number of Virtual Console sessions allowed on iDRAC. Legal Values 1–4 Default 4 cfgSsnMgtWebserverTimeout (Read or Write) Description Defines the web server time-out. This property sets the amount of time (in seconds) that a connection is allowed to remain idle (there is no user input). The session is canceled if the time limit exceeds this property. Changes to this setting do not affect the current session.
Legal Values • • 0 (No timeout) 60–10800 NOTE: If 0 (no timeout is specified), the network connection does not send alive packets to probe the client. Otherwise, keep alive packets are sent to guarantee that the client is responding. Default • • For iDRAC on Rack and Tower Servers: 300 For iDRAC Enterprise on Blade Servers: 1800 cfgSerial This group contains configuration parameters for the serial configuration. One instance of the group is allowed.
Default: \ cfgSerialConsoleIdleTimeout (Read or Write) Description The maximum number of seconds to wait before an idle serial session is disconnected. Legal Values • • Default 300 0 = No timeout 60–1920 cfgSerialConsoleNoAuth (Read or Write) Description Enables or disables the serial console login authentication.
Legal Values • • Default 1 1 (TRUE) 0 (FALSE) Example racadm getconfig -g cfgSerial cfgSerialBaudRate=115200 cfgSerialConsoleEnable=1 cfgSerialConsoleQuitKey=^\ cfgSerialConsoleIdleTimeout=1800 cfgSerialConsoleNoAuth=0 cfgSerialConsoleCommand= cfgSerialConsoleColumns=0 cfgSerialHistorySize=8192 cfgSerialTelnetEnable=0 cfgSerialSshEnable=1 cfgSerialTelnetEnable (Read or Write) Description Enables or disables the Telnet console interface.
cfgOobSnmpAgentEnable (Read or Write) Description Enables or disables the SNMP agent in iDRAC. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgRacTuning This group is used to configure various configuration properties, such as valid ports and security port restrictions. Use this object with the config or getconfig subcommands. The following sections provide information about the objects in the cfgRacTuning group.
cfgRacTuneHttpsPort (Read or Write) Description To use HTTPS network communication, specify the port number. Legal Values 10–65535 Default 443 cfgRacTuneIpRangeEnable (Read or Write) Description Enables or disables the IPv4 Address Range validation feature. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgRacTuneIpRangeAddr (Read or Write) Description Specifies the acceptable IPv4 address bit pattern in the positions of the "1"s in the range mask property (cfgRacTuneIpRangeMask).
cfgRacTuneConRedirEnable (Read or Write) Description Enables or disables Virtual Console. Legal Values • • Default 1 1 (TRUE) 0 (FALSE) cfgRacTuneConRedirEncryptEnable (Read or Write) Description Encrypts the video in a Virtual Console session. Legal Values • • Default 1 1 (TRUE) 0 (FALSE) cfgRacTuneAsrEnable (Read or Write) Description Enables or disables iDRAC last crash screen capture feature. This object property requires an iDRAC reset before it becomes active.
cfgRacTuneTimezoneOffset (Read Only) Description Specifies the time zone offset (in minutes) from Greenwich Mean Time (GMT) / Coordinated Universal Time (UTC) to use for the RAC Time.
Legal Values • • Default 1 1 (TRUE) 0 (FALSE) cfgRacTuneVirtualConsoleAuthorizeMultipleSessions (Read or Write) Description If a first user is already using the Virtual Console, the value of this object affects the privileges granted to the subsequent user’s shared request after the timeout of 30 seconds. This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. NOTE: To modify this property, you must have Configure iDRAC permission.
Legal Values A string of up to 255 characters. Default cfgRacVirtual This group contains parameters to configure the iDRAC Virtual Media feature. One instance of the group is allowed. The following sections provide information about the objects in the cfgRacVirtual. cfgVirMediaAttached (Read or Write) Description This object is used to attach virtual devices to the system via the USB bus.
cfgSDWriteProtect (Read Only) Description Displays if the physical write protect latch on the SD card is enabled or disabled. NOTE: This command is deprecated from 12G iDRAC 1.0 release onwards. The functionality of this command is covered by cfgVFlashSDWriteProtect. While execution of the cfgSDWriteProtect command is successful, use the cfgVFlashSDWriteProtect command. For more information, see cfgVFlashwriteProtect (Read Only).
cfgServerFirstBootDevice (Read or Write) Description Sets or displays the first boot device. You can also set a vFlash partition that is attached as a bootable device. For more information, see cfgVFlashPartitionOSVoLabel. NOTE: If RFS is configured as the next boot device, during restart, the system starts normally and not from RFS. NOTE: First attach, to configure vFlash as First Boot Device.
cfgADDomainController1 (Read or Write) Description To obtain user names, specify the LDAP server from which you want the iDRAC. Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name (FQDN). Default None cfgADDomainController2 (Read or Write) Description To obtain user names, specify the LDAP server from which you want the iDRAC. This object is applicable only to iDRAC.
Default 120 cfgADEnable (Read or Write) Description Enables or disables Active Directory user authentication on iDRAC. If this property is disabled, only local iDRAC authentication is used for user login. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgADType (Read or Write) Description To use the Active Directory, determine the schema type.
cfgADCertValidationEnable (Read or Write) Description Enables or disables Active Directory certificate validation as a part of the Active Directory configuration process. Legal Values • • Default 1 1 (TRUE) 0 (FALSE) cfgADDcSRVLookupEnable (Read or Write) Description Configures iDRAC to use pre‑configured domain controllers or to use DNS to find the domain controller.
Default 0 cfgADGcRootDomain (Read or Write) Description The names of the Active Directory root domain used for DNS look up, to locate Global Catalog servers. This object is applicable only to iDRAC. Legal Values String. Maximum length = 254 Default Null cfgLDAP This group allows you to configure settings related to the Lightweight Directory Access Protocol (LDAP). Use this object with the config or getconfig subcommands. The following sections provide information about the objects in the cfgLDAP.
Legal Values String maximum length = 254 Default Null cfgLDAPEnable (Read or Write) Description Enables or disables LDAP service. If this property is disabled, local iDRAC authentication is used for user logins. Legal Values • • Default 0 1 — Enable 0 — Disable cfgLDAPGroupAttribute (Read or Write) Description Specifies which LDAP attribute is used to check for group membership. It must be an attribute of the group class. If not specified then the member and unique member attributes are used.
Default (objectless=*) Searches for all objects in tree. cfgLDAPServer (Read or Write) Description Configures the address of the LDAP Server. IPv4 and IPv6 are supported. NOTE: You can specify multiple servers by separating each server with a comma. For example, example.com, sub1.example.com Legal Values String. Maximum length = 1024 Default Null cfgLDAPUserAttribute (Read or Write) Description To search for, specify the user attribute.
cfgLdapRoleGroupPrivilege (Read or Write) Description A bit–mask defining the privileges associated with this particular group. Legal Values 0x00000000 to 0x000001ff Default 0x000 Example racadm getconfig -g cfgLDAPRoleGroup -o cfgLDAPRoleGroupPrivilege -i 1 0x0 cfgStandardSchema This group contains parameters to configure the Active Directory standard schema settings. Use this object with the config or getconfig subcommands.
• Example racadm getconfig -g cfgStandardSchema -i 1 # cfgSSADRoleGroupIndex=1 cfgSSADRoleGroupName=blsys-1 cfgSSADRoleGroupDomain= cfgSSADRolGroupPrivilege=3081 The following table displays the bit masks for Role Group privileges: Role Group Privilege Bit Mask Login to iDRAC 0x00000001 Configure iDRAC 0x00000002 Configure Users 0x00000004 Clear Logs 0x00000008 Execute Server Control Commands 0x00000010 Access Virtual Console 0x00000020 Access Virtual Media 0x00000040 Test Alerts 0x0000008
Default 1 cfgIpmiSolBaudRate (Read or Write) Description Specifies baud rate for serial communication over LAN. Legal Values 9600, 19200, 57600, 115200 Default 115200 cfgIpmiSolMinPrivilege (Read or Write) Description Specifies the minimum privilege level required for SOL access.
Default 0 cfgIpmiLanPrivLimit (Read or Write) Description Specifies the maximum privilege level allowed for IPMI over LAN access. Legal Values • • • \Default 4 2(User) 3(Operator) 4(Administrator) cfgIpmiLanAlertEnable (Read or Write) Description Enables or disables global email alerting. This property overrides all individual email alerting enable or disable properties.
cfgIpmiPetIPv6AlertDestIpAddr Description Configures the IPv6 alert destination IP address for the trap. Legal Values IPv6 address Default cfgIpmiPetIPv6AlertEnable (Read or Write) Description Enables or disables the IPv6 alert destination for the trap. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgIpmiPef This group is used to configure the platform event filters available on the managed server.
Default 0 cfgIpmiPefEnable (Read or Write) Description Enables or disables a specific platform event filter. Legal Values • • Default 1 1(TRUE) 0(FALSE) cfgIpmiPet This group is used to configure platform event traps on the managed server. The following sections provide information about the objects in the cfgIpmiPet group. cfgIpmiPetIndex (Read Only) Description Unique identifier for the index corresponding to the trap.
cfgUserDomainIndex (Read Only) Description Represents a specific domain. Legal Values 1–40 Default The index value. cfguserdomainname (Read Only) Description Specifies the Active Directory user domain name. Legal Values A string of up to 254 ASCII characters Default cfgServerPower This group provides several power management features. The following sections provide information about the objects in the cfgServerPower group.
cfgServerPowerCapEnable (Read or Write) Description Enables or disables the user specified power budget threshold. This object is Read only for iDRAC Enterprise on Blade Servers. Legal Values • • Default 1 0 — Disables the user specified power budget threshold 1 — Enables the user specified power budget threshold cfgServerMinPowerCapacity (Read Only) Description Represents the minimum server power capacity on a blade based on the current component inventory.
cfgServerPowerCapWatts (Read or Write) Description Represents the server power threshold in Watts. NOTE: This value is applicable only if the cfgServerPowerCapEnable is set to 1. Legal Values None Default Server power threshold in Watts. cfgServerPowerCapBtuhr (Read or Write) Description Represents the server power threshold in BTU/hr. NOTE: This value is applicable only if cfgServerPowerCapEnable is set to 1. Legal Values None Default Server power threshold in BTU/hr.
Default Average power value during the last week. cfgServerPowerLastHourMinPower (Read Only) Description Displays the minimum power value during the last hour. Legal Values Not applicable Default Minimum power value during the last hour. cfgServerPowerLastHourMinTime (Read Only) Description Displays the timestamp of minimum power value during the last minute.
cfgServerPowerLastDayMinPower (Read Only) Description Displays the minimum power value during the last day. Legal Values Not applicable Default Minimum power value during the last day. cfgServerPowerLastDayMinTime (Read Only) Description Displays the timestamp of minimum power value during the last day.
cfgServerPowerLastWeekMinPower (Read Only) Description Displays the minimum power value during the last week. Legal Values Not applicable Default Minimum power value during the last week. cfgServerPowerLastWeekMinTime (Read Only) Description Displays the timestamp of minimum power value during the last week. Legal Values A string of up to 32 characters.
cfgServerPowerInstHeadroom (Read Only) Description Displays the difference between the available power and the current power consumption. This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. Legal Values Not applicable Default Difference between the available power and the current power consumption. cfgServerPowerPeakHeadroom (Read Only) Description Displays the difference between the available power and the peak power consumption.
cfgServerCumulativePowerConsumption (Read Only) Description Displays the cumulative power consumption. Legal Values Not applicable Default Cumulative power consumption. cfgServerCumulativePowerConsumptionTimeStamp (Read Only) Description Displays the timestamp of the cumulative power consumption. Legal Values A string of up to 32 characters.
cfgServerPowerSupply This group contains information related to the power supplies. The cfgServerPowerSupply object group is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. NOTE: The getconfig subcommand always shows eight cfgServerPowerSupply indexes, even if two power supplies are installed in the system or the system supports a maximum of two PSUs.
Default 0 cfgServerPowerSupplyOnlineStatus (Read Only) Description Displays the status of the PSU. Legal Values • • • • Default 0 — Present 0 — Present 1 — Absent 2 — Failure 3 — Predictive failure cfgServerPowerSupplyType Description Displays whether the power supply is AC or DC. Legal Values A string of up to 32 characters. Default 0 cfgIPv6LanNetworking This group is used to configure the IPv6 over LAN networking capabilities. Use this object with the config or getconfig subcommands.
Default “ :: “ cfgIPv6AutoConfig (Read or Write) Description Enables or disables the IPv6 Auto Configuration option. NOTE: If this value is set to 0, the iDRAC disables auto configuration and statically assigns IPv6 addresses. If this value is set to 1, the iDRAC obtains address and route information using stateless auto configuration and DHCPv6. NOTE: The iDRAC uses its MAC address for its DUID (DUID-LL) when communicating with a DHCPv6 server.
Default : cfgIPv6Address4 (Read Only) Description The iDRAC IPv6 fourth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address5 (Read Only) Description The iDRAC IPv6 fifth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address6 (Read Only) Description The iDRAC IPv6 sixth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address7 (Read Only) Description The iDRAC IPv6 seventh address.
cfgIPv6Address10 (Read Only) Description The iDRAC IPv6 tenth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address11 (Read Only) Description The iDRAC IPv6 eleventh address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address12 (Read Only) Description The iDRAC IPv6 twelfth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address13 (Read Only) Description The iDRAC IPv6 thirteenth address.
cfgIPv6DNSServer1 (Read or Write) Description Specifies the IPv6 DNS server address. NOTE: This property is used only if cfgIPv6DNSServersFromDHCP6 is set to 0 (false). Legal Values A string representing a valid IPv6 entry. For example, 2001:DB8:1234:5678:9ABC:DE11:C00C:BEEF Default “ :: “ cfgIPv6DNSServersFromDHCP6 (Read or Write) Description Specifies whether cfgIPv6DNSServer1 and cfgIPv6DNSServer2 are static or DHCP IPv6 addresses.
Legal Values Any IPv6 address Default cfgIPv6StaticPrefixLength (Read or Write) Description The prefix length for static IPv6 address 1. Legal Values 0–128 Default 64 cfgIPv6StaticAutoConfig (Read/Write) Description Enables or disables the static IPv6 AutoConfig option. Legal Values • • Default 1 — Enabled 0 — Disabled 1 — Enabled NOTE: If this object is modified, then the object cfgIPv6Autoconfig is also modified.
cfgIPv6DNSServer2 (Read or Write) Description Specifies the IPv6 DNS server address. NOTE: This property is only valid if cfgIPv6DNSServersFromDHCP6 is set to 0 (false). Legal Values A string representing a valid IPv6 entry.
It is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. cfgIpmiSerialBaudRate (Read or Write) Description Specifies the baud rate for a serial connection over IPMI. Legal Values 9600, 19200, 57600, 115200 Default 57600 cfgIpmiSerialChanPrivLimit (Read or Write) Description Specifies the maximum privilege level allowed on the IPMI serial channel.
cfgIpmiSerialFlowControl (Read or Write) Description Specifies the flow control setting for the IPMI serial port. Legal Values • • Default 1 0 (None) 1 (CTS or RTS) cfgIpmiSerialHandshakeControl (Read or Write) Description Enables or disables the IPMI terminal mode handshake control. Legal Values • • Default 1 0(FALSE) 1 (TRUE) cfgIpmiSerialInputNewLineSequence (Read or Write) Description Specifies the input new line sequence specification for the IPMI serial interface.
cfgSmartCard This group specifies properties used to support access to iDRAC using a smart card. The following sections provide information about the objects in the cfgSmartCard group. cfgSmartCardLogonEnable (Read or Write) Description To iDRAC using a smart card, enable or disable with Remote RACADM support for access. NOTE: Enabling with remote RACADM is only applicable for iDRAC on Rack and Tower Servers.
Example racadm getconfig -g cfgNetTuning cfgNetTuningNicSpeed=100 cfgNetTuningNicFullDuplex=1 cfgNetTuningNicMtu=1500 cfgNetTuningNicAutoneg=1 cfgNetTuningNic100MB (Read or Write) Description Specifies the speed for iDRAC NIC. NOTE: To set this property: Legal Values • • • • iDRAC NIC selection must be set to Dedicated mode. • • iDRAC NIC Auto negotiation must be disabled. iDRAC IPv4 must be enabled. • • • iDRAC IPv4 DHCP must be enabled. iDRAC IPv6 must be enabled.
This group is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. cfgSensorRedundancyCapabilities (Read Only) Description Returns the redundancy capabilities in the form of a bitmask. This bitmask allows the user to know which values can be set for cfgSensorRedundancyPolicy. Legal Values A bit mask. More than 1 bit can be set at a time to indicate multiple redundancy support.
cfgVFlashSD This group is used to configure the properties for the Virtual Flash SD card. NOTE: If the vFlash card is present but is not enabled, the query for any property under this group displays: ERROR: vFlash is not enabled. To view the properties of this group, enable the vFlash using the command: racadm config -g cfgvFlashSD -o cfgvFlashSDEnable 1 The following sections provide information about the objects in the cfgVFlashSD group.
cfgVFlashSDAvailableSize (Read Only) Description Displays the available memory (in MB) on the vFlash SD card that can be used to create new partitions. Legal Values A string of up to 64 characters. Default If the card is not initialized, default is 0. If initialized, displays the unused memory on the card. cfgVFlashSDHealth (Read Only) Description Displays the current health status of the vFlash SD card.
Default None cfgVFlashPartitionEmulationType (Read or Write) Description View or modify the emulation type for the partition. Legal Values String: • • • Default HDD Floppy CD-DVD None cfgVFlashPartitionFlashOSVolLabel (Read Only) Description Displays the label for the partition that is visible to the operating system. Legal Values An alphanumeric string of up to six characters. Default None cfgVFlashPartitionFormatType (Read Only) Description Displays the format type of the partition.
Legal Values • • Default 0 — Detached 1 — Attached 0 — Detached cfgLogging This group contains parameters to enable or disable the OEM event log filtering. The following section provide information about the objects in the cfgLogging group: cfgLoggingSELOEMEventFilterEnable (Read or Write) Description Enables or disables the SEL Log filtering.
cfgRacSecCsrLocalityName (Read or Write) Description Specifies the CSR Locality (L). Legal Values A string of up to 128 characters. Default cfgRacSecCsrStateName (Read or Write) Description Specifies the CSR State Name (S). Legal Values A string of up to 128 characters. Default cfgRacSecCsrCountryCode (Read/Write) Description Specifies the CSR Country Code (CC). Legal Values A string of 2 alphabet country code.
4 Database Objects With Get and Set Commands This chapter provides the database groups and objects that must be used with the get or set subcommands. When using the objects, they must begin with FQDD or FQDD alias. The set operations for iDRAC, Lifecycle Controller, and system objects do not require server restart. However, the set operations for NIC and BIOS objects are staged to apply and commit the pending values.
4; 5Retries - 5;6Retries- 6; IndefiniteRetries, Default - NoRetry Required License -- RACADM Dependency -- None BootStrapType system. Usage AutoDetect Required License Dependency -- Specify the boot strap method used to boot to the operating -- AutoDetect - 0;BBS - 1; Int18h - 2; Int19h- 3; Default -- RACADM -- None HideSetupPrompt -- Specifies whether to display or hide the legacy Option ROM setup prompt during system Power On Self Test (POST).
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 216 System.Backplane System.Chassis System.ChassisControl System.ChassisInfo System.QuickSync System.LCD System.Location System.PCIESlotLFM System.Power System.Power.Supply System.ServerOS System.Storage System.ThermalSettings System.ThermalConfig LifecycleController.LCAttributes iDRAC.ActiveDirectory iDRAC.ADGroup iDRAC.AutoOSLock iDRAC.EmailAlert iDRAC.GroupManager iDRAC.GUI iDRAC.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • iDRAC.SSH iDRAC.SysLog iDRAC.Telnet iDRAC.Time iDRAC.Tuning iDRAC.Update iDRAC.USB iDRAC.UserDomain iDRAC.Users iDRAC.vflashpartition iDRAC.vflashsd iDRAC.VirtualConsole iDRAC.VirtualMedia iDRAC.VNCServer iDRAC.WebServer BIOS.BiosBootSettings BIOS.IntegratedDevices BIOS.EmbServerMgmt BIOS.MemSettings BIOS.MiscSettings BIOS.NetworkSettings BIOS.OneTimeBoot BIOS.ProcSettings BIOS.
System.Backplane The objects in this group manage the backplane. System.Backplane.BackplaneBusMode (Read Only) Description Indicates the backplane Serial General Purpose Input or Output (SGPIO) mode. Legal Values • • • Default Value 1 — I2C Write Privilege Configure iDRAC 0 — Unknown 1 — I2C 2 — SGPIO License Required iDRAC Express or iDRAC Enterprise Dependency None System.Chassis To control the chassis related events, use this group. System.Chassis.
System.ChassisControl.ChassisManagementMonitoring (Read or Write) Description Enables or disables the event forwarding from CMC. Legal Values • • Default value 1 — Enabled Write Privilege Server Control License Required Base Dependency ChassisMangamentAt server object. 0 — Disabled 1 — Enabled System.ChassisInfo The objects in this group are applicable only to modular chassis such as Dell PowerEdge M1000e. To obtain the chassis-specific information, use this group. System.ChassisInfo.
System.QuickSync The objects in this group manage the configuration and recovery of QuickSync settings. System.QuickSync.Access (Read or Write) Description Configures the accessibility using Quick Sync on the server. Legal Values • • • Default Value 2 — Read-write Write Privilege Server Control 0 — Disabled 1 — Read-only 2 — Read-write License Required iDRAC Express or iDRAC Enterprise Dependency To configure, the System.QuickSync.Presence property must indicate Present System.QuickSync.
Dependency None System.QuickSync.ReadAuthentication (Read or Write) Description Enable or disable whether credentials are required when reading via Quick Sync. Legal Values • • Default value 1 - Enabled Write Privilege Configure iDRAC 0 - Disabled 1 - Enabled License Required iDRAC Express Dependency The values for System.QuickSync.Presence property must indicate Present System.QuickSync.WiFi (Read or Write) Description Enables or disables local WiFi to the server through Quick Sync.
Default Value 32 — Service Tag Write Privilege Configure iDRAC and Configure User License Required iDRAC Express or iDRAC Enterprise Dependency None System.LCD.vConsoleIndication (Read or Write) Description Specifies the virtual console indication. Legal Values • • Default Value Enabled Write Privilege • • Enabled Disabled Configure iDRAC Configure User License Required iDRAC Express or iDRAC Enterprise Dependency None System.LCD.
Legal Values • • Default Value C Write Privilege Configure iDRAC C F License Required iDRAC Express or iDRAC Enterprise Dependency None System.LCD.QualifierWatt (Read or Write) Description Specifies the system Watt qualifier. Legal Values • • Default Value Watts Write Privilege Configure iDRAC Watts BTU per hour License Required iDRAC Express or iDRAC Enterprise Dependency None System.LCD.UserDefinedString (Read or Write) Description Indicates the LCD string set.
System.Location.DataCenter (Read or Write) Description Indicates name of the data center where the system is located. Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Location.DeviceSize (Read Only) Description Indicates server chassis size.
System.Location.RoomName (Read or Write) Description Room name where the system is located. Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Location.Chassis.Name (Read Only) Description Indicates the chassis name.
Write Privilege Not Applicable License Required RACADM Dependency None System. pcieSlotLFM. CardType (Read) Description Indicates the type of PCIe card installed. Legal Values Not Applicable Default value Not Applicable Write Privilege Not Applicable License Required RACADM Dependency None System. pcieSlotLFM. CustomLFM (Read or Write) Description Indicates the minimum airflow to be delivered the installed PCIe card.
System.pcieSlotLFM.Slot (Read) Description Indicates the PCIe slot number Legal Values Not Applicable Default value Not Applicable Write Privilege Not Applicable License Required RACADM Dependency None System. pcieSlotLFM.SlotState (Read) Description Indicates the PCIe slot physically exists Legal Values • • Default value 0—Not-Defined Write Privilege Not applicable License Required RACADM Dependency None 0—Not-Defined 1—Defined System. pcieSlotLFM.
License Required Not Applicable Dependency Not Applicable System.Power.ServerAllocation (Read Only) Description Indicates the power allocated to running blades. This value is displayed in both watts and BTU/h units. Legal Values 0–7928 Default Value Not Applicable Write Privilege Not Applicable License Required Not Applicable Dependency None System.Power.Avg.LastDay (Read Only) Description Indicates the average power value during the last day.
Dependency None System.Power.Cap.ActivePolicy.Btuhr (Read Only) Description Represents the active power in BTU/Hr a device is allowed to consume. Legal Values Values: 1–65535 Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Cap.ActivePolicy.
License Required iDRAC Express or iDRAC Enterprise Dependency Enable System.Power.Cap.Enable System.Power.Cap. Enable (Read or Write) Description Enables or disables user specified power budget threshold configuration. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Cap.
Legal Values Values: 0–100 Default Value Server power threshold in percentage. Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Enable System.Power.Cap.Enable System.Power.Redundancypolicy (Read or Write) Description Selects the redundancy policy. Legal Values • • • • 255 — N/A, for the systems that are not supported 0 — Not Redundant — In this mode, even if one PSU stops functioning, the server is automatically turned off.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.EnergyConsumption.Clear (Read or Write) Description Clears the cumulative power consumption timestamps. Legal Values 1 Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.EnergyConsumption.StarttimeStamp (Read Only) Description Displays the Timestamp of the cumulative power consumption.
System.Power.Hotspare.PrimaryPSU (Read or Write) Description Represents the primary PSU selection. NOTE: This object is supported only for iDRAC on Rack and Tower servers. Legal Values • • • • Default Value Not Applicable Write Privilege Configure iDRAC 1 — PSU1 2 — PSU2 5 — PSU1 and PSU3 10 — PSU2 and PSU4 License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.Amps (Read Only) Description Specifies the device Peak Power Consumption since this value was last cleared.
Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.LastDay (Read Only) Description Displays the maximum power value during the last day. Legal Values Values: 1–65535 Default Value Maximum power value during the last day. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.LastDay.
Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.LastWeek (Read Only) Description Displays the maximum power value during the last week. Legal Values Values: 1–65535 Default Value Maximum power value during the last week. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.LastWeek.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.PowerClear (Read or Write) Description Clears the Maximum Power Consumption timestamps. Legal Values 1 — Clear the Power Consumption Statistics Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Min.LastDay (Read Only) Description Displays the minimum power during the last day.
Default Value Minimum power value during the last hour. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Min.LastHour.Timestamp (Read Only) Description Indicates the timestamp of minimum power during the last hour. Legal Values String of up to 254 ASCII characters Default Value Timestamp of the minimum power value during the last hour.
Legal Values • • 0 — Disabled 1 — Enabled Default Value • • 0 — For platforms that do not support PCIe cards. 500 W — For platforms that support PCIe cards. Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.PFCEnable (Read or Write) Description Enables the power factor correction enable. NOTE: • • This object is supported only for iDRAC on Rack and Tower servers. This object is applicable only if System.Power.Cap.Enable is set to 1.
System.Power.RedundantState (Read Only) Description Retrieves the redundancy state for the chassis. NOTE: This object is not applicable for Rack and Tower server. Legal Values • • Default 0 — None Write Privilege Not Applicable 0 — None 1 — Full License Required Not Applicable Dependency Not Applicable System.Power.Supply This group provides information relating to the Power Supplies. This group is indexed from 1 to 4.
Legal Values Integer > 0 Default Value 0 Write Privilege Not Applicable License Required Not Applicable Dependency Not Applicable System.Power.Supply.[i].MaxOutputPower (Read Only) Description Displays the DC output rated power in Watts. Legal Values Integer > 0 Default Value 0 Write Privilege Not Applicable License Required Not Applicable Dependency Not Applicable System.Power.Supply.[i].Status (Read Only) Description Displays the status of the PSU.
System.Power.Supply.[i].LineStatus (Read Only) Description Specifies if this power supply is powered off or on. Legal Values Integer > 0 Default None Write Privilege Not Applicable License Required Not Applicable Dependency Not Applicable System.Power.Supply.[i].PMBusMonitoring (Read Only) Description Specifies if this PMBus is present or not. Legal Values Integer > 0 Default 0 Write Privilege Not Applicable License Required Not Applicable Dependency Not Applicable System.
Dependency None System.ServerOS.OSVersion (Read Only) Description Indicates the operating system version of the managed server. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.ServerOS.ServerPoweredOnTime (Read Only) Description Indicates the time (in seconds) from when the operating system is turned ON.
Legal Values String of 1 to 99 characters Default Value 10 Write Privilege Configure iDRAC License Required iDRAC RACADM Dependency None System.ThermalSettings This group provides information about the thermal settings of the server. To know more about the platforms supported for AirExhaustTemp and FanSpeedOffset settings, see the iDRAC User's Guide available at www.dell.com/esmmanuals. System.ThermalSettings.
Default Value 0 Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalSettings.FanSpeedOffset (Read or Write) Description Specifies the fan speed offset. NOTE: This attribute is platform dependent. Legal Values • • • Default value OFF 0 — Low fan speed 1 — High fan speed 255 — OFF License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalSettings.
System.ThermalSettings.FanSpeedHighOffsetVal (Read Only) Description Indicates the percentage range for the high fan offset speed. NOTE: This attribute is platform dependent. Legal Values Integral Values: 0 – 100 Default Value 0 License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalSettings.FanSpeedMaxOffsetVal (Read Only) Description Indicates the percentage range for low fan offset speed. NOTE: This attribute is platform dependent.
System.ThermalSettings.ThermalProfile (Read or Write) Description Sets the thermal base algorithm. NOTE: Restart the system to activate the power and thermal settings. Legal Values • • • Default Value Auto Write Privilege Configure iDRAC 0 — Default Thermal Profile Settings 1 — Maximum performance 2 — Minimum Power License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalSettings.
Legal Values Integral Values: 0-365 Default Value 30 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalConfig.FreshAirCompliantConfiguration (Read Only) Description Indicates whether or not the system is configured to be fresh air compliant. Legal Values • • • Default Value 1 — Yes 0 — Not Applicable 1 — Yes 2 — No License Required iDRAC Express or iDRAC Enterprise Dependency None LifecycleController.
Dependency None LifecycleController.LCAttributes.autoupdate (Read or Write) Description Enables or disables the automatic update scheduler. Legal Values • • Default Value 1 — Enabled Write Privilege Server Control 0 — Disabled 1 — Enabled License Required iDRAC Enterprise Dependency None LifecycleController.LCAttributes.BiosRTDRequested (Read or Write) Description Reset all the BIOS attributes to the default state.
LifecycleController.LCAttributes.DiscoveryFactoryDefault s (Read Only) Description Enables or disables the discovery factory defaults. Legal Values • • Default Value 0 — Off Write Privilege Not Applicable License Required iDRAC Enterprise Dependency None 0 — Off 1 — On LifecycleController.LCAttributes.IgnoreCertWarning(Read and Write) Description Specifies to ignore Certificate Warning when HTTPS specified.
LifecycleController.LCAttributes.LifecycleControllerState (Read or Write) Description Enables or disables lifecycle controller. Legal Values • • • Default Value 1 — Enabled Write Privilege Server Control 0 — Disabled 1 — Enabled 2 — Recovery (Read Only Value) License Required iDRAC Express or iDRAC Enterprise Dependency None LifecycleController.LCAttributes.ProvisioningServer (Read or Write) Description Specifies the Provisioning Server Address.
Legal Values 0 — Disabled 1 — Allow version upgrade only 2 — Match firmware of replaced part Default Value 2 — Match firmware of replaced part Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None LifecycleController.LCAttributes.SystemID (Read Only) Description Specifies the Dell System ID. Legal Values Not Applicable Default Value None Write Privilege Not Applicable License Required iDRAC Enterprise Dependency None LifecycleController.
LifecycleController.LCAttributes. UserProxyServer (Read and Write) Description Specifies the proxy server Legal Values string of 0 to 256 characters length Default value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None LifecycleController.LCAttributes.
iDRAC.ActiveDirectory To manage the configuration of the iDRAC Active Directory features, use the objects in this group. iDRAC.ActiveDirectory.AuthTimeout (Read or Write) Description To wait for ActiveDirectory authentication requests to complete before timing out, specify the time in seconds. Legal Values Integral values: 15–300 Default Value 120 Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.
iDRAC.ActiveDirectory.DCLookupDomainName (Read or Write) Description The configured search domain is used when DCLookupByUserDomain is disabled. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.
Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.DomainController3 (Read or Write) Description FQDN that stores the address of the active directory domain controller 3 Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.
iDRAC.ActiveDirectory.GCRootDomain (Read or Write) Description The names of the Active Directory root domain used for DNS look up. Legal Values String of up to 254 ASCII characters Write Privilege Not Applicable Write Privilege Configure iDRAC License Required None Dependency None iDRAC.ActiveDirectory.GlobalCatalog1 (Read or Write) Description Specifies the Global Catalog server from which you want the iDRAC to obtain user names.
iDRAC.ActiveDirectory.RacDomain (Read or Write) Description Active Directory Domain in which iDRAC resides. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.RacName (Read or Write) Description Name of iDRAC as recorded in the Active Directory forest.
Dependency Cannot be enabled unless SmartCard Logon Enable is disabled. iDRAC.ADGroup To manage the configuration of AD standard schema settings, use these objects in the group. This group is indexed from 1 to 5. iDRAC.ADGroup.Domain (Read or Write) Description Active Directory Domain in which the Role Group resides. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ADGroup.
iDRAC.AutoOSLock.AutoOSLockState (Read or Write) Description Enable or Disable OS Auto lock feature. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.EmailAlert The objects in this group configure email alerting capabilities. This group is indexed from 1 to 4. iDRAC.EmailAlert.Address (Read or Write) Description Specifies the destination email address for email alerts.
Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.GroupManager The objects in this group helps to add or delete the group from group manager. iDRAC.GroupManager.GlobalState (Read or Write) Description Enable / Disable Group Manager Global State Legal Values • • Default Value 0- Disabled Write Privilege Configure iDRAC 1- Enabled 0- Disabled License Required Group Manager Dependency None iDRAC.GroupManager.
iDRAC.GUI The objects in this group helps to set security policy banner string. iDRAC.GUI.SecurityPolicyMessage (Read or Write) Description To Get / Set Security Policy Banner String Legal Values A string of upto 1024 Unicode character bytes Default Value Not Applicable Write Privilege Configure iDRAC License Required None Dependency None iDRAC.Info To manage information about iDRAC being queried, use these objects in the group. iDRAC.Info.
Legal Values String of up to 15 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Info.Product (Read or Write) Description String identifying the Product. Legal Values String of up to 63 ASCII characters Default Value Integrated Dell Remote Access Controller Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Info.
Dependency None iDRAC.IOIDOpt The objects in this group manage the IOIDOpt attributes. iDRAC.IOIDOptEnable (Read or Write) Description Enables or disables Identity Optimization (IO). Legal Values • • Default values 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IOIDOpt.InitiatorPersistencePolicy (Read or Write) Description Sets the virtual address management .
Default Value ACPowerLoss, PowerGoodReset, WarmReset Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency To configure, the iDRAC.IOIDOpt.Enable property must indicate Enabled. iDRAC.IOIDOpt.VirtualAddressPersistencePolicyAuxPwrd (Read or Write) Description Applied for the Aux powered devices, which persist the virtual address on cold and warm reset.
iDRAC.IPBlocking.RangeAddr (Read or Write) Description Specifies the acceptable IPv4 address bit pattern in positions determined by the 1s in the range mask. Legal Values Valid IPv4 Address Default Value 192.168.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPBlocking.RangeEnable (Read or Write) Description Enables or disables the IPv4 Address Range validation feature of iDRAC.
Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMILan.CommunityName (Read or Write) Description Specifies the SNMP community name for traps. Legal Values String of up to 18 ASCII characters Default Value Public Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMILan.Enable (Read or Write) Description Enables or disables the IPMI over LAN interface.
iDRAC.IPMILan.PrivLimit (Read or Write) Description Specifies the maximum privilege level for IPMI over LAN access. Legal Values • • • Default Value 4 — Administrator Write Privilege Configure iDRAC 2 — User 3 — Operator 4 — Administrator License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial To configure the IPMI serial interface, use this objects in this group. NOTE: This is supported only for rack and tower systems. iDRAC.IPMISerial.
iDRAC.IPMISerial.ConnectionMode (Read or Write) Description Determines the IPMI defined mode of the serial port. Legal Values • • Default Value 1 — Basic Write Privilege Configure iDRAC 1 — Basic 0 — Terminal License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.DeleteControl (Read or Write) Description Enables or disables delete control on the IPMI serial interface.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.HandshakeControl (Read or Write) Description Enables or disables the IPMI terminal mode handshake control. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.
iDRAC.IPMISerial.NewLineSeq (Read or Write) Description Specifies the new line sequence for the IPMI serial interface. Legal Values • • • • • • Default Value 1 — CR-LF Write Privilege Configure iDRAC 0 — None 1 — CR-LF 2 — Null 3 — CR 4 — LF-CR 5— LF License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISOL Use the objects in this group to configure the SOL capabilities of the system. iDRAC.IPMISOL.
iDRAC.IPMISOL.Enable (Read or Write) Description Enables or disables SOL. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISOL.MinPrivilege (Read or Write) Description Specifies the minimum privilege level required for serial access.
Legal Values Valid IPv4 Address ` Default Value 192.168.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv4.DHCPEnable is disabled. iDRAC.IPv4.DHCPEnable (Read or Write) Description Specifies if DHCP is used to assign the iDRAC IPv4 address.
iDRAC.IPv4.DNSFromDHCP (Read or Write) Description Specifies if the DNS server IPv4 addresses must be assigned from the DHCP server on the network. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv4.Enable (Read or Write) Description Enables or disables the iDRAC IPv4 stack.
License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv4.DHCPEnable is disabled. iDRAC.IPv4Static Use the objects in this group to manage the IPv4 Static configuration properties of iDRAC. iDRAC.IPv4Static.Address (Read or Write) Description iDRAC static IPv4 address. This address can be configured even when DHCP is enabled. Legal Values Valid IPv4 Address Default Value 192.168.
iDRAC.IPv4Static.DNSFromDHCP (Read or Write) Description Specifies if the DNS server IPv4 addresses should be assigned from the DHCP server on the network. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.IPv4Static.Gateway (Read or Write) Description iDRAC static IPv4 gateway. This address can be configured even when DHCP is enabled.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address 2 (Read or Write) Description iDRAC IPv6 second address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address 3 (Read or Write) Description iDRAC IPv6 third address.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address 6 (Read or Write) Description iDRAC IPv6 sixth address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address 7 (Read or Write) Description iDRAC IPv6 seventh address.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address10 (Read or Write) Description iDRAC IPv6 tenth address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address11 (Read or Write) Description iDRAC IPv6 eleventh address.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address14 (Read or Write) Description iDRAC IPv6 fourteenth address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address15 (Read or Write) Description iDRAC IPv6 fifteenth address.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv6.DNSFromDHCP6 is disabled. iDRAC.IPv6.DNS2 (Read or Write) Description IPv6 DNS Server 2 Address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv6.DNSFromDHCP6 is disabled. iDRAC.IPv6.
Legal Values Valid IPv6 gateway Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv6.AutoConfig is disabled. iDRAC.IPv6.LinkLocalAddress (Read or Write) Description iDRAC IPv6 Link Local Address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.
iDRAC.IPv6Static.DNS1 (Read or Write) Description Statically configurable DNS Server 1. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6Static.DNS2 (Read or Write) Description Statically configurable DNS Server 2. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6Static.
iDRAC.IPv6Static.PrefixLength (Read or Write) Description Prefix length for the iDRAC IPv6 Address. Legal Values Integral values: 1–128 Default Value 64 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6URL Use the objects in this group to manage the IPv6 static configuration properties of iDRAC. iDRAC.IPv6URL.
Legal Values String of up to 255 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LDAP.BindPassword (Write Only) Description A bind password to use along with the bindDN. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LDAP.
iDRAC.LDAP.GroupAttribute (Read or Write) Description Specifies which LDAP attribute is used to check for group membership. Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LDAP.GroupAttributeIsDN (Read or Write) Description Specifies whether the user domain name must be used from the LDAP server or from the user that provides login.
Dependency None iDRAC.LDAP.Server (Read or Write) Description Configures the address of the LDAP Server. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LDAP.UserAttribute (Read or Write) Description To search, specify the user attribute.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LocalSecurity To manage the ability to configure iDRAC, use the objects in this group. iDRAC.LocalSecurity.LocalConfigDisabled (Read or Write) Description To configure iDRAC from Local RACADM, enable or disable the ability of the local user.
Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Lockdown To manage the ability to configure the iDRAC system configuration lockdown mode. iDRAC.Lockdown.SystemLockdownMode Description Enables or disables the iDRAC system configuration lockdown mode.
• Duplex • Dedicated NIC scan time • Shared NIC scan time iDRAC.NIC.Autoconfig (Read or Write) Description Sets the DHCP auto configuration operation. Legal Values • 0 — Disabled NOTE: • iDRAC does not perform DHCP configuration. 1 — Enable Once NOTE: • iDRAC performs DHCP configuration once. 2 — Enable Once After Reset NOTE: Configures after iDRAC reset. Default Values 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.NIC.
iDRAC.NIC.DedicatedNICScanTime (Read or Write) Description Wait time for the iDRAC to switch from dedicated mode to shared mode. Legal Values Integral values: 5–255 Default Value 5 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.DNSDomainFromDHCP (Read or Write) Description Specifies that the iDRAC DNS domain name must be assigned from the network DHCP server.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.DNSRacName (Read or Write) Description The iDRAC name. Legal Values String of up to 63 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.DNSRegister (Read or Write) Description Registers the iDRAC name with the DNS server.
Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.Failover (Read or Write) Description Enables or disables failover for iDRAC to switch from shared to dedicated.
Dependency None iDRAC.NIC.Selection (Read or Write) Description Specifies the current mode of operation for the iDRAC network interface controller. Legal Values • • • • • • • • Default Value 1 — Dedicated Write Privilege Configure iDRAC 1 — Dedicated 2 — LOM1 3 — LOM2 4 — LOM3 5 — LOM4 6 — LOM5 7 — LOM6 8 — LOM7 License Required iDRAC Express or iDRAC Enterprise Dependency None NOTE: On platforms with single LOM port, the legal values are applicable.
Legal Values • • • 0 — 10 1 — 100 2 — 1000 NOTE: You cannot manually set the Network Speed to 1000 MB. This option is available only if iDRAC.NIC.Autoneg is set to 1 (Enabled). Default Value 1 — 100 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot change NIC Speed unless AutoNeg is set to disabled. iDRAC.NIC.VLanEnable (Read Only) Description Enables or disables the VLAN capabilities of the iDRAC.
Default Value 0 — Both Write Privilege Configure iDRAC License Required RACADM Dependency None iDRAC.NIC.VLanPriority (Read Only) Description Specifies the VLAN priority for the network VLAN configuration. NOTE: This object is applicable only to iDRAC on Racks and Towers. Legal Values Integral values: 0–7 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.
iDRAC.NTPConfigGroup To configure the properties of NTP server, use the objects in this group. iDRAC.NTPConfigGroup.NTP1 (Read or Write) Description Configure NTP Server 1 Address. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NTPConfigGroup.NTP2 (Read or Write) Description Configure NTP Server 2 Address.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NTPConfigGroup.NTPMaxDist (Read or Write) Description NTP Maximum Distance Legal Values Integral values: 1–128 Default Value 16 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.OS-BMC To manage OS-BMC pass-through feature, use the object in this group. NOTE: In Autocomplete mode, the group OS-BMC will be autocompleted as OS_BMC.
iDRAC.OS-BMC.PTCapability (Read or Write) Description Operating System to iDRAC Pass Through Capability status. Legal Values • • Default Value Depends on the server capability. Write Privilege Configure iDRAC 0 — Capable 1 — Not Capable or Unknown License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.OS-BMC.PTMode (Read or Write) Description Enables the pass-through with shared LOM or USB. NOTE: To enable the pass-through, make sure that iDRAC.OSBMC.AdminState is enabled.
Dependency None iDRAC.Racadm To manage Remote RACADM connection settings, use the object in this group. iDRAC.Racadm.Enable (Read or Write) Description Enables or disables Remote RACADM interface. Legal Values • • Default Value Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Racadm.Timeout (Read or Write) Description Defines the idle timeout in seconds of the Remote RACADM interface.
iDRAC.Redfisheventing The objects in this group provide information on Redfish events. iDRAC.Redfisheventing.DeliveryRetryAttempts (Read or Write) Description Specifies the number of retry attempts made for Redfish event delivery. Legal Values Value ranges from 0 to 5. Default Value 3 Write Privilege Configure iDRAC License Required RACADM Dependency None iDRAC.Redfisheventing.
iDRAC.RemoteHost.SMTPPort (Read or Write) Description Specifies the destination port for email alerts. Legal Values Integral values: 1–65535 Default Value 25 Write Privilege Configure iDRAC License Required iDRAC Express Dependency None iDRAC.RemoteHosts.SMTPServerIPAddress (Read or Write) Description IPv4 or IPv6 address of the network SMTP server. Legal Values String representing a valid SMTP server IPv4, or IPv6 address, or DNS name Default Value 0.0.0.
Legal Values • • Default Value 0 — Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.RSM.RSMSetting (Read Only) Description Specifies the status of RSM setting. Legal Values • • • Default Value 2 — Manage and Monitor License Required iDRAC Express or iDRAC Enterprise Dependency None 0 — None 1 — Monitor 2 — Manage and Monitor iDRAC.Security Use the objects in this group to configure SSL certificate signing request settings.
iDRAC.Security.CsrEmailAddr (Read or Write) Description Specifies the CSR email address. Legal Values Valid email address string of up to 254 ASCII characters. Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Security.CsrKeySize (Read or Write) Description Specifies the SSL asymmetric key size for the CSRs.
iDRAC.Security.CsrOrganizationUnit (Read or Write) Description Specifies the CSR Organization Unit (OU). Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Security.CsrStateName (Read or Write) Description Specifies the CSR State Name (S).
iDRAC.Serial.BaudRate (Read or Write) Description Sets the Baud rate on the iDRAC serial port. Legal Values • • • • Default Value 115200 Write Privilege Configure iDRAC 9600 19200 57600 115200 License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Serial.Command (Read or Write) Description Specifies a serial command that is executed after the user logs in to the serial console interface.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Serial.IdleTimeout (Read or Write) Description The maximum number of seconds to wait before an idle serial console session is disconnected. Legal Values • • Default Value 300 Write Privilege Configure iDRAC 0 — No timeout Integral values: 60–10800 License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Serial.NoAuth (Read or Write) Description Enables or disables iDRAC serial console login authentication.
iDRAC.SerialRedirection.QuitKey (Read or Write) Description This key or key combination terminates the Virtual Console when using the console COM2 command. Legal Values The value must start with the ^ character, and must follow one of the characters a-z, A-Z, [,], \, ^, _ enclosed with single or double quotes. Eg: '^\\' or "^\\" NOTE: For local or remote RACADM, use "^\\\\" Default Value ^\ Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.
Write Privilege Login and configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.ServiceModule The objects in this group manages the properties of the ISM modules. iDRAC.ServiceModule.iDRACHardReset (Read or Write) Description Resets iDRAC when it is unresponsive. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required RACADM Dependency iDRAC.ServiceModule.
Legal Values • • • Default Value 2 — NA License Required iDRAC Express or iDRAC Enterprise Dependency None 0 — Not Present 1 — Present 2 — NA iDRAC.ServiceModule.OSInfo (Read or Write) Description Provides information about operating system through iDRAC Service Module. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.ServiceModule.
iDRAC.ServiceModule.ServiceModuleVersion (Read) Description Displays the installed version of iDRAC Service Module. Legal Values None Default Value None License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.ServiceModule.WatchdogRecoveryAction (Read and Write) Description Configures recovery action on watchdog alert.
iDRAC.SmartCard The objects in this group enable you to access iDRAC using a smart card. iDRAC.SmartCard.SmartCardCRLEnable (Read or Write) Description Enables or disables the Certificate Revocation List (CRL). Legal Values • • Default Value Not Applicable Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Enterprise Dependency To log on, enable Smart Card. iDRAC.SmartCard.SmartCardLogonEnable (Read or Write) Description Enables or disables Smart card login support.
iDRAC.SNMP.AgentEnable (Read or Write) Description Enables or disables the SNMP Agent on the iDRAC. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.SNMP.AlertPort (Read or Write) Description Specifies the SNMP alert port for traps.
iDRAC.SNMP.TrapFormat (Read or Write) Description Specifies the SNMP format. Legal Values • • • Default Value 0 — SNMPv1 Write Privilege Configure iDRAC 0 — SNMPv1 1 — SNMPv2 2 — SNMPv3 License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.SupportAssist The objects in this group enable you to configure the SupportAssist capabilities. iDRAC.SupportAssist.DefaultIPAddress Description Default workgroup name for saving SupportAssist collections to network share.
Dependency None iDRAC. SupportAssist. DefaultProtocol Description Default protocol (NFS/CIFS) for saving SupportAssist collections. Legal Values 1-NFS, 2-CIFS Default Value 2- CIFS License Required RACADM Dependency None iDRAC. SupportAssist.DefaultShareName Description Default password for saving SupportAssist collections to network share. Legal Values String of 0 to 64 characters length Default Value NA License Required RACADM Dependency None iDRAC.SupportAssist.
iDRAC.SupportAssist.EventBasedAutoCollection Description Indicates whether SupportAssist event based auto collection features is enabled on this system. Legal Values • • Default Value 0 - Disabled 0 - Disabled 1 - Enabled License Required RACADM Dependency Can be enabled only when SupportAssistEnableState is configured to 1-Enabled iDRAC.SupportAssist.FilterAutoCollections Description Option to receive E-mails from Dell on case creation and collection upload.
Legal Values String of 0 to 64 characters length Default Value NA License Required RACADM Dependency HostOSProxyConfigured should be 1=Yes iDRAC.SupportAssist.HostOSProxyPort Description Host OS proxy port. Legal Values Integer values from 0 to 65535. Default Value NA License Required RACADM Dependency HostOSProxyConfigured should be 1=Yes iDRAC.SupportAssist.HostOSProxyUserName Description Host OS proxy password.
Dependency Registration ID needs to be obtained before changing language settings. iDRAC.SupportAssist.ProSupportPlusRecommendationsR eport Description Indicates whether this server will be included for recommendations in ProSupport Plus Recommendations Report. Legal Values 0-Disabled, 1-Enabled Default Value 0-Disabled License Required RACADM Dependency ScheduleBasedAutoCollection should be enabled and set to weekly or monthly schedule. iDRAC.SupportAssist.
Default Value • • Write Privilege Configure iDRAC Index 1–4 — 0.0.0.0 Index 5–8 — :: License Required None Dependency None iDRAC.SNMP.Alert.Enable (Read or Write) Description Enables or disables SNMP alert for the given index. Legal Values • • Default Value Not Applicable Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required None Dependency None iDRAC.SNMP.Alert.SNMPv3UserID (Read Only) Description Indicates the index of the user to which this alert is configured.
iDRAC.SSH.Enable (Read or Write) Description Enables or disables SSH. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.SSH.Port (Read or Write) Description Specifies the port number for the iDRAC SSH interface.
Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.SysLog.PowerLogEnable (Read or Write) Description Enables or disables the Power Log feature. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Enterprise Dependency None iDRAC.SysLog.PowerLogInterval (Read or Write) Description Configure time delay for power logging.
Legal Values String of up to 63 ACSII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.SysLog.Server3 (Read or Write) Description Name of remote syslog server 3. Legal Values String of up to 63 ACSII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.SysLog.SysLogEnable (Read or Write) Description Enables or disables remote syslog.
Dependency None iDRAC.Telnet.Port (Read or Write) Description Specifies the port number for the iDRAC Telnet interface. Legal Values Integral values: 1–65535 Default Value 23 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Telnet.Timeout (Read or Write) Description Defines the Telnet idle timeout.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Time.TimeZoneOffset (Read or Write) Description Specifies the time zone offset (in minutes) from Greenwich Mean Time (GMT) or Coordinated Universal Time (UTC) to use for the iDRAC Time. Legal Values Integral values: -43200 to 46800 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Update.FwUpdatePath (Read or Write) Description Specifies TFTP path where iDRAC firmware image resides on TFTP server. Path is relative to TFTP root folder. Legal Values String of up to 255 ACSII characters. For example: /images/12G/ Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Update.
iDRAC.USB.ManagementPortMode (Read only) Description Displays the front panel USB mode. NOTE: The behaviour and legal values of this attribute differs from 13G to 14G. Legal Values • Default Value iDRAC Direct Only Write Privilege Not Applicable iDRAC Direct Only License Required iDRAC Express and iDRAC Enterprise Dependency Not Applicable iDRAC.USB.PortStatus Description Shows status set from BIOS for front panel USB port. This can be either Enabled or Disabled.
iDRAC.Users The objects in this group enable you to manage information about all iDRAC users. This group is indexed from 1 to 16. iDRAC.Users.Enable (Read or Write) Description Enables or disables an individual user. Legal Values • • Default Value 0 — Disabled. However, Root user is Enabled. Write Privilege Configure Users 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency Both username and password must be configured prior to enabling the user. iDRAC.Users.
Dependency Both username and password must be configured prior to setting this object. iDRAC.Users.MD5v3Key (Read or Write) Description Indicates the MD5 Hash of the SNMP V3 key. Legal Values String of 32 characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express Dependency User name must be configured prior to setting MD5v3Key. iDRAC.Users.Password (Read or Write) Description Configuring the iDRAC user password.
Legal Values Integral values: 0–511 (0x1FF) Default Value 0 Write Privilege Configure iDRAC and Configure User License Required iDRAC Express or iDRAC Enterprise Dependency Both user name and password must be configured prior to setting this object. iDRAC.Users.SHA1v3Key (Read or Write) Description Indicates the SHA1 Hash of the SNMP V3 key.
iDRAC.Users.SNMPv3PrivacyType (Read or Write) Description Configure SNMPv3 privacy protocol type. Legal Values • • • Default Value 2 — AES Write Privilege Configure iDRAC and Configure User 0 — None 1 — DES 2 — AES License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Users.SolEnable (Read or Write) Description Enables or Disables SOL for the user.
Legal Values • • Default value 1 — Read Only Write Privilege Login and configure iDRAC 1 — Read Only 0 — Read Write License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. Partition at the specified index must be created. iDRAC.vflashpartition.AttachState (Read or Write) Description Specifies if the vFlash SD partition is attached or detached.
iDRAC.vflashpartition.Size (Read or Write) Description Specifies the Size of the vFlash SD partition. Legal Values Integer value in MB Default value None Write Privilege Login and configure iDRAC License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. Partition at the specified index must be created. iDRAC.vflashpartition.VolumeLabel (Read or Write) Description Specifies the label assigned to the partition during the vFlash SD partition creation.
iDRAC.vflashsd.Health (Read or Write) Description Specifies current health status of the vFlash SD Card. Legal Values • • • • Default value OK Write Privilege Login and configure iDRAC OK Warning Critical Unknown License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. iDRAC.vflashsd.Initialized (Read or Write) Description Specifies if the vFlash SD card is initialized or not.
iDRAC.vflashsd.WriteProtect (Read or Write) Description Displays if the physical write protect is enabled or disabled on the vFlash SD card. Legal Values • • Default value None Write Privilege Login and configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. iDRAC.VirtualConsole The objects in this group enable you to manage virtual console configuration parameters of iDRAC. iDRAC.VirtualConsole.
Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualConsole.EncryptEnable (Read or Write) Description Encrypts the video in a Virtual Console session. Legal Values • • Default Value AES Write Privilege Configure iDRAC None AES License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualConsole.
iDRAC.VirtualConsole.PluginType (Read or Write) Description Specifies the plugin type to use while running virtual console from the browser. Legal Values • • • Default Value 0 — Active X Write Privilege Configure iDRAC 0 — Active X 1 — Java 2 — HTML5 License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualConsole.Port (Read or Write) Description Specifies the virtual KVM port.
Legal Values • • • Default Value 2 — AutoAttach Write Privilege Virtual Media 0 — Detached 1 — Attached 2 — AutoAttach License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualMedia.BootOnce (Read or Write) Description Enables or disables the virtual media boot once feature of the iDRAC.
Write Privilege Not Applicable License Required iDRAC Enterprise Dependency None iDRAC.VNCServer.Enable (Read or Write) Description Enables or disables VNC server on iDRAC. Legal Values • • Default value 0 — Disabled Write Privilege Login or configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Enterprise Dependency None iDRAC.VNCServer.LowerEncryptionBitLength (Read or Write) Description Lower encryption bit length.
Dependency None iDRAC.VNCServer.SSLEncryptionBitLength (Read or Write) Description Indicates the VNC server encryption state. Legal Values • • • • • Default value 0 — Disabled Write Privilege iDRAC Configure License Required iDRAC Enterprise Dependency None 0 — Disabled 1 — Auto negotiate 2— 128 bit or higher 3— 168 bit or higher 4— 256 bit or higher iDRAC.VNCServer.Timeout (Read or Write) Description VNC server idle timeout period in seconds.
iDRAC.WebServer.HttpPort (Read or Write) Description Specifies the port number for HTTP communication with the iDRAC. Legal Values Integral values: 1–65535 Default Value 80 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.WebServer.HttpsPort (Read or Write) Description Specifies the port number for HTTPs communication with the iDRAC.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.WebServer.SSLEncryptionBitLength (Read or Write) Description Indicates the web server encryption state. NOTE: If SSL encryption is set to 256-bit or higher, the cryptography settings for your virtual machine environment (JVM, IcedTea) may require installing the Unlimited Strength java Cryptography Extension Policy Files to permit usage of the iDRAC plugins such as vConsole with level of encryption.
Dependency None BIOS.BiosBootSettings You can manage the BIOS start settings using the objects in this group. BIOS.BiosBootSettings.BootSeq (Read or Write) Description Determines the Bios start sequence of the system. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if BootMode is set to UEFI NOTE: If BootMode is set to UEFI, legacy boot settings are not available in the system.
BIOS.BiosBootSettings.HddFailover (Read or Write) Description Specifies the devices in the Hard-Disk Drive Sequence menu that are attempted in the boot sequence. This property applies to BIOS Boot Mode only, and is disabled when Boot Mode is set to UEFI. When set to Disabled (default), only the first Hard-Disk device in the list is attempted to boot. When set to Enabled, all Hard-Disk devices are attempted in order, as listed in the Hard-Disk Drive Sequence.
Dependency None BIOS.BiosBootSettings.SetLegacyHddOrderFqddn (Read or Write) Description Specifies a list of FQDDs that has the legacy HDD list to apply on the next boot. In the attribute SetLegacyHddOrderFqdd, the value of n can be 1 to 16 Legal Values String of UEFI boot devices Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
BIOS.IntegratedDevices.EmbNic2 (Read or Write) Description Enables or disables the operating system interface of the embedded NIC2. Legal Values • • • • Default Value Not Applicable Write Privilege Server Control Enabled EnabledPxe EnablediScsi Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.EmbNic3 (Read or Write) Description Enables or disables the operating system interface of the embedded NIC3.
Legal Values • • • • Default Value Not Applicable Write Privilege Server Control Enabled EnabledPxe EnablediScsi Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.EmbVideo (Read or Write) Description Enables or disables the BIOS support for the embedded video controller. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.IntegratedNetwork2 (Read or Write) Description Enables or disables the integrated network card 2. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled DisabledOS License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.IntegratedRaid (Read or Write) Description Enables or disables the integrated RAID controller.
Legal Values • • Default Value Not Applicable Write Privilege Server Control On Off License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.InternalSdCardRedundancy (Read or Write) Description Sets the SD Card redundancy mode. Legal Values • • Default Value Not Applicable Write Privilege Server Control Mirror Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if InternalSdCard is set to 'Off'. BIOS.IntegratedDevices.
BIOS.IntegratedDevices.InternalUsb2 (Read or Write) Description Enables or disables the internal USB port 2. Legal Values • • Default Value Not Applicable Write Privilege Server Control On Off License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.IoatEngine (Read or Write) Description Enables or disables the I/O Acceleration technology (I/OAT) option.
Dependency None BIOS.IntegratedDevices.OsWatchdogTimer (Read or Write) Description Enables or disables timer initialization by the operating system. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.SriovGlobalEnable (Read or Write) Description Enables or disables BIOS configuration of Single Root I/O Virtualization (SR-IOV) devices.
BIOS.EmbServerMgmt.FrontLcd (Read or Write) Description Allows to display the default (Model name and number) or a user-defined string in the front-panel LCD. To modify the advanced features of the front-panel LCD, press F2 during POST to enter System Setup and then select iDRAC Settings. Legal Values • • • • Default Value None Write Privilege Server Control None UserDefined ModelNum Advanced License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.EmbServerMgmt.
Legal Values • • • • • Default Value Not Applicable Write Privilege Server Control OptimizerMode SpareMode MirrorMode AdvEccMode SpareWithAdvEccMode License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.MemOptimizer (Read or Write) Description Configure the memory optimizer setting. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.
Dependency None BIOS.MemSettings.NodeInterleave (Read or Write) Description If the system is configured with matching memory this field enables node interleaving. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.RedundantMem (Read or Write) Description Enables or disables the redundant memory feature.
Legal Values • • Default Value Not Applicable Write Privilege Server Control NotInUse InUse License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.Serialdbgout (Read or Write) Description Enables or disables the Serial Debug Out option. Legal Values • • Default Value Not Applicable Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.
BIOS.MemSettings.SysMemSpeed (Read or Write) Description Indicates the current clock frequency of the main memory. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.SysMemType (Read or Write) Description Indicates the current type of main memory installed in the system.
BIOS.MiscSettings To manage the miscellaneous objects settings, use the object in this group. BIOS.MiscSettings.AssetTag (Read or Write) Description Displays the current asset tag and the asset tag can be modified. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.ErrPrompt (Read or Write) Description Enables or disables the F1 and F2 prompt on error.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.ReportKbdErr (Read or Write) Description Enables or disables the keyboard-related error messages to be reported at system startup. Legal Values • • Default Value Not Applicable Write Privilege Server Control Report No report License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.SystemUefiShell (Read or Write) Description Enables or disables the system UEFI shell as UEFI boot option. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.
BIOS.OneTimeBoot.OneTimeBootMode (Read or Write) Description Configure the one time boot mode setting. Legal Values • • • • Default Value Not Applicable Write Privilege Server Control Disabled OneTimeBootSeq OneTimeHddSeq OneTimeUefiBootSeq License Required iDRAC Express or iDRAC Enterprise Dependency None NOTE: On a Dell 13th generation of PowerEdge server, to set the value from OneTimeBootMode to OneTimeUefiBootSeq, you must boot the server in UEFI mode. BIOS.OneTimeBoot.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if OneTimeBootMode is not set to OneTimeHddSeq BIOS.OneTimeBoot.OneTimeUefiBootSeqDev (Read or Write) Description Configure the one time UEFI Boot Sequence device.
Dependency None BIOS.ProcSettings.DcuIpPrefetcher (Read or Write) Description Enables or disables Data Cache Unit (DCU) IP Prefetcher. Legal Values • • Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None Enabled Disabled BIOS.ProcSettings.DcuStreamerPrefetcher (Read or Write) Description Enables or disables Data Cache Unit (DCU) Streamer Prefetcher.
Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.LogicalProc (Read or Write) Description To enable report all logical processors and to disable report one logical processor per core. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.
BIOS.ProcSettings.Proc1ControlledTurbo (Read or Write) Description Controls the turbo engagement. NOTE: You can enable this option only when System Profile is set to Performance. Legal Values • • • • • Default Value Not Applicable Write Privilege Server Control Disabled ControlledTurboLimit ControlledTurboLimitMinus1 ControlledTurboLimitMinus2 ControlledTurboLimitMinus3 License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.
Dependency None BIOS.ProcSettings.Proc1NumCores (Read or Write) Description Number of cores in the processor package. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc2Brand (Read or Write) Description Provides the processor brand name.
Write Privilege Server control License Required RACADM Dependency Requires the DPAT Pro license to make it visible. It can be edited only if the Number of Cores per Processor is set to Custom. BIOS.ProcSettings.Proc2Id (Read or Write) Description Processor's family model and stepping values. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc3Brand (Read or Write) Description Brand text provided by the processor manufacturer. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc3ControlledTurbo (Read or Write) Description Controls the turbo engagement.
BIOS.ProcSettings.Proc3Id (Read or Write) Description Processor's family model and stepping values. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc3L2Cache (Read or Write) Description Amount of memory in the corresponding processor cache.
BIOS.ProcSettings.Proc4Brand (Read or Write) Description The processor manufacturer provides brand text Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc4ControlledTurbo (Read or Write) Description Controls the turbo engagement. NOTE: You can enable this option only when System Profile is set to Performance.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc4L2Cache (Read or Write) Description Amount of memory in the corresponding processor cache. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc4L3Cache (Read or Write) Description Amount of memory in the corresponding processor cache.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcAdjCacheLine (Read or Write) Description Enables or disables the system optimization for applications that require high utilization of sequential memory access. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcBusSpeed (Read or Write) Description Bus speed of the processor.
Legal Values • • • • • • • • • • • Default Value Not Applicable Write Privilege Server Control Single All 1 2 4 6 8 10 12 14 16 License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcCoreSpeed (Read or Write) Description Clock speed of the processor. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcHpcMode (Read or Write) Description Configure processor's HPC mode. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.
BIOS.ProcSettings.ProcHyperTransport (Read or Write) Description Specifies the supported HyperTransport I/O Link Specification. Legal Values • • Default Value Not Applicable Write Privilege Server Control HT1 HT3 License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcSoftwarePrefetcher (Read or Write) Description Enables or disables the hardware prefetcher for considering software prefetches when detecting strides for prefetch requests.
Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if the ProcVirtualization attribute is set to Disabled. BIOS.ProcSettings.QpiBandwidthPriority (Read or Write) Description Sets the bandwidth priority to compute (default) or I/O. Legal Values • • Default Value Not Applicable Write Privilege Server Control InputOutput Compute License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.
BIOS.ProxyAttributes The objects in this group manage the legacy boot protocol of LOM. BIOS.ProxyAttributes.EmbNicPortnBootproto (Read or Write) Description Controls the Legacy Boot Protocol of the LOM port specified by the Embedded NIC port. Assists in system management software and does not appear in system BIOS setup. The value of n can be 1–4. This attribute returns Unknown when read. The LOM port legacy boot protocol setting is not changed when Unknown is written.
BIOS.PxeDev1Settings.PxeDevnInterface (Read or Write) Description Indicates the NIC Interface used for the specified PXE device. For the attribute PxeDevnInterface, the value of n can be 1 — 4. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.PxeDev1Settings.PxeDevnProtocol (Read or Write) Description Controls the PXE protocol used for the specified PXE device.
BIOS.PxeDev1Settings.PxeDevnVlanPriority (Read or Write) Description Indicates the VLAN priority for the specific PXE device. For the attribute PxeDevnVlanPriority, the value of n can be 1 — 4. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings Use the objects in this group to configure the BIOS SATA settings. BIOS.SataSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.eSataPort1Model (Read or Write) Description Displays the drive model of the selected device. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortA (Read or Write) Description Sets the drive type of the selected device.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortAModel (Read or Write) Description Displays the drive model of the selected device. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortB (Read or Write) Description Sets the drive type of the selected device.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortBModel (Read or Write) Description Displays the drive model of the selected device. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.
BIOS.SataSettings.SataPortCDriveType (Read or Write) Description Indicates type of device attached to this SATA port. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortCModel (Read or Write) Description Displays the drive model of the selected device.
BIOS.SataSettings.SataPortDDriveType (Read or Write) Description Indicates type of device attached to this SATA port. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortDModel (Read or Write) Description Displays the drive model of the selected device.
BIOS.SataSettings.SataPortEDriveType (Read or Write) Description Indicates type of device attached to this SATA port. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortEModel (Read or Write) Description Displays the drive model of the selected device.
BIOS.SataSettings.SataPortFDriveType (Read or Write) Description Indicates type of device attached to this SATA port. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortFModel (Read or Write) Description Displays the drive model of the selected device.
BIOS.SataSettings.SataPortGDriveType (Read or Write) Description Indicates type of device attached to this SATA port. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortGModel (Read or Write) Description Displays the drive model of the selected device.
BIOS.SataSettings.SataPortHDriveType (Read or Write) Description Indicates type of device attached to this SATA port. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortHModel (Read Only) Description Displays the drive model of the selected device.
Dependency None BIOS.SataSettings.SataPortIDriveType (Read or Write) Description Indicates the type of device attached to this SATA port. Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortIModel (Read or Write) Description Displays the drive model of the selected device.
Dependency None BIOS.SataSettings.SataPortJDriveType (Read or Write) Description Indicates the type of device attached to this SATA port. Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortJModel (Read or Write) Description Displays the drive model of the selected device.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SerialCommSettings.ExtSerialConnector (Read or Write) Description Associate the External Serial Connector to Serial 1 or Serial 2 or Remote Access Device. Legal Values • • • Default Value Not Applicable Write Privilege Server Control Serial1 Serial2 RemoteAccDevice License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SerialCommSettings.
BIOS.SerialCommSettings.SerialComm (Read or Write) Description Controls the serial communication options. Legal Values • • • • • Default Value Not Applicable Write Privilege Server Control Off OnNoConRedir OnConRedirCom1 OnConRedirCom2 OnConRedir License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SerialCommSettings.SerialPortAddress (Read or Write) Description Port address for the Serial Devices.
BIOS.SlotDisablement.Slot2 (Read or Write) Description Control the configuration of the card installed in slot 2. Legal Values • • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled BootDriverDisabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.Slot3 (Read or Write) Description Control the configuration of the card installed in slot 3.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.Slot6 (Read or Write) Description Control the configuration of the card installed in slot 6. Legal Values • • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled BootDriverDisabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.Slot9 (Read or Write) Description Controls the configuration of the card installed in this slot. You can set one of the following options for each card: • • • Enabled: The card is available during POST or to the operating system. Disabled: The card is not available during POST or to the operating system.
BIOS.SysInformation To view information about system configuration, use the objects in this group. BIOS.SysInformation.SysMfrContactInfo (Read or Write) Description Provides information about the Original Equipment Manufacturer of this system. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysInformation.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysInformation.SystemModelName (Read or Write) Description Provides the product name of the system. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysInformation.SystemServiceTag (Read or Write) Description The Service Tag assigns the Original Equipment Manufacturer of this system.
BIOS.SysProfileSettings.CollaborativeCpuPerfCtrl (Read/ Write) Description Enables or disables the CPU power management control. When ProcPwrPerf is not set to SysDbpm in Custom mode, changing this setting does not affect system performance. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Enabled only when SysProfileSettings.ProcPwrPerf is set to SysDbpm in Custom mode. BIOS.
Legal Values • • • • • • Default Value Not Applicable Write Privilege Server Control MaxPerf 1600MHz 1333MHz 1067MHz 800MHz MaxReliability License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.MemPatrolScrub (Read or Write) Description Patrol scrubbing is a feature that searches the memory for errors and repairs correctable errors to prevent the accumulation of memory errors.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.MemVolt (Read or Write) Description Sets the DIMM voltage selection. Legal Values • • • Default Value Not Applicable Write Privilege Server Control AutoVolt Volt135V Volt15V License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.
BIOS.SysProfileSettings.ProcC1E (Read or Write) Description When enabled, the processor is allowed to switch to minimum performance state when idle. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.ProcCStates (Read or Write) Description Enables or disables the processor C-States.
License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.ProcTurboMode (Read or Write) Description When enabled, the processor can operate in Turbo Boost Mode. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysProfileSettings.UncoreFrequency (Read or Write) Description Selects the processor uncore frequency. Legal Values • • • Default Value Not Applicable Write Privilege Server Control DynamicUFS MaxUFS MinUFS License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysProfileSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysSecurity.AcPwrRcvry is set to Off. BIOS.SysSecurity.AcPwrRcvryDelay (Read or Write) Description Specifies how the system supports the staggering of power-up after AC power has been restored to the system. Legal Values • • • Default Value Not Applicable Write Privilege Server Control Immediate User Random License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
Legal Values • • • Default Value Not Applicable Write Privilege Server Control Unlocked Limited Locked License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.IntelTxt (Read or Write) Description Enables or disables Trusted Execution technology. NOTE: When the IntelTxt value is set to ‘on’, then the following values are set: TpmActivation=NoChange (Pending Value=NoChange), TpmClear=No (Pending Value=No), TpmSecurity=OnPbm (Pending Value=OnPbm).
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.PwrButton (Read or Write) Description Enables or disables the power button on the front panel. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.SHA256SetupPassword (Read or Write) Description Indicates the SHA256 hash of the setup password. Legal Values String of 64 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.
BIOS.SysSecurity.SysPassword (Read or Write) Description Provides the system password. Optional parameter –o is used with this object to provide old password as an authentication for changing the previously configured password to the new password. The password can include the following: • • • • Up to 32 characters including whitespace. Contain numbers 0 through 9. Only lower case alphabets are accepted. Special characters accepted are +, ", ,, -, ., /, ;, [, \, ], `.
Legal Values • • • Default Value Not Applicable Write Privilege Server Control No change Activate Deactivate License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.TcmClear (Read or Write) Description Warns that clearing the TPM causes loss of all keys in the TPM. It may affect starting the operating system.
BIOS.SysSecurity.TpmClear (Read or Write) Description Warns that clearing the TPM causes loss of all keys in the TPM. It may affect starting the operating system. Legal Values • • Default Value Not Applicable Write Privilege Server Control Yes No License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysSecurity.TpmSecurity is set to Off. BIOS.SysSecurity.TpmFirmware Description Displays the firmware version of the Trusted Platform Module (TPM).
Write Privilege Server control License Required RACADM Dependency None BIOS.SysSecurity.TpmSecurity (Read or Write) Description Controls the reporting of the Trusted Platform Module (TPM) in the system. Legal Values • • • Default Value Not Applicable Write Privilege Server Control Off OnPbm OnNoPbm License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.TPMStatus (Read Only) Description Displays the status of TPM.
BIOS.UefiBootSettings.UefiPxeIpVersion (Read or Write) Description Enables to select the IPv4 PXE booting (default) or IPv6 PXE booting when in UEFI boot mode. This property is disabled in BIOS boot mode. If this property is modified, the PXE options in the UEFI boot sequence is replaced on the next restart. Legal Values • • Default Value Not Applicable Write Privilege Server Control IPv4 IPv6 License Required iDRAC Express or iDRAC Enterprise Dependency None FC.
FC.FCDevice.FamilyVersion (Read Only) Description Indicates the firmware’s family version. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.FCDevice.PCIDeviceID (Read Only) Description Indicates the device ID present in the PCI configuration space.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.FCTarget.FirstFCTargetWWPN (Read or Write) Description Specifies the World Wide Port Name of the first Fibre Channel boot target. Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.FCTarget.SecondFCTargetLUN (Read or Write) Description Specifies the LUN of the second Fibre Channel boot target.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.FabricLoginTimeout (Read or Write) Description Sets the SAN Fabric login time out. Legal Values Not Applicable Default Value 3000 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.FabricLoginRetryCount (Read or Write) Description Sets the current SAN Fabric login retry count.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.HardZoneAddress (Read or Write) Description Sets the Hard Zone address. Legal Values Not Applicable Default Value 0 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.LinkDownTimeout (Read or Write) Description Sets the Link down time out.
FC.HBAConfig.PortDownTimeout (Read or Write) Description Sets the target port down time out. Legal Values Not Applicable Default Value 3000 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.PortLoginRetryCount (Read or Write) Description Sets the target Port login retry count.
FC.PortConfig.FCDevice (Read Only) Description Displays the version of the device and firmware. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.PortConfig.FCTarget (Read Only) Description Enables the connection, configure boot, and communication parameters for the Fibre Channel boot target(s).
Legal Values • • • • • • Default Value Auto Write Privilege Sever Control Auto 1G 2G 4G 8G 16G License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.PortConfig.VirtualWWN (Read or Write) Description Indicates the virtual Fibre Channel World Wide Node Name (WWN). Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.PortConfig.
Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn The following section provides information about the objects in the NIC.ConfigureFormn. NIC.ConfigureFormn.BusDeviceFunction (Read Only) Description Indicates the value of the bus device function.
Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.iScsiOffloadMode (Read or Write) Description Enables or disables the iSCSI off load on the partition. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.
Dependency Not Applicable NIC.ConfigureFormn.WWN (Read Only) Description Indicates the Fibre Channel World Wide Node name identifier for FCoE. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.WWPN (Read Only) Description Indicates the Fibre Channel World Wide Port Name identifier for FCoE.
Legal Values Not Applicable Default Value 00:00:00:00:00:00 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.VirtIscsiMacAddr (Read or Write) Description Assigns the MAC address for partition iSCSI off load. Legal Values Not Applicable Default Value 00:00:00:00:00:00 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.
Legal Values • • Default Value Not Applicable Write Privilege Not Applicable Available Unavailable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.DCBSettings.DCBExchangeProtocol (Read Only) Description Indicates whether Data Center Bridging (DCB) Exchange Protocol capability is supported. Legal Values • • Default Value Not Applicable Write Privilege Not Applicable Available Unavailable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.
NIC.DeviceLevelConfig To manage the device level configurations, use the objects in this group. NOTE: To get the actual supported values for BIOS, NIC, and FC components, query the help with an index. If you query without an index, the generic help is displayed. NIC.DeviceLevelConfig.EVBModesSupport (Read Only) Description Indicates the type of EVB Modes supported.
NIC.DeviceLevelConfig.SRIOVSupport (Read Only) Description Indicates whether SR-IOV capability is supported. Legal Values • • Default Value Not Applicable Write Privilege Not Applicable Available Unavailable License Required iDRAC Express or iDRAC Enterprise Dependency` None NIC.DeviceLevelConfig.VirtualizationMode (Read or Write) Description Specifies the type of virtualization used by the controller on all ports.
Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCOECapabilities.MaxIOsPerSession (Read Only) Description Indicates the maximum number of IOs supported per session. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCOECapabilities.
Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCOECapabilities.MaxNumberOfFCTargets (Read Only) Description Indicates the maximum number of FC targets supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCOECapabilities.
Dependency None NIC.FCoEConfiguration The following section provides information about the objects in the NIC.FCoEConfiguration group. NIC.FCoEConfiguration.ConnectFirstFCoETarget (Read or Write) Description Specifies whether FCoE initiator is used to connect to the first FCoE storage target defined. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEConfiguration.
NIC.FCoEConfiguration.BootOrderSecondFCoETarget (Read or Write) Description Specifies the port's second defined target in the FCoE boot. Legal Values Not Applicable Default Value 0 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCoEConfiguration.BootOrderThirdFCoETarget (Read or Write) Description Specifies the port's third defined target in the FCoE boot.
License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEConfiguration.FirstFCoEWWPNTarget (Read or Write) Description World Wide Port Name (WWPN) of the first FCoE storage target. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEConfiguration.MTUParams (Read or Write) Description Configure the MTU setting.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams.FCoEFabricDiscoveryRetryCnt (Read or Write) Description Retry count for FCoE fabric discovery. Legal Values Values: 0–60 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams.
NIC.FCoEGenParams.FCoELunBusyRetryCnt (Read or Write) Description Specifies the number of connection retries the FCoE boot initiator will attempt if the FCoE target LUN is busy. Legal Values Values: 0–60 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams.FCoETgtBoot (Read or Write) Description Enables the FCoE initiator to start system to the FCoE target.
Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FrmwImgMenu.FamilyVersion (Read Only) Description Indicates the firmware family version information. Legal Values String of up to 8 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.GlobalBandwidthAllocation The following section provides information about the objects in the NIC.
NIC.IscsiFirstTgtParams The following section provides information about the objects in the NIC.IscsiFirstTgtParams group. NIC.IscsiFirstTgtParams.AddressingMode (Read or Write) Description Enables or disables the connection to the first iSCSI target. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiFirstTgtParams.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiFirstTgtParams.FirstTgtChapPwd (Password) Description Specifies the first iSCSI storage target Challenge-Handshake Authentication Protocol (CHAP) secret (target CHAP password).
NIC.IscsiFirstTgtParams.FirstTgtIscsiName (Read or Write) Description Set the iSCSI Qualified Name (IQN) of the first iSCSI storage target. Legal Values String of up to 223 ASCII characters NOTE: The legal value range may be smaller than the maximum size of 223, based on the vendor configuration of the NIC cards. Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable.
Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.IscsiGenParams.DhcpVendId (Read or Write) Description Control what Vendor ID is presented to the DHCP service. Legal Values String of up to 255 ASCII characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.
NIC.IscsiGenParams.IpVer (Read or Write) Description Controls whether IPv4 or IPv6 network addressing is used for iSCSI initiator and targets. Legal Values • • • Default Value IPv4 Write Privilege Server Control IPv4 IPv6 None License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.
Dependency Not Applicable NIC.IscsiGenParams.IscsiVLanMode (Read or Write) Description Enables or disables the Virtual LAN mode for iSCSI boot. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiGenParams.LnkUpDelayTime (Read or Write) Description Set the time to allow for link to establish before driver initialization.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if IscsiGenParams.IpVer is set to 'IPv6' and VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.TcpTimestmp (Read or Write) Description Enables or disables use of TCP timestamps in network packets as defined in RFC 1323. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.
NIC.IscsiInitiatorParams.IscsiInitiatorChapPwd (Read or Write) Description Set the iSCSI initiator Challenge-Handshake Authentication Protocol (CHAP) secret (password). Legal Values String of 12–16 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiInitiatorParams.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiInitiatorParams.IscsiInitiatorPrimDns (Read or Write) Description Specifies the Primary DNS IP address of the iSCSI initiator.
NIC.IscsiInitiatorParams.IscsiInitiatorSubnetPrefix (Read or Write) Description Specifies the IPv6 Subnet Mask Prefix of the iSCSI initiator. Legal Values String of 2–39 characters (IPv6 Subnet) Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondaryDeviceParams The following section provides information about the objects in the NIC.
NIC.IscsiSecondaryDeviceParams.UseIndTgtPortal (Read or Write) Description Specifies whether to use Independent Target Portal when multipath I/O is enabled. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondTgtParams To configure the iSCSIsecond storage, use the objects in this group. NIC.IscsiSecondTgtParams.
NIC.IscsiSecondTgtParams.SecondTgtChapId (Read or Write) Description Specifies the second iSCSI storage target Challenge-Handshake Authentication Protocol (CHAP) ID Legal Values Values: 0–128. Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondTgtParams.
Legal Values • • Default Value IPv4 Write Privilege Server Control IPv4 IPv6 License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiSecondTgtParams.SecondTgtIscsiName (Read or Write) Description Specifies the iSCSI Qualified Name (IQN) of the second iSCSI storage target. Legal Values String of up to 223 characters NOTE: The legal value range may be smaller than the maximum size of 223, based on the vendor configuration of the NIC cards.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICConfig.BootOptionROM (Read or Write) Description Controls the enablement of legacy Boot Protocols in the Option ROM. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICConfig.BootRetryCnt (Read or Write) Description Specifies the number of attempts when the start is unsuccessful.
NIC.NICConfig.HideSetupPrompt (Read or Write) Description Enables or disables the option ROM setup prompt during Power On Self Test (POST). Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICConfig.LegacyBootProto (Read or Write) Description Select a non-UEFI network start protocol.
Default Value 0 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICConfig.VLanId (Read or Write) Description Specifies the ID (tag) for the VLAN Mode. Legal Values Values: 1–4095 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency VLanMode must be enabled. NIC.NICConfig.
NIC.NICPartitioningConfig.ConfigureFormn (Read Only) Description Configures the partition functionality and display the assigned address. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICPartitioningConfig.PartitionState (Read Only) Description Indicates the current enablement state of the partition.
NIC.VndrConfigGroup The objects in this group manage the vendor configuration settings. NIC.VndrConfigGroup.BusDeviceFunction (Read Only) Description Indicates the BIOS assigned PCIe. Legal Values String of up to 8 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.BlnkLeds (Read or Write) Description Identifies the physical network port by blinking the associated LED.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.DCBXSupport (Read Only) Description Indicates whether Data Center Bridging (DCB) capability is supported. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.DeviceName (Read Only) Description Official product name of the device.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.FCoEOffloadSupport (Read Only) Description Indicates whether FCoE Offload capability is supported. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.FeatureLicensingSupport (Read Only) Description Indicates whether Dell Feature Licensing capability is supported.
Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.iSCSIBootSupport (Read Only) Description Indicates whether iSCSI Boot capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.
Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.LinkStatus (Read Only) Description Indicates the physical network link status that reports the controller. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.
Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.NWManagementPassThrough (Read Only) Description Indicates whether the Network Management Pass-Through capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.
Legal Values String of up to 4 characters Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.PXEBootSupport (Read Only) Description Indicates whether PXE Boot capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.
Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.TXBandwidthControlMaximum (Read Only) Description Indicates whether Transmit (TX) Bandwidth Control Maximum capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.
Legal Values String of up to 17 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.VirtIscsiMacAddr (Read or Write) Description Programmatically assignable MAC address for iSCSI offload. Programmatic write for support of I/O Identity feature.
Legal Values String of up to 23 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.VirtWWPN (Read or Write) Description Programmatically assignable Fibre Channel World Wide Port Name identifier for FCoE. Legal Values String of up to 23 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.
Storage.Controller.BackgroundInitializationRate (Read or Write) Description The Background Initialization (BGI) rate is the percentage of the system's resources dedicated to perform the background initialization of a virtual disk after it is created. Legal Values Values: 0–100 Default value 100 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.
Dependency None Storage.Controller.ControllerBootMode (Read or Write) Description This property indicates the Controller Boot Mode setting on the controller. Legal Values • • • • Default Value Not Applicable Write Privilege Server Control User Mode Continue Boot On Error Headless Mode Continue On Error Headless Safe Mode License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.PatrolReadMode (Read or Write) Description Patrol Read is a feature for identifying disk errors to avoid disk failures and data loss or corruption. The Patrol Read only runs on the disks that are used in a virtual disk or that are hot-spare.
Legal Values • • Default value Automatic Write Privilege Server Control Automatic Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.RebuildRate (Read or Write) Description The Rebuild Rate is the percentage of the system's resources dedicated to rebuilding a failed disk when a rebuild is necessary.
Storage.Controller.SupportEnhancedAutoForeignImport (Read Only) Description This is a read only attribute. This property indicates if this controller supports enhanced auto import of foreign configurations. Legal Values • • Default Value Not Applicable Write Privilege Configure iDRAC Supported Not Supported License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.SupportRAID10UnevenSpans (Read Only) Description This is a read-only attribute.
Default Value Not Applicable License Required RACADM Dependency None Storage.enclosure.AssetTag Description Displays the asset tag information for the enclosure Legal Values string of 0 to 10 characters Default Value Not Applicable License Required RACADM Dependency None Storage.enclosure.BackplaneCurrentMode (Read Only) Description Displays the current mode of the backplane. Legal Values storage.enclosure.
storage.enclosure.supportedSplitModes(Read Only) Description List of supported split modes on this backplane. Legal Values The values are dynamic, it depends on the platform. Default Value Not Applicable Write Privilege Not Applicable License Required RACADM Dependency None Storage.PhysicalDisk The objects in this group manage storage physical disk drive attributes. This group is indexed. The following section provides information about the objects in this group. Storage.PhysicalDisk.
Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.PhysicalDisk.RaidType Description Indicates the metadata type on the disk. Legal Values • • • • Default Value Not Applicable None Software RAID Windows Software RAID Hardware RAID License Required RACADM Dependency None Storage.PhysicalDisk.T10PICapability (Read Only) Description This is a read-only attribute. This property indicates if this physical disk drive supports T10 PI.
Storage.VirtualDisk.DiskCachePolicy (Read or Write) Description Set the physical disk drive caching policy of all members of a Virtual Disk by enabling the Disk Cache Policy. When this feature is enabled, the physical disk drive writes data to the physical disk drive cache before writing it to the physical disk drive. Because it is faster to write data to the cache than to a disk, enabling this feature can improve system performance.
Storage.VirtualDisk.WritePolicy (Read or Write) Description The write policies specify whether or not the controller sends a write-request completion signal as soon as the data is in the cache or after it has been written to disk. NOTE: Storage.VirtualDisk.WritePolicy attribute is read-only for few PERCs—for example, H330.
5 Deprecated and New Subcommands The following table provides the list of deprecated subcommands and equivalent new subcommands.
6 New Groups and Objects for 14th generation of PowerEdge servers The following table provides the list of new groups and new objects added for 14G. Groups Objects iDRAC.GroupManager iDRAC.GroupManager.GlobalState(Read or Write) iDRAC.GroupManager.GroupName(Read) iDRAC.GroupManager.GroupUID(Read) iDRAC.GUI iDRAC.GUI.SecurityPolicyMessage iDRAC.Security iDRAC.Security.FIPSMode (Read or Write) iDRAC.SerialRedirection iDRAC.SerialRedirection.QuitKey (Read or Write) iDRAC.ServerBoot iDRAC.ServerBoot.
Groups Objects Storage.Enclosure.Assettag System.pcieSlotLFM System. pcieSlotLFM.3rdPartyCard(Read) System.pcieSlotLFM. CardType (Read) System.pcieSlotLFM. CustomLFM (Read or Write) System.pcieSlotLFM .LFMMode(Read or Write) System.pcieSlotLFM.MaxLFM (Read) System.pcieSlotLFM.Slot (Read) System.pcieSlotLFM.SlotState (Read) System.pcieSlotLFM.TargetLFM System.pcieSlotLFM. CardType (Read) System.pcieSlotLFM. CustomLFM (Read or Write) System.pcieSlotLFM .LFMMode(Read or Write) System.pcieSlotLFM.
Groups Objects System.pcieSlotLFM.
7 Legacy and New Groups and Objects The following table provides the list of legacy groups and objects and equivalent groups and objects. Legacy Groups and Objects New Groups and Objects idRacInfo iDRAC.Info idRacType Type idRacProductInfo Product idRacDescriptionInfo Description idRacVersionInfo Version idRacBuildInfo Build idRacName Name cfgActiveDirectory iDRAC.
Legacy Groups and Objects New Groups and Objects cfgADGcRootDomain GCRootDomain cfgLanNetworking iDRAC.Nic cfgNicEnable Enable cfgNicMacAddress MACAddress cfgDNSRacName DNSRacName cfgNicSelection Selection cfgNicFailoverNetwork Failover cfgDNSDomainName DNSDomainName cfgDNSDomainNameFromDHCP DNSRacName cfgDNSRegisterRac DNSRegister cfgNicVLanEnable VLanEnable cfgNicVLanID VLanID cfgNicVLanPriority VLanPriority iDRAC.
Legacy Groups and Objects New Groups and Objects cfgIPv6Address3 Address3 cfgIPv6Address4 Address4 cfgIPv6Address5 Address5 cfgIPv6Address6 Address6 cfgIPv6Address7 Address7 cfgIPv6Address8 Address8 cfgIPv6Address9 Address9 cfgIPv6Address10 Address10 cfgIPv6Address11 Address11 cfgIPv6Address12 Address12 cfgIPv6Address13 Address13 cfgIPv6Address14 Address14 cfgIPv6Address15 Address15 cfgIPv6DNSServersFromDHCP6 DNSFromDHCP6 cfgIPv6DNSServer1 DNS1 cfgIPv6DNSServer2 DNS2 cfgSer
Legacy Groups and Objects New Groups and Objects cfgServerPowerLastWeekAvg Avg.LastWeek cfgServerPowerLastHourMinPower Min.LastHour cfgServerPowerLastHourMinTime Min.LastHour.Timestamp cfgServerPowerLastHourMaxPower Max.LastHour cfgServerPowerLastHourMaxTime Max.LastHour.Timestamp cfgServerPowerLastDayMinPower Min.LastDay cfgServerPowerLastDayMinTime Min.LastDay.Timestamp cfgServerPowerLastDayMaxPower Max.LastDay cfgServerPowerLastDayMaxTime Max.LastDay.
Legacy Groups and Objects New Groups and Objects cfgServerPowerSupplyType Type cfgServerPowerBusMonitoring PMBusMonitoring cfgUserAdmin iDRAC.Users cfgUserAdminIndex NA cfgUserAdminUserName UserName cfgUserAdminPassword Password cfgUserAdminEnable Enable cfgUserAdminPrivilege Privilege cfgUserAdminIpmiLanPrivilege IpmiLanPrivilege cfgUserAdminIpmiSerialPrivilege IpmiSerialPrivilege cfgUserAdminSolEnable SolEnable cfgRemoteHosts iDRAC.
Legacy Groups and Objects New Groups and Objects Enable Port Timeout cfgSsnMgtSshIdleTimeout iDRAC.SSH Enable Port Timeout cfgSsnMgtRacadmTimeout iDRAC.Racadm Enable Timeout cfgSsnMgtConsRedirMaxSessions iDRAC.VirtualConsole EncryptEnable Enable PluginType LocalVideo Port MaxSessions Timeout AccessPrivilege cfgSsnMgtWebserverTimeout iDRAC.Webserver Enable HttpPort Timeout HttpsPort LowerEncryptionBitLength [cfgSerial] iDRAC.
Legacy Groups and Objects New Groups and Objects cfgSerialConsoleCommand Command cfgSerialHistorySize HistorySize iDRAC.SerialRedirection cfgSerialConsoleQuitKey QuitKey cfgSerialCom2RedirEnable Enable cfgSerialTelnetEnable iDRAC.Telnet cfgSerialSshEnable iDRAC.SSH [cfgOobSnmp] iDRAC.SNMP cfgOobSnmpAgentEnable AgentEnable cfgOobSnmpAgentCommunity AgentCommunity [cfgNetTuning] cfgNetTuningNic100MB iDRAC.Nic cfgNetTuningNicFullDuplex iDRAC.Nic cfgNetTuningNicMtu iDRAC.
Legacy Groups and Objects New Groups and Objects cfgRacTuneIpRangeMask=255.255.255.0 RangeMask iDRAC.Time cfgRacTuneTimezoneOffset=0 TimeZoneOffset cfgRacTuneDaylightOffset=0 DaylightOffset cfgRacTuneAsrEnable=1 TBD cfgRacTunePlugintype=0 iDRAC.VirtualConsole iDRAC.LocalSecurity cfgRacTuneCtrlEConfigDisable=0 PrebootConfig cfgRacTuneLocalConfigDisable=0 LocalConfig cfgRacTuneVirtualConsoleAuthorizeMultipleSessions=0 iDRAC.VirtualConsole ifcRacManagedNodeOs System.
Legacy Groups and Objects New Groups and Objects cfgLdapBaseDN BaseDN cfgLdapUserAttribute UserAttribute cfgLdapGroupAttribute GroupAttribute cfgLdapGroupAttributeIsDN GroupAttributeIsDN cfgLdapBindDN BindDN # cfgLdapBindPassword BindPassword cfgLdapSearchFilter SearchFilter cfgLdapCertValidationEnable CertValidationEnable cfgLdapRoleGroup iDRAC.LDApRole cfgLdapRoleGroupIndex NA cfgLdapRoleGroupDN DN cfgLdapRoleGroupPrivilege Privilege cfgStandardSchema iDRAC.
Legacy Groups and Objects New Groups and Objects cfgIpmiSolBaudRate BaudRate cfgIpmiSolMinPrivilege MinPrivilege cfgIpmiSolAccumulateInterval AccumulateInterval cfgIpmiSolSendThreshold SendThreshold cfgIpmiLan iDRAC.IPMILan cfgIpmiLanEnable Enable cfgIpmiLanPrivilegeLimit PrivLimit cfgIpmiLanAlertEnable AlertEnable cfgIpmiEncryptionKey EncryptionKey cfgIpmiPetCommunityName CommunityName cfgUserDomain iDRAC.
Legacy Groups and Objects New Groups and Objects cfgVFlashPartitionEmulationType EmulationType cfgVFlashPartitionFlashOSVolLabel VolumeLabel cfgVFlashPartitionFormatType FormatType cfgVFlashPartitionAccessType AccessType cfgVFlashPartitionAttachState AttachState cfgServerInfo iDRAC.ServerBoot cfgServerBootOnce BootOnce cfgServerFirstBootDevice FirstBootDevice cfgLogging iDRAC.Logging cfgLoggingSELOEMEventFilterEnable SELOEMEventFilterEnable iDRAC.SNMP.
Execute Server Control Commands 0x00000010 Access Virtual Console 0x00000020 Access Virtual Media 0x00000040 Test Alerts 0x00000080 Execute Debug Commands 0x00000100 484 Legacy and New Groups and Objects