Reference Guide

setled
Description Sets the state (blinking or not blinking) of the LED on the specified module.
To run this subcommand, you must have the Configure iDRAC permission.
Synopsis
racadm setled -l <ledState>
Input
-l <ledState> — Specifies the LED state. The values are:
0 — No Blinking
1 — Blinking
Example
From iDRAC stop LED from blinking.
racadm setled -l 0
RAC0908: System ID LED blink off.
From iDRAC start LED to blink.
racadm setled -l 1
RAC0907: System ID LED blink on.
setniccfg
Description
Sets the iDRAC IP address for static and DHCP modes.
To run this subcommand, you must have the Configure iDRAC privilege.
NOTE: The terms NIC and Ethernet management port may be used interchangeably.
Synopsis
racadm setniccfg -d
racadm setniccfg -d6
racadm setniccfg -s <IPv4Address> <netmask> <IPv4 gateway>
racadm setniccfg -s6 <IPv6 Address> <IPv6 Prefix Length> <IPv6 Gateway>
racadm setniccfg -o
Input
-d — Enables DHCP for the NIC. It is enabled by default.
-d6 — Enables AutoConfig for the NIC (default is disabled).
-s — Enables static IP settings. The IPv4 address, netmask, and gateway must be specified. Otherwise, the
existing static settings are used.
<ipaddress>, <netmask>, and <gateway> must be typed as dot-
separated strings.
racadm setniccfg -s 192.168.0 255.255.255.0 192.168.0
-s6 — Enables static IPv6 settings. The IPv6 address, Prefix Length, and the IPv6 Gateway can be specified.
-o — Enable or disable NIC.
RACADM Subcommand Details 107